Skip to main content
Erschienen in: Medical & Biological Engineering & Computing 1/2015

01.01.2015 | Original Article

A new layered sensor for simultaneous measurement of EMG, MMG and oxygen consumption at the same position

verfasst von: Akira Kimoto, Yuji Yamada

Erschienen in: Medical & Biological Engineering & Computing | Ausgabe 1/2015

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

A new layered sensor for simultaneous measurement of electromyography (EMG), mechanomyography (MMG) and oxygen consumption based on near-infrared spectroscopy (NIRS) at the same position of the muscle is presented. The proposed sensor is a layered structure of a thin stainless-steel electrode, a PVDF film with transparent electrodes and optical sensors. EMG, MMG and oxygen consumption based on NIRS are measured by the stainless-steel electrodes, PVDF film and optical sensors, respectively. Using the three types of data, muscular activity can be analyzed in more detail. Additionally, the proposed sensor system reduces the constraint of the sensors arranged on the skin in measurements at multiple points because three types of information, previously obtained with three types of general sensors, are detected by a pair of proposed sensors. In an experiment, simultaneous measurement of EMG, MMG and oxygen consumption via NIRS at the forearm was demonstrated using the proposed sensor under fluorescent light. The performance of the layered sensor was evaluated.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Akataki K, Mita K, Watakabe M (2004) Electromyographic and mechanomyographic estimation of motor unit activation strategy in voluntary force production. Electromyogr Clin Neurophysiol 44:489–496PubMed Akataki K, Mita K, Watakabe M (2004) Electromyographic and mechanomyographic estimation of motor unit activation strategy in voluntary force production. Electromyogr Clin Neurophysiol 44:489–496PubMed
2.
Zurück zum Zitat Barry DT (1987) Acoustic signals from frog skeletal muscle. Biophys J 51:5769–5773CrossRef Barry DT (1987) Acoustic signals from frog skeletal muscle. Biophys J 51:5769–5773CrossRef
3.
Zurück zum Zitat Binzoni T, Cooper CE, Wittekind AL, Beneke R, Elwell CE, Van De Ville D, Leung TS (2010) A new method to measure local oxygen consumption in human skeletal muscle during dynamic exercise using near-infrared spectroscopy. Physiol Meas 31:1257–1269PubMedCrossRef Binzoni T, Cooper CE, Wittekind AL, Beneke R, Elwell CE, Van De Ville D, Leung TS (2010) A new method to measure local oxygen consumption in human skeletal muscle during dynamic exercise using near-infrared spectroscopy. Physiol Meas 31:1257–1269PubMedCrossRef
4.
Zurück zum Zitat Cescon C, Farina D, Gobbo M, Merletti R, Orizio R (2004) Effect of accelerometer location on mechanomyogram variables during voluntary, constant-force contractions in three human muscles. Med Biol Eng Comput 42:121–128PubMedCrossRef Cescon C, Farina D, Gobbo M, Merletti R, Orizio R (2004) Effect of accelerometer location on mechanomyogram variables during voluntary, constant-force contractions in three human muscles. Med Biol Eng Comput 42:121–128PubMedCrossRef
5.
Zurück zum Zitat De Blasi RA, Cope M, Elwell C, Safoue F, Ferrari M (1993) Noninvasive measurement of human forearm oxygen consumption by near infrared spectroscopy. Eur J Appl Physiol 67:20–25CrossRef De Blasi RA, Cope M, Elwell C, Safoue F, Ferrari M (1993) Noninvasive measurement of human forearm oxygen consumption by near infrared spectroscopy. Eur J Appl Physiol 67:20–25CrossRef
6.
Zurück zum Zitat Feipel V, Aubin CE, Ciolofan OC, Beauséjour M, Labelle H, Mathieu PA (2002) Electromyogram and kinematic analysis of lateral bending in idiopathic scoliosis patients. Med Biol Eng Comput 40:497–505PubMedCrossRef Feipel V, Aubin CE, Ciolofan OC, Beauséjour M, Labelle H, Mathieu PA (2002) Electromyogram and kinematic analysis of lateral bending in idiopathic scoliosis patients. Med Biol Eng Comput 40:497–505PubMedCrossRef
7.
Zurück zum Zitat Geršak V, Geršak G (2009) NIRS: Measuring changes in muscle oxygenation and the detection of muscle activity. In: Proceedings of XIX IMEKO World Congress, pp 1634–1639 Geršak V, Geršak G (2009) NIRS: Measuring changes in muscle oxygenation and the detection of muscle activity. In: Proceedings of XIX IMEKO World Congress, pp 1634–1639
8.
Zurück zum Zitat Gordon G, Holbourn AHS (1948) The sound from single motor units in as contracting muscle. J Physiol I07:456–464CrossRef Gordon G, Holbourn AHS (1948) The sound from single motor units in as contracting muscle. J Physiol I07:456–464CrossRef
9.
Zurück zum Zitat Gregori B, Galié E, Accornero N (2003) Surface electromyography and mechanomyography recording: a new differential composite probe. Med Biol Eng Comput 41:665–669PubMedCrossRef Gregori B, Galié E, Accornero N (2003) Surface electromyography and mechanomyography recording: a new differential composite probe. Med Biol Eng Comput 41:665–669PubMedCrossRef
10.
Zurück zum Zitat Hendrix CR, Hooush TJ, Camic CL, Zuniga JM, Johnson GO, Schmidt RJ (2010) Comparing electromyographic and mechanomyographic frequency-based fatigue thresholds to critical torque during isometric forearm flexion. J Neurosci Methods 194:64–72PubMedCrossRef Hendrix CR, Hooush TJ, Camic CL, Zuniga JM, Johnson GO, Schmidt RJ (2010) Comparing electromyographic and mechanomyographic frequency-based fatigue thresholds to critical torque during isometric forearm flexion. J Neurosci Methods 194:64–72PubMedCrossRef
11.
Zurück zum Zitat Ioi H, Kawakatsu M, Nakata S, Nakasima A, Counts AL (2006) Mechanomyogram and electromyogram analyses for investigating human masseter muscle fatigue. Orthod Waves 65:15–20CrossRef Ioi H, Kawakatsu M, Nakata S, Nakasima A, Counts AL (2006) Mechanomyogram and electromyogram analyses for investigating human masseter muscle fatigue. Orthod Waves 65:15–20CrossRef
12.
Zurück zum Zitat Kimoto A, Yamada Y (2012) A proposal of layered sensor for analysis of muscular activity. In: Proceedings of MEMEA2012 Kimoto A, Yamada Y (2012) A proposal of layered sensor for analysis of muscular activity. In: Proceedings of MEMEA2012
13.
Zurück zum Zitat Madeleine P, Ge H, Jaskólska A, Farina D, Jaskólski A, Nielsen LA (2006) Spectral moments of mechanomyographic signals recorded with accelerometer and microphone during sustained fatiguing contractions. Med Biol Eng Comput 44:290–297PubMedCrossRef Madeleine P, Ge H, Jaskólska A, Farina D, Jaskólski A, Nielsen LA (2006) Spectral moments of mechanomyographic signals recorded with accelerometer and microphone during sustained fatiguing contractions. Med Biol Eng Comput 44:290–297PubMedCrossRef
14.
Zurück zum Zitat Madeleine P, Cescon C, Farina D (2006) Spatial and force dependency of mechanomyographic signal features. J Neurosci Methods 158:89–99PubMedCrossRef Madeleine P, Cescon C, Farina D (2006) Spatial and force dependency of mechanomyographic signal features. J Neurosci Methods 158:89–99PubMedCrossRef
15.
Zurück zum Zitat Matcher SJ, Elwell CE, Cooper CE, Cope M, Delpy DT (1995) Performance comparison of several published tissue near-infrared spectroscopy algorithms. Anal Biochem 227:54–68PubMedCrossRef Matcher SJ, Elwell CE, Cooper CE, Cope M, Delpy DT (1995) Performance comparison of several published tissue near-infrared spectroscopy algorithms. Anal Biochem 227:54–68PubMedCrossRef
16.
Zurück zum Zitat Orizio C, Perini R, Veicsteinas A (1989) Changes of muscular sound during sustained isometric contraction up to exhaustion. J Appl Physiol 66(4):1593–1598PubMed Orizio C, Perini R, Veicsteinas A (1989) Changes of muscular sound during sustained isometric contraction up to exhaustion. J Appl Physiol 66(4):1593–1598PubMed
17.
Zurück zum Zitat Orizio C, Perini R, Veicsteinas A (1989) Muscular sound and force relationship during isometric contraction in man. Eur J Appl Physiol 58:528–533CrossRef Orizio C, Perini R, Veicsteinas A (1989) Muscular sound and force relationship during isometric contraction in man. Eur J Appl Physiol 58:528–533CrossRef
18.
Zurück zum Zitat Östlund N, Yu J, Roeleveld K, Karlsson JS (2004) Adaptive spatial filtering of multichannel surface electromyogram signals. Med Biol Eng Comput 42:825–831PubMedCrossRef Östlund N, Yu J, Roeleveld K, Karlsson JS (2004) Adaptive spatial filtering of multichannel surface electromyogram signals. Med Biol Eng Comput 42:825–831PubMedCrossRef
19.
Zurück zum Zitat Petitjean M, Maton B (1995) Phonomyogram from single motor units during voluntary isometric contraction. Eur J Appl Physiol 71(2–3):215–222CrossRef Petitjean M, Maton B (1995) Phonomyogram from single motor units during voluntary isometric contraction. Eur J Appl Physiol 71(2–3):215–222CrossRef
20.
Zurück zum Zitat Piancino MG, Isola G, Merlo A, Dalessandri D, Debernardi C, Bracco P (2012) Chewing pattern and muscular activation in open bite patients. J Electromyogr Kinesiol 22:273–279PubMedCrossRef Piancino MG, Isola G, Merlo A, Dalessandri D, Debernardi C, Bracco P (2012) Chewing pattern and muscular activation in open bite patients. J Electromyogr Kinesiol 22:273–279PubMedCrossRef
21.
Zurück zum Zitat Staudenmann D, Kingma I, Daffertshofer A, Stegeman DF, van Dieën JH (2006) Improving EMG-based muscle force estimation by using a high-density EMG grid and principal component analysis. IEEE Trans Biomed Eng 53:712–719PubMedCrossRef Staudenmann D, Kingma I, Daffertshofer A, Stegeman DF, van Dieën JH (2006) Improving EMG-based muscle force estimation by using a high-density EMG grid and principal component analysis. IEEE Trans Biomed Eng 53:712–719PubMedCrossRef
22.
Zurück zum Zitat Watanabe M, Mita K, Akataki K, Itoh Y (2001) Mechanical behavior of condenser microphone in mechanomyography. Med Biol Eng Comput 39:195–201CrossRef Watanabe M, Mita K, Akataki K, Itoh Y (2001) Mechanical behavior of condenser microphone in mechanomyography. Med Biol Eng Comput 39:195–201CrossRef
23.
Zurück zum Zitat Watanabe Mita K, Akataki K, Itoh K (2003) Reliability of the mechanomyogram detected with an accelerometer during voluntary contractions. Med Biol Eng Comput 41:198–202CrossRef Watanabe Mita K, Akataki K, Itoh K (2003) Reliability of the mechanomyogram detected with an accelerometer during voluntary contractions. Med Biol Eng Comput 41:198–202CrossRef
24.
Zurück zum Zitat Xu G, Mao Z, Ye Y, Lv K (2011) Relationship between muscle oxygenation by NIRS and blood lactate. J Phys Conf Ser 227:1–13 Xu G, Mao Z, Ye Y, Lv K (2011) Relationship between muscle oxygenation by NIRS and blood lactate. J Phys Conf Ser 227:1–13
Metadaten
Titel
A new layered sensor for simultaneous measurement of EMG, MMG and oxygen consumption at the same position
verfasst von
Akira Kimoto
Yuji Yamada
Publikationsdatum
01.01.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
Medical & Biological Engineering & Computing / Ausgabe 1/2015
Print ISSN: 0140-0118
Elektronische ISSN: 1741-0444
DOI
https://doi.org/10.1007/s11517-014-1208-0

Weitere Artikel der Ausgabe 1/2015

Medical & Biological Engineering & Computing 1/2015 Zur Ausgabe