Abstract

Purpose

   The purpose of this study was to evaluate clinical, functional, and radiographic outcomes following total knee arthroplasty (TKA) performed with patient-specific instrumentation (PSI), computer-assisted surgery (CAS), and manual instruments at short-term follow-up.

Methods

   122 TKAs were performed by a single surgeon: 42 with PSI, 38 with CAS, and 40 with manual instrumentation. Preoperative, 1-month, and 6-month clinical and functional outcomes were measured using the Knee Society scoring system (knee score, function score, range of motion, and pain score). Improvements in clinical and functional outcomes from the preoperative to postoperative period were analyzed. Preoperative and postoperative radiographs were measured to evaluate limb and component alignment.

Results

   Preoperative, 1-month postoperative, and 6-month postoperative knee scores, function scores, range of motion, and pain scores were highest in the PSI group compared to CAS and manual instrumentation. At 6-month follow-up, PSI TKA was associated with a statistically significant improvement in functional score when compared to manual TKA. Otherwise, there were no statistically significant differences in improvements among PSI, CAS, and manual TKA groups.

Conclusion

   The higher preoperative scores in the PSI group limits the ability to draw definitive conclusions from the raw postoperative scores, but analyzing the changes in scores revealed that PSI was associated with a statistically significant improvement in Knee Society Functional score at 6-month post-TKA as compared to CAS or manual TKA. This may be attributable to improvements in component rotation and positioning, improved component size accuracy, or other factors that are not discernible on plain radiograph.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Hafez MA, Chelule KL, Seedhom BB, Sherman KP (2006) Computer-assisted total knee arthroplasty using patient-specific templating. Clin Orthop Relat Res 444:184PubMedCrossRef Hafez MA, Chelule KL, Seedhom BB, Sherman KP (2006) Computer-assisted total knee arthroplasty using patient-specific templating. Clin Orthop Relat Res 444:184PubMedCrossRef
2.
Zurück zum Zitat Ng VY, DeClaire JH, Berend KR, Gulick BC, Lombardi AV Jr (2012) Improved accuracy of alignment with patient-specific positioning guides compared with manual instrumentation in TKA. Clin Orthop Relat Res 470(1):99PubMedCrossRefPubMedCentral Ng VY, DeClaire JH, Berend KR, Gulick BC, Lombardi AV Jr (2012) Improved accuracy of alignment with patient-specific positioning guides compared with manual instrumentation in TKA. Clin Orthop Relat Res 470(1):99PubMedCrossRefPubMedCentral
3.
Zurück zum Zitat Nunley RM, Ellison BS, Zhu J, Ruh EL, Howell SM, Barrack RL (2012) Do patient-specific guides improve coronal alignment in total knee arthroplasty? Clin Orthop Relat Res 470(3):895PubMedCrossRefPubMedCentral Nunley RM, Ellison BS, Zhu J, Ruh EL, Howell SM, Barrack RL (2012) Do patient-specific guides improve coronal alignment in total knee arthroplasty? Clin Orthop Relat Res 470(3):895PubMedCrossRefPubMedCentral
4.
Zurück zum Zitat Spencer BA, Mont MA, McGrath MS, Boyd B, Mitrick MF (2009) Initial experience with custom-fit total knee replacement: intra-operative events and long-leg coronal alignment. Int Orthop 33(6):1571PubMedCrossRefPubMedCentral Spencer BA, Mont MA, McGrath MS, Boyd B, Mitrick MF (2009) Initial experience with custom-fit total knee replacement: intra-operative events and long-leg coronal alignment. Int Orthop 33(6):1571PubMedCrossRefPubMedCentral
5.
Zurück zum Zitat Nunley RM, Ellison BS, Ruh EL, Williams BM, Foreman K, Ford AD, Barrack RL (2012) Are patient-specific cutting blocks cost-effective for total knee arthroplasty? Clin Orthop Relat Res 470(3):889PubMedCrossRefPubMedCentral Nunley RM, Ellison BS, Ruh EL, Williams BM, Foreman K, Ford AD, Barrack RL (2012) Are patient-specific cutting blocks cost-effective for total knee arthroplasty? Clin Orthop Relat Res 470(3):889PubMedCrossRefPubMedCentral
6.
Zurück zum Zitat Bathis H, Perlick L, Tingart M, Luring C, Zurakowski D, Grifka J (2004) Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique. J Bone Jt Surg Br 86(5):682CrossRef Bathis H, Perlick L, Tingart M, Luring C, Zurakowski D, Grifka J (2004) Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique. J Bone Jt Surg Br 86(5):682CrossRef
7.
Zurück zum Zitat Chauhan SK, Scott RG, Breidahl W, Beaver RJ (2004) Computer-assisted knee arthroplasty versus a conventional jig-based technique. A randomised, prospective trial. J Bone Jt Surg Br 86(3): 372 Chauhan SK, Scott RG, Breidahl W, Beaver RJ (2004) Computer-assisted knee arthroplasty versus a conventional jig-based technique. A randomised, prospective trial. J Bone Jt Surg Br 86(3): 372
8.
Zurück zum Zitat Chin PL, Yang KY, Yeo SJ, Lo NN (2005) Randomized control trial comparing radiographic total knee arthroplasty implant placement using computer navigation versus conventional technique. J Arthroplast 20(5):618CrossRef Chin PL, Yang KY, Yeo SJ, Lo NN (2005) Randomized control trial comparing radiographic total knee arthroplasty implant placement using computer navigation versus conventional technique. J Arthroplast 20(5):618CrossRef
9.
Zurück zum Zitat Decking R, Markmann Y, Fuchs J, Puhl W, Scharf HP (2005) Leg axis after computer-navigated total knee arthroplasty: a prospective randomized trial comparing computer-navigated and manual implantation. J Arthroplast 20(3):282CrossRef Decking R, Markmann Y, Fuchs J, Puhl W, Scharf HP (2005) Leg axis after computer-navigated total knee arthroplasty: a prospective randomized trial comparing computer-navigated and manual implantation. J Arthroplast 20(3):282CrossRef
10.
Zurück zum Zitat Haaker RG, Stockheim M, Kamp M, Proff G, Breitenfelder J, Ottersbach A (2005) Computer-assisted navigation increases precision of component placement in total knee arthroplasty. Clin Orthop Relat Res 433:152PubMedCrossRef Haaker RG, Stockheim M, Kamp M, Proff G, Breitenfelder J, Ottersbach A (2005) Computer-assisted navigation increases precision of component placement in total knee arthroplasty. Clin Orthop Relat Res 433:152PubMedCrossRef
11.
Zurück zum Zitat Jenny JY, Boeri C (2001) Computer-assisted implantation of a total knee arthroplasty: a case-controlled study in comparison with classical instrumentation. Rev Chir Orthop Reparatrice Appar Mot 87(7):645PubMed Jenny JY, Boeri C (2001) Computer-assisted implantation of a total knee arthroplasty: a case-controlled study in comparison with classical instrumentation. Rev Chir Orthop Reparatrice Appar Mot 87(7):645PubMed
12.
Zurück zum Zitat Sparmann M, Wolke B, Czupalla H, Banzer D, Zink A (2003) Positioning of total knee arthroplasty with and without navigation support. A prospective, randomised, study. J Bone Jt Surg Br 85(6):830 Sparmann M, Wolke B, Czupalla H, Banzer D, Zink A (2003) Positioning of total knee arthroplasty with and without navigation support. A prospective, randomised, study. J Bone Jt Surg Br 85(6):830
13.
Zurück zum Zitat Stockl B, Nogler M, Rosiek R, Fischer M, Krismer M, Kessler O (2004) Navigation improves accuracy of rotational alignment in total knee arthroplasty. Clin Orthop Relat Res 426:180PubMedCrossRef Stockl B, Nogler M, Rosiek R, Fischer M, Krismer M, Kessler O (2004) Navigation improves accuracy of rotational alignment in total knee arthroplasty. Clin Orthop Relat Res 426:180PubMedCrossRef
14.
Zurück zum Zitat Hiscox CM, Bohm ER, Turgeon TR, Hedden DR, Burnell CD (2011) Randomized trial of computer-assisted knee arthroplasty: impact on clinical and radiographic outcomes. J Arthroplast 26(8):1259CrossRef Hiscox CM, Bohm ER, Turgeon TR, Hedden DR, Burnell CD (2011) Randomized trial of computer-assisted knee arthroplasty: impact on clinical and radiographic outcomes. J Arthroplast 26(8):1259CrossRef
15.
Zurück zum Zitat Harvie P, Sloan K, Beaver RJ (2011) Three-dimensional component alignment and functional outcome in computer-navigated total knee arthroplasty: a prospective, randomized study comparing two navigation systems. J Arthroplast 26(8):1285CrossRef Harvie P, Sloan K, Beaver RJ (2011) Three-dimensional component alignment and functional outcome in computer-navigated total knee arthroplasty: a prospective, randomized study comparing two navigation systems. J Arthroplast 26(8):1285CrossRef
16.
Zurück zum Zitat Dutton AQ, Yeo SJ (2009) Computer-assisted minimally invasive total knee arthroplasty compared with standard total knee arthroplasty surgical technique. J Bone Jt Surg Am 91(Suppl 2 Pt 1):116CrossRef Dutton AQ, Yeo SJ (2009) Computer-assisted minimally invasive total knee arthroplasty compared with standard total knee arthroplasty surgical technique. J Bone Jt Surg Am 91(Suppl 2 Pt 1):116CrossRef
17.
Zurück zum Zitat Hernandez-Vaquero D, Suarez-Vazquez A, Iglesias-Fernandez S (2011) Can computer assistance improve the clinical and functional scores in total knee arthroplasty? Clin Orthop Relat Res 469(12):3436PubMedCrossRefPubMedCentral Hernandez-Vaquero D, Suarez-Vazquez A, Iglesias-Fernandez S (2011) Can computer assistance improve the clinical and functional scores in total knee arthroplasty? Clin Orthop Relat Res 469(12):3436PubMedCrossRefPubMedCentral
18.
Zurück zum Zitat Barrett WP, Mason JB, Moskal JT, Dalury DF, Oliashirazi A, Fisher DA (2011) Comparison of radiographic alignment of imageless computer-assisted surgery versus conventional instrumentation in primary total knee arthroplasty. J Arthroplast 26(8):1273CrossRef Barrett WP, Mason JB, Moskal JT, Dalury DF, Oliashirazi A, Fisher DA (2011) Comparison of radiographic alignment of imageless computer-assisted surgery versus conventional instrumentation in primary total knee arthroplasty. J Arthroplast 26(8):1273CrossRef
19.
Zurück zum Zitat Martin A, Wohlgenannt O, Prenn M, Oelsch C, von Strempel A (2007) Imageless navigation for TKA increases implantation accuracy. Clin Orthop Relat Res 460:178PubMed Martin A, Wohlgenannt O, Prenn M, Oelsch C, von Strempel A (2007) Imageless navigation for TKA increases implantation accuracy. Clin Orthop Relat Res 460:178PubMed
20.
Zurück zum Zitat Martin A, von Strempel A (2006) Two-year outcomes of computed tomography-based and computed tomography free navigation for total knee arthroplasties. Clin Orthop Relat Res 449:275PubMed Martin A, von Strempel A (2006) Two-year outcomes of computed tomography-based and computed tomography free navigation for total knee arthroplasties. Clin Orthop Relat Res 449:275PubMed
21.
Zurück zum Zitat Victor J, Hoste D (2004) Image-based computer-assisted total knee arthroplasty leads to lower variability in coronal alignment. Clin Orthop Relat Res 428:131PubMedCrossRef Victor J, Hoste D (2004) Image-based computer-assisted total knee arthroplasty leads to lower variability in coronal alignment. Clin Orthop Relat Res 428:131PubMedCrossRef
22.
Zurück zum Zitat Matziolis G, Krocker D, Weiss U, Tohtz S, Perka C (2007) A prospective, randomized study of computer-assisted and conventional total knee arthroplasty three-dimensional evaluation of implant alignment and rotation. J Bone Jt Surg Am 89(2):236CrossRef Matziolis G, Krocker D, Weiss U, Tohtz S, Perka C (2007) A prospective, randomized study of computer-assisted and conventional total knee arthroplasty three-dimensional evaluation of implant alignment and rotation. J Bone Jt Surg Am 89(2):236CrossRef
23.
Zurück zum Zitat Kamat YD, Aurakzai KM, Adhikari AR, Matthews D, Kalairajah Y, Field RE (2009) Does computer navigation in total knee arthroplasty improve patient outcome at midterm follow-up? Int Orthop 33(6):1567PubMedCrossRefPubMedCentral Kamat YD, Aurakzai KM, Adhikari AR, Matthews D, Kalairajah Y, Field RE (2009) Does computer navigation in total knee arthroplasty improve patient outcome at midterm follow-up? Int Orthop 33(6):1567PubMedCrossRefPubMedCentral
24.
Zurück zum Zitat Molfetta L, Caldo D (2008) Computer navigation versus conventional implantation for varus knee total arthroplasty: a case-control study at 5 years follow-up. Knee 15(2):75PubMedCrossRef Molfetta L, Caldo D (2008) Computer navigation versus conventional implantation for varus knee total arthroplasty: a case-control study at 5 years follow-up. Knee 15(2):75PubMedCrossRef
25.
Zurück zum Zitat Spencer JM, Chauhan SK, Sloan K, Taylor A, Beaver RJ (2007) Computer navigation versus conventional total knee replacement: no difference in functional results at 2 years. J Bone Jt Surg Br 89(4):477CrossRef Spencer JM, Chauhan SK, Sloan K, Taylor A, Beaver RJ (2007) Computer navigation versus conventional total knee replacement: no difference in functional results at 2 years. J Bone Jt Surg Br 89(4):477CrossRef
26.
Zurück zum Zitat Ensini A, Catani F, Leardini A, Romagnoli M, Giannini S (2007) Alignments and clinical results in conventional and navigated total knee arthroplasty. Clin Orthop Relat Res 457:156 Ensini A, Catani F, Leardini A, Romagnoli M, Giannini S (2007) Alignments and clinical results in conventional and navigated total knee arthroplasty. Clin Orthop Relat Res 457:156
27.
Zurück zum Zitat Stulberg SD, Yaffe MA, Koo SS (2006) Computer-assisted surgery versus manual total knee arthroplasty: a case-controlled study. J Bone Jt Surg Am 88(Suppl 4):47 Stulberg SD, Yaffe MA, Koo SS (2006) Computer-assisted surgery versus manual total knee arthroplasty: a case-controlled study. J Bone Jt Surg Am 88(Suppl 4):47
28.
Zurück zum Zitat Goebel D, Schultz W (2012) The Columbus knee system: 4-year results of a new deep flexion design compared to the NexGen full flex implant. Arthritis 2012:213817 Goebel D, Schultz W (2012) The Columbus knee system: 4-year results of a new deep flexion design compared to the NexGen full flex implant. Arthritis 2012:213817
29.
Zurück zum Zitat Yaffe M, Chan P, Goyal N, Luo M, Cayo M, Stulberg SD (2013) Computer-assisted versus manual TKA: no difference in clinical or functional outcomes at 5-year follow-up. Orthopedics 36(5):e627 Yaffe M, Chan P, Goyal N, Luo M, Cayo M, Stulberg SD (2013) Computer-assisted versus manual TKA: no difference in clinical or functional outcomes at 5-year follow-up. Orthopedics 36(5):e627
30.
Zurück zum Zitat Yaffe MA, Koo SS, Stulberg SD (2008) Radiographic and navigation measurements of TKA limb alignment do not correlate. Clin Orthop Relat Res 466:2736–2744 Yaffe MA, Koo SS, Stulberg SD (2008) Radiographic and navigation measurements of TKA limb alignment do not correlate. Clin Orthop Relat Res 466:2736–2744
31.
Zurück zum Zitat Brouwer RW, Jakma TS, Brouwer KH, Verhaar JA (2007) Pitfalls in determining knee alignment: a radiographic cadaver study. J Knee Surg 20(3):210PubMed Brouwer RW, Jakma TS, Brouwer KH, Verhaar JA (2007) Pitfalls in determining knee alignment: a radiographic cadaver study. J Knee Surg 20(3):210PubMed
32.
Zurück zum Zitat Hunt MA, Fowler PJ, Birmingham TB, Jenkyn TR, Giffin JR (2006) Foot rotational effects on radiographic measures of lower limb alignment. Can J Surg 49(6):401PubMedPubMedCentral Hunt MA, Fowler PJ, Birmingham TB, Jenkyn TR, Giffin JR (2006) Foot rotational effects on radiographic measures of lower limb alignment. Can J Surg 49(6):401PubMedPubMedCentral
33.
Zurück zum Zitat Lonner JH, Laird MT, Stuchin SA (1996) Effect of rotation and knee flexion on radiographic alignment in total knee arthroplasties. Clin Orthop Relat Res 331:102PubMedCrossRef Lonner JH, Laird MT, Stuchin SA (1996) Effect of rotation and knee flexion on radiographic alignment in total knee arthroplasties. Clin Orthop Relat Res 331:102PubMedCrossRef
34.
Zurück zum Zitat Senden R (2012) High variability in Knee Society Score between studies: how reliable is the Knee Society Score? In: AAOS 2012 annual meeting. San Francisco, CA Senden R (2012) High variability in Knee Society Score between studies: how reliable is the Knee Society Score? In: AAOS 2012 annual meeting. San Francisco, CA
35.
Zurück zum Zitat Ghanem E, Pawasarat I, Lindsay A, May L, Azzam K, Joshi A, Parvizi J (2010) Limitations of the Knee Society Score in evaluating outcomes following revision total knee arthroplasty. J Bone Jt Surg Am 92(14):2445CrossRef Ghanem E, Pawasarat I, Lindsay A, May L, Azzam K, Joshi A, Parvizi J (2010) Limitations of the Knee Society Score in evaluating outcomes following revision total knee arthroplasty. J Bone Jt Surg Am 92(14):2445CrossRef
Metadaten
Titel
Clinical, functional, and radiographic outcomes following total knee arthroplasty with patient-specific instrumentation, computer-assisted surgery, and manual instrumentation: a short-term follow-up study
verfasst von
Mark Yaffe
Michael Luo
Nitin Goyal
Philip Chan
Anay Patel
Max Cayo
S. David Stulberg
Publikationsdatum
01.09.2014
Verlag
Springer Berlin Heidelberg
Erschienen in
International Journal of Computer Assisted Radiology and Surgery / Ausgabe 5/2014
Print ISSN: 1861-6410
Elektronische ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-013-0968-6

Weitere Artikel der Ausgabe 5/2014

International Journal of Computer Assisted Radiology and Surgery 5/2014 Zur Ausgabe