Abstract

Purpose

Dual-energy computed tomography (DECT) images can undergo a two-material decomposition process which results in two images containing material density information. Material density images obtained by that process result in images with increased pixel noise. Noise reduction in those images is desirable in order to improve image quality.

Methods

A noise reduction algorithm for material density images was developed and tested. A three-level wavelet approach combined with the application of an anisotropic diffusion filter was used. During each level, the resulting noise maps are further processed, until the original resolution is reached and the final noise maps obtained. Our method works in image space and, therefore, can be applied to any type of material density images obtained from any DECT vendor. A quantitative evaluation of the noise-reduced images using the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and 2D noise power spectrum was done to quantify the improvements.

Results

The noise reduction algorithm was applied to a set of images resulting in images with higher SNR and CNR than the raw density images obtained by the decomposition process. The average improvement in terms of SNR gain was about 49 % while CNR gain was about 52 %. The difference between the raw and filtered regions of interest mean values was far from reaching statistical significance (minimum \(p> 0.89\), average \(p> 0.97\)).

Conclusion

We have demonstrated through a series of quantitative analyses that our novel noise reduction algorithm improves the image quality of DECT material density images.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Alvarez R, Seppi E (1979) Comparison of noise and dose in conventional and energy selective computed-tomography. IEEE Trans Nucl Sci 26(2):2853–2855CrossRef Alvarez R, Seppi E (1979) Comparison of noise and dose in conventional and energy selective computed-tomography. IEEE Trans Nucl Sci 26(2):2853–2855CrossRef
2.
Zurück zum Zitat Balda M, Heismann B, Hornegger J (2010) Value-based noise reduction for low-dose dual-energy computed tomography. In: link.springer.com. Springer, Berlin, pp 547–554 Balda M, Heismann B, Hornegger J (2010) Value-based noise reduction for low-dose dual-energy computed tomography. In: link.springer.com. Springer, Berlin, pp 547–554
3.
Zurück zum Zitat Borsdorf A, Raupach R, Flohr T, Hornegger J (2008) Wavelet based noise reduction in CT-images using correlation analysis. Med Imaging IEEE Trans 27(12):1685–1703CrossRef Borsdorf A, Raupach R, Flohr T, Hornegger J (2008) Wavelet based noise reduction in CT-images using correlation analysis. Med Imaging IEEE Trans 27(12):1685–1703CrossRef
4.
Zurück zum Zitat Hinshaw DA, Dobbins JT III (1995) Recent progress in noise reduction and scatter correction in dual-energy imaging. In: Van Metter RL, Beutel J (eds) Medical imaging. SPIE, pp 134–142 Hinshaw DA, Dobbins JT III (1995) Recent progress in noise reduction and scatter correction in dual-energy imaging. In: Van Metter RL, Beutel J (eds) Medical imaging. SPIE, pp 134–142
5.
Zurück zum Zitat Hsieh J (2003) Computed tomography. In: Principles, design, artifacts, and recent advances. Society of photo optical Hsieh J (2003) Computed tomography. In: Principles, design, artifacts, and recent advances. Society of photo optical
6.
Zurück zum Zitat Hsieh J, Thibault JB et al (2010) Methods and apparatus for noise estimation for multi-resolution anisotropic diffusion filtering. US Patent 7,706,497 Hsieh J, Thibault JB et al (2010) Methods and apparatus for noise estimation for multi-resolution anisotropic diffusion filtering. US Patent 7,706,497
7.
Zurück zum Zitat Huda W, Scalzetti EM, Levin G (2000) Technique factors and image quality as functions of patient weight at abdominal CT1. Radiology 217(2):430–435PubMedCrossRef Huda W, Scalzetti EM, Levin G (2000) Technique factors and image quality as functions of patient weight at abdominal CT1. Radiology 217(2):430–435PubMedCrossRef
8.
Zurück zum Zitat Joshi M, Langan D, Sahani D, Kambadakone A, Aluri S, Procknow K, Wu X, Bhotika R, Okerlund D, Kulkarni N, et al. (2010) Effective atomic number accuracy for kidney stone characterization using spectral CT. In: SPIE medical imaging. International society for optics and photonics, pp 76,223K–76,223K Joshi M, Langan D, Sahani D, Kambadakone A, Aluri S, Procknow K, Wu X, Bhotika R, Okerlund D, Kulkarni N, et al. (2010) Effective atomic number accuracy for kidney stone characterization using spectral CT. In: SPIE medical imaging. International society for optics and photonics, pp 76,223K–76,223K
9.
Zurück zum Zitat Kalender W, Klotz E, Kostaridou L (1988) An algorithm for noise suppression in dual energy CT material density images. Med Imaging IEEE Trans 7(3):218–224CrossRef Kalender W, Klotz E, Kostaridou L (1988) An algorithm for noise suppression in dual energy CT material density images. Med Imaging IEEE Trans 7(3):218–224CrossRef
10.
Zurück zum Zitat Kalender WA (2011) Computed tomography: fundamentals, system technology, image quality, applications. Wiley, New York Kalender WA (2011) Computed tomography: fundamentals, system technology, image quality, applications. Wiley, New York
11.
Zurück zum Zitat Landry G, DeBlois F, Bazalova M, Verhaegen F (2009) MO-D-303A-06: ImaSim, an animated tool for teaching imaging. Med Phys 36(6):2696–2697 Landry G, DeBlois F, Bazalova M, Verhaegen F (2009) MO-D-303A-06: ImaSim, an animated tool for teaching imaging. Med Phys 36(6):2696–2697
12.
Zurück zum Zitat Landry G, Granton PV, Reniers B, Öllers MC, Beaulieu L, Wildberger JE, Verhaegen F (2011) Simulation study on potential accuracy gains from dual energy ct tissue segmentation for low-energy brachytherapy monte carlo dose calculations. Phys Med Biol 56(19):6257PubMedCrossRef Landry G, Granton PV, Reniers B, Öllers MC, Beaulieu L, Wildberger JE, Verhaegen F (2011) Simulation study on potential accuracy gains from dual energy ct tissue segmentation for low-energy brachytherapy monte carlo dose calculations. Phys Med Biol 56(19):6257PubMedCrossRef
13.
Zurück zum Zitat Landry G, Reniers B, Granton PV, van Rooijen B, Beaulieu L, Wildberger JE, Verhaegen F (2011) Extracting atomic numbers and electron densities from a dual source dual energy ct scanner: experiments and a simulation model. Radiother Oncol 100(3):375–379PubMedCrossRef Landry G, Reniers B, Granton PV, van Rooijen B, Beaulieu L, Wildberger JE, Verhaegen F (2011) Extracting atomic numbers and electron densities from a dual source dual energy ct scanner: experiments and a simulation model. Radiother Oncol 100(3):375–379PubMedCrossRef
14.
Zurück zum Zitat Li B, Yadava G, Hsieh J (2011) Quantification of head and body CTDIVOL of dual-energy X-ray CT with fast-kVp switching. Med Phys 38(5):2595–2601PubMedCrossRef Li B, Yadava G, Hsieh J (2011) Quantification of head and body CTDIVOL of dual-energy X-ray CT with fast-kVp switching. Med Phys 38(5):2595–2601PubMedCrossRef
15.
Zurück zum Zitat Li X, Chen T (1994) Nonlinear diffusion with multiple edginess thresholds. Pattern Recognit 27(8):1029–1037CrossRef Li X, Chen T (1994) Nonlinear diffusion with multiple edginess thresholds. Pattern Recognit 27(8):1029–1037CrossRef
16.
Zurück zum Zitat Macovski A, Nishimura DG, Doost-Hoseini A, Brody WR (1983) Measurement-dependent filtering: a novel approach to improved SNR. IEEE Trans Med Imaging 2(3):122–127PubMedCrossRef Macovski A, Nishimura DG, Doost-Hoseini A, Brody WR (1983) Measurement-dependent filtering: a novel approach to improved SNR. IEEE Trans Med Imaging 2(3):122–127PubMedCrossRef
17.
Zurück zum Zitat Park KK, Oh CH, Akay M (2011) Image enhancement by spectral-error correction for dual-energy computed tomography. In: 2011 33rd Annual international conference of the IEEE engineering in medicine and biology society. IEEE, pp 8491–8494 Park KK, Oh CH, Akay M (2011) Image enhancement by spectral-error correction for dual-energy computed tomography. In: 2011 33rd Annual international conference of the IEEE engineering in medicine and biology society. IEEE, pp 8491–8494
18.
Zurück zum Zitat Park, KK, Pavlicek W, Boltz T, Paden R, Hara A, Akay M (2009) Image-based dual energy CT improvements using Gram–Schmidt method. In: Samei E, Hsieh J (eds) SPIE medical imaging. SPIE, pp 72,583S–72,583S-9 Park, KK, Pavlicek W, Boltz T, Paden R, Hara A, Akay M (2009) Image-based dual energy CT improvements using Gram–Schmidt method. In: Samei E, Hsieh J (eds) SPIE medical imaging. SPIE, pp 72,583S–72,583S-9
19.
Zurück zum Zitat Perona P, Malik J (1990) Scale-space and edge detection using anisotropic diffusion. IEEE Trans Pattern Anal Mach Intell 12(7):629–639CrossRef Perona P, Malik J (1990) Scale-space and edge detection using anisotropic diffusion. IEEE Trans Pattern Anal Mach Intell 12(7):629–639CrossRef
20.
Zurück zum Zitat Petersilka M, Krauss B, Stierstorfer K (2011) Noise reduction in dual-source ct scanning. In: SPIE medical imaging. International society for optics and photonics, pp 79,613Q–79,613Q Petersilka M, Krauss B, Stierstorfer K (2011) Noise reduction in dual-source ct scanning. In: SPIE medical imaging. International society for optics and photonics, pp 79,613Q–79,613Q
21.
Zurück zum Zitat Prewitt JM (1970) Picture processing and psychopictorics, chap. Object enhancement and extraction. Elsevier Prewitt JM (1970) Picture processing and psychopictorics, chap. Object enhancement and extraction. Elsevier
22.
Zurück zum Zitat Qiang Y (2011) Image denoising based on Haar wavelet transform. In: Electronics and optoelectronics (ICEOE) Qiang Y (2011) Image denoising based on Haar wavelet transform. In: Electronics and optoelectronics (ICEOE)
23.
Zurück zum Zitat Johnson TRC, Fink C, Schönberg SO, Reiser MF (eds) (2011) Dual energy CT in clinical practice, vol 201, no 1. Springer, Berlin Johnson TRC, Fink C, Schönberg SO, Reiser MF (eds) (2011) Dual energy CT in clinical practice, vol 201, no 1. Springer, Berlin
24.
Zurück zum Zitat Silva AC, Lawder HJ, Hara A, Kujak J, Pavlicek W (2009) Innovations in CT dose reduction strategy: application of the adaptive statistical iterative reconstruction algorithm. Am J Roentgenol 194(1):191–199CrossRef Silva AC, Lawder HJ, Hara A, Kujak J, Pavlicek W (2009) Innovations in CT dose reduction strategy: application of the adaptive statistical iterative reconstruction algorithm. Am J Roentgenol 194(1):191–199CrossRef
25.
Zurück zum Zitat Tsiotsios C, Petrou M (2013) On the choice of the parameters for anisotropic diffusion in image processing. Pattern Recognit 46(5):1369–1381 Tsiotsios C, Petrou M (2013) On the choice of the parameters for anisotropic diffusion in image processing. Pattern Recognit 46(5):1369–1381
26.
Zurück zum Zitat Warp RJ, Dobbins JT (2003) Quantitative evaluation of noise reduction strategies in dual-energy imaging. Med Phys 30(2):190–198PubMedCrossRef Warp RJ, Dobbins JT (2003) Quantitative evaluation of noise reduction strategies in dual-energy imaging. Med Phys 30(2):190–198PubMedCrossRef
27.
Zurück zum Zitat Watanabe Y (1999) Derivation of linear attenuation coefficients from ct numbers for low-energy photons. Phys Med Biol 44(9):2201 Watanabe Y (1999) Derivation of linear attenuation coefficients from ct numbers for low-energy photons. Phys Med Biol 44(9):2201
28.
Zurück zum Zitat Wu X, Langan DA, Xu D, Benson TM et al (2009) Monochromatic CT image representation via fast switching dual kVp. Proc SPIE 7258(725):845 Wu X, Langan DA, Xu D, Benson TM et al (2009) Monochromatic CT image representation via fast switching dual kVp. Proc SPIE 7258(725):845
29.
Zurück zum Zitat Xu D, Langan DA, Wu X, Pack JD (2010) Method and system for correlated noise suppression in dual energy imaging. US Patent Office Xu D, Langan DA, Wu X, Pack JD (2010) Method and system for correlated noise suppression in dual energy imaging. US Patent Office
30.
Zurück zum Zitat Zbijewski W, Gang G, Wang A, Stayman J, Taguchi K, Carrino J, Siewerdsen J (2013) Noise reduction in material decomposition for low-dose dual-energy cone-beam CT In: SPIE medical imaging. International society for optics and photonics, pp 866,819–866,819 Zbijewski W, Gang G, Wang A, Stayman J, Taguchi K, Carrino J, Siewerdsen J (2013) Noise reduction in material decomposition for low-dose dual-energy cone-beam CT In: SPIE medical imaging. International society for optics and photonics, pp 866,819–866,819
Metadaten
Titel
An algorithm for noise correction of dual-energy computed tomography material density images
verfasst von
Rafael Simon Maia
Christian Jacob
Amy K. Hara
Alvin C. Silva
William Pavlicek
Mitchell J. Ross
Publikationsdatum
01.01.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
International Journal of Computer Assisted Radiology and Surgery / Ausgabe 1/2015
Print ISSN: 1861-6410
Elektronische ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-014-1006-z

Weitere Artikel der Ausgabe 1/2015

International Journal of Computer Assisted Radiology and Surgery 1/2015 Zur Ausgabe