Abstract

It is widely accepted that the service life of transformer oil–paper insulation is determined by the aging condition of transformer cellulosic insulation. Therefore, it is rather meaningful to accurately and reliably evaluate the aging condition of transformer cellulose insulation. Existing studies have shown that activation energy can eliminate the temperature effect on the frequency dielectric spectroscopy, however, the traditional activation energy might not be suitable for assessing the aging condition of transformer cellulosic insulation. The aim of the work is to assess the aging condition of cellulosic insulation by using average activation energy technique. The experiment process is firstly discussed. Then, the second-order dynamic equation formed by Arrhenius equation and Ekenstam equation is strictly investigated to accurately calculate the degree of polymerization value of transformer cellulosic insulation. The experimental results preliminarily show that the average activation energy can effectively assess aging condition of transformer cellulosic insulation.

Graphical abstract

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Literatur
Zurück zum Zitat Abu-Siada A, Lai S, Islam S (2012) A novel fuzzy-logic approach for furan estimation in transformer oil. IEEE Trans Power Deliv 27:469–474CrossRef Abu-Siada A, Lai S, Islam S (2012) A novel fuzzy-logic approach for furan estimation in transformer oil. IEEE Trans Power Deliv 27:469–474CrossRef
Zurück zum Zitat Arroyo OH, Fofana I, Jalbert J, Ryadi M (2015) Relationships between methanol marker and mechanical performance of electrical insulation papers for power transformers under accelerated thermal aging. IEEE Trans Dielectr Electr Insul 22(6):3625–3632CrossRef Arroyo OH, Fofana I, Jalbert J, Ryadi M (2015) Relationships between methanol marker and mechanical performance of electrical insulation papers for power transformers under accelerated thermal aging. IEEE Trans Dielectr Electr Insul 22(6):3625–3632CrossRef
Zurück zum Zitat Arroyo OH, Jalbert J, Fofana I, Ryadi M (2017) Temperature dependence of methanol and the tensile strength of insulation paper: kinetics of the changes of mechanical properties during ageing. Cellul J Article 24(2):1031–1039CrossRef Arroyo OH, Jalbert J, Fofana I, Ryadi M (2017) Temperature dependence of methanol and the tensile strength of insulation paper: kinetics of the changes of mechanical properties during ageing. Cellul J Article 24(2):1031–1039CrossRef
Zurück zum Zitat Ekenstam A (1936) The behavior of cellulose in mineral acid solutions: kinetic study of the decomposition of cellulose in acid solutions. BER 69:540–553 Ekenstam A (1936) The behavior of cellulose in mineral acid solutions: kinetic study of the decomposition of cellulose in acid solutions. BER 69:540–553
Zurück zum Zitat Emsley AM, Heywood RJ (1997) On the kinetics of degradation of cellulose. Cellulose 4:1–5CrossRef Emsley AM, Heywood RJ (1997) On the kinetics of degradation of cellulose. Cellulose 4:1–5CrossRef
Zurück zum Zitat Emsley AM, Stevens GC (1994) Kinetics and mechanisms of the low-temperature degradation of cellulose. Cellulose 1:26–56CrossRef Emsley AM, Stevens GC (1994) Kinetics and mechanisms of the low-temperature degradation of cellulose. Cellulose 1:26–56CrossRef
Zurück zum Zitat Emsley AM, Xiao X, Heywood R (2000) Degradation of cellulosic insulation in power transformers. Part 2: formation of furan products in insulating oil. IEE Proc Sci Meas Technol 147:110–114CrossRef Emsley AM, Xiao X, Heywood R (2000) Degradation of cellulosic insulation in power transformers. Part 2: formation of furan products in insulating oil. IEE Proc Sci Meas Technol 147:110–114CrossRef
Zurück zum Zitat Fofana I, Hemmatjou H, Meghnefi F (2011) Effect of thermal transient on the polarization and depolarization current measurements of oil–paper insulation. IEEE Trans Dielectr Electr Insul 18:513–520CrossRef Fofana I, Hemmatjou H, Meghnefi F (2011) Effect of thermal transient on the polarization and depolarization current measurements of oil–paper insulation. IEEE Trans Dielectr Electr Insul 18:513–520CrossRef
Zurück zum Zitat Gao J, Yang LJ, Wang YY (2016) Effect of moisture and thermal degradation on the activation energy of oil–paper insulation in frequency domain spectroscope measurement. IET Gener Transm Distrib 10:2042–2049CrossRef Gao J, Yang LJ, Wang YY (2016) Effect of moisture and thermal degradation on the activation energy of oil–paper insulation in frequency domain spectroscope measurement. IET Gener Transm Distrib 10:2042–2049CrossRef
Zurück zum Zitat Jalbert J, Gilbert R, Denos Y, Gervais P (2012) Methanol: a novel approach to power transformer asset management. IEEE Trans Power Deliv 27(2):514–520CrossRef Jalbert J, Gilbert R, Denos Y, Gervais P (2012) Methanol: a novel approach to power transformer asset management. IEEE Trans Power Deliv 27(2):514–520CrossRef
Zurück zum Zitat Jalbert J, Celis ER, Duchesne S, Morin B et al (2015) Kinetics of the production of chain-end groups and methanol from the depolymerization of cellulose during the ageing of paper/oil systems. Part 3: extension of the study under temperature conditions over 120 °C. Cellul J Article 22(1):829–848CrossRef Jalbert J, Celis ER, Duchesne S, Morin B et al (2015) Kinetics of the production of chain-end groups and methanol from the depolymerization of cellulose during the ageing of paper/oil systems. Part 3: extension of the study under temperature conditions over 120 °C. Cellul J Article 22(1):829–848CrossRef
Zurück zum Zitat Jinscher AK (1996) Dielectric relaxation in solids. J Phys D Appl Phys 32(14):57–70CrossRef Jinscher AK (1996) Dielectric relaxation in solids. J Phys D Appl Phys 32(14):57–70CrossRef
Zurück zum Zitat Koch M, Prevost T (2012) Analysis of dielectric response measurements for condition assessment of oil–paper transformer insulation. IEEE Trans Dielectr Electr Insul 19:1908–1915CrossRef Koch M, Prevost T (2012) Analysis of dielectric response measurements for condition assessment of oil–paper transformer insulation. IEEE Trans Dielectr Electr Insul 19:1908–1915CrossRef
Zurück zum Zitat Koufakis E, Halevidis C, Polykrati A (2012) Calculation of the activation energy of oil–paper insulation in a distribution transformer. IEEE Electr Insul Mag 28:52–58CrossRef Koufakis E, Halevidis C, Polykrati A (2012) Calculation of the activation energy of oil–paper insulation in a distribution transformer. IEEE Electr Insul Mag 28:52–58CrossRef
Zurück zum Zitat Lelekakis N, Martin D, Wijaya J (2012a) Ageing rate of paper insulation used in power transformers. Part 1: oil/paper system with low oxygen concentration. IEEE Trans Dielectr Electr Insul 19:1999–2008CrossRef Lelekakis N, Martin D, Wijaya J (2012a) Ageing rate of paper insulation used in power transformers. Part 1: oil/paper system with low oxygen concentration. IEEE Trans Dielectr Electr Insul 19:1999–2008CrossRef
Zurück zum Zitat Lelekakis N, Martin D, Wijaya J (2012b) Ageing rate of paper insulation used in power transformers. Part 2: oil/paper system with medium and high oxygen concentration. IEEE Trans Dielectr Electr Insul 19:2009–2018CrossRef Lelekakis N, Martin D, Wijaya J (2012b) Ageing rate of paper insulation used in power transformers. Part 2: oil/paper system with medium and high oxygen concentration. IEEE Trans Dielectr Electr Insul 19:2009–2018CrossRef
Zurück zum Zitat Liao RJ, Sun HG, Gong J et al (2011) Ageing kinetic model and life time model of oil–paper insulation in transformers. High Volt Eng 37:1576–1583 (in Chinese) Liao RJ, Sun HG, Gong J et al (2011) Ageing kinetic model and life time model of oil–paper insulation in transformers. High Volt Eng 37:1576–1583 (in Chinese)
Zurück zum Zitat Liao RJ, Hao J, Chen G, Yang LJ (2012) Quantitative analysis of ageing condition of oil–paper insulation by frequency domain spectroscopy. IEEE Trans Dielectr Electr Insul 19:821–830CrossRef Liao RJ, Hao J, Chen G, Yang LJ (2012) Quantitative analysis of ageing condition of oil–paper insulation by frequency domain spectroscopy. IEEE Trans Dielectr Electr Insul 19:821–830CrossRef
Zurück zum Zitat Liao RJ, Liu JF, Yang LJ et al (2015a) Quantitative analysis of insulation condition of oil–paper insulation based on frequency domain spectroscopy. IEEE Trans Dielecctr Electr Insul 22:322–334CrossRef Liao RJ, Liu JF, Yang LJ et al (2015a) Quantitative analysis of insulation condition of oil–paper insulation based on frequency domain spectroscopy. IEEE Trans Dielecctr Electr Insul 22:322–334CrossRef
Zurück zum Zitat Liao RJ, Liu JF, Yang LJ, Gao J, Zhang YY, Lv Y, Zheng H (2015b) Understanding and analysis on frequency dielectric parameter for quantitative diagnosis of moisture content in paper–oil insulation system. IET Electr Power Appl 9:213–222CrossRef Liao RJ, Liu JF, Yang LJ, Gao J, Zhang YY, Lv Y, Zheng H (2015b) Understanding and analysis on frequency dielectric parameter for quantitative diagnosis of moisture content in paper–oil insulation system. IET Electr Power Appl 9:213–222CrossRef
Zurück zum Zitat Liao RJ, Liu JF, Yang LJ et al (2015c) Extraction of frequency domain dielectric characteristic parameter of oil–paper insulation for transformer condition assessment. Electr Power Compon Syst 43:578–587CrossRef Liao RJ, Liu JF, Yang LJ et al (2015c) Extraction of frequency domain dielectric characteristic parameter of oil–paper insulation for transformer condition assessment. Electr Power Compon Syst 43:578–587CrossRef
Zurück zum Zitat Linhjell D, Lundgaard LE, Gafvert U (2007) Dielectric response of mineral oil impregnated cellulose and the impact of aging. IEEE Trans Dielectr Electr Insul 14:156–169CrossRef Linhjell D, Lundgaard LE, Gafvert U (2007) Dielectric response of mineral oil impregnated cellulose and the impact of aging. IEEE Trans Dielectr Electr Insul 14:156–169CrossRef
Zurück zum Zitat Liu JF, Liao RJ, Zhang Y, Gong C, Wang C, Gao J (2015) Condition evaluation for aging state of transformer oil–paper insulation based on time-frequency domain dielectric characteristics. Electr Power Compon Syst 43:759–769CrossRef Liu JF, Liao RJ, Zhang Y, Gong C, Wang C, Gao J (2015) Condition evaluation for aging state of transformer oil–paper insulation based on time-frequency domain dielectric characteristics. Electr Power Compon Syst 43:759–769CrossRef
Zurück zum Zitat Liu JF, Zheng HB, Zhang YY, Wei H, Liao RJ (2017) Grey relational analysis for insulation condition assessment of power transformers based upon conventional dielectric response measurement. Energies 10:1526CrossRef Liu JF, Zheng HB, Zhang YY, Wei H, Liao RJ (2017) Grey relational analysis for insulation condition assessment of power transformers based upon conventional dielectric response measurement. Energies 10:1526CrossRef
Zurück zum Zitat Liu JF, Zheng HB, Zhang YY (2018) Comparative investigation on the performance of modified system poles and traditional system poles obtained from PDC data for diagnosing the aging condition of transformer polymer insulation materials. Polymers 10:191CrossRefPubMedCentral Liu JF, Zheng HB, Zhang YY (2018) Comparative investigation on the performance of modified system poles and traditional system poles obtained from PDC data for diagnosing the aging condition of transformer polymer insulation materials. Polymers 10:191CrossRefPubMedCentral
Zurück zum Zitat Mukherjee M, Pradhan AK, Baral A, Chakravorti S (2017) A modified Maxwell model for modeling dielectric response of oil–paper insulation affected by radial and axial temperature gradients. IEEE Trans Dielectr Electr Insul 24:1000–1009CrossRef Mukherjee M, Pradhan AK, Baral A, Chakravorti S (2017) A modified Maxwell model for modeling dielectric response of oil–paper insulation affected by radial and axial temperature gradients. IEEE Trans Dielectr Electr Insul 24:1000–1009CrossRef
Zurück zum Zitat Prevost TA, Oommen TV (2006) Cellulose insulation in oil-filled power transformers: part I—history and development. IEEE Electr Insul Mag 22(1):28–35CrossRef Prevost TA, Oommen TV (2006) Cellulose insulation in oil-filled power transformers: part I—history and development. IEEE Electr Insul Mag 22(1):28–35CrossRef
Zurück zum Zitat Rodriguez-Celis EM, Duchesne S, Jalbert J, Ryadi M (2015) Understanding ethanol versus methanol formation from insulating paper in power transformers. Cellulose 22:3225–3236CrossRef Rodriguez-Celis EM, Duchesne S, Jalbert J, Ryadi M (2015) Understanding ethanol versus methanol formation from insulating paper in power transformers. Cellulose 22:3225–3236CrossRef
Zurück zum Zitat Saha TK (2003) Review of modern diagnostic techniques for assessing insulation condition in aged transformers. IEEE Trans Dielectr Electr Insul 10:903–917CrossRef Saha TK (2003) Review of modern diagnostic techniques for assessing insulation condition in aged transformers. IEEE Trans Dielectr Electr Insul 10:903–917CrossRef
Zurück zum Zitat Saha TK, Purkait P (2008) Understanding the impacts of moisture and thermal aging on transformer’s insulation by dielectric response and molecular weight measurements. IEEE Trans Dielectr Electr Insul 15(2):568–582CrossRef Saha TK, Purkait P (2008) Understanding the impacts of moisture and thermal aging on transformer’s insulation by dielectric response and molecular weight measurements. IEEE Trans Dielectr Electr Insul 15(2):568–582CrossRef
Zurück zum Zitat Shi J, Wu CN, Wang XJ (2015) Life evaluation of insulation paper used in transformer by determining the activation energy. Mater Res Innov 19:164–167CrossRef Shi J, Wu CN, Wang XJ (2015) Life evaluation of insulation paper used in transformer by determining the activation energy. Mater Res Innov 19:164–167CrossRef
Zurück zum Zitat Tang C, Zhang S, Wang X, Hao J (2018) Enhanced mechanical properties and thermal stability of cellulose insulation paper achieved by doping with melamine-grafted nano-SiO2. Cellulose 25(6):3619–3633CrossRef Tang C, Zhang S, Wang X, Hao J (2018) Enhanced mechanical properties and thermal stability of cellulose insulation paper achieved by doping with melamine-grafted nano-SiO2. Cellulose 25(6):3619–3633CrossRef
Zurück zum Zitat Thakur S, Sarathi R, Gautam R, Vinu R (2017) Thermal aging of cellulosic pressboard material and its surface discharge and chemical characterization. Cellulose 24:5197–5210CrossRef Thakur S, Sarathi R, Gautam R, Vinu R (2017) Thermal aging of cellulosic pressboard material and its surface discharge and chemical characterization. Cellulose 24:5197–5210CrossRef
Zurück zum Zitat Verma HC, Baral A, Pradhan AK, Chakravorti SA (2017) A method to estimate activation energy of power transformer insulation using time domain spectroscopy data. IEEE Trans Power Deliv 24:3245–3253 Verma HC, Baral A, Pradhan AK, Chakravorti SA (2017) A method to estimate activation energy of power transformer insulation using time domain spectroscopy data. IEEE Trans Power Deliv 24:3245–3253
Zurück zum Zitat Wada J, Ueta G, Okabe S (2014) Method to evaluate the degradation condition of transformer insulating oil-experimental study on the hydrophilic and dissociative properties of degradation products. IEEE Trans Dielectr Electr Insul 21:873–881CrossRef Wada J, Ueta G, Okabe S (2014) Method to evaluate the degradation condition of transformer insulating oil-experimental study on the hydrophilic and dissociative properties of degradation products. IEEE Trans Dielectr Electr Insul 21:873–881CrossRef
Zurück zum Zitat Wang L, Tang C, Zhu S, Zhou S (2018) Terahertz time domain spectroscopy of transformer insulation paper after thermal aging intervals. Materials 11(11):2124CrossRefPubMedCentral Wang L, Tang C, Zhu S, Zhou S (2018) Terahertz time domain spectroscopy of transformer insulation paper after thermal aging intervals. Materials 11(11):2124CrossRefPubMedCentral
Zurück zum Zitat Yang LJ, Peng P, Gao J, Liu X (2018) The range recognition of moisture and aging status of oil–paper insulation based on frequency domain dielectric response characteristic fingerprint. Trans China Electrotech Soc 33:2105–2114 Yang LJ, Peng P, Gao J, Liu X (2018) The range recognition of moisture and aging status of oil–paper insulation based on frequency domain dielectric response characteristic fingerprint. Trans China Electrotech Soc 33:2105–2114
Zurück zum Zitat Zhang YY, Liu JF, Zheng HB, Wei H, Lian RJ (2017) Study on quantitative correlations between the ageing condition of transformer cellulose insulation and the large time constant obtained from the extended debye model. Energies 10:1842CrossRef Zhang YY, Liu JF, Zheng HB, Wei H, Lian RJ (2017) Study on quantitative correlations between the ageing condition of transformer cellulose insulation and the large time constant obtained from the extended debye model. Energies 10:1842CrossRef
Zurück zum Zitat Zhang YY, Liu JF, Zheng HB, Wang K (2018a) Feasibility of a universal approach for temperature correction in frequency domain spectroscopy of transformer insulation. IEEE Trans Dielectr Electr Insul 25:1766–1773CrossRef Zhang YY, Liu JF, Zheng HB, Wang K (2018a) Feasibility of a universal approach for temperature correction in frequency domain spectroscopy of transformer insulation. IEEE Trans Dielectr Electr Insul 25:1766–1773CrossRef
Zurück zum Zitat Zhang DN, Yun H, Zhan JY et al (2018b) Insulation condition diagnosis of oil-immersed paper insulation based on non-linear frequency-domain dielectric response. IEEE Trans Dielectr Electr Insul 25:1980–1988CrossRef Zhang DN, Yun H, Zhan JY et al (2018b) Insulation condition diagnosis of oil-immersed paper insulation based on non-linear frequency-domain dielectric response. IEEE Trans Dielectr Electr Insul 25:1980–1988CrossRef
Zurück zum Zitat Zheng HB, Zhang YY, Liu JF, Wei H, Zhao JH, Liao RJ (2018) A novel model based on wavelet LS-SVM integrated improved PSO algorithm for forecasting of dissolved gas contents in power transformers. Electr Power Syst Res 155:196–205CrossRef Zheng HB, Zhang YY, Liu JF, Wei H, Zhao JH, Liao RJ (2018) A novel model based on wavelet LS-SVM integrated improved PSO algorithm for forecasting of dissolved gas contents in power transformers. Electr Power Syst Res 155:196–205CrossRef
Metadaten
Titel
Aging condition assessment of transformer oil-immersed cellulosic insulation based upon the average activation energy method
verfasst von
J. Liu
X. Fan
H. Zheng
Y. Zhang
C. Zhang
B. Lai
J. Wang
G. Ren
E. Zhang
Publikationsdatum
02.03.2019
Verlag
Springer Netherlands
Erschienen in
Cellulose / Ausgabe 6/2019
Print ISSN: 0969-0239
Elektronische ISSN: 1572-882X
DOI
https://doi.org/10.1007/s10570-019-02331-1

Weitere Artikel der Ausgabe 6/2019

Cellulose 6/2019 Zur Ausgabe