Abstract

Purpose

A realistic guidewire behavior simulation is a vital component of a virtual vascular intervention system. Such systems are a safe, low-cost means of establishing a training environment to help inexperienced surgeons develop their intervention skills. Previous attempts to simulate the complex movement of a guidewire inside blood vessels have rarely considered the influence of blood flow. In this paper, we address this problem by integrating blood flow analysis and propose a novel guidewire simulation model.

Methods

The blood flow distribution inside the arterial vasculature was computed by separating the vascular model into discrete cylindrical vessels and modeling the flow in each vessel according to Poiseuille Law. The blood flow computation was then integrated into a robust Kirchhoff elastic model. With hardware acceleration, the guidewire simulation can be run in real time. To evaluate the simulation, an experimental environment with a 3D-printed vascular phantom and an electromagnetic tracking system was set up, with clinically used guidewire sensors applied to trace its motion as the standard for comparison.

Results

The virtual guidewire motion trace was assessed by comparing it to the comparison standard. The root-mean-square (RMS) value of the newly proposed guidewire model was 2.14 mm ± 1.24 mm, lower than the value of 4.81 mm ± 3.80 mm for the previous Kirchhoff model, while maintaining a computation speed of at least 30 fps.

Conclusion

The experimental results revealed that the blood flow-induced model exhibits better performance and physical credibility with a lower and more stable RMS error than the previous Kirchhoff model.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
2.
Zurück zum Zitat Fu Y, Liu H, Huang W, Wang S, Liang Z (2009) Steerable catheters in minimally invasive vascular surgery. Int J Med Robot Comput Assist Surg 5:381–391. doi:10.1002/rcs.282 CrossRef Fu Y, Liu H, Huang W, Wang S, Liang Z (2009) Steerable catheters in minimally invasive vascular surgery. Int J Med Robot Comput Assist Surg 5:381–391. doi:10.​1002/​rcs.​282 CrossRef
5.
Zurück zum Zitat Ahmed K, Keeling AN, Fakhry M, Ashrafian H, Aggarwal R, Naughton PA, Darzi A, Cheshire N, Athanasiou T, Hamady M (2010) Role of virtual reality simulation in teaching and assessing technical skills in endovascular intervention. J Vasc Interv Radiol 21:55–66. doi:10.1016/j.jvir.2009.09.019 CrossRefPubMed Ahmed K, Keeling AN, Fakhry M, Ashrafian H, Aggarwal R, Naughton PA, Darzi A, Cheshire N, Athanasiou T, Hamady M (2010) Role of virtual reality simulation in teaching and assessing technical skills in endovascular intervention. J Vasc Interv Radiol 21:55–66. doi:10.​1016/​j.​jvir.​2009.​09.​019 CrossRefPubMed
7.
Zurück zum Zitat Lenoir J, Meseure P, Grisoni L, Chaillou C (2003) Surgical thread simulation. ESAIM Proc 12:102–107CrossRef Lenoir J, Meseure P, Grisoni L, Chaillou C (2003) Surgical thread simulation. ESAIM Proc 12:102–107CrossRef
8.
Zurück zum Zitat Cotin S, Duriez C, Lenoir J, Neumann P, Dawson S (2005) New approaches to catheter navigation for interventional radiology simulation. Med Image Comput Comput Assist Interv 11:534–542 Cotin S, Duriez C, Lenoir J, Neumann P, Dawson S (2005) New approaches to catheter navigation for interventional radiology simulation. Med Image Comput Comput Assist Interv 11:534–542
10.
Zurück zum Zitat Dequidt J, Marchal M, Duriez C, Kerien E, Cotin S (2008) Interactive simulation of embolization coils: modeling and experimental validation. In: Lecture notes computer science (including subseries lecture notes artificial intelligence lecture notes in bioinformatics), vol 5241 LNCS, pp 695–702. doi:10.1007/978-3-540-85988-8_83 Dequidt J, Marchal M, Duriez C, Kerien E, Cotin S (2008) Interactive simulation of embolization coils: modeling and experimental validation. In: Lecture notes computer science (including subseries lecture notes artificial intelligence lecture notes in bioinformatics), vol 5241 LNCS, pp 695–702. doi:10.​1007/​978-3-540-85988-8_​83
12.
Zurück zum Zitat Spillmann J, Teschner M (2007) CORDE: Cosserat Rod Elements for the Dynamic Simulation of One-Dimensional Elastic Objects. Eurographics/ACM SIGGRAPH Symp Comput Animat 1:63–72. doi:10.2312/SCA/SCA07/063-072 Spillmann J, Teschner M (2007) CORDE: Cosserat Rod Elements for the Dynamic Simulation of One-Dimensional Elastic Objects. Eurographics/ACM SIGGRAPH Symp Comput Animat 1:63–72. doi:10.​2312/​SCA/​SCA07/​063-072
13.
Zurück zum Zitat Duratti L, Wang F, Samur E, Bleuler H (2008) A real-time simulator for interventional radiology. In: Proceedings of the 2008 ACM symposium on virtual reality software and technology—VRST ’08, p 105. doi:10.1145/1450579.1450602 Duratti L, Wang F, Samur E, Bleuler H (2008) A real-time simulator for interventional radiology. In: Proceedings of the 2008 ACM symposium on virtual reality software and technology—VRST ’08, p 105. doi:10.​1145/​1450579.​1450602
14.
Zurück zum Zitat Basdogan C, Ho CH, Srinivasan MA (2001) Virtual environments for medical training: graphical and haptic simulation of laparoscopic common bile duct exploration. IEEE/ASME Trans Mechatron 6:269–285. doi:10.1109/3516.951365 CrossRef Basdogan C, Ho CH, Srinivasan MA (2001) Virtual environments for medical training: graphical and haptic simulation of laparoscopic common bile duct exploration. IEEE/ASME Trans Mechatron 6:269–285. doi:10.​1109/​3516.​951365 CrossRef
16.
Zurück zum Zitat Tang W, Wan TR, Gould DA, How T, John NW (2012) A stable and real-time nonlinear elastic approach to simulating guidewire and catheter insertions based on cosserat rod. IEEE Trans Biomed Eng 59:2211–2218. doi:10.1109/TBME.2012.2199319 CrossRef Tang W, Wan TR, Gould DA, How T, John NW (2012) A stable and real-time nonlinear elastic approach to simulating guidewire and catheter insertions based on cosserat rod. IEEE Trans Biomed Eng 59:2211–2218. doi:10.​1109/​TBME.​2012.​2199319 CrossRef
18.
Zurück zum Zitat Tang W, Lagadec P, Gould D, Wan TR, Zhai J, How T (2010) A realistic elastic rod model for real-time simulation of minimally invasive vascular interventions. Vis Comput 26:1157–1165. doi:10.1007/s00371-010-0442-1 CrossRef Tang W, Lagadec P, Gould D, Wan TR, Zhai J, How T (2010) A realistic elastic rod model for real-time simulation of minimally invasive vascular interventions. Vis Comput 26:1157–1165. doi:10.​1007/​s00371-010-0442-1 CrossRef
20.
Zurück zum Zitat Almeder C (1999) Hydrodynamic modelling and simulation of the human arterial blood flow. PhD thesis, Vienna University of Technology Almeder C (1999) Hydrodynamic modelling and simulation of the human arterial blood flow. PhD thesis, Vienna University of Technology
21.
Zurück zum Zitat Wu X, Allard J, Cotin S (2007) Real-time modeling of vascular flow for angiography simulation. Med Image Comput Comput Assist Interv 10:557–565PubMed Wu X, Allard J, Cotin S (2007) Real-time modeling of vascular flow for angiography simulation. Med Image Comput Comput Assist Interv 10:557–565PubMed
22.
Zurück zum Zitat Zhu B, Iwata M, Haraguchi R, Ashihara T, Umetani N, Igarashi T, Nakazawa K (2011) Sketch-based dynamic illustration of fluid systems. ACM Trans Graph 30:1CrossRef Zhu B, Iwata M, Haraguchi R, Ashihara T, Umetani N, Igarashi T, Nakazawa K (2011) Sketch-based dynamic illustration of fluid systems. ACM Trans Graph 30:1CrossRef
24.
Zurück zum Zitat Pop SR, Hughes CJ, Ap Cenydd L, John NW (2013) A directed particle system for optimised visualization of blood flow in complex networks. Stud Health Technol Inform 184:330–336PubMed Pop SR, Hughes CJ, Ap Cenydd L, John NW (2013) A directed particle system for optimised visualization of blood flow in complex networks. Stud Health Technol Inform 184:330–336PubMed
25.
Zurück zum Zitat Antiga L (2002) Patient-specific modeling of geometry and blood flow in large arteries. Politecnico di Milano Antiga L (2002) Patient-specific modeling of geometry and blood flow in large arteries. Politecnico di Milano
Metadaten
Titel
Blood flow-induced physically based guidewire simulation for vascular intervention training
verfasst von
Jiayin Cai
Hongzhi Xie
Shuyang Zhang
Lixu Gu
Publikationsdatum
09.04.2017
Verlag
Springer International Publishing
Erschienen in
International Journal of Computer Assisted Radiology and Surgery / Ausgabe 9/2017
Print ISSN: 1861-6410
Elektronische ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-017-1583-8

Weitere Artikel der Ausgabe 9/2017

International Journal of Computer Assisted Radiology and Surgery 9/2017 Zur Ausgabe