Skip to main content
Top

2015 | OriginalPaper | Chapter

The Energy Demand of Data Centers

Authors : Gunnar Schomaker, Stefan Janacek, Daniel Schlitt

Published in: ICT Innovations for Sustainability

Publisher: Springer International Publishing

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

Data centers are the backbone of today’s information technologies. With increasing usage of cloud services and web applications, the need for remote computing and storage will only grow. However, one has to consider that increasing numbers of server and storage systems also mean increases in energy consumption. The power demand is caused not only by the IT hardware, but is also due to the required infrastructure such as power supply and climatization. Therefore, choosing the most appropriate components as well as architectural designs and configurations regarding energy demand, availability, and performance is important. This chapter depicts influencing factors and current trends for these design choices and provides examples.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference APC: Guidelines for specifying data center criticality/tier levels (2007) APC: Guidelines for specifying data center criticality/tier levels (2007)
3.
go back to reference Hintemann, R.: Die Trends in Rechenzentren bis 2015, Ergebnisse einer neuen Studie im Auftrag des Umweltbundesamtes (2010) Hintemann, R.: Die Trends in Rechenzentren bis 2015, Ergebnisse einer neuen Studie im Auftrag des Umweltbundesamtes (2010)
4.
go back to reference Janacek, S., Schroeder, K., Schomaker, G., Nebel, W., Rueuschen, M., Pistoor, G.: Modeling and approaching a cost transparent, specific data center power consumption. In: 2012 International Conference on Energy Aware Computing, pp. 68–73 (2012) Janacek, S., Schroeder, K., Schomaker, G., Nebel, W., Rueuschen, M., Pistoor, G.: Modeling and approaching a cost transparent, specific data center power consumption. In: 2012 International Conference on Energy Aware Computing, pp. 68–73 (2012)
6.
go back to reference Hoyer, M., Schroeder, K., Schlitt, D., Nebel, W.: Proactive dynamic resource management in virtualized data centers. In: Proceedings of the 2nd International Conference on Energy-Efficient Computing and Networking (2011) Hoyer, M., Schroeder, K., Schlitt, D., Nebel, W.: Proactive dynamic resource management in virtualized data centers. In: Proceedings of the 2nd International Conference on Energy-Efficient Computing and Networking (2011)
7.
go back to reference Tantar, A.A., Tantar, E., Bouvry, P.: Load balancing for sustainable ict. In: Proceedings of the 13th Annual Conference Companion on Genetic and Evolutionary Computation, GECCO ‘11, pp. 733–738. ACM, New York (2011) Tantar, A.A., Tantar, E., Bouvry, P.: Load balancing for sustainable ict. In: Proceedings of the 13th Annual Conference Companion on Genetic and Evolutionary Computation, GECCO ‘11, pp. 733–738. ACM, New York (2011)
9.
go back to reference Belady, C., Rawson, A., Pflueger, J., Cader, T.: The Green Grid Data Center Power Efficiency Metrics: PUE and DCiE (2008) Belady, C., Rawson, A., Pflueger, J., Cader, T.: The Green Grid Data Center Power Efficiency Metrics: PUE and DCiE (2008)
10.
go back to reference Avelar, V., Azevedo, D., French, A.: PUE: A Comprehensive Examination of the Metric. White Paper (2012) Avelar, V., Azevedo, D., French, A.: PUE: A Comprehensive Examination of the Metric. White Paper (2012)
11.
go back to reference Schlitt, D., Schomaker, G., Nebel, W.: Gain more from PUE: assessing data center infrastructure power adaptability. In: 3rd International Workshop on Energy-Efficient Data Centres (2014) Schlitt, D., Schomaker, G., Nebel, W.: Gain more from PUE: assessing data center infrastructure power adaptability. In: 3rd International Workshop on Energy-Efficient Data Centres (2014)
12.
go back to reference Pflueger, J.: Re-defining the ‘green’ data center (2008) Pflueger, J.: Re-defining the ‘green’ data center (2008)
13.
go back to reference Haas, J., Monroe, M., Pflueger, J., Pouchet, J., Snelling, P., Rawson, A., Rawson, F.: Proxy proposals for measuring data center productivity. Consortium Green Grid (2009) Haas, J., Monroe, M., Pflueger, J., Pouchet, J., Snelling, P., Rawson, A., Rawson, F.: Proxy proposals for measuring data center productivity. Consortium Green Grid (2009)
14.
go back to reference Lange, K.: Identifying shades of green: The SPECpower benchmarks. Computer 42(3), 95–97 (2009)CrossRef Lange, K.: Identifying shades of green: The SPECpower benchmarks. Computer 42(3), 95–97 (2009)CrossRef
15.
go back to reference Poess, M., Nambiar, R., Vaid, K., Stephens Jr, J., Huppler, K., Haines, E.: Energy benchmarks: a detailed analysis. In: Proceedings of the 1st International Conference on Energy-Efficient Computing and Networking, pp. 131–140. ACM (2010) Poess, M., Nambiar, R., Vaid, K., Stephens Jr, J., Huppler, K., Haines, E.: Energy benchmarks: a detailed analysis. In: Proceedings of the 1st International Conference on Energy-Efficient Computing and Networking, pp. 131–140. ACM (2010)
16.
go back to reference Schlitt, D., Nebel, W.: Load dependent data center energy efficiency metric based on component models. In: Proceedings of 2012 International Conference on Energy Aware Computing (ICEAC 2012), pp. 20–25. IEEE (2012) Schlitt, D., Nebel, W.: Load dependent data center energy efficiency metric based on component models. In: Proceedings of 2012 International Conference on Energy Aware Computing (ICEAC 2012), pp. 20–25. IEEE (2012)
17.
go back to reference Patterson, M., Tschudi, B., Vangeet, O., Cooley, J., Azevedo, D.: ERE: A metric for measuring the benefit of reuse energy from a data center. The Green Grid: Metrics and Measurements. White Paper (2010) Patterson, M., Tschudi, B., Vangeet, O., Cooley, J., Azevedo, D.: ERE: A metric for measuring the benefit of reuse energy from a data center. The Green Grid: Metrics and Measurements. White Paper (2010)
18.
go back to reference Belady, C., Azevedo, D., Patterson, M., Pouchet, J., Tipley, R.: Carbon Usage Effectiveness (CUE): A Green Grid Data Center Sustainability Metric. White Paper, vol. 32 (2010) Belady, C., Azevedo, D., Patterson, M., Pouchet, J., Tipley, R.: Carbon Usage Effectiveness (CUE): A Green Grid Data Center Sustainability Metric. White Paper, vol. 32 (2010)
19.
go back to reference Patterson, M., Azevedo, D., Belady, C., Pouchet, J.: Water Usage Effectiveness (WUE): A Green Grid Data Center Sustainability Metric. White Paper, vol. 35 (2011) Patterson, M., Azevedo, D., Belady, C., Pouchet, J.: Water Usage Effectiveness (WUE): A Green Grid Data Center Sustainability Metric. White Paper, vol. 35 (2011)
20.
go back to reference Ren, C., Wang, D., Urgaonkar, B., Sivasubramaniam, A.: Carbon-aware energy capacity planning for datacenters. In: Proceedings of 2012 IEEE 20th International Symposium on Modeling, Analysis Simulation of Computer and Telecommunication Systems (MASCOTS), pp. 391–400 (2012) Ren, C., Wang, D., Urgaonkar, B., Sivasubramaniam, A.: Carbon-aware energy capacity planning for datacenters. In: Proceedings of 2012 IEEE 20th International Symposium on Modeling, Analysis Simulation of Computer and Telecommunication Systems (MASCOTS), pp. 391–400 (2012)
21.
go back to reference Ghamkhari, M., Mohsenian-Rad, H.: Optimal integration of renewable energy resources in data centers with behind-the-meter renewable generator. In: IEEE International Conference on Communications (ICC) (2012) Ghamkhari, M., Mohsenian-Rad, H.: Optimal integration of renewable energy resources in data centers with behind-the-meter renewable generator. In: IEEE International Conference on Communications (ICC) (2012)
22.
go back to reference Zhang, Y., Wang, Y., Wang, X.: Greenware: greening cloud-scale data centers to maximize the use of renewable energy. In: Kon, F., Kermarrec, A.M. (eds.) Middleware 2011, Lecture Notes in Computer Science, vol. 7049, pp. 143–164. Springer, Berlin (2011) Zhang, Y., Wang, Y., Wang, X.: Greenware: greening cloud-scale data centers to maximize the use of renewable energy. In: Kon, F., Kermarrec, A.M. (eds.) Middleware 2011, Lecture Notes in Computer Science, vol. 7049, pp. 143–164. Springer, Berlin (2011)
23.
go back to reference Mohsenian-Rad, H., Leon-Garcia, A.: Coordination of cloud computing and smart power grids. In: Proceedings of IEEE Smart Grid Communications Conference, Gaithersburg, Maryland (2010) Mohsenian-Rad, H., Leon-Garcia, A.: Coordination of cloud computing and smart power grids. In: Proceedings of IEEE Smart Grid Communications Conference, Gaithersburg, Maryland (2010)
25.
go back to reference Brunschwiler, T., Smith, B., Ruetsche, E., Michel, B.: Toward zero-emission data centers through direct reuse of thermal energy. IBM J. Res. Dev. 53(3), 11:1–11:13 (2009) Brunschwiler, T., Smith, B., Ruetsche, E., Michel, B.: Toward zero-emission data centers through direct reuse of thermal energy. IBM J. Res. Dev. 53(3), 11:1–11:13 (2009)
26.
go back to reference Brodkin, J.: Swimming pool heated by data center’s excess heat (Computerworld) (2008) Brodkin, J.: Swimming pool heated by data center’s excess heat (Computerworld) (2008)
Metadata
Title
The Energy Demand of Data Centers
Authors
Gunnar Schomaker
Stefan Janacek
Daniel Schlitt
Copyright Year
2015
DOI
https://doi.org/10.1007/978-3-319-09228-7_6

Premium Partner