Hypertension is one of the leading risk factors for several diseases. Measurement and monitoring of blood pressure anytime and anywhere are important to lower blood pressure and prevent pathogenesis of diseases. Non-contact blood pressure measurement is desired to monitor blood pressure anytime and anywhere. The aim of this study was to develop a non-contact blood pressure sensing system. A previous study reported that amplitude and time differences of facial photoplethysmogram (PPG) components extracted using brightness variation of facial skin color in facial visible images could be useful indices for estimating blood pressure. The maximum error between measured and estimated blood pressure using facial PPG components was 12 mmHg. An additional signal processing algorithm is desired to increase the accuracy for estimating blood pressure using facial PPG components. By contrast, facial skin temperature also reflects changes in the facial blood circulation. High-accuracy estimation of blood pressure could be expected using both facial PPG components and facial skin temperature. In this study, improvement of accuracy for estimating blood pressure using facial PPG components by attempting to apply additional signal processing to facial skin color variation. Furthermore, a correlation analysis between facial skin temperature and measured blood pressure was performed, and individual models for blood pressure estimation were created.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Frostegard J (2013) Immunity, atherosclerosis and cardiovascular disease. BMC Med 11:117CrossRef Frostegard J (2013) Immunity, atherosclerosis and cardiovascular disease. BMC Med 11:117CrossRef
2.
Zurück zum Zitat Kudo C, Shin WS, Sasaki N, Harai K, Kato K, Seino H, Goke E, Fujino T, Kuribayashi N, Onuki Pearce Y, Taira M, Matsushima R, Minabe M, Takashiba S (2018) Effects of periodontal treatment on carotid intima-media thickness in patients with lifestyle-related diseases: Japanese prospective multicentre observational study, Odontology, pp 1–12 Kudo C, Shin WS, Sasaki N, Harai K, Kato K, Seino H, Goke E, Fujino T, Kuribayashi N, Onuki Pearce Y, Taira M, Matsushima R, Minabe M, Takashiba S (2018) Effects of periodontal treatment on carotid intima-media thickness in patients with lifestyle-related diseases: Japanese prospective multicentre observational study, Odontology, pp 1–12
3.
Zurück zum Zitat Halme L, Vesalainen R, Kaaja M, Kantola I (2005) Self-monitoring of blood pressure promotes achievement of blood pressure target in primary health care. Am J Hypertens 18:1415–1420CrossRef Halme L, Vesalainen R, Kaaja M, Kantola I (2005) Self-monitoring of blood pressure promotes achievement of blood pressure target in primary health care. Am J Hypertens 18:1415–1420CrossRef
4.
Zurück zum Zitat Yong P, Geddes LA (1990) A surrogate arm for evaluating the accuracy of instruments for indirect measurement of blood pressure. Biomed Instrum Technol 24:130–135 Yong P, Geddes LA (1990) A surrogate arm for evaluating the accuracy of instruments for indirect measurement of blood pressure. Biomed Instrum Technol 24:130–135
5.
Zurück zum Zitat van Popele NM, Grobbee DE, Bots ML, Asmar R, Topouchian J, Reneman RS, Hoeks APG, van der Kuip DAM, Hofman A, Witteman JCM (2001) Association between arterial stiffness and atherosclerosis the rotterdam study. Stroke 32:454–460CrossRef van Popele NM, Grobbee DE, Bots ML, Asmar R, Topouchian J, Reneman RS, Hoeks APG, van der Kuip DAM, Hofman A, Witteman JCM (2001) Association between arterial stiffness and atherosclerosis the rotterdam study. Stroke 32:454–460CrossRef
6.
Zurück zum Zitat Poon CCY, Zhang YT (2006) Cuff-less and noninvasive measurements of arterial blood pressure by pulse transit time, engineering in medicine and biology society, 2005. In: IEEE-EMBS 2005. 27th Annual International Conference of the. IEEE, pp 5877–5880 Poon CCY, Zhang YT (2006) Cuff-less and noninvasive measurements of arterial blood pressure by pulse transit time, engineering in medicine and biology society, 2005. In: IEEE-EMBS 2005. 27th Annual International Conference of the. IEEE, pp 5877–5880
7.
Zurück zum Zitat Kim HL, Seo JB, Chung WY, Kim SH, Zo JH, Kim MA (2015) The association between ambulatory blood pressure profile and Brachialankle pulse wave velocity in untreated hypertensive subjects. Blood Press 24:139–146CrossRef Kim HL, Seo JB, Chung WY, Kim SH, Zo JH, Kim MA (2015) The association between ambulatory blood pressure profile and Brachialankle pulse wave velocity in untreated hypertensive subjects. Blood Press 24:139–146CrossRef
8.
Zurück zum Zitat Jonathan E, Leahy M (2010) Investigating a smartphone imaging unit for photoplethysmography. Physiol Meas 31:N79CrossRef Jonathan E, Leahy M (2010) Investigating a smartphone imaging unit for photoplethysmography. Physiol Meas 31:N79CrossRef
9.
Zurück zum Zitat Scully CG, Lee J, Meyer J, Gorbach AM, Granquist-Fraser D, Mendelson Y, Chon KH (2012) Physiological parameter monitoring from optical recordings with a mobile phone. IEEE Trans Biomed Eng 59:303–306CrossRef Scully CG, Lee J, Meyer J, Gorbach AM, Granquist-Fraser D, Mendelson Y, Chon KH (2012) Physiological parameter monitoring from optical recordings with a mobile phone. IEEE Trans Biomed Eng 59:303–306CrossRef
10.
Zurück zum Zitat Chandrasekaran V, Dantu R, Jonnada S, Thiyagaraja S, Subbu KP (2013) Cuffless differential blood pressure estimation using smart phones. IEEE Trans Biomed Eng 60:1080–1089CrossRef Chandrasekaran V, Dantu R, Jonnada S, Thiyagaraja S, Subbu KP (2013) Cuffless differential blood pressure estimation using smart phones. IEEE Trans Biomed Eng 60:1080–1089CrossRef
11.
Zurück zum Zitat Jain M, Deb S, Subramanyam AV (2016) Face video based touchless blood pressure and heart rate estimation. In: 2016 IEEE 18th International Workshop on Multimedia Signal Processing (MMSP). IEEE, pp 1–5 Jain M, Deb S, Subramanyam AV (2016) Face video based touchless blood pressure and heart rate estimation. In: 2016 IEEE 18th International Workshop on Multimedia Signal Processing (MMSP). IEEE, pp 1–5
12.
Zurück zum Zitat Uppal G, Prakash NR, Kalra P (2017) Heart rate measurement using facial videos. Adv Comput Sci Technol 10:2343–2357 Uppal G, Prakash NR, Kalra P (2017) Heart rate measurement using facial videos. Adv Comput Sci Technol 10:2343–2357
13.
Zurück zum Zitat Oiwa K, Bando S, Nozawa A (2017) Attempt of non-contact vital sign sensing by facial visual image analysis. In: 2017 Annual Conference of Electronics, Information and Systems Society, IEEJ, OS5–8 Oiwa K, Bando S, Nozawa A (2017) Attempt of non-contact vital sign sensing by facial visual image analysis. In: 2017 Annual Conference of Electronics, Information and Systems Society, IEEJ, OS5–8
14.
Zurück zum Zitat Nozawa A, Karita K (2010) Emotion spectrum analysis for a daily repetitive mental workload. Artif Life Robot 15:316–319CrossRef Nozawa A, Karita K (2010) Emotion spectrum analysis for a daily repetitive mental workload. Artif Life Robot 15:316–319CrossRef
15.
Zurück zum Zitat Ioannou S, Gallese V, Merla A (2014) Thermal infrared imaging in psychophysiology: potentialities and limits. Psychophysiology 51:951–963CrossRef Ioannou S, Gallese V, Merla A (2014) Thermal infrared imaging in psychophysiology: potentialities and limits. Psychophysiology 51:951–963CrossRef
16.
Zurück zum Zitat Yang M, Liu Q, Turner T, Wu Y (2008) Vital sign estimation from passive thermal video. In: IEEE conference on computer vision and pattern recognition, 2008. CVPR 2008. IEEE, pp. 1–8 Yang M, Liu Q, Turner T, Wu Y (2008) Vital sign estimation from passive thermal video. In: IEEE conference on computer vision and pattern recognition, 2008. CVPR 2008. IEEE, pp. 1–8
17.
Zurück zum Zitat Sun G, Nakayama Y, Dagdanpurev S, Abe S, Nishimura H, Kirimoto T, Matsui T (2017) Remote sensing of multiple vital signs using a CMOS camera-equipped infrared thermography system and its clinical application in rapidly screening patients with suspected infectious diseases. Int J Infect Dis 55:113–117CrossRef Sun G, Nakayama Y, Dagdanpurev S, Abe S, Nishimura H, Kirimoto T, Matsui T (2017) Remote sensing of multiple vital signs using a CMOS camera-equipped infrared thermography system and its clinical application in rapidly screening patients with suspected infectious diseases. Int J Infect Dis 55:113–117CrossRef
18.
Zurück zum Zitat Kato S, Nakagawa T, Ohkawa M, Muramoto K, Oyama O, Watanabe A, Nakashima H, Nomoto T, Sugitani K (2004) A computer image processing system for quantification of Zebrafish Behavior. J Neurosci Methods 134:1–7CrossRef Kato S, Nakagawa T, Ohkawa M, Muramoto K, Oyama O, Watanabe A, Nakashima H, Nomoto T, Sugitani K (2004) A computer image processing system for quantification of Zebrafish Behavior. J Neurosci Methods 134:1–7CrossRef
19.
Zurück zum Zitat Hyvärinen A (1997) Fast and robust fixed-point algorithms for independent component analysis. Neural Comput 9:1483–1492CrossRef Hyvärinen A (1997) Fast and robust fixed-point algorithms for independent component analysis. Neural Comput 9:1483–1492CrossRef
20.
Zurück zum Zitat Pinar YA, Bilge O, Govsa F (2005) Anatomic study of the blood supply of perioral region. Clin Anat 18:330–339CrossRef Pinar YA, Bilge O, Govsa F (2005) Anatomic study of the blood supply of perioral region. Clin Anat 18:330–339CrossRef
21.
Zurück zum Zitat Pilsl U, Anderhuber F, Rzany (2012) Anatomy of the cheek: implications for soft tissue augmentation. Dermatol Surg 38:1254–1262 Pilsl U, Anderhuber F, Rzany (2012) Anatomy of the cheek: implications for soft tissue augmentation. Dermatol Surg 38:1254–1262
22.
Zurück zum Zitat Kachuee M, Kiani MM, Mohammadzade H (2017) Cuffless Blood Pressure Estimation Algorithms for Continuous Health-Care Monitoring. IEEE Trans Biomed Eng 64:859–869CrossRef Kachuee M, Kiani MM, Mohammadzade H (2017) Cuffless Blood Pressure Estimation Algorithms for Continuous Health-Care Monitoring. IEEE Trans Biomed Eng 64:859–869CrossRef
23.
Zurück zum Zitat Japan Society of Physiological Anthropology (1996) Human measurement hand book. Asakura Shobo Japan Society of Physiological Anthropology (1996) Human measurement hand book. Asakura Shobo
Metadaten
Titel
Contactless blood pressure sensing using facial visible and thermal images
verfasst von
Kosuke Oiwa
Shizuka Bando
Akio Nozawa
Publikationsdatum
18.07.2018
Verlag
Springer Japan
Erschienen in
Artificial Life and Robotics / Ausgabe 3/2018
Print ISSN: 1433-5298
Elektronische ISSN: 1614-7456
DOI
https://doi.org/10.1007/s10015-018-0450-1

Weitere Artikel der Ausgabe 3/2018

Artificial Life and Robotics 3/2018 Zur Ausgabe

Neuer Inhalt