Abstract

This paper describes a development of a curvature sensor using a solid polymer electrolyte (SPE) film. The SPE film has good flexibility, and can be used in air. In previous research, we clarified output response to deformation of the SPE sensor and the relationship between sensor output and sensor curvature. In this paper, output characteristics of the SPE sensor are investigated in detail. Four sensors with different length and width are prepared. And the influence of the SPE sensor on the sensor element shape is investigated. As a result, it is confirmed that there are a several sensors which cause a slight reduction of the sensor output because it is difficult to place the whole sensor element on the sample curve exactly. Concerning with the large sensor, it was confirmed that the reduction of the sensor output is not occurred.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
Zurück zum Zitat Bonomo C, Brunetto P, Fortuna L, Giannone P, Graziani S (2008) A tactile Sensor for biomedical applications based on IPMCs. IEEE Sens J 8(8):1486–1493CrossRef Bonomo C, Brunetto P, Fortuna L, Giannone P, Graziani S (2008) A tactile Sensor for biomedical applications based on IPMCs. IEEE Sens J 8(8):1486–1493CrossRef
Zurück zum Zitat Cho SM, Seo JH, Nam DJ (2007) An electroactive conducting polymer actuator based on NBR/RTIL solid polymer electrolyte. Smart Mater Struct 16:237–242CrossRef Cho SM, Seo JH, Nam DJ (2007) An electroactive conducting polymer actuator based on NBR/RTIL solid polymer electrolyte. Smart Mater Struct 16:237–242CrossRef
Zurück zum Zitat Konyo M, Tadokoro S, Takamori T (2000) Artificial tactile feel display using soft gel actuators. Proceedings of 2000 IEEE international conference on robotics and automation, pp 3416–3421 Konyo M, Tadokoro S, Takamori T (2000) Artificial tactile feel display using soft gel actuators. Proceedings of 2000 IEEE international conference on robotics and automation, pp 3416–3421
Zurück zum Zitat Okuyama T, Otsuki M, Komiya R, Sugoh N, Tanaka M (2009) Development of a curvature sensor using a solid polymer electrolyte. Proceedings of the 2009 JSME-IIP/ASME-ISPS joint conference on micromechatronics for information and precision equipment, No. 09-204, pp 315–316 Okuyama T, Otsuki M, Komiya R, Sugoh N, Tanaka M (2009) Development of a curvature sensor using a solid polymer electrolyte. Proceedings of the 2009 JSME-IIP/ASME-ISPS joint conference on micromechatronics for information and precision equipment, No. 09-204, pp 315–316
Zurück zum Zitat Otsuki M, Okuyama T, Tanaka M (2009) Characterization of a curvature sensor using a solid polymer electrolyte. Proceedings of SPIE’s international conference on mechatronics and information technology, vol 7500-0L Otsuki M, Okuyama T, Tanaka M (2009) Characterization of a curvature sensor using a solid polymer electrolyte. Proceedings of SPIE’s international conference on mechatronics and information technology, vol 7500-0L
Zurück zum Zitat Saito S, Katoh Y, Kokubo H, Watanabe M, Mruo S (2009) Development of a soft actuator using a photocurable ion gel. J Micromech Microeng 19:035005 Saito S, Katoh Y, Kokubo H, Watanabe M, Mruo S (2009) Development of a soft actuator using a photocurable ion gel. J Micromech Microeng 19:035005
Zurück zum Zitat Shahinpoor M (1998) Ionic polymer-metal composites (IPMC) As biomimetic sensors and actuators. Proceedings of SPIE’s 5th annual international symposium on smart structures and materials, No. 3324-27, pp 1–17 Shahinpoor M (1998) Ionic polymer-metal composites (IPMC) As biomimetic sensors and actuators. Proceedings of SPIE’s 5th annual international symposium on smart structures and materials, No. 3324-27, pp 1–17
Metadaten
Titel
Characteristic evaluation of a solid polymer electrolyte sensor
verfasst von
Manabu Otsuki
Takeshi Okuyama
Mami Tanaka
Publikationsdatum
01.06.2011
Verlag
Springer-Verlag
Erschienen in
Microsystem Technologies / Ausgabe 5-7/2011
Print ISSN: 0946-7076
Elektronische ISSN: 1432-1858
DOI
https://doi.org/10.1007/s00542-011-1285-z

Weitere Artikel der Ausgabe 5-7/2011

Microsystem Technologies 5-7/2011 Zur Ausgabe

Neuer Inhalt