Skip to main content

2021 | OriginalPaper | Buchkapitel

Absorbable Wire Radiopacity: Influence of Composition and Size on X-ray Visibility

verfasst von : Adam J. Griebel, Aubrey L. Ehle, Jeremy E. Schaffer

Erschienen in: Magnesium Technology 2021

Verlag: Springer International Publishing

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Imaging systems employing X-rays (such a 2D projectional radiography, computed tomography, and fluoroscopy) are widely used in medicine to aid in surgical planning, intervention, and follow up. Visualization of medical devices using these techniques relies on differences in x-ray absorption between the medical device and the surrounding tissue. The amount of absorption of a given device is largely a function of its cross-sectional dimensions, density, and atomic properties. Consequently, imaging of relatively small devices, like stents, made of a low-density material, like magnesium, can be very challenging. The aim of this study is to quantify the relative radiopacities of key absorbable metal alloy systems, determine the influence of magnesium alloy composition on radiopacity, and estimate the diameters at which wires are no longer visible under typical clinical conditions. This is accomplished by producing wires from five different magnesium alloys, a zinc alloy, and an iron alloy, in sizes ranging from 0.2 to 1.0 mm diameter, and imaging on a clinical x-ray system.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat J. Rosch, F. Keller and J. Kaufman, “The Birth, Early Years, and Future of Interventional Radiology,” Journal of Vascular Interventional Radiology, vol. 14, pp. 841–853, 2003.CrossRef J. Rosch, F. Keller and J. Kaufman, “The Birth, Early Years, and Future of Interventional Radiology,” Journal of Vascular Interventional Radiology, vol. 14, pp. 841–853, 2003.CrossRef
2.
Zurück zum Zitat H. Chen, M. Rogalski and J. Anker, “Advances in functional X-ray imaging techniques and contrast agents,” Physical Chemistry Chemical Physics, no. 39, 2012 H. Chen, M. Rogalski and J. Anker, “Advances in functional X-ray imaging techniques and contrast agents,” Physical Chemistry Chemical Physics, no. 39, 2012
3.
Zurück zum Zitat S. A. M. Tofail, J. M. Carlson, A. A. Gandhi, J. Butler, P. Tiernan and L. O’Donoghue, “Nickel-titanium-rare earth alloy and method of processing the alloy”. USA Patent 8,440,031 B2, 2013 S. A. M. Tofail, J. M. Carlson, A. A. Gandhi, J. Butler, P. Tiernan and L. O’Donoghue, “Nickel-titanium-rare earth alloy and method of processing the alloy”. USA Patent 8,440,031 B2, 2013
4.
Zurück zum Zitat X.-m. Li and e. al, “Evaluation of peripheral artery stent with 64-slice multi-detector row CT angiography: prospective comparison with digital subtraction angiography,” European Journal of Radiology, vol. 75, no. 1, pp. 98–103, 2010 X.-m. Li and e. al, “Evaluation of peripheral artery stent with 64-slice multi-detector row CT angiography: prospective comparison with digital subtraction angiography,” European Journal of Radiology, vol. 75, no. 1, pp. 98–103, 2010
5.
Zurück zum Zitat A. Kastrati, J. Mehilli and et al, “Intracoronary Stenting and Angiographic Results,” Circulation, vol. 103, pp. 2816–2821, 2001. A. Kastrati, J. Mehilli and et al, “Intracoronary Stenting and Angiographic Results,” Circulation, vol. 103, pp. 2816–2821, 2001.
6.
Zurück zum Zitat R. Noad, C. Hanratty and S. Walsh, “Clinical Impact of Stent Design,” Interventional Cardiology Review, vol. 9, no. 2, pp. 89–93, 2014.CrossRef R. Noad, C. Hanratty and S. Walsh, “Clinical Impact of Stent Design,” Interventional Cardiology Review, vol. 9, no. 2, pp. 89–93, 2014.CrossRef
7.
Zurück zum Zitat G. Rajah, S. Narayanan and L. Rangel-Castilla, “Update on flow diverters for the endovascular,” Neurosurgical Focus, vol. 42, no. 6, 2017. G. Rajah, S. Narayanan and L. Rangel-Castilla, “Update on flow diverters for the endovascular,” Neurosurgical Focus, vol. 42, no. 6, 2017.
8.
Zurück zum Zitat P. Maier, A. Steinacker, B. Clausius and N. Hort, “Influence of Solution Heat Treatment on the Microstructure Hardness and Stress Corrosion Behavior of Extruded Resoloy(R),” JOM, pp. 1870–1879, 2020 P. Maier, A. Steinacker, B. Clausius and N. Hort, “Influence of Solution Heat Treatment on the Microstructure Hardness and Stress Corrosion Behavior of Extruded Resoloy(R),” JOM, pp. 1870–1879, 2020
9.
Zurück zum Zitat A. Griebel, “An in vitro and in vivo characterization of fine WE43B magnesium wire with varied thermomechanical processing conditions,” Journal of Biomedical Materials Research Part B: Applied Biomaterials, 2017 A. Griebel, “An in vitro and in vivo characterization of fine WE43B magnesium wire with varied thermomechanical processing conditions,” Journal of Biomedical Materials Research Part B: Applied Biomaterials, 2017
10.
Zurück zum Zitat M. Stekker, N. Hort, F. Feyerabend, E. Hoffmann, M. Hoffmann and R. Horres, “Resorbable stents which contain a magnesium alloy”. USA Patent 9522219 B2, 2016 M. Stekker, N. Hort, F. Feyerabend, E. Hoffmann, M. Hoffmann and R. Horres, “Resorbable stents which contain a magnesium alloy”. USA Patent 9522219 B2, 2016
11.
Zurück zum Zitat Y. Zheng, X. Gu and F. Witte, “Biodegradable Metals,” Materials Science and Engineering R, vol. 77, pp. 1–34, 2015CrossRef Y. Zheng, X. Gu and F. Witte, “Biodegradable Metals,” Materials Science and Engineering R, vol. 77, pp. 1–34, 2015CrossRef
12.
Zurück zum Zitat M. Sikora-Jasinska, “Fabrication, mechanical properties and in vitro degradation behavior of newly developed Zn-Ag alloys for degradable implant applications,” Materials Science and Engineering: C, pp. 1170–1181, 2017 M. Sikora-Jasinska, “Fabrication, mechanical properties and in vitro degradation behavior of newly developed Zn-Ag alloys for degradable implant applications,” Materials Science and Engineering: C, pp. 1170–1181, 2017
13.
Zurück zum Zitat J. Schaffer, “Cold drawn bioabsorbable ferrous and ferrous composite wires: An evaluation of in vitro vascular cytocompatibility,” Acta Biomaterialia, pp. 8574–8584, 2013 J. Schaffer, “Cold drawn bioabsorbable ferrous and ferrous composite wires: An evaluation of in vitro vascular cytocompatibility,” Acta Biomaterialia, pp. 8574–8584, 2013
14.
Zurück zum Zitat Sonnow, “Biodegradable magnesium Herbert screw – image quality and artifacts with radiography, CT and MRI,” BMC Medical Imaging, 2017 Sonnow, “Biodegradable magnesium Herbert screw – image quality and artifacts with radiography, CT and MRI,” BMC Medical Imaging, 2017
15.
Zurück zum Zitat J. Espiritu, J. Seitz and M. Meier, “The performance of Mg-based implants in MRI: a systematic review,” in Updates in Bioabsorbable Metals, Virtual, 2020 J. Espiritu, J. Seitz and M. Meier, “The performance of Mg-based implants in MRI: a systematic review,” in Updates in Bioabsorbable Metals, Virtual, 2020
16.
Zurück zum Zitat ASTM International, F640: Standard Test Methods for Determining Radiopacity for Medical Use, 2012 ASTM International, F640: Standard Test Methods for Determining Radiopacity for Medical Use, 2012
Metadaten
Titel
Absorbable Wire Radiopacity: Influence of Composition and Size on X-ray Visibility
verfasst von
Adam J. Griebel
Aubrey L. Ehle
Jeremy E. Schaffer
Copyright-Jahr
2021
DOI
https://doi.org/10.1007/978-3-030-65528-0_17

    Marktübersichten

    Die im Laufe eines Jahres in der „adhäsion“ veröffentlichten Marktübersichten helfen Anwendern verschiedenster Branchen, sich einen gezielten Überblick über Lieferantenangebote zu verschaffen.