Skip to main content
Top

2024 | OriginalPaper | Chapter

Design of Photoplethysmography (PPG)-Based Respiratory Rate Measuring Device Through Peak Calculations

Authors : Ummul Muthmainnah, Willy Anugrah Cahyadi, Husneni Mukhtar, Muhammad Abdul Hakiim Al Fatih, Denny Tri Sukmono

Published in: Proceedings of the 4th International Conference on Electronics, Biomedical Engineering, and Health Informatics

Publisher: Springer Nature Singapore

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

Respiratory rate is one of the essential components in measuring vital signs that convey information about health conditions and diagnoses to patients measured in breaths per minute (BrPM). Breaths per minute refer to the number of breaths taken by a person in one minute. The current clinical respiratory rate calculation method, i.e., a standard calculation by counting the number of chest movements, can cause patient discomfort, bias in counting, and waste the nurse’s time. This study aims to develop a tool for measuring respiratory rate by recording a one-minute photoplethysmography (PPG) signal non-invasively that is more comfortable and easier to use. The PPG signal obtained is first processed to remove unnecessary signal frequencies. The developed algorithm counts the number of peaks in the PPG signal to calculate the respiratory rate. It employs Zero-Phase Filtering to remove noise and motion artifacts (MA) on the signal to calculate the number of peaks in one minute. The device is designed using the MAX30102 sensor, XIAO ESP32-C3 controller, and TFT OLED display to show the measurement value. This tool uses a 3D case and Velcro tape on the sensor to reduce the possibility of a Motion Artifact appearing in the signal. The respiratory rate prediction test results obtained more than 94% accuracy with a maximum error of 3 BrPM in five subjects aged 15–48 years who were in good health. Based on the results, measuring respiratory rate from the PPG signal with a wearable device design can be a quite effective non-invasive solution and contribute to the medical world for measuring vital signs.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Loughlin PC, Sebat F, Kellett JG (2018) Respiratory rate: the forgotten vital sign—make it count! Joint Comm J Qual Patient Safety Loughlin PC, Sebat F, Kellett JG (2018) Respiratory rate: the forgotten vital sign—make it count! Joint Comm J Qual Patient Safety
2.
go back to reference Guruh IB, Maghfiroh AM, Solichin AA, Bintoro FY (2022) Vital sign monitor based on telemedicine using android application on mobile phone. In: Triwiyanto T, Rizal A, CW (ed) Proceedings of the 2nd international conference on electronics, biomedical engineering, and health informatics. Springer Nature Singapore, Singapore, pp 73–83 Guruh IB, Maghfiroh AM, Solichin AA, Bintoro FY (2022) Vital sign monitor based on telemedicine using android application on mobile phone. In: Triwiyanto T, Rizal A, CW (ed) Proceedings of the 2nd international conference on electronics, biomedical engineering, and health informatics. Springer Nature Singapore, Singapore, pp 73–83
3.
go back to reference Nicolò A, Massaroni C, Schena E, Sacchetti M (2020) The importance of respiratory rate monitoring: from healthcare to sport and exercise. Sensors (Switzerland) 20:1–45CrossRef Nicolò A, Massaroni C, Schena E, Sacchetti M (2020) The importance of respiratory rate monitoring: from healthcare to sport and exercise. Sensors (Switzerland) 20:1–45CrossRef
4.
go back to reference Institute of Electrical and Electronics Engineers Malaysia Section, Annual IEEE computer conference, IEEE symposium on computer applications and industrial electronics 2015.04.12–14 Langakwi, ISCAIE 2015.04.12–14 Langakwi Respiratory Rate of Photoplethysmogram Signal from Anaesthetic Patients Institute of Electrical and Electronics Engineers Malaysia Section, Annual IEEE computer conference, IEEE symposium on computer applications and industrial electronics 2015.04.12–14 Langakwi, ISCAIE 2015.04.12–14 Langakwi Respiratory Rate of Photoplethysmogram Signal from Anaesthetic Patients
5.
go back to reference Ren L, Wang H, Naishadham K, Liu Q, Fathy AE (2015) Non-invasive detection of cardiac and respiratory rates from stepped frequency continuous wave radar measurements using the state space method. In: 2015 IEEE MTT-S international microwave symposium, pp 1–4 Ren L, Wang H, Naishadham K, Liu Q, Fathy AE (2015) Non-invasive detection of cardiac and respiratory rates from stepped frequency continuous wave radar measurements using the state space method. In: 2015 IEEE MTT-S international microwave symposium, pp 1–4
6.
go back to reference Reuter S, Moser C, Baack M, Falls S (2014) Respiratory distress in the newborn. American Academy of Pediatrics Reuter S, Moser C, Baack M, Falls S (2014) Respiratory distress in the newborn. American Academy of Pediatrics
7.
go back to reference Prinable J, Jones P, Boland D, McEwan A, Thamrin C (2020) Derivation of respiratory metrics in health and asthma. Sensors (Switzerland) 20:1–11CrossRef Prinable J, Jones P, Boland D, McEwan A, Thamrin C (2020) Derivation of respiratory metrics in health and asthma. Sensors (Switzerland) 20:1–11CrossRef
8.
go back to reference Sepriani R (2017) Pengaruh pemberian minuman beroksigen terhadap kemampuan volume Oksigen Maksimal (VO2 Maks). Menssana 2 Sepriani R (2017) Pengaruh pemberian minuman beroksigen terhadap kemampuan volume Oksigen Maksimal (VO2 Maks). Menssana 2
9.
go back to reference Kumar P, Sharma A, Zimik M, Parashar S, Singh R, Bora J, Patra AK, Mishra M (2020) Measurement of heartbeats for well-being assessment using photoplethysmographic signals. In: Mallick PK, Meher P, Majumder A, Das SK (ed) Electronic systems and intelligent computing. Springer Singapore, Singapore, pp 485–494 Kumar P, Sharma A, Zimik M, Parashar S, Singh R, Bora J, Patra AK, Mishra M (2020) Measurement of heartbeats for well-being assessment using photoplethysmographic signals. In: Mallick PK, Meher P, Majumder A, Das SK (ed) Electronic systems and intelligent computing. Springer Singapore, Singapore, pp 485–494
10.
go back to reference Bavkar Vandana C, Shinde A (2023) The use of photoplethysmography for blood glucose estimation by noninvasive method. In: Shreesha C, Bandyopadhyay R (ed) Smart sensors measurement and instrumentation. Springer Nature Singapore, Singapore, pp 323–335 Bavkar Vandana C, Shinde A (2023) The use of photoplethysmography for blood glucose estimation by noninvasive method. In: Shreesha C, Bandyopadhyay R (ed) Smart sensors measurement and instrumentation. Springer Nature Singapore, Singapore, pp 323–335
11.
go back to reference Ungureanu G-M, Aarts RM, Arends J (2014) Real-time extraction of the respiratory rate from photoplethysmographic signal using wearable devices Ungureanu G-M, Aarts RM, Arends J (2014) Real-time extraction of the respiratory rate from photoplethysmographic signal using wearable devices
12.
go back to reference Hoilett O, Twibell A, Srivastav R, Callihan Linnes J (2018) Kick LL: a smartwatch for monitoring respiration and heart rate using photoplethysmography Hoilett O, Twibell A, Srivastav R, Callihan Linnes J (2018) Kick LL: a smartwatch for monitoring respiration and heart rate using photoplethysmography
17.
go back to reference Goecks J, Jalili V, Heiser LM, Gray JW (2020) How machine learning will transform biomedicine. Cell 181:92–101CrossRef Goecks J, Jalili V, Heiser LM, Gray JW (2020) How machine learning will transform biomedicine. Cell 181:92–101CrossRef
18.
go back to reference Weissler EH, Naumann T, Andersson T, Ranganath R, Elemento O, Luo Y, Freitag DF, Benoit J, Hughes MC, Khan F, Slater P, Shameer K, Roe M, Hutchison E, Kollins SH, Broedl U, Meng Z, Wong JL, Curtis L, Huang E, Ghassemi M (2021) The role of machine learning in clinical research: transforming the future of evidence generation. Trials 22 Weissler EH, Naumann T, Andersson T, Ranganath R, Elemento O, Luo Y, Freitag DF, Benoit J, Hughes MC, Khan F, Slater P, Shameer K, Roe M, Hutchison E, Kollins SH, Broedl U, Meng Z, Wong JL, Curtis L, Huang E, Ghassemi M (2021) The role of machine learning in clinical research: transforming the future of evidence generation. Trials 22
19.
go back to reference Přibil J, Přibilová A, Frollo I (2020) Comparative measurement of the PPG signal on different human body positions by sensors working in reflection and transmission modes Přibil J, Přibilová A, Frollo I (2020) Comparative measurement of the PPG signal on different human body positions by sensors working in reflection and transmission modes
20.
go back to reference Sulistyowati A (2018) Pemeriksaan Tanda Tanda Vital. Akademi Keperawatan Kerta Cendekia Sidoarjo Sulistyowati A (2018) Pemeriksaan Tanda Tanda Vital. Akademi Keperawatan Kerta Cendekia Sidoarjo
21.
go back to reference Kang M, Shin S, Kang KH, Kim YT (2020) Multi bio-signal based algorithm using EMD and FFT for stress analysis. In: 2020 IEEE international conference on consumer electronics (ICCE), pp 1–4 Kang M, Shin S, Kang KH, Kim YT (2020) Multi bio-signal based algorithm using EMD and FFT for stress analysis. In: 2020 IEEE international conference on consumer electronics (ICCE), pp 1–4
23.
go back to reference Mohd Sani NH, Mansor W, Lee KY, Ahmad Zainudin N, Mahrim SA (2015) Determination of heart rate from photoplethysmogram using Fast Fourier transform. In: 2015 international conference on BioSignal analysis, processing and systems (ICBAPS), pp 168–170 Mohd Sani NH, Mansor W, Lee KY, Ahmad Zainudin N, Mahrim SA (2015) Determination of heart rate from photoplethysmogram using Fast Fourier transform. In: 2015 international conference on BioSignal analysis, processing and systems (ICBAPS), pp 168–170
24.
go back to reference Park J, Seok HS, Kim SS, Shin H (2022) Photoplethysmogram analysis and applications: an integrative review. Front Physiol 12 Park J, Seok HS, Kim SS, Shin H (2022) Photoplethysmogram analysis and applications: an integrative review. Front Physiol 12
25.
go back to reference An X, Stylios GK (2020) Comparison of motion artefact reduction methods and the implementation of adaptive motion artefact reduction in wearable electrocardiogram monitoring An X, Stylios GK (2020) Comparison of motion artefact reduction methods and the implementation of adaptive motion artefact reduction in wearable electrocardiogram monitoring
29.
go back to reference Moraes Filho AA, Schreiber G, Sieg JA, Much MD, Moura Bartoski V, Marcon C (2023) Methods to estimate respiratory rate using the photoplethysmography signal. In: 16th international joint conference on biomedical engineering systems and technologies (BIOSTEC 2023) - Volume 5: Healthinf, pp 445–452 Moraes Filho AA, Schreiber G, Sieg JA, Much MD, Moura Bartoski V, Marcon C (2023) Methods to estimate respiratory rate using the photoplethysmography signal. In: 16th international joint conference on biomedical engineering systems and technologies (BIOSTEC 2023) - Volume 5: Healthinf, pp 445–452
30.
go back to reference Mohd Sani NH, Mansor W, Lee KY, Ahmad Zainudin N, Mahrim SA (2015) Determination of heart rate from photoplethysmogram using Fast Fourier transform. In: 2015 international conference on BioSignal analysis, processing and systems, ICBAPS 2015. Institute of Electrical and Electronics Engineers Inc., pp 168–170 Mohd Sani NH, Mansor W, Lee KY, Ahmad Zainudin N, Mahrim SA (2015) Determination of heart rate from photoplethysmogram using Fast Fourier transform. In: 2015 international conference on BioSignal analysis, processing and systems, ICBAPS 2015. Institute of Electrical and Electronics Engineers Inc., pp 168–170
32.
go back to reference Yulian R, Suprianto B (2017) Rancang Bangun Photoplethysmography (PPG) Tipe Gelang Tangan untuk Menghitung Detak Jantung Berbasis Arduino Yulian R, Suprianto B (2017) Rancang Bangun Photoplethysmography (PPG) Tipe Gelang Tangan untuk Menghitung Detak Jantung Berbasis Arduino
33.
go back to reference Ishikawa T, Hyodo Y, Miyashita K, Yoshifuji K, Komoriya Y, Imai Y (2017) Wearable motion tolerant PPG sensor for instant heart rate in daily activity. In: BIOSIGNALS 2017 - 10th international conference on bio-inspired systems and signal processing, proceedings; Part of 10th international joint conference on biomedical engineering systems and technologies, BIOSTEC 2017. SciTePress, pp 126–133 Ishikawa T, Hyodo Y, Miyashita K, Yoshifuji K, Komoriya Y, Imai Y (2017) Wearable motion tolerant PPG sensor for instant heart rate in daily activity. In: BIOSIGNALS 2017 - 10th international conference on bio-inspired systems and signal processing, proceedings; Part of 10th international joint conference on biomedical engineering systems and technologies, BIOSTEC 2017. SciTePress, pp 126–133
35.
go back to reference Almarshad MA, Islam MS, Al-Ahmadi S, Bahammam AS (2022) Diagnostic features and potential applications of PPG signal in healthcare: a systematic review. Healthcare (Switzerland) 10 Almarshad MA, Islam MS, Al-Ahmadi S, Bahammam AS (2022) Diagnostic features and potential applications of PPG signal in healthcare: a systematic review. Healthcare (Switzerland) 10
Metadata
Title
Design of Photoplethysmography (PPG)-Based Respiratory Rate Measuring Device Through Peak Calculations
Authors
Ummul Muthmainnah
Willy Anugrah Cahyadi
Husneni Mukhtar
Muhammad Abdul Hakiim Al Fatih
Denny Tri Sukmono
Copyright Year
2024
Publisher
Springer Nature Singapore
DOI
https://doi.org/10.1007/978-981-97-1463-6_10