Skip to main content

2017 | OriginalPaper | Buchkapitel

Analysis of the Blood Flow Through the Centrifugal Pump

verfasst von : Joanna Mikołajczak, Jakub Słowiński, Maciej Zawiślak

Erschienen in: Proceedings of the 13th International Scientific Conference

Verlag: Springer International Publishing

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Blood flow simulation was conducted for the peripheral centrifugal pump of the artificial heart by use of numerical methods. Flow parameters were examined for the destruction of blood morphological elements, the results were compared with literature data. The learned lessons led to changes of the pump geometry, then further simulations for different constructional variants were carried out. The results of calculations led to choosing the best structural solution for heart pump and follow-on conclusions on what kind of changes may improve the flow parameters and reduce the risk of destruction of blood elements.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Behbahani M, Behr M, A Review of Computational Fluid Dynamics Analysis of Blood Pumps, European Journal of Applied Mathematics 20 (2009) 363–397. Behbahani M, Behr M, A Review of Computational Fluid Dynamics Analysis of Blood Pumps, European Journal of Applied Mathematics 20 (2009) 363–397.
2.
Zurück zum Zitat Alkhamis T.M, Beissinger R.L, Chediak J.R, Artifical surface effect on red blood cells and platelets in laminar shear flow, Blood Vol. 75/ 7, 1990. Alkhamis T.M, Beissinger R.L, Chediak J.R, Artifical surface effect on red blood cells and platelets in laminar shear flow, Blood Vol. 75/ 7, 1990.
3.
Zurück zum Zitat Caro, C. G., Pedley, T. J., Schroter, R. C. i Seed, W. A., The Mechanics of the Circulation. Cambridge: Cambridge University, 2012. Caro, C. G., Pedley, T. J., Schroter, R. C. i Seed, W. A., The Mechanics of the Circulation. Cambridge: Cambridge University, 2012.
4.
Zurück zum Zitat Leverett L.B, Hellums J.D, Alfrey C.P, Lynchred E.C, Blood cells damage by shear stress, Biophysical Journal, Vol. 12, 1972. Leverett L.B, Hellums J.D, Alfrey C.P, Lynchred E.C, Blood cells damage by shear stress, Biophysical Journal, Vol. 12, 1972.
5.
Zurück zum Zitat Taskin M.E, Fraser K.H, Zhang t, Evaluation of Eulerian and Lagrangian Models for Hemolysis Estimation, Biomedical Engineering, 2012. Taskin M.E, Fraser K.H, Zhang t, Evaluation of Eulerian and Lagrangian Models for Hemolysis Estimation, Biomedical Engineering, 2012.
6.
Zurück zum Zitat Fraser K.H, Taskin M.E, Zhang T, The effect of impeller position on CFD calculations of blood flow in magnetically levitated centrifugal blood pumps, Proceedings of the ASME 2010 Summer Bioengineering Conference (SBC2010), June 16–19, Grande Beach Resort, Naples Florida, USA. Fraser K.H, Taskin M.E, Zhang T, The effect of impeller position on CFD calculations of blood flow in magnetically levitated centrifugal blood pumps, Proceedings of the ASME 2010 Summer Bioengineering Conference (SBC2010), June 16–19, Grande Beach Resort, Naples Florida, USA.
7.
Zurück zum Zitat Jingchun W, Antaki J, Wagner W.R. Elimination of adverse leakage flow in a miniature pediatric centrifugal blood pump by computational fluid dynamics—based design optimization, ASAIO Journal, 2005. Jingchun W, Antaki J, Wagner W.R. Elimination of adverse leakage flow in a miniature pediatric centrifugal blood pump by computational fluid dynamics—based design optimization, ASAIO Journal, 2005.
8.
Zurück zum Zitat Rodefeld M., Brandon C, Cavopulmonary assist for the univentricular Fontan circulation, Thorac Cardiovasc Surg. 140/3, 2010. Rodefeld M., Brandon C, Cavopulmonary assist for the univentricular Fontan circulation, Thorac Cardiovasc Surg. 140/3, 2010.
Metadaten
Titel
Analysis of the Blood Flow Through the Centrifugal Pump
verfasst von
Joanna Mikołajczak
Jakub Słowiński
Maciej Zawiślak
Copyright-Jahr
2017
DOI
https://doi.org/10.1007/978-3-319-50938-9_38

    Marktübersichten

    Die im Laufe eines Jahres in der „adhäsion“ veröffentlichten Marktübersichten helfen Anwendern verschiedenster Branchen, sich einen gezielten Überblick über Lieferantenangebote zu verschaffen.