Abstract

Transpyloric tube insertion is a commonly intervention which consists in inserting a tube through the nose, the oesophagus and the stomach until the pylorus. This procedure can be done blindly if no licensed physician operator is available. Thus, the caregivers have to insert the tube without any visual feedbacks. The position of the tube has also to be conformed to avoid any issues.
We proposed a guidance system for the insertion of this tube through an augmented reality application using an electromagnetic tracker. The trajectory and the orientation of the tube were visualized on a screen to monitor the tube insertion but also to conform the position of the tube tip inside the pylorus. This monitoring was improved by adding preoperative landmarks coming from a CT image or intraoperative landmarks obtained with ultrasound. Finally, the display was overlaid on a camera view to match the tube trajectory on the patient during the insertion so the clinicians directly visualized anatomical landmarks to guide themselves during the tube insertion.
Preliminary results on one phantom showed the usefulness of our guidance system for blindly tube insertion. Further evaluations have to be realized on animals and on patients to validate these results.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Akers, A.S., Pinsky, M.: Placement of a magnetic small bowel feeding tube at the bedside the syncro-bluetube. J. Parenter. Enteral Nutr. 0148607115594235 (2015) Akers, A.S., Pinsky, M.: Placement of a magnetic small bowel feeding tube at the bedside the syncro-bluetube. J. Parenter. Enteral Nutr. 0148607115594235 (2015)
2.
Zurück zum Zitat Boivin, M., Levy, H., Hayes, J., Magnet-Guided Enteral Feeding Tube Study Group, et al.: A multicenter, prospective study of the placement of transpyloric feeding tubes with assistance of a magnetic device. J. Parenter. Enteral Nutr. 24(5) 304–307 (2000) Boivin, M., Levy, H., Hayes, J., Magnet-Guided Enteral Feeding Tube Study Group, et al.: A multicenter, prospective study of the placement of transpyloric feeding tubes with assistance of a magnetic device. J. Parenter. Enteral Nutr. 24(5) 304–307 (2000)
3.
Zurück zum Zitat Boyer, N., McCarthy, M.S., Mount, C.A.: Analysis of an electromagnetic tube placement device versus a self-advancing nasal jejunal device for postpyloric feeding tube placement. J. Hosp. Med. 9(1), 23–28 (2014)CrossRef Boyer, N., McCarthy, M.S., Mount, C.A.: Analysis of an electromagnetic tube placement device versus a self-advancing nasal jejunal device for postpyloric feeding tube placement. J. Hosp. Med. 9(1), 23–28 (2014)CrossRef
4.
Zurück zum Zitat Cohen, M.D., Ellett, M.L.C., Perkins, S.M., Lane, K.A.: Accurate localization of the position of the tip of a naso/orogastric tube in children; where is the location of the gastro-esophageal junction? Pediatr. Radiol. 41(10), 1266–1271 (2011)CrossRef Cohen, M.D., Ellett, M.L.C., Perkins, S.M., Lane, K.A.: Accurate localization of the position of the tip of a naso/orogastric tube in children; where is the location of the gastro-esophageal junction? Pediatr. Radiol. 41(10), 1266–1271 (2011)CrossRef
5.
Zurück zum Zitat Deane, A.M., Fraser, R.J., Young, R.J., Foreman, B., O’Conner, S.N., Chapman, M.J., et al.: Evaluation of a bedside technique for post-pyloric placement of feeding catheters. Crit. Care Resusc. 11(3), 180 (2009) Deane, A.M., Fraser, R.J., Young, R.J., Foreman, B., O’Conner, S.N., Chapman, M.J., et al.: Evaluation of a bedside technique for post-pyloric placement of feeding catheters. Crit. Care Resusc. 11(3), 180 (2009)
6.
Zurück zum Zitat Dolan, A.M., O’Hanlon, C., O’Rourke, J.: An evaluation of the cortrak enteral access system in our intensive care. Ir. Med. J. (2012) Dolan, A.M., O’Hanlon, C., O’Rourke, J.: An evaluation of the cortrak enteral access system in our intensive care. Ir. Med. J. (2012)
7.
Zurück zum Zitat Gabriel, S.A., Ackermann, R.J.: Placement of nasoenteral feeding tubes using external magnetic guidance. J. Parenter. Enteral Nutr. 28(2), 119–122 (2004)CrossRef Gabriel, S.A., Ackermann, R.J.: Placement of nasoenteral feeding tubes using external magnetic guidance. J. Parenter. Enteral Nutr. 28(2), 119–122 (2004)CrossRef
8.
Zurück zum Zitat Gubler, C., Bauerfeind, P., Vavricka, S.R., Mullhaupt, B., Fried, M., Wildi, S.M.: Bedside sonographic control for positioning enteral feeding tubes: a controlled study in intensive care unit patients. Endoscopy 38(12), 1256–1260 (2006)CrossRef Gubler, C., Bauerfeind, P., Vavricka, S.R., Mullhaupt, B., Fried, M., Wildi, S.M.: Bedside sonographic control for positioning enteral feeding tubes: a controlled study in intensive care unit patients. Endoscopy 38(12), 1256–1260 (2006)CrossRef
9.
Zurück zum Zitat Hernandez-Socorro, C.R., Marin, J., Ruiz-Santana, S., Santana, L., Manzano, J.L.: Bedside sonographic-guided versus blind nasoenteric feeding tube placement in critically ill patients. Crit. Care Med. 24(10), 1690–1694 (1996)CrossRef Hernandez-Socorro, C.R., Marin, J., Ruiz-Santana, S., Santana, L., Manzano, J.L.: Bedside sonographic-guided versus blind nasoenteric feeding tube placement in critically ill patients. Crit. Care Med. 24(10), 1690–1694 (1996)CrossRef
10.
Zurück zum Zitat Kim, H.M., So, B.H., Park, K.N., Choi, S.M., Jeong, W.J.: The effectiveness of ultrasonography in verifying the placement of a nasogastric tube in patients with low consciousness at an emergency center. J. Emerg. Med. 43(5), 918 (2012)CrossRef Kim, H.M., So, B.H., Park, K.N., Choi, S.M., Jeong, W.J.: The effectiveness of ultrasonography in verifying the placement of a nasogastric tube in patients with low consciousness at an emergency center. J. Emerg. Med. 43(5), 918 (2012)CrossRef
11.
Zurück zum Zitat Kline, A.M., Sorce, L., Sullivan, C., Weishaar, J., Steinhorn, D.M.: Use of a noninvasive electromagnetic device to place transpyloric feeding tubes in critically ill children. Am. J. Crit. Care 20(6), 453–460 (2011)CrossRef Kline, A.M., Sorce, L., Sullivan, C., Weishaar, J., Steinhorn, D.M.: Use of a noninvasive electromagnetic device to place transpyloric feeding tubes in critically ill children. Am. J. Crit. Care 20(6), 453–460 (2011)CrossRef
12.
Zurück zum Zitat Koopmann, M.C., Kudsk, K.A., Szotkowski, M.J., Rees, S.M.: A team-based protocol and electromagnetic technology eliminate feeding tube placement complications. Ann. Surg. 253(2), 297–302 (2011)CrossRef Koopmann, M.C., Kudsk, K.A., Szotkowski, M.J., Rees, S.M.: A team-based protocol and electromagnetic technology eliminate feeding tube placement complications. Ann. Surg. 253(2), 297–302 (2011)CrossRef
13.
Zurück zum Zitat Mathus-Vliegen, E.M.H., Duflou, A., Spanier, M.B.W., Fockens, P.: Nasoenteral feeding tube placement by nurses using an electromagnetic guidance system (with video). Gastrointest. Endosc. 71(4), 728–736 (2010)CrossRef Mathus-Vliegen, E.M.H., Duflou, A., Spanier, M.B.W., Fockens, P.: Nasoenteral feeding tube placement by nurses using an electromagnetic guidance system (with video). Gastrointest. Endosc. 71(4), 728–736 (2010)CrossRef
14.
Zurück zum Zitat Metheny, N.A., Meert, K.L.: Effectiveness of an electromagnetic feeding tube placement device in detecting inadvertent respiratory placement. Am. J. Crit. Care 23(3), 240–248 (2014)CrossRef Metheny, N.A., Meert, K.L.: Effectiveness of an electromagnetic feeding tube placement device in detecting inadvertent respiratory placement. Am. J. Crit. Care 23(3), 240–248 (2014)CrossRef
15.
Zurück zum Zitat Metheny, N.A., Meert, K.L.: A review of published case reports of inadvertent pulmonary placement of nasogastric tubes in children. J. Pediatr. Nurs. 29(1), e7–e12 (2014)CrossRef Metheny, N.A., Meert, K.L.: A review of published case reports of inadvertent pulmonary placement of nasogastric tubes in children. J. Pediatr. Nurs. 29(1), e7–e12 (2014)CrossRef
16.
Zurück zum Zitat Milsom, S.A., Sweeting, J.A., Sheahan, H., Haemmerle, E., Windsor, J.A.: Naso-enteric tube placement: a review of methods to confirm tip location, global applicability and requirements. World J. Surg. 39(9), 2243–2252 (2015)CrossRef Milsom, S.A., Sweeting, J.A., Sheahan, H., Haemmerle, E., Windsor, J.A.: Naso-enteric tube placement: a review of methods to confirm tip location, global applicability and requirements. World J. Surg. 39(9), 2243–2252 (2015)CrossRef
17.
Zurück zum Zitat Nicolau, S., Soler, L., Mutter, D., Marescaux, J.: Augmented reality in laparoscopic surgical oncology. Surg. Oncol. 20(3), 189–201 (2011)CrossRef Nicolau, S., Soler, L., Mutter, D., Marescaux, J.: Augmented reality in laparoscopic surgical oncology. Surg. Oncol. 20(3), 189–201 (2011)CrossRef
18.
Zurück zum Zitat Ozdemir, B., Frost, M., Hayes, J., Sullivan, D.H.: Placement of nasoenteral feeding tubes using magnetic guidance: retesting a new technique. J. Am. Coll. Nutr. 19(4), 446–451 (2000)CrossRef Ozdemir, B., Frost, M., Hayes, J., Sullivan, D.H.: Placement of nasoenteral feeding tubes using magnetic guidance: retesting a new technique. J. Am. Coll. Nutr. 19(4), 446–451 (2000)CrossRef
19.
Zurück zum Zitat Powers, J., Luebbehusen, M., Spitzer, T., Coddington, A., Beeson, T., Brown, J., Jones, D.: Verification of an electromagnetic placement device compared with abdominal radiograph to predict accuracy of feeding tube placement. J. Parenter. Enteral Nutr. 35(4), 535–539 (2011)CrossRef Powers, J., Luebbehusen, M., Spitzer, T., Coddington, A., Beeson, T., Brown, J., Jones, D.: Verification of an electromagnetic placement device compared with abdominal radiograph to predict accuracy of feeding tube placement. J. Parenter. Enteral Nutr. 35(4), 535–539 (2011)CrossRef
20.
Zurück zum Zitat Smithard, D., Barrett, N.A., Hargroves, D., Elliot, S.: Electromagnetic sensor-guided enteral access systems: a literature review. Dysphagia 30(3), 275–285 (2015)CrossRef Smithard, D., Barrett, N.A., Hargroves, D., Elliot, S.: Electromagnetic sensor-guided enteral access systems: a literature review. Dysphagia 30(3), 275–285 (2015)CrossRef
21.
Zurück zum Zitat Volonté, F., Pugin, F., Bucher, P., Sugimoto, M., Ratib, O., Morel, P.: Augmented reality and image overlay navigation with Osirix in laparoscopic and robotic surgery: not only a matter of fashion. J. Hepato-Biliary-Pancreat. Sci. 18(4), 506–509 (2011)CrossRef Volonté, F., Pugin, F., Bucher, P., Sugimoto, M., Ratib, O., Morel, P.: Augmented reality and image overlay navigation with Osirix in laparoscopic and robotic surgery: not only a matter of fashion. J. Hepato-Biliary-Pancreat. Sci. 18(4), 506–509 (2011)CrossRef
22.
Zurück zum Zitat Windle, E.M., Beddow, D., Hall, E., Wright, J., Sundar, N.: Implementation of an electromagnetic imaging system to facilitate nasogastric and post-pyloric feeding tube placement in patients with and without critical illness. J. Hum. Nutr. Diet. 23(1), 61–68 (2010)CrossRef Windle, E.M., Beddow, D., Hall, E., Wright, J., Sundar, N.: Implementation of an electromagnetic imaging system to facilitate nasogastric and post-pyloric feeding tube placement in patients with and without critical illness. J. Hum. Nutr. Diet. 23(1), 61–68 (2010)CrossRef
Metadaten
Titel
Augmented Reality Guidance with Electromagnetic Tracking for Transpyloric Tube Insertion
verfasst von
Jordan Bano
Tomohiko Akahoshi
Ryu Nakadate
Byunghyun Cho
Makoto Hashizume
Copyright-Jahr
2016
DOI
https://doi.org/10.1007/978-3-319-43775-0_18