Abstract

The central venous access procedure is used for placing a catheter for venous interventions, defibrillator devices or even filters when required. The access depends on patient-related factors that may increase the procedure’s difficulty. However, when performing the procedure on newborns, the level of difficulty rises considerably and any mistake may cause damages on tissues, lungs or the accessed vein, those can affect the medical condition of the patient. This work focus on the development of an augmented reality application for training pediatricians in the central venous access in newborns while allowing handling surgical tools. The system has a 3D marker tracking, that enables the user interact with models of surgical tools such as syringe, blunt guidewire, dilating device and catheter, each one of them shows up over the marker. The prototype is programmed in Unity3D with the use of AR Vuforia library and an Oculus VR with an attached webcam. The system makes a suitable tracking of the surgical instruments within a controlled lighting. To conclude, finished and suitable prototype will be tested with the help of medical students to validate their impact as simulator training in this technique.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Walser, E.M.: Venous access ports: indications, implantation technique, follow-up, and complications. Cardiovasc. Intervent. Radiol. 35, 751–764 (2012)CrossRef Walser, E.M.: Venous access ports: indications, implantation technique, follow-up, and complications. Cardiovasc. Intervent. Radiol. 35, 751–764 (2012)CrossRef
3.
Zurück zum Zitat Okuda, Y., Bryson, E.O., DeMaria, S., Jacobson, L., Quinones, J., Shen, B., Levine, A.I.: The utility of simulation in medical education: what is the evidence? Mt. Sinai J. Med.: J. Transl. Personalized Med. 76(4), 330–343 (2009)CrossRef Okuda, Y., Bryson, E.O., DeMaria, S., Jacobson, L., Quinones, J., Shen, B., Levine, A.I.: The utility of simulation in medical education: what is the evidence? Mt. Sinai J. Med.: J. Transl. Personalized Med. 76(4), 330–343 (2009)CrossRef
4.
Zurück zum Zitat Feygin, D., Ho, C.H.: U.S. Patent No. 8,784,111 (2014) Feygin, D., Ho, C.H.: U.S. Patent No. 8,784,111 (2014)
5.
Zurück zum Zitat Amesur, N.B., Wang, D.C., Chang, W., Weiser, D., Klatzky, R., Shukla, G., Stetten, G.D.: Peripherally inserted central catheter placement using the sonic flashlight. J. Vasc. Interv. Radiol. 20(10), 1380–1383 (2009)CrossRef Amesur, N.B., Wang, D.C., Chang, W., Weiser, D., Klatzky, R., Shukla, G., Stetten, G.D.: Peripherally inserted central catheter placement using the sonic flashlight. J. Vasc. Interv. Radiol. 20(10), 1380–1383 (2009)CrossRef
6.
Zurück zum Zitat Larnpotang, S., Lizdas, D., Rajon, D., Luria, I., Gravenstein, N., Bisht, Y., Robinson, A.: Mixed simulators: augmented physical simulators with virtual underlays. In: IEEE Virtual Reality (VR), pp. 7–10. IEEE Press, Orlando (2013) Larnpotang, S., Lizdas, D., Rajon, D., Luria, I., Gravenstein, N., Bisht, Y., Robinson, A.: Mixed simulators: augmented physical simulators with virtual underlays. In: IEEE Virtual Reality (VR), pp. 7–10. IEEE Press, Orlando (2013)
10.
Zurück zum Zitat Barbé, L., Bayle, B., De Mathelin, M., Gangi, A.: Needle insertions modeling: identifiability and limitations. Biomed. Signal Process. Control 2(3), 191–198 (2007)CrossRef Barbé, L., Bayle, B., De Mathelin, M., Gangi, A.: Needle insertions modeling: identifiability and limitations. Biomed. Signal Process. Control 2(3), 191–198 (2007)CrossRef
Metadaten
Titel
Augmented Reality Central Venous Access Training Simulator
verfasst von
Erika Gutierrez-Puerto
Lizeth Vega-Medina
Gerardo Tibamoso
Alvaro Uribe-Quevedo
Byron Perez-Gutierrez
Copyright-Jahr
2015
Verlag
Springer International Publishing
DOI
https://doi.org/10.1007/978-3-319-21380-4_31

Neuer Inhalt