Preliminary work was presented at the 10th International Conference on Structures in Fire: Jeanneret, C., Gales, J., Kotsovinos, P., and Rein G. (June 2018) Design of Post tensioned Concrete Structures Exposed to Travelling Fires. Proceedings of the 10th International Conference on Structures in Fire. Ulster, UK. 8 pp.

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Abstract

Modern architecture is striving for large open spaces, which has resulted in the development of design methodologies such as the Improved Travelling Fires Methodology (iTFM). This methodology is only applicable in large open spaces where flashover may not occur. This paper studies the effect of various design fires, including traditional uniform fires and for the first time iTFM on flat-plate unbonded post-tensioned (UPT) concrete, a structural system which allows long flooring spans (> 8 m). The predictions of a structural model of high temperature unbonded prestressing tendon relaxation that is available in the literature are compared for the first time with previously published fire experiments thus validating the model. A novel case study based on a real building was then analysed using the model to propose an acceptance criterion based on the longest tendon length where rupture and extreme stress relaxation is prevented. Two types of steel, fabricated according to BS 5896 and AS/NZ4672, were analysed for various unbonded lengths (between 8.15 m and 65.2 m). Emphasis is on the unique deformation mechanisms present when prestressing steel is heated locally. The relaxation model has been validated for negligible slab deflection, allowing for discussion on the difference between the impact of travelling and uniform fires on the design of UPT concrete. The tendon rupture and relaxation analysis have novelty in showing that slow moving fires are more onerous structurally than fast moving or uniform fires and therefore are important to consider when defining critical design thermal boundaries in a design context. Results also demonstrate that tendons in similar designs require consideration to be limited in unbonded length. The development of new acceptance criteria herein is the first step in producing a generalized criteria for better informed structural fire design of UPT concrete exposed to fire.

Bitte loggen Sie sich ein, um Zugang zu diesem Inhalt zu erhalten

Sie möchten Zugang zu diesem Inhalt erhalten? Dann informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 50.000 Bücher
  • über 380 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Umwelt
  • Maschinenbau + Werkstoffe




Testen Sie jetzt 30 Tage kostenlos.

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 69.000 Bücher
  • über 500 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Umwelt
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Testen Sie jetzt 30 Tage kostenlos.

Literatur
Über diesen Artikel

Weitere Artikel der Ausgabe 3/2020

Fire Technology 3/2020 Zur Ausgabe