Skip to main content
Erschienen in: Journal of Electronic Testing 2/2020

18.03.2020

An Efficient Algorithm for Optimizing the Test Path of Digital Microfluidic Biochips

verfasst von: Xijun Huang, Chuanpei Xu, Long Zhang

Erschienen in: Journal of Electronic Testing | Ausgabe 2/2020

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Digital microfluidic biochips (DMFBs) have been widely used in biochemical experiments with high safety requirements. To ensure the reliability of the experiment, it is necessary to use test droplets to perform off-line and on-line testing for DMFBs. Previous random search algorithms are not fully combined with heuristic information, which increases the randomness of search progress and thus results in suboptimal test paths. To solve this problem, a new test path optimization method based on priority strategy and genetic algorithm is proposed, which reduces the blindness of test path search and improves the convergence effect of the random search algorithm. In this method, priority levels are randomly assigned to the edges of the chip test model. With the fluid constraints, a test droplet moves to the untraversed adjacent edge with the highest priority. If all adjacent edges have been traversed, Floyd algorithm is used to determine the shortest path from the test droplet to untraversed edges, and guide the test droplet to move along the shortest path. After determining the test path according to priority strategy, the priority level on the test path is optimized by genetic algorithm, so that the length of the path is gradually reduced by iteration. In this paper, a single test droplet is used to test given chips. The experimental results show that the proposed algorithm is efficient, and the shortest path length is equal to the length of the Euler path, indicating that the shortest test path has reached the optimal value. Moreover, for the “deadlock” problem of droplets in on-line testing process, we also provide a solution by using backoff operation.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Weitere Produktempfehlungen anzeigen
Literatur
1.
Zurück zum Zitat Wang Y, Ruan Q, Lei Z, Lin S, Zhu Z, Zhou L, Yang CJ (2018) Highly sensitive and automated SERS-based immunoassay for H5N1 detection with digital microfluidics. Anal Chem 90(8):5224–5231 Wang Y, Ruan Q, Lei Z, Lin S, Zhu Z, Zhou L, Yang CJ (2018) Highly sensitive and automated SERS-based immunoassay for H5N1 detection with digital microfluidics. Anal Chem 90(8):5224–5231
2.
Zurück zum Zitat Liu T, Cheng S, You H, Lee MS, Lee GB (2019) Bacterial detection and identification from human synovial fluids on an integrated microfluidic system. Analyst 144(4):1210–1222 Liu T, Cheng S, You H, Lee MS, Lee GB (2019) Bacterial detection and identification from human synovial fluids on an integrated microfluidic system. Analyst 144(4):1210–1222
3.
Zurück zum Zitat Lakey A, Ali Z, Scott SM, Chebil S, Korri-Youssoufi H, Hunor S, Ohlander A, Kuphal M, Marti JS (2019) Impedimetric array in polymer microfluidic cartridge for low cost point-of-care diagnostics. Biosens Bioelectron 129:147–154 Lakey A, Ali Z, Scott SM, Chebil S, Korri-Youssoufi H, Hunor S, Ohlander A, Kuphal M, Marti JS (2019) Impedimetric array in polymer microfluidic cartridge for low cost point-of-care diagnostics. Biosens Bioelectron 129:147–154
4.
Zurück zum Zitat Sirisha E, Sitaram E, Lisa TN, Scott N, Rajendra S, Vamsee P (2017) Enzymatic functional assays of coagulation using small sample volumes. Lab Med 49(1):47–54 Sirisha E, Sitaram E, Lisa TN, Scott N, Rajendra S, Vamsee P (2017) Enzymatic functional assays of coagulation using small sample volumes. Lab Med 49(1):47–54
5.
Zurück zum Zitat Ben-Yakar A (2019) High-content and high-throughput in vivo drug screening platforms using microfluidics. Assay Drug Dev Technol 17(1):8–13 Ben-Yakar A (2019) High-content and high-throughput in vivo drug screening platforms using microfluidics. Assay Drug Dev Technol 17(1):8–13
6.
Zurück zum Zitat Han B, Zheng G, Wei J, Yang Y, Lu L, Zhang Q, Wang Y (2019) Computer-aided design of microfluidic resistive network using circuit partition and CFD-based optimization and application in microalgae assessment for marine ecological toxicity. Bioprocess Biosyst Eng 42(5):785–797 Han B, Zheng G, Wei J, Yang Y, Lu L, Zhang Q, Wang Y (2019) Computer-aided design of microfluidic resistive network using circuit partition and CFD-based optimization and application in microalgae assessment for marine ecological toxicity. Bioprocess Biosyst Eng 42(5):785–797
7.
Zurück zum Zitat Zhao X, Dong T (2013) A microfluidic device for continuous sensing of systemic acute toxicants in drinking water. Int J Environ Res Public Health 10(12):6748–6763 Zhao X, Dong T (2013) A microfluidic device for continuous sensing of systemic acute toxicants in drinking water. Int J Environ Res Public Health 10(12):6748–6763
8.
Zurück zum Zitat Li Z, Lai KY, Yu PH, Chakrabarty K, Ho TY, Lee CY (2018) Structural and functional test methods for micro-electrode-dot-array digital microfluidic biochips. IEEE T Comput Aid D 37(5):968–981 Li Z, Lai KY, Yu PH, Chakrabarty K, Ho TY, Lee CY (2018) Structural and functional test methods for micro-electrode-dot-array digital microfluidic biochips. IEEE T Comput Aid D 37(5):968–981
9.
Zurück zum Zitat Keszocze O, Niemann P, Friedemann A, Drechsler R (2018) On the complexity of design tasks for digital microfluidic biochips. Microelectron J 78:35–45 Keszocze O, Niemann P, Friedemann A, Drechsler R (2018) On the complexity of design tasks for digital microfluidic biochips. Microelectron J 78:35–45
10.
Zurück zum Zitat Bhattacharya R, Roy P, Rahaman H (2018) Homogeneous droplet routing in DMFB: an enhanced technique for high performance bioassay implementation. Integration 60:74–91 Bhattacharya R, Roy P, Rahaman H (2018) Homogeneous droplet routing in DMFB: an enhanced technique for high performance bioassay implementation. Integration 60:74–91
11.
Zurück zum Zitat Zhao Y, Xu T, Chakrabarty K (2011) Broadcast electrode-addressing and scheduling methods for pin-constrained digital microfluidic biochips. IEEE T Comput Aid D 30(7):986–999 Zhao Y, Xu T, Chakrabarty K (2011) Broadcast electrode-addressing and scheduling methods for pin-constrained digital microfluidic biochips. IEEE T Comput Aid D 30(7):986–999
12.
Zurück zum Zitat Jeong Byung C, Jun OK, Ji Sun Y, Dohyun K, Kyehan R, Sang Kug C (2014) Optimum thickness of hydrophobic layer for operating voltage reduction in EWOD systems. Sensor Actuat A-Phys 215:8–16 Jeong Byung C, Jun OK, Ji Sun Y, Dohyun K, Kyehan R, Sang Kug C (2014) Optimum thickness of hydrophobic layer for operating voltage reduction in EWOD systems. Sensor Actuat A-Phys 215:8–16
13.
Zurück zum Zitat Pollack MG, Shenderov AD, Fair RB (2002) Electrowetting-based actuation of droplets for integrated microfluidics. Lab Chip 2(2):96–101 Pollack MG, Shenderov AD, Fair RB (2002) Electrowetting-based actuation of droplets for integrated microfluidics. Lab Chip 2(2):96–101
14.
Zurück zum Zitat Guan Y, Tong AY, Nikapitiya NY, Jagath B, Moon H (2016) Numerical modeling of microscale droplet dispensing in parallel-plate electrowetting-on-dielectric (EWOD) devices with various reservoir designs. Microfluid Nanofluid 20(2):20–39 Guan Y, Tong AY, Nikapitiya NY, Jagath B, Moon H (2016) Numerical modeling of microscale droplet dispensing in parallel-plate electrowetting-on-dielectric (EWOD) devices with various reservoir designs. Microfluid Nanofluid 20(2):20–39
15.
Zurück zum Zitat Jang L, Hsu C, Chen C (2009) Effect of electrode geometry on performance of EWOD device driven by battery-based system. Biol Ther 11(5):1029–1036 Jang L, Hsu C, Chen C (2009) Effect of electrode geometry on performance of EWOD device driven by battery-based system. Biol Ther 11(5):1029–1036
16.
Zurück zum Zitat Su F, Hwang W, Mukherjee A, Chakrabarty K (2007) Testing and diagnosis of realistic defects in digital microfluidic biochips. J Electron Test 23:219–233 Su F, Hwang W, Mukherjee A, Chakrabarty K (2007) Testing and diagnosis of realistic defects in digital microfluidic biochips. J Electron Test 23:219–233
17.
Zurück zum Zitat Su F, Ozev S, Chakrabarty K (2003) Testing of Droplet-Based Microelectrofluidic Systems. In: Proc. of International Test Conference, Charlotte, NC, United States, pp 1192–1200 Su F, Ozev S, Chakrabarty K (2003) Testing of Droplet-Based Microelectrofluidic Systems. In: Proc. of International Test Conference, Charlotte, NC, United States, pp 1192–1200
18.
Zurück zum Zitat Su F, Ozev S, Chakrabarty K (2006) Concurrent testing of digital microfluidics-based biochips. ACM T Des Automat El 11(2):442–464 Su F, Ozev S, Chakrabarty K (2006) Concurrent testing of digital microfluidics-based biochips. ACM T Des Automat El 11(2):442–464
19.
Zurück zum Zitat Su F, Zeng J (2007) Computer-Aided Design and Test for Digital Microfluidics. IEEE Des Test Comput 24(1):60–70 Su F, Zeng J (2007) Computer-Aided Design and Test for Digital Microfluidics. IEEE Des Test Comput 24(1):60–70
20.
Zurück zum Zitat Su F, Ozev S, Chakrabarty K (2005) Ensuring the operational health of droplet-based microelectrofluidic biosensor systems. IEEE Sensors J 5(4):763–773 Su F, Ozev S, Chakrabarty K (2005) Ensuring the operational health of droplet-based microelectrofluidic biosensor systems. IEEE Sensors J 5(4):763–773
21.
Zurück zum Zitat Su F, Ozev S, Chakrabarty K (2006) Test planning and test resource optimization for droplet-based microfluidic systems. J Electron Test 22(2):199–210 Su F, Ozev S, Chakrabarty K (2006) Test planning and test resource optimization for droplet-based microfluidic systems. J Electron Test 22(2):199–210
22.
Zurück zum Zitat Su F, Hwang W, Mukherjee A, Chakrabarty K (2005) Defect-oriented testing and diagnosis of digital microfluidics-based biochips. In: Proc. of IEEE International Test Conference, Austin, TX, United States, pp 1–10 Su F, Hwang W, Mukherjee A, Chakrabarty K (2005) Defect-oriented testing and diagnosis of digital microfluidics-based biochips. In: Proc. of IEEE International Test Conference, Austin, TX, United States, pp 1–10
23.
Zurück zum Zitat Xu T, Chakrabarty K (2007) Parallel scan-like test and multiple-defect diagnosis for digital microfluidic biochips. IEEE T Biomed Circ S 1(2):148–158 Xu T, Chakrabarty K (2007) Parallel scan-like test and multiple-defect diagnosis for digital microfluidic biochips. IEEE T Biomed Circ S 1(2):148–158
24.
Zurück zum Zitat Subhamita M, Tuhina S (2015) Distributed scan like fault detection and test optimization for digital microfluidic biochips. J Electron Test 31(3):311–319 Subhamita M, Tuhina S (2015) Distributed scan like fault detection and test optimization for digital microfluidic biochips. J Electron Test 31(3):311–319
25.
Zurück zum Zitat Li Z, Dinh T A, Ho TY, Chakrabarty K (2014) Reliability-driven pipelined scan-like testing of digital microfluidic biochips. In: Proc. of IEEE Asian Test Symposium, Hangzhou, China, pp 57–62 Li Z, Dinh T A, Ho TY, Chakrabarty K (2014) Reliability-driven pipelined scan-like testing of digital microfluidic biochips. In: Proc. of IEEE Asian Test Symposium, Hangzhou, China, pp 57–62
26.
Zurück zum Zitat Zhao Y, Chakrabarty K (2010) Digital microfluidic logic gates and their application to built-in self-test of lab-on-chip. IEEE T Biomed Circ S 4(4):250–262 Zhao Y, Chakrabarty K (2010) Digital microfluidic logic gates and their application to built-in self-test of lab-on-chip. IEEE T Biomed Circ S 4(4):250–262
27.
Zurück zum Zitat Lai KYT, Shiu MF, Lu, YW, Ho Y, Kao YC, Yang YT, Wang G, Liu KM, Chang HC, Lee CY (2015) A field-programmable lab-on-a-chip with built-in self-test circuit and low-power sensor-fusion solution in 0.35 μm standard CMOS process. In: Proc. of IEEE Asian Solid-State Circuits Conference, Xiamen, China, pp 281–284 Lai KYT, Shiu MF, Lu, YW, Ho Y, Kao YC, Yang YT, Wang G, Liu KM, Chang HC, Lee CY (2015) A field-programmable lab-on-a-chip with built-in self-test circuit and low-power sensor-fusion solution in 0.35 μm standard CMOS process. In: Proc. of IEEE Asian Solid-State Circuits Conference, Xiamen, China, pp 281–284
28.
Zurück zum Zitat Dinh T A, Yamashita S, Ho TY, Chakrabarty K (2015) Testing of digital microfluidic biochips with arbitrary layouts. In: Proc. of IEEE European Test Symposium, Cluj-Napoca, Romania, pp 1–2 Dinh T A, Yamashita S, Ho TY, Chakrabarty K (2015) Testing of digital microfluidic biochips with arbitrary layouts. In: Proc. of IEEE European Test Symposium, Cluj-Napoca, Romania, pp 1–2
29.
Zurück zum Zitat Dinh T A, Yamashita S, Ho TY, Chakrabarty K (2015) A general testing method for digital microfluidic biochips under physical constraints. In: Proc. of International Test Conference, Anaheim, CA, USA, pp 1–8 Dinh T A, Yamashita S, Ho TY, Chakrabarty K (2015) A general testing method for digital microfluidic biochips under physical constraints. In: Proc. of International Test Conference, Anaheim, CA, USA, pp 1–8
30.
Zurück zum Zitat Zheng W, Yu H, Feng L, Fu P, Jiang H (2017) Single droplet on-line testing path optimization for digital microfluidic biochips based on the improved ant colony algorithm. In: Proc. of IEEE international instrumentation and measurement technology conference (I2MTC), Turin, Italy. https://doi.org/10.1109/I2MTC.2017.7969904 Zheng W, Yu H, Feng L, Fu P, Jiang H (2017) Single droplet on-line testing path optimization for digital microfluidic biochips based on the improved ant colony algorithm. In: Proc. of IEEE international instrumentation and measurement technology conference (I2MTC), Turin, Italy. https://​doi.​org/​10.​1109/​I2MTC.​2017.​7969904
31.
Zurück zum Zitat Xu C, Cai Z, Hu C (2014) On-line test path optimization for digital microfluidic biochips based on ant colony algorithm. Chin J Sci Instrum 35(6):1417–1424 Xu C, Cai Z, Hu C (2014) On-line test path optimization for digital microfluidic biochips based on ant colony algorithm. Chin J Sci Instrum 35(6):1417–1424
32.
Zurück zum Zitat Pan I, Dasgupta P, Rahaman H, Samanta T (2011) Ant colony optimization based droplet routing technique in digital microfluidic biochip. In: Proc. of International Symposium on Electronic System Design, Kochi, Kerala, 223–229 Pan I, Dasgupta P, Rahaman H, Samanta T (2011) Ant colony optimization based droplet routing technique in digital microfluidic biochip. In: Proc. of International Symposium on Electronic System Design, Kochi, Kerala, 223–229
33.
Zurück zum Zitat Juárez J, Brizuela CA, Martínez-Pérez IM (2018) An evolutionary multi-objective optimization algorithm for the routing of droplets in Digital Microfluidic Biochips. Inf Sci 429:130–146MathSciNet Juárez J, Brizuela CA, Martínez-Pérez IM (2018) An evolutionary multi-objective optimization algorithm for the routing of droplets in Digital Microfluidic Biochips. Inf Sci 429:130–146MathSciNet
34.
Zurück zum Zitat Bhattacharjee S, Mitra D, Bhattacharya BB (2017) Robust in-field testing of digital microfluidic biochips. ACM J Emerg Tech Com 4(1):1–17 Bhattacharjee S, Mitra D, Bhattacharya BB (2017) Robust in-field testing of digital microfluidic biochips. ACM J Emerg Tech Com 4(1):1–17
35.
Zurück zum Zitat Rezoug A, Bader-El-Den M, Boughaci D (2018) Guided genetic algorithm for the multimensional knapsack problem. Memet Comput 10(1):29–42 Rezoug A, Bader-El-Den M, Boughaci D (2018) Guided genetic algorithm for the multimensional knapsack problem. Memet Comput 10(1):29–42
Metadaten
Titel
An Efficient Algorithm for Optimizing the Test Path of Digital Microfluidic Biochips
verfasst von
Xijun Huang
Chuanpei Xu
Long Zhang
Publikationsdatum
18.03.2020
Verlag
Springer US
Erschienen in
Journal of Electronic Testing / Ausgabe 2/2020
Print ISSN: 0923-8174
Elektronische ISSN: 1573-0727
DOI
https://doi.org/10.1007/s10836-020-05865-6

Weitere Artikel der Ausgabe 2/2020

Journal of Electronic Testing 2/2020 Zur Ausgabe

Neuer Inhalt