Skip to main content

2021 | OriginalPaper | Buchkapitel

Comparative Analysis of Small and Large Capacity Sized On-grid, Rooftop Solar PV Systems - An LCA Approach

verfasst von : N. Leela Prasad, M. Shreyas, P. Usha Sri

Erschienen in: Recent Trends in Mechanical Engineering

Verlag: Springer Singapore

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Due to scarce hydrocarbon reserves in India, majorly Coal and to some extent Nuclear remain the most dependable sources of energy in near future, to meet the ever-growing demand for energy in its instant form, i.e. Electricity. Renewables such as Solar PV and Wind are relatively clean sources of electricity, but they have their own drawbacks in terms of potential, penetration, technology and the scale of deployment. But these options can supplement our energy needs to some extent. A comparative LCA study of two different capacity sized and grid-connected Solar PV systems installed on the flat rooftop of buildings located at different geographical sites within India is carried out by modelling them to run on SimaPro 9.0.0.48 LCA software with ECOINVENT 3 as database. This study covers all-important Inventory Analysis for the inputs used in terms of energy and materials, outputs resulted in terms of energy and environmental releases. The study results are expressed in the form of predefined energy metrics such as CED and EPBT. Further, this study covers the environmental impact assessment category such as GWP, and the result is presented with kWh of electricity produced by these systems as a functional unit. Further, these investigations help energy planners and policymakers to compare various power generating options and also the same option with varied capacities so that the decision on future investments in the power sector can be made in a more justifiable manner for a clean and sustainable future.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Fußnoten
1
The average rating of a 100 kWp rated poly-Si PV system at operating conditions will be 90.3 kWp only. The average rating is taken at the lowest possible value because of PV Array loss factors like Thermal Loss Factor, Wiring Ohmic Loss, Module Quality Loss, Module Mismatch Loss, DC to AC Conversion Losses at 98.2% and Incidence Effect.
 
2
Average sunshine is taken as 5.5 h/day throughout the year.
 
3
The average rating of a 1.4 MWp rated poly-Si PV system at operating conditions will be 1.26 MWp only. The average rating is taken at the lowest possible value because of PV Array loss factors like Thermal Loss Factor, Wiring Ohmic Loss, Module Quality Loss, Module Mismatch Loss, DC to AC Conversion Losses at 98.2% and Incidence Effect.
 
4
Average sunshine is taken as 5.5 h/day throughout the year.
 
Literatur
1.
Zurück zum Zitat G. Finnveden, A. Moberg, Environmental systems analysis tools—an overview. J. Clean. Prod. 13, 1165–1173 (2005)CrossRef G. Finnveden, A. Moberg, Environmental systems analysis tools—an overview. J. Clean. Prod. 13, 1165–1173 (2005)CrossRef
2.
Zurück zum Zitat Software SimaPro 9.0.0.48, PRé Consultants, Amersfoort, NL (2019) Software SimaPro 9.0.0.48, PRé Consultants, Amersfoort, NL (2019)
3.
Zurück zum Zitat ECOINVENT 3.0 Database. The Ecoinvent Centre, Swiss Centre for Life Cycle Inventories: Duebendorf, Switzerland (2015) ECOINVENT 3.0 Database. The Ecoinvent Centre, Swiss Centre for Life Cycle Inventories: Duebendorf, Switzerland (2015)
4.
Zurück zum Zitat System Construction and Materials Data, Novus Green Energy Systems, Hyderabad (2015) System Construction and Materials Data, Novus Green Energy Systems, Hyderabad (2015)
5.
Zurück zum Zitat System Construction and Materials Data, Samruddhi Renewables Solution, Bengaluru (2018) System Construction and Materials Data, Samruddhi Renewables Solution, Bengaluru (2018)
6.
Zurück zum Zitat M. Lenzen, Life cycle energy and greenhouse gas emissions of nuclear energy: a review. Energy Convers. Manage. 49, 2178–2199 (2008)CrossRef M. Lenzen, Life cycle energy and greenhouse gas emissions of nuclear energy: a review. Energy Convers. Manage. 49, 2178–2199 (2008)CrossRef
Metadaten
Titel
Comparative Analysis of Small and Large Capacity Sized On-grid, Rooftop Solar PV Systems - An LCA Approach
verfasst von
N. Leela Prasad
M. Shreyas
P. Usha Sri
Copyright-Jahr
2021
Verlag
Springer Singapore
DOI
https://doi.org/10.1007/978-981-15-7557-0_48

    Marktübersichten

    Die im Laufe eines Jahres in der „adhäsion“ veröffentlichten Marktübersichten helfen Anwendern verschiedenster Branchen, sich einen gezielten Überblick über Lieferantenangebote zu verschaffen.