Skip to main content
Erschienen in: International Journal of Computer Assisted Radiology and Surgery 8/2016

01.08.2016 | Original Article

An open tool for input function estimation and quantification of dynamic PET FDG brain scans

verfasst von: Martín Bertrán, Natalia Martínez, Guillermo Carbajal, Alicia Fernández, Álvaro Gómez

Erschienen in: International Journal of Computer Assisted Radiology and Surgery | Ausgabe 8/2016

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Purpose

Positron emission tomography (PET) analysis of clinical studies is mostly restricted to qualitative evaluation. Quantitative analysis of PET studies is highly desirable to be able to compute an objective measurement of the process of interest in order to evaluate treatment response and/or compare patient data. But implementation of quantitative analysis generally requires the determination of the input function: the arterial blood or plasma activity which indicates how much tracer is available for uptake in the brain. The purpose of our work was to share with the community an open software tool that can assist in the estimation of this input function, and the derivation of a quantitative map from the dynamic PET study.

Methods

Arterial blood sampling during the PET study is the gold standard method to get the input function, but is uncomfortable and risky for the patient so it is rarely used in routine studies. To overcome the lack of a direct input function, different alternatives have been devised and are available in the literature. These alternatives derive the input function from the PET image itself (image-derived input function) or from data gathered from previous similar studies (population-based input function). In this article, we present ongoing work that includes the development of a software tool that integrates several methods with novel strategies for the segmentation of blood pools and parameter estimation.

Results

The tool is available as an extension to the 3D Slicer software. Tests on phantoms were conducted in order to validate the implemented methods. We evaluated the segmentation algorithms over a range of acquisition conditions and vasculature size. Input function estimation algorithms were evaluated against ground truth of the phantoms, as well as on their impact over the final quantification map. End-to-end use of the tool yields quantification maps with \({<}5\,\%\) relative error in the estimated influx versus ground truth on phantoms.

Conclusions

The main contribution of this article is the development of an open-source, free to use tool that encapsulates several well-known methods for the estimation of the input function and the quantification of dynamic PET FDG studies. Some alternative strategies are also proposed and implemented in the tool for the segmentation of blood pools and parameter estimation. The tool was tested on phantoms with encouraging results that suggest that even bloodless estimators could provide a viable alternative to blood sampling for quantification using graphical analysis. The open tool is a promising opportunity for collaboration among investigators and further validation on real studies.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Cherry SR, Sorenson JA, Phelps ME (2012) Physics in nuclear medicine. Elsevier, Philadelphia Cherry SR, Sorenson JA, Phelps ME (2012) Physics in nuclear medicine. Elsevier, Philadelphia
2.
Zurück zum Zitat Zanotti-Fregonara P, Chen K, Liow JS, Fujita M, Innis RB (2011) Image-derived input function for brain PET studies: many challenges and few opportunities. J Cereb Blood Flow Metab 31(10):1986–1998CrossRefPubMedPubMedCentral Zanotti-Fregonara P, Chen K, Liow JS, Fujita M, Innis RB (2011) Image-derived input function for brain PET studies: many challenges and few opportunities. J Cereb Blood Flow Metab 31(10):1986–1998CrossRefPubMedPubMedCentral
3.
Zurück zum Zitat Chen K, Bandy D, Reiman E, Huang SC, Lawson M, Feng D, Yun LS, Palant A (1998) Noninvasive quantification of the cerebral metabolic rate for glucose using positron emission tomography, 18F-fluoro-2-deoxyglucose, the Patlak method, and an image-derived input function. J Cereb Blood Flow Metab 18:716–723CrossRefPubMed Chen K, Bandy D, Reiman E, Huang SC, Lawson M, Feng D, Yun LS, Palant A (1998) Noninvasive quantification of the cerebral metabolic rate for glucose using positron emission tomography, 18F-fluoro-2-deoxyglucose, the Patlak method, and an image-derived input function. J Cereb Blood Flow Metab 18:716–723CrossRefPubMed
4.
Zurück zum Zitat Su KH, Wu LC, Liu RS, Wang SJ, Chen JC (2005) Quantification method in [18F]fluorodeoxyglucose brain positron emission tomography using independent component analysis. Nucl Med Commun 26:995–1004CrossRefPubMed Su KH, Wu LC, Liu RS, Wang SJ, Chen JC (2005) Quantification method in [18F]fluorodeoxyglucose brain positron emission tomography using independent component analysis. Nucl Med Commun 26:995–1004CrossRefPubMed
5.
Zurück zum Zitat Parker BJ, Feng D (2005) Graph-based Mumford–Shah segmentation of dynamic PET with application to input function estimation. IEEE Trans Nucl Sci 52:79–89 Parker BJ, Feng D (2005) Graph-based Mumford–Shah segmentation of dynamic PET with application to input function estimation. IEEE Trans Nucl Sci 52:79–89
6.
Zurück zum Zitat Zanotti-Fregonara Maroy R, Sureau F, Comtat C, Jan S, Syrota A, Tr’bossen R (2007) Noninvasive quantification of the cerebral metabolic rate of (18)F-FDG in dynamic brain PET studies using an image-derived input function. Eur J Nucl Med Mol Imaging 34(Suppl 2):S113 Zanotti-Fregonara Maroy R, Sureau F, Comtat C, Jan S, Syrota A, Tr’bossen R (2007) Noninvasive quantification of the cerebral metabolic rate of (18)F-FDG in dynamic brain PET studies using an image-derived input function. Eur J Nucl Med Mol Imaging 34(Suppl 2):S113
7.
Zurück zum Zitat Zanotti-Fregonara P, Maroy R, Peyronneau MA, Trebossen R, Bottlaender M (2012) Minimally invasive input function for 2-\(^18\)F-fluoro-A-85380 brain PET studies. Eur J Nucl Med Mol Imaging 39(4):651–659 Zanotti-Fregonara P, Maroy R, Peyronneau MA, Trebossen R, Bottlaender M (2012) Minimally invasive input function for 2-\(^18\)F-fluoro-A-85380 brain PET studies. Eur J Nucl Med Mol Imaging 39(4):651–659
8.
Zurück zum Zitat Soret M, Bacharach SL, Buvat I (2007) Partial-volume effect in PET tumor imaging. J Nucl Med 48(6):932–945CrossRefPubMed Soret M, Bacharach SL, Buvat I (2007) Partial-volume effect in PET tumor imaging. J Nucl Med 48(6):932–945CrossRefPubMed
9.
Zurück zum Zitat Naganawa M, Kimura Y, Ishii K, Oda K, Ishiwata K, Matani A (2005) Extraction of a plasma time-activity curve from dynamic brain PET images based on independent component analysis. IEEE Trans Biomed Eng 52(2):201–210CrossRefPubMed Naganawa M, Kimura Y, Ishii K, Oda K, Ishiwata K, Matani A (2005) Extraction of a plasma time-activity curve from dynamic brain PET images based on independent component analysis. IEEE Trans Biomed Eng 52(2):201–210CrossRefPubMed
10.
Zurück zum Zitat Hunter GJ, Hamberg LM, Alpert NM, Choi NC, Fischman AJ (1996) Simplied measurement of deoxyglucose utilization rate. J Nucl Med Soc publ Soc Nucl Med 37(6):950–955 Hunter GJ, Hamberg LM, Alpert NM, Choi NC, Fischman AJ (1996) Simplied measurement of deoxyglucose utilization rate. J Nucl Med Soc publ Soc Nucl Med 37(6):950–955
11.
Zurück zum Zitat Otsu N (1979) A threshold selection method from gray-level histograms. IEEE Trans Syst Man Cybern 9(1):62–66CrossRef Otsu N (1979) A threshold selection method from gray-level histograms. IEEE Trans Syst Man Cybern 9(1):62–66CrossRef
12.
Zurück zum Zitat Zanotti-Fregonara P, Maroy R, Comtat C, Jan S, Gaura V, Bar-Hen A, Trebossen R (2009) Comparison of 3 methods of automated internal carotid segmentation in human brain PET studies: application to the estimation of arterial input function. J Nucl Med 50(3):461–467CrossRefPubMed Zanotti-Fregonara P, Maroy R, Comtat C, Jan S, Gaura V, Bar-Hen A, Trebossen R (2009) Comparison of 3 methods of automated internal carotid segmentation in human brain PET studies: application to the estimation of arterial input function. J Nucl Med 50(3):461–467CrossRefPubMed
13.
Zurück zum Zitat Huang SC, Phelps ME, Homan EJ, Sideris K, Selin CJ, Kuhl DE (1980) Noninvasive determination of local cerebral metabolic rate of glucose in man. Am J Physiol 238(1):E69–E82PubMed Huang SC, Phelps ME, Homan EJ, Sideris K, Selin CJ, Kuhl DE (1980) Noninvasive determination of local cerebral metabolic rate of glucose in man. Am J Physiol 238(1):E69–E82PubMed
15.
Zurück zum Zitat Thielemans Kris, Tsoumpas Charalampos, Mustafovic Sanida, Beisel Tobias, Aguiar Pablo, Dikaios Nikolaos, Jacobson Matthew W (2012) STIR: software for tomographic image reconstruction release 2. Phys Med Biol 57(4):867–883CrossRefPubMed Thielemans Kris, Tsoumpas Charalampos, Mustafovic Sanida, Beisel Tobias, Aguiar Pablo, Dikaios Nikolaos, Jacobson Matthew W (2012) STIR: software for tomographic image reconstruction release 2. Phys Med Biol 57(4):867–883CrossRefPubMed
Metadaten
Titel
An open tool for input function estimation and quantification of dynamic PET FDG brain scans
verfasst von
Martín Bertrán
Natalia Martínez
Guillermo Carbajal
Alicia Fernández
Álvaro Gómez
Publikationsdatum
01.08.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
International Journal of Computer Assisted Radiology and Surgery / Ausgabe 8/2016
Print ISSN: 1861-6410
Elektronische ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-015-1307-x

Weitere Artikel der Ausgabe 8/2016

International Journal of Computer Assisted Radiology and Surgery 8/2016 Zur Ausgabe