Skip to main content
Erschienen in: Measurement Techniques 3/2015

01.06.2015 | MECHANICAL MEASUREMENTS

A Compact Marked Nuclear-Magnetic Flowmeter for Measurement of Rapidly Varying Flow Rates of Liquid

verfasst von: V. V. Davydov, V. I. Dudkin, A. Yu. Karseev

Erschienen in: Measurement Techniques | Ausgabe 3/2015

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

A compact marked nuclear-magnetic flowmeter is described. The principal elements of the construction of the flowmeter and a circuit for detection of the nuclear-magnetic resonance signal are modernized. A high degree of precision of measurements of the fl ow rate of a liquid with the use of the effect of paramagnetic resonance and a new construction of the analyzer vessel are achieved. A compact circuit for processing the obtained information based on a microcontroller is developed.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat P. P. Kremlevskii, Flowmeters and Quantity Counters, Politekhnika, Mashinostroenie, St. Petersburg (2004), Book 2. P. P. Kremlevskii, Flowmeters and Quantity Counters, Politekhnika, Mashinostroenie, St. Petersburg (2004), Book 2.
2.
Zurück zum Zitat A. V. Pushnov, “Measurement of the fl ow rate of a two-phase fl ow by a Coriolis flowmeter,” Izmer. Tekhn., No. 4, 45–48 (2 013); Measur. Techn., 56, No. 4, 421–425 (2013). A. V. Pushnov, “Measurement of the fl ow rate of a two-phase fl ow by a Coriolis flowmeter,” Izmer. Tekhn., No. 4, 45–48 (2 013); Measur. Techn., 56, No. 4, 421–425 (2013).
3.
Zurück zum Zitat I. D. Velt and Yu. V. Mikhailova, “Magnetic flowmeter of molten metals,” Izmer. Tekhn., No. 3, 24–28 (2013); Measur. Techn., 56, No. 3, 283–288 (2013). I. D. Velt and Yu. V. Mikhailova, “Magnetic flowmeter of molten metals,” Izmer. Tekhn., No. 3, 24–28 (2013); Measur. Techn., 56, No. 3, 283–288 (2013).
4.
Zurück zum Zitat I. D. Velt and Yu. V. Mikhailova, “An electromagnetic method of measurement of the fl ow rate and level of a liquid in free-flow pipelines,” Izmer. Tekhn., No. 7, 45–50 (2013); Measur. Techn., 56, No. 7, 797–804 (2013). I. D. Velt and Yu. V. Mikhailova, “An electromagnetic method of measurement of the fl ow rate and level of a liquid in free-flow pipelines,” Izmer. Tekhn., No. 7, 45–50 (2013); Measur. Techn., 56, No. 7, 797–804 (2013).
5.
Zurück zum Zitat V. V. Davydov and V. V. Semenov, “Unsteady operating conditions of nutation nuclear-magnetic resonance flowmeters and magnetometers,” Prib. Tekhn. Eksperim., No. 3, 151–153 (1999). V. V. Davydov and V. V. Semenov, “Unsteady operating conditions of nutation nuclear-magnetic resonance flowmeters and magnetometers,” Prib. Tekhn. Eksperim., No. 3, 151–153 (1999).
6.
Zurück zum Zitat A. E. Pryakhin, S. S. Shushkevich, I. O. Orobei, et al., “A nuclear-magnetic flowmeter of liquids,” Prib. Tekhn. Eksperim., No. 6, 216 (1986). A. E. Pryakhin, S. S. Shushkevich, I. O. Orobei, et al., “A nuclear-magnetic flowmeter of liquids,” Prib. Tekhn. Eksperim., No. 6, 216 (1986).
7.
Zurück zum Zitat A. E. Pryakhin, S. S. Shushkevich, I. O. Orobei, et al., “A technique of calculating the relaxation errors of marked nutation-phase–type nuclear-magnetic flowmeters in laminar flow,” Inzh.-Fiz. Zh., 51, No. 6, 1011–1015 (1986). A. E. Pryakhin, S. S. Shushkevich, I. O. Orobei, et al., “A technique of calculating the relaxation errors of marked nutation-phase–type nuclear-magnetic flowmeters in laminar flow,” Inzh.-Fiz. Zh., 51, No. 6, 1011–1015 (1986).
8.
Zurück zum Zitat V. V. Davydov, “Compact polarizer for nuclear-magnetic flowmeters and magnetometers,” Izv. Vyzov. Priborostr., 44, No. 8, 49–52 (2001). V. V. Davydov, “Compact polarizer for nuclear-magnetic flowmeters and magnetometers,” Izv. Vyzov. Priborostr., 44, No. 8, 49–52 (2001).
9.
Zurück zum Zitat V. V. Davydov and V. I. Dudkin, “Operating regime of a marked nuclear-magnetic resonance flowmeter based on the effect of parametric resonance,” Izv. Vyzov. Priborostr., 45, No. 5, 49–51(2002). V. V. Davydov and V. I. Dudkin, “Operating regime of a marked nuclear-magnetic resonance flowmeter based on the effect of parametric resonance,” Izv. Vyzov. Priborostr., 45, No. 5, 49–51(2002).
10.
Zurück zum Zitat A. E. Pryakhin and A. E. Faybyshev, “Converter of the signal of a nuclear-magnetic resonance flowmeter,” Prib. Tekhn. Eksperim., No. 3, 200–201 (1985). A. E. Pryakhin and A. E. Faybyshev, “Converter of the signal of a nuclear-magnetic resonance flowmeter,” Prib. Tekhn. Eksperim., No. 3, 200–201 (1985).
11.
Zurück zum Zitat V. V. Davydov and V. V. Semenov, “Nutation lines of nuclear-magnetic spectrometer with fl owing sample,” adiotekhn. Elektron., 44, No. 12, 1528–1531 (1999). V. V. Davydov and V. V. Semenov, “Nutation lines of nuclear-magnetic spectrometer with fl owing sample,” adiotekhn. Elektron., 44, No. 12, 1528–1531 (1999).
12.
Zurück zum Zitat A. Leshe, Nuclear Induction [Russian translation], IIL, Moscow (1963). A. Leshe, Nuclear Induction [Russian translation], IIL, Moscow (1963).
13.
Zurück zum Zitat V. V. Davydov, V. I. Dudkin, and A. U. Karseev, “Nuclear-magnetic flowmeter-spectrometer with fi ber-optical communication line in cooling sysetms of atomic energy plants,” Opt. Mem. & Neur. Netw. (Inform. Optics), 22, No. 2, 112–117 (2013).CrossRef V. V. Davydov, V. I. Dudkin, and A. U. Karseev, “Nuclear-magnetic flowmeter-spectrometer with fi ber-optical communication line in cooling sysetms of atomic energy plants,” Opt. Mem. & Neur. Netw. (Inform. Optics), 22, No. 2, 112–117 (2013).CrossRef
14.
Zurück zum Zitat M. Ramsei, Molecular Beams [Russian translation], IIL, Moscow (1960). M. Ramsei, Molecular Beams [Russian translation], IIL, Moscow (1960).
15.
Zurück zum Zitat V. V. Davydov, V. I. Dudkin, and A. U. Karseev, “Increasing the precision of measurements of the relaxation constants of a flowing liquid in a nuclear-magnetic spectrometer,” Izv. Vyzov. Priborostr., 56, No. 10, 64–68 (2013). V. V. Davydov, V. I. Dudkin, and A. U. Karseev, “Increasing the precision of measurements of the relaxation constants of a flowing liquid in a nuclear-magnetic spectrometer,” Izv. Vyzov. Priborostr., 56, No. 10, 64–68 (2013).
Metadaten
Titel
A Compact Marked Nuclear-Magnetic Flowmeter for Measurement of Rapidly Varying Flow Rates of Liquid
verfasst von
V. V. Davydov
V. I. Dudkin
A. Yu. Karseev
Publikationsdatum
01.06.2015
Verlag
Springer US
Erschienen in
Measurement Techniques / Ausgabe 3/2015
Print ISSN: 0543-1972
Elektronische ISSN: 1573-8906
DOI
https://doi.org/10.1007/s11018-015-0707-1

Weitere Artikel der Ausgabe 3/2015

Measurement Techniques 3/2015 Zur Ausgabe