Skip to main content

2022 | OriginalPaper | Buchkapitel

6. Closed-Loop Correction Strategies

verfasst von : Feng Gao, Tao Xu

Erschienen in: Coordination and Optimization of Grid-Tied Power Converters

Verlag: Springer Singapore

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

In order to further improve the adaptivity of PWM coordination, the closed-loop correction strategies are presented in this chapter. It begins with the basic concept and presents the closed-loop correction strategy for multi-input single-output (MISO) systems. Then, the “Min–Max” closed-loop correction strategy for multi-input multi-output (MIMO) systems is elaborated.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Xu T, Gao F, Tan P et al (2020) Parameters uncertainty immunization of global synchronous pulse width modulated VSIs with round P&O algorithm. IEEE Trans Power Electron 35(11):11281–11286CrossRef Xu T, Gao F, Tan P et al (2020) Parameters uncertainty immunization of global synchronous pulse width modulated VSIs with round P&O algorithm. IEEE Trans Power Electron 35(11):11281–11286CrossRef
2.
Zurück zum Zitat Morched S, Kundur P (1987) Identification and modelling of load characteristics at high frequencies. IEEE Trans Power Syst 2(1):153–159CrossRef Morched S, Kundur P (1987) Identification and modelling of load characteristics at high frequencies. IEEE Trans Power Syst 2(1):153–159CrossRef
3.
Zurück zum Zitat Girgis A, McManis RB (1989) Frequency domain techniques for modeling distribution or transmission networks using capacitor switching induced transients. IEEE Trans Power Del 4(3):1882–1890CrossRef Girgis A, McManis RB (1989) Frequency domain techniques for modeling distribution or transmission networks using capacitor switching induced transients. IEEE Trans Power Del 4(3):1882–1890CrossRef
4.
Zurück zum Zitat Ahmed J, Salam Z (2018) An enhanced adaptive P&O MPPT for fast and efficient tracking under varying environmental conditions. IEEE Trans Sustain Energy 9(3):1487–1496CrossRef Ahmed J, Salam Z (2018) An enhanced adaptive P&O MPPT for fast and efficient tracking under varying environmental conditions. IEEE Trans Sustain Energy 9(3):1487–1496CrossRef
5.
Zurück zum Zitat Prasanth JR, Rajasekar N (2017) A novel flower pollination based global maximum power point method for solar maximum power point tracking. IEEE Trans Power Electron 32(11):8486–8499CrossRef Prasanth JR, Rajasekar N (2017) A novel flower pollination based global maximum power point method for solar maximum power point tracking. IEEE Trans Power Electron 32(11):8486–8499CrossRef
6.
Zurück zum Zitat Zhang W, Zhou G, Ni H et al (2019) A modified hybrid maximum power point tracking method for photovoltaic arrays under partially shading condition. IEEE Access 7:160091–160100CrossRef Zhang W, Zhou G, Ni H et al (2019) A modified hybrid maximum power point tracking method for photovoltaic arrays under partially shading condition. IEEE Access 7:160091–160100CrossRef
7.
Zurück zum Zitat Xu T, Gao F, Zhou K et al (2021) A min-max closed-loop PLL-GSPWM for circulating leakage currents attenuation in PV station. IEEE Trans Power Electron 36(9):10224–10238CrossRef Xu T, Gao F, Zhou K et al (2021) A min-max closed-loop PLL-GSPWM for circulating leakage currents attenuation in PV station. IEEE Trans Power Electron 36(9):10224–10238CrossRef
8.
Zurück zum Zitat Xu T, Gao F, Hao T et al (2018) Two-layer global synchronous pulse width modulation method for attenuating circulating leakage current in PV station. IEEE Trans Ind Electron 65(10):8005–8017CrossRef Xu T, Gao F, Hao T et al (2018) Two-layer global synchronous pulse width modulation method for attenuating circulating leakage current in PV station. IEEE Trans Ind Electron 65(10):8005–8017CrossRef
10.
Zurück zum Zitat Liao YH, Chen HC (2015) Simplified PWM with switching constraint method to prevent circulating currents for paralleled bidirectional AC/DC converters in grid-tied system using graphic analysis. IEEE Trans Ind Electron 62(7):4573–4586CrossRef Liao YH, Chen HC (2015) Simplified PWM with switching constraint method to prevent circulating currents for paralleled bidirectional AC/DC converters in grid-tied system using graphic analysis. IEEE Trans Ind Electron 62(7):4573–4586CrossRef
Metadaten
Titel
Closed-Loop Correction Strategies
verfasst von
Feng Gao
Tao Xu
Copyright-Jahr
2022
Verlag
Springer Singapore
DOI
https://doi.org/10.1007/978-981-16-7446-4_6

Neuer Inhalt