Skip to main content
main-content

Tipp

Weitere Artikel dieser Ausgabe durch Wischen aufrufen

01.10.2011 | Ausgabe 4/2011

Fire Technology 4/2011

Compressive Response of Composites Under Combined Fire and Compression Loading

Zeitschrift:
Fire Technology > Ausgabe 4/2011
Autoren:
Liu Liu, John W. Holmes, George A. Kardomateas, Victor Birman

Abstract

The thermal buckling of an axially restrained composite column that is exposed to a heat flux due to fire is studied by both analytical and experimental means. The column is exposed to fire from one-side and the resulting heat damage, the charred layer formation and non-uniform transient temperature distribution are calculated by the thermal model developed by Gibson et al. (Revue de l’Institute Francais du Petrole 50:69–74, 1995). For the thermal buckling analysis, the mechanical properties of the fire-damaged (charred) region are considered negligible; the degradation of the elastic properties with temperature (especially near the glass transition temperature of the matrix) in the undamaged layer, is accounted for by using experimental data for the elastic moduli. Due to the non-uniform stiffness and the effect of the ensuing thermal moment, the structure behaves like an imperfect column, and responds by bending rather than buckling in the classical Euler (bifurcation) sense. Another important effect of the non-uniform temperature is that the neutral axis moves away from the centroid of the cross section, resulting in another moment due to eccentric loading, which would tend to bend the structure away from the fire. In order to verify the mechanical response, the compressive buckling behavior of the same material subjected to simultaneous high intensity surface heating and axial compressive loading were investigated experimentally. Fire exposure was simulated by subjecting the surface of rectangular specimens to radiant heating in a cone calorimeter. Heat flux levels of 25 kW/m2, 50 kW/m2 and 75 kW/m2 were studied. All specimens exhibited buckling and subsequent catastrophic failure, even at compressive stresses as low as 3.5 MPa under a surface heat flux of 25 kW/m2. Details of the experimental procedure, including modifications made to a cone calorimeter to allow simultaneous mechanical loading are presented.

Bitte loggen Sie sich ein, um Zugang zu diesem Inhalt zu erhalten

Sie möchten Zugang zu diesem Inhalt erhalten? Dann informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 50.000 Bücher
  • über 380 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Umwelt
  • Maschinenbau + Werkstoffe​​​​​​​​​​​​​​

Testen Sie jetzt 30 Tage kostenlos.

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 69.000 Bücher
  • über 500 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Umwelt
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe

Testen Sie jetzt 30 Tage kostenlos.

Literatur
Über diesen Artikel

Weitere Artikel der Ausgabe 4/2011

Fire Technology 4/2011 Zur Ausgabe