Contactless pressure measurement of an underwater shock wave in a microtube using a high-resolution background-oriented schlieren technique

verfasst von: Shota Yamamoto, Takaaki Shimazaki, Andrés Franco-Gómez, Sayaka Ichihara, Jingzu Yee, Yoshiyuki Tagawa

Erschienen in: Experiments in Fluids | Ausgabe 9/2022

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
download
DOWNLOAD
print
DRUCKEN
insite
SUCHEN
loading …

Abstract

A high-resolution background-oriented schlieren (BOS) technique, which utilizes a high-resolution camera and a microdot background pattern, is proposed and used to measure the pressure field of an underwater shock wave in a microtube. The propagation of the shock wave subsequently reaches a concave water–air interface set in the microtube resulting in the ejection of a focused microjet. This high spatial-resolution BOS technique can measure the pressure field of a shock front with a width as narrow as the order of only \(10^1\,\upmu\)m with a peak pressure as large as almost 3 MPa. This significant breakthrough has enabled the simultaneous measurement of the pressure impulse of the shock front and the velocity of the microjet tip. As a result, we have experimentally observed the linear relation between the velocity of the microjet tip and the pressure impulse of the shock front for the cases without secondary cavitation in the liquid bulk. Such relation was theoretically/numerically predicted by Peters et al. (J Fluid Mech 719:587–605, 2013). This study demonstrated the capability of the proposed high-resolution BOS technique as a microscale contactless pressure measurement tool for underwater shock waves and potentially other micro- and nanofluids.

Graphical abstract

Hinweise

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

1 Introduction

Underwater shock waves generated in a microtube are essential for the rapid transport of liquids in microfluidic devices. Typical examples include the generation of high-speed microjets for needle-free injection systems (Menezes et al. 2009). As predicted theoretically/numerically, the microjet velocity is strongly influenced by the pressure field in microfluidic devices (Peters et al. 2013; Tagawa et al. 2012). However, the use of contact measurement devices, such as needle-type hydrophones, causes distortion to the minute-scaled flow. To measure the pressure in microfluidic devices, we focused on the background-oriented schlieren (BOS) technique (Venkatakrishnan and Meier 2004), which is a contactless density measurement technique with a simple experimental setup (Hayasaka and Tagawa 2019). The BOS technique has been applied to measure the density field of a shock wave (Meier 2002; Yamamoto et al. 2015). The first successful pressure field measurement using the BOS technique was performed by Hayasaka et al. (2016). However, to measure the pressure field in microfluidic devices, the spatial resolution must be significantly high to accurately measure the distortion of the displacement field. In this letter, we apply the noninvasive BOS technique with a spatial resolution as high as \(0.68\,\upmu\)m/pixel. We then focus on the analysis between the pressure impulse and microjet velocity generated by the corresponding underwater shock waves. Note that the pressure impulse of the underwater shock wave is obtained by the integration of the pressure field in the shock front vicinity with respect to time.

2 Experimental methods

2.1 Experimental setup

A transparent square capillary tube of \(500\,\upmu\)m inner width, \(250\,\upmu\)m wall thickness, and 50 mm length is partially filled with ultra-pure water where a pulsed laser (Nd: YAG laser Nano S PIV, Litron 532 nm, 6 ns pulse) is focused through an objective lens (SLMPLN 20X, Olympus) to generate an underwater shock wave (see Fig. 1). In our experiments, the energy of a single pulse is varied from 0.36 to 0.97 mJ. The microdot background pattern (MEMS \(8\times 8\,\upmu\)m dot size) is attached to the wall of the capillary tube. High resolution images are captured using a CMOS camera (EOS Kiss X5, Canon, photographing resolution: 4000–6000 pixels) combined with a 105 mm focal length lens, two bellows, and several close-up rings, while being illuminated by an expanded laser beam of 640 nm (SI-LUX 640, Specialized Imaging Ltd.). The spatial resolution is set at \(0.68\,\upmu\)m/pixel, which has enabled us to measure the pressure field of a shock front of a width as narrow as the order of \(10^1\,\upmu\)m with a peak pressure as large as approximately 3 MPa. These are significantly narrower and larger, respectively, than the previous studies (Hayasaka et al. 2016; Yamamoto et al. 2015, i.e., 1 MPa.)
The microjet is captured with a high-speed camera at 50,000 fps (FASTCAM SA-X2, Photron) and illuminated using an expanded laser of 462 nm (CW Laser, IL-106B, HARDsoft). The shock wave laser, the high-resolution camera, the high-speed camera, and the light sources are triggered using a delay generator (Model 575, BNC). To avoid cross-illumination between the light sources, we install a high-pass filter on the high-resolution camera and a bandpass filter on the high-speed camera. An energy meter (EnergyMax-RS J0MB-HE, Coherent, USA, measurable range: 12 \(\upmu\)J-Hz) measuring the irradiation energy of the laser pulse using a half mirror (OptoSigma, transmittance: \(50\%\) up to 20 mJ) is assumed to be proportional to the energy absorbed by the irradiated water volume.

2.2 BOS analysis

As illustrated in Fig. 2, the BOS technique quantifies a density-gradient field of a target by comparing the background image distorted by the density gradient of the target and an undistorted background image. Venkatakrishnan and Meier (2004) showed that the displacement field of the distortion is proportional to the gradient of the refractive index. Therefore, it can be converted into the fluid density and then into the pressure distribution of the fluid. For this, the theory of the BOS technique was previously described in detail by Hayasaka et al. (2016).
The measurement accuracy of the underwater shock wave pressure is highly dependent on the spatial resolution of the BOS technique. The change in the local displacement as a function of position can be written as \(\sim \langle \partial v / \partial y\rangle \varDelta y\), where \(\varDelta y\) is the spatial resolution of the image. \(\langle \partial v / \partial y\rangle \varDelta y\) should be smaller than a certain threshold \(\delta v_{th}\). By comparing BOS and hydrophone measurements (Yamamoto et al. 2015; Shimazaki et al. 2022), we estimate that \(\delta v_{th}\le 0.4\). Therefore, to increase displacement field gradients (larger pressures), a smaller spatial resolution, such as \(\varDelta y\sim \delta v_{th}/\langle \partial v / \partial y\rangle\), is required.
Typical high-resolution BOS images of the backgrounds without the shockwave (undistorted) and with the shock wave (distorted) obtained with our system are presented in Fig. 3a and b, respectively. After the laser pulse was triggered (\(t = 0\,\upmu\)s), the image of each shock wave was taken at an interval of \(t= 0.5\,\upmu\)s. The displacement field shown in Fig. 3c is obtained by accurately registering (digital matching) the distorted and undistorted background images and computing the PIV cross-correlation (PIVlab, MATLAB2018), where the overall shape of the microshock wave is captured.
In this letter, we are interested in measuring the localized pressure at the shock front (indicated by the square region with black outline in Fig. 3c). The displacement field of the localized region of interest is averaged along the x-axis for noise reduction and the profile is shown in Fig. 3d. Along the z-axis, the profile is assumed to be constant to simplify the calculation. The density gradient is obtained by substituting the displacements v (\(\langle v\rangle _x \propto W \langle \partial \rho /\partial y \rangle _x\)) from Fig. 3d into the Gladstone-Dale equation ( Yamamoto et al. (2015)). We then obtained the fluid density by integrating the density gradient with respect to the undistorted area (hydrostatic density \(\rho _0=998\) kg/m\(^3\)), (\(\rho -\rho _0) \propto Z_D W \int \langle v\rangle _x\,dy\), where shock waves do not propagate (right of the shock front shown in Fig. 3c) (see Hayasaka et al. 2016). From the density, the pressure value is calculated through the Tait equation, \(\frac{p+T}{p_0+T}=\Bigl (\frac{\rho }{\rho _0}\Bigl )^\beta\), where \(p_0\) is the hydrostatic pressure, and T and \(\beta\) are constants with values of 314 MPa and 7, respectively. The spatial distribution of the pressure at the shockwave is shown in Fig. 3e. It is transformed into the temporal distribution shown in Figures 3(f) by assuming that the (unchanging) shock front is translating along the y-axis at the propagation speed of sound in water (1482 m/s at 20\(^{\circ }\)C). The pressure impulse of the shock wave is then obtained by integrating the temporal distribution, as illustrated in Fig. 3f.
The numerical simulations performed by Peters et al. (2013) have shown that the pressure impulse is proportional to the microjet velocity. Note that this simulation did not consider the effect of secondary cavitation in a liquid bulk, which might increase the jet velocity (Kiyama et al. 2016; Hayasaka et al. 2017).

3 Results and discussion

The shock wave in the microtube is successfully captured by the high-resolution BOS in all experiments, and an example of the results is shown in Fig. 3. As shown in Fig. 3e, the measured shock front is as narrow as approximately \(90\,\upmu\)m. The peak pressure of the shock front is almost as large as 3 MPa. This is approximately 3 times larger than Yamamoto et al. (2015).
Figure 4a presents an image sequence of the high-speed microjet generation. The air–water interface is deformed and evolves into a focused (conical) shape. The jet velocity as a function of time is shown in Fig. 4b where the jet reaches the maximum velocity of 13 m/s when the concave air-water interface converges at \(t=60\,\upmu\)s. As previously reported by Tagawa et al. (2012), the jet velocity decelerates due to surface tension and viscous effects, where the jet reaches an asymptotic speed of 9 m/s.
The jet velocity is plotted as a function of pressure impulse of the shock front in Fig. 5, where the opened and closed symbols indicate the cases without and with secondary cavitation (open markers in Fig. 5), respectively. Remarkably, for the cases without secondary cavitation, the pressure impulse of the shock wave increases linearly with the jet velocity, which is consistent with theoretical and numerical studies (Peters et al. 2013). Thus, the high-resolution BOS technique proposed in this study has successfully measured the shock pressure in a microtube with a correlation coefficient of 0.80 in comparison with an ideal linear model.
For the cases with secondary cavitation (closed markers in Fig. 5), the jet velocity is significantly higher than the fitted line, because the expansion waves attenuate due to the pressure relaxation around the cavitation bubbles (Kiyama et al. 2016; Yukisada et al. 2018; Hayasaka et al. 2017).

4 Conclusion

The BOS technique is applied to an underwater shock wave generated in a micrometric rectangular capillary tube. We have visualized and quantified the shock wave by using a microdot background pattern and a high-resolution camera. We configured our microscale BOS system with a resolution of \(0.68\,\upmu\)m/pixel allowing us to measure the pressure field of a shock front of a significantly narrow width and a significantly large peak pressure. The comparison of BOS pressure impulse values for the cases without cavitation and the corresponding microjet tip velocity revealed a linear relation. This is consistent with the theoretical predictions by Peters et al. (2013), which has validated the accuracy of our pressure impulse measurements. Thus, we confirmed that our BOS technique is a suitable tool for contactless measurements of underwater shock wave pressures of microscale and potentially for pressure fields in other micro- and nanofluids by increasing the spatial-temporal resolution.
Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://​creativecommons.​org/​licenses/​by/​4.​0/​.

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Literatur
Zurück zum Zitat Hayasaka K, Tagawa Y (2019) Mobile visualization of density fields using smartphone background-oriented schlieren. Exp Fluids 60(11):1–15CrossRef Hayasaka K, Tagawa Y (2019) Mobile visualization of density fields using smartphone background-oriented schlieren. Exp Fluids 60(11):1–15CrossRef
Zurück zum Zitat Hayasaka K, Tagawa Y, Liu T, Kameda M (2016) Optical-flow-based background-oriented schlieren technique for measuring a laser-induced underwater shock wave. Exp Fluids 57(12):1–11CrossRef Hayasaka K, Tagawa Y, Liu T, Kameda M (2016) Optical-flow-based background-oriented schlieren technique for measuring a laser-induced underwater shock wave. Exp Fluids 57(12):1–11CrossRef
Zurück zum Zitat Hayasaka K, Kiyama A, Tagawa Y (2017) Effects of pressure impulse and peak pressure of a shockwave on microjet velocity in a microchannel. Microfluid Nanofluid 21(11):166CrossRef Hayasaka K, Kiyama A, Tagawa Y (2017) Effects of pressure impulse and peak pressure of a shockwave on microjet velocity in a microchannel. Microfluid Nanofluid 21(11):166CrossRef
Zurück zum Zitat Kiyama A, Tagawa Y, Ando K, Kameda M (2016) Effects of a water hammer and cavitation on jet formation in a test tube. J Fluid Mech 787:224–236CrossRef Kiyama A, Tagawa Y, Ando K, Kameda M (2016) Effects of a water hammer and cavitation on jet formation in a test tube. J Fluid Mech 787:224–236CrossRef
Zurück zum Zitat Meier G (2002) Computerized background-oriented schlieren. Exp Fluids 33(1):181–187CrossRef Meier G (2002) Computerized background-oriented schlieren. Exp Fluids 33(1):181–187CrossRef
Zurück zum Zitat Menezes V, Kumar S, Takayama K (2009) Shock wave driven liquid microjets for drug delivery. J Appl Phys 106(8):086102–5CrossRef Menezes V, Kumar S, Takayama K (2009) Shock wave driven liquid microjets for drug delivery. J Appl Phys 106(8):086102–5CrossRef
Zurück zum Zitat Peters I et al (2013) Highly focused supersonic microjets: numerical simulations. J Fluid Mech 719:587–605CrossRefMATH Peters I et al (2013) Highly focused supersonic microjets: numerical simulations. J Fluid Mech 719:587–605CrossRefMATH
Zurück zum Zitat Shimazaki T, Ichihara S, Tagawa Y (2022) Background oriented schlieren technique with fast fourier demodulation for measuring large density-gradient fields of fluids. Exper Thermal Fluids Sci 134:110598CrossRef Shimazaki T, Ichihara S, Tagawa Y (2022) Background oriented schlieren technique with fast fourier demodulation for measuring large density-gradient fields of fluids. Exper Thermal Fluids Sci 134:110598CrossRef
Zurück zum Zitat Tagawa Y et al (2012) Highly focused supersonic microjets. Phys Rev X 2(3):031002 Tagawa Y et al (2012) Highly focused supersonic microjets. Phys Rev X 2(3):031002
Zurück zum Zitat Venkatakrishnan L, Meier G (2004) Density measurements using the background oriented schlieren technique. Exp Fluids 37(2):237–247CrossRef Venkatakrishnan L, Meier G (2004) Density measurements using the background oriented schlieren technique. Exp Fluids 37(2):237–247CrossRef
Zurück zum Zitat Yamamoto S, Tagawa Y, Kameda M (2015) Application of background-oriented schlieren (BOS) technique to a laser-induced underwater shock wave. Exp Fluids 56(5):93CrossRef Yamamoto S, Tagawa Y, Kameda M (2015) Application of background-oriented schlieren (BOS) technique to a laser-induced underwater shock wave. Exp Fluids 56(5):93CrossRef
Zurück zum Zitat Yukisada R, Kiyama A, Zhang X, Tagawa Y (2018) Enhancement of focused liquid jets by surface bubbles. Langmuir 34(14):4234–4240CrossRef Yukisada R, Kiyama A, Zhang X, Tagawa Y (2018) Enhancement of focused liquid jets by surface bubbles. Langmuir 34(14):4234–4240CrossRef
Metadaten
Titel
Contactless pressure measurement of an underwater shock wave in a microtube using a high-resolution background-oriented schlieren technique
verfasst von
Shota Yamamoto
Takaaki Shimazaki
Andrés Franco-Gómez
Sayaka Ichihara
Jingzu Yee
Yoshiyuki Tagawa
Publikationsdatum
01.09.2022
Verlag
Springer Berlin Heidelberg
Erschienen in
Experiments in Fluids / Ausgabe 9/2022
Print ISSN: 0723-4864
Elektronische ISSN: 1432-1114
DOI
https://doi.org/10.1007/s00348-022-03494-7

Weitere Artikel der Ausgabe 9/2022

Experiments in Fluids 9/2022 Zur Ausgabe

    Marktübersichten

    Die im Laufe eines Jahres in der „adhäsion“ veröffentlichten Marktübersichten helfen Anwendern verschiedenster Branchen, sich einen gezielten Überblick über Lieferantenangebote zu verschaffen.