Skip to main content

2013 | OriginalPaper | Buchkapitel

35. An Automated Breathing Device for Critically Ill Patients

verfasst von : N. Padmasini, J. Archana

Erschienen in: Recent Advancements in System Modelling Applications

Verlag: Springer India

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

In this paper the project titled an automated breathing device for critically ill patients has been discussed. Ambu bag (AB) is a flexible reservoir bag used for artificial ventilation connected by tubing and non-rebreathing valve to a face mask or endo-tracheal tube. It is a hand held device used to provide positive pressure ventilation to a patient who is not breathing or who is breathing inadequately [1]. In ambulances and in emergency wards of hospitals manually operated ambu bag is used. Bagging is necessarily regular in medical emergencies when the patient’s breathing is insufficient or has ceased completely and also to provide mechanical ventilation in preference to mouth to mouth resuscitation. The problems involved in this type of manual ambu bag is that sometimes due to the negligence of the caretakers required quantity of oxygen is not carried over to the lungs, secondly even if the caretakers are alert one cannot assure that they expel a constant quantity of oxygen into the patient’s lungs, thirdly this type of mechanism basically is a stress to the caretakers. To overcome this, an automatic mechanism for administering oxygen into the patient’s body has been developed and tested successfully. This automated ambu bag is economically cheap and gives much comfort to the care takers and the required amount of oxygen can be delivered appropriately according to the need of the patient.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Elsharydah A (2003) Manual resuscitators (ambu bags) can ventilate the lungs adequately despite big subatmospheric pressure in the breathing circuit. Internet J Anesthesiol 7(2):6 Elsharydah A (2003) Manual resuscitators (ambu bags) can ventilate the lungs adequately despite big subatmospheric pressure in the breathing circuit. Internet J Anesthesiol 7(2):6
2.
Zurück zum Zitat (1983) A complication of nasogastric tube intubation: pulmonary hemorrhage. Anesthesiology 59(4):356–368 (1983) A complication of nasogastric tube intubation: pulmonary hemorrhage. Anesthesiology 59(4):356–368
3.
Zurück zum Zitat Capelli J, Ferlo N, Foley A, Smith V, Atlas G (2011) Bioengineering conference (NEBEC), IEEE 37th Annual North East, 1–3 Capelli J, Ferlo N, Foley A, Smith V, Atlas G (2011) Bioengineering conference (NEBEC), IEEE 37th Annual North East, 1–3
4.
Zurück zum Zitat Clementsen HJ (1963) The E. M. O. inhaler and the ambu bag. Br Med J 2(5369):1409 Clementsen HJ (1963) The E. M. O. inhaler and the ambu bag. Br Med J 2(5369):1409
5.
Zurück zum Zitat Finkelstein JA MD (1996) Oral ambu-bag insufflation to remove unilateral nasal foreign bodies. Am J Emerg Med 14(1) Finkelstein JA MD (1996) Oral ambu-bag insufflation to remove unilateral nasal foreign bodies. Am J Emerg Med 14(1)
6.
Zurück zum Zitat Kannan S, Morrow B, Furness G (1999) Tension pneumothorax and pneumomediastinum after nasogastric tube insertion. Anaesthesia 54(10):1012–1013CrossRef Kannan S, Morrow B, Furness G (1999) Tension pneumothorax and pneumomediastinum after nasogastric tube insertion. Anaesthesia 54(10):1012–1013CrossRef
7.
Zurück zum Zitat Mazidi MA, McKinlay RD, Danny causey, Pic microcontroller and embedded systems using assembly and C, Chapter 9 Mazidi MA, McKinlay RD, Danny causey, Pic microcontroller and embedded systems using assembly and C, Chapter 9
9.
Zurück zum Zitat Zwagill LW, Metzeroff KO (1973) Mechanical ventilation comprised by misplacement of nasogastric tube. Respir Care 18:60–61 Zwagill LW, Metzeroff KO (1973) Mechanical ventilation comprised by misplacement of nasogastric tube. Respir Care 18:60–61
10.
Zurück zum Zitat Ramesh G, Narasimharao I, Robinson A (2010) Intelligent engine with micro controller valve actuation and eliminating the cam linkage arrangement, frontiers in automobile and mechanical engineering (FAME), Sathyabama University, Chennai, pp 151–155 Ramesh G, Narasimharao I, Robinson A (2010) Intelligent engine with micro controller valve actuation and eliminating the cam linkage arrangement, frontiers in automobile and mechanical engineering (FAME), Sathyabama University, Chennai, pp 151–155
12.
Zurück zum Zitat Saini S, Taxak S (1997) Malpositioned nasogastric tube: a cause of ventilatory volume loss. Trop Doct 27(2):125 Saini S, Taxak S (1997) Malpositioned nasogastric tube: a cause of ventilatory volume loss. Trop Doct 27(2):125
13.
Zurück zum Zitat Soroker D, Ezri T, Szmuk P (1994) An unusual case of failure to ventilate the lungs. Anaesthesia 49(12):1105 Soroker D, Ezri T, Szmuk P (1994) An unusual case of failure to ventilate the lungs. Anaesthesia 49(12):1105
14.
Zurück zum Zitat Stirt JA, Lewenstein LN (1981) Circle system failure induced by gastric suction. Anesth Intensive Care 9:161–162 Stirt JA, Lewenstein LN (1981) Circle system failure induced by gastric suction. Anesth Intensive Care 9:161–162
15.
Zurück zum Zitat Wood G, Milne B, Spjeda V, Lewis J (1990) Ventilatory failure due to an improperly placed nasogastric tube. J Anaesthesia 37(5):587–588 Wood G, Milne B, Spjeda V, Lewis J (1990) Ventilatory failure due to an improperly placed nasogastric tube. J Anaesthesia 37(5):587–588
Metadaten
Titel
An Automated Breathing Device for Critically Ill Patients
verfasst von
N. Padmasini
J. Archana
Copyright-Jahr
2013
Verlag
Springer India
DOI
https://doi.org/10.1007/978-81-322-1035-1_35