Abstract

The surface electromyography (sEMG) has been used to characterize normal and abnormal behavior of the swallowing related muscles. One important activity in the analysis of the electromyographic recordings, is the detection of bursts, indicators of muscle activations but problematic in muscles with low signal-to-noise ratio (SNR). Most of methods for burst detection are based on amplitude measures which are signal-conditions dependent. We proposed a method to detect bursts based on the continuous wavelet transform and thresholding over the scalogram but not over amplitude. sEMG signals from 38 healthy subjects were recorded during swallowing tasks. We compared the proposed method to the visual method as a reference, and a previous method based on the Teager-Kaiser energy operator (TKEO). The proposed method avoids detection of false negatives better than TKEO, and it is suitable to apply in problems of burst detection in sEMG signals with low SNR.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Agostini, V., Knaflitz, M.: An algorithm for the estimation of the signal-to-noise ratio in surface myoelectric signals generated during cyclic movements. IEEE Trans. Biomed. Eng. 59(1), 219–225 (2012)CrossRef Agostini, V., Knaflitz, M.: An algorithm for the estimation of the signal-to-noise ratio in surface myoelectric signals generated during cyclic movements. IEEE Trans. Biomed. Eng. 59(1), 219–225 (2012)CrossRef
3.
Zurück zum Zitat Bonato, P., Alessio, T.D., Knaflitz, M.: A statistical method for the measurement of muscle activation intervals from surface myoelectric signal during gait. IEEE Trans. Biomed. Eng. 45(3), 287–299 (1998)CrossRef Bonato, P., Alessio, T.D., Knaflitz, M.: A statistical method for the measurement of muscle activation intervals from surface myoelectric signal during gait. IEEE Trans. Biomed. Eng. 45(3), 287–299 (1998)CrossRef
4.
Zurück zum Zitat Bonato, P., D’Alessio, T., Knaflitz, M.: A statistical method for the measurement of muscle activation intervals from surface myoelectric signal during gait. IEEE Trans. Biomed. Eng. 45(3), 287–299 (1998)CrossRef Bonato, P., D’Alessio, T., Knaflitz, M.: A statistical method for the measurement of muscle activation intervals from surface myoelectric signal during gait. IEEE Trans. Biomed. Eng. 45(3), 287–299 (1998)CrossRef
6.
Zurück zum Zitat De Luca, C.J.: The use of surface electromyography in biomechanics. J. Appl. Biomech. 13(2), 135–163 (1997)CrossRef De Luca, C.J.: The use of surface electromyography in biomechanics. J. Appl. Biomech. 13(2), 135–163 (1997)CrossRef
7.
Zurück zum Zitat Di Fabio, R.: Reliability of computerized surface electromyography for determining the onsent of muscle activity. Phys. Ther. 67(1), 43–48 (1987)CrossRef Di Fabio, R.: Reliability of computerized surface electromyography for determining the onsent of muscle activity. Phys. Ther. 67(1), 43–48 (1987)CrossRef
8.
Zurück zum Zitat Ertekin, C., Aydogdu, I.: Neurophysiology of swallowing. Clin. Neurophysiol. 114(12), 2226–2244 (2003)CrossRef Ertekin, C., Aydogdu, I.: Neurophysiology of swallowing. Clin. Neurophysiol. 114(12), 2226–2244 (2003)CrossRef
10.
Zurück zum Zitat Liu, J., Ying, D., Rymer, W.Z.: EMG burst presence probability: a joint time-frequency representation of muscle activity and its application to onset detection. J. Biomech. 48(6), 1193–1197 (2015)CrossRef Liu, J., Ying, D., Rymer, W.Z.: EMG burst presence probability: a joint time-frequency representation of muscle activity and its application to onset detection. J. Biomech. 48(6), 1193–1197 (2015)CrossRef
12.
Zurück zum Zitat Maria, P., et al.: Use of surface electromyography in phonation studies: an integrative review. Int. Arch. Otorhinolaryngol. 17(3), 329–339 (2013) Maria, P., et al.: Use of surface electromyography in phonation studies: an integrative review. Int. Arch. Otorhinolaryngol. 17(3), 329–339 (2013)
13.
Zurück zum Zitat Matsuo, K., et al.: Electromyography of swallowing with fine wire intramuscular electrodes in healthy human : activation sequence of selected hyoid muscles. Dysphagia 29(6), 713–721 (2014)CrossRef Matsuo, K., et al.: Electromyography of swallowing with fine wire intramuscular electrodes in healthy human : activation sequence of selected hyoid muscles. Dysphagia 29(6), 713–721 (2014)CrossRef
14.
Zurück zum Zitat Merlo, A., Farina, D., Merletti, R.: A fast and reliable technique for muscle activity detection from surface EMG signals. IEEE Trans. Biomed. Eng. 50(3), 316–323 (2003)CrossRef Merlo, A., Farina, D., Merletti, R.: A fast and reliable technique for muscle activity detection from surface EMG signals. IEEE Trans. Biomed. Eng. 50(3), 316–323 (2003)CrossRef
15.
Zurück zum Zitat Naseem, A., Jabloun, M., Buttelli, O., Ravier, P.: Detection of sEMG muscle activation intervals using gaussian mixture model and ant colony classifier. In: 2016 24th European Signal Processing Conference (EUSIPCO), pp. 1713–1717. IEEE (2016) Naseem, A., Jabloun, M., Buttelli, O., Ravier, P.: Detection of sEMG muscle activation intervals using gaussian mixture model and ant colony classifier. In: 2016 24th European Signal Processing Conference (EUSIPCO), pp. 1713–1717. IEEE (2016)
16.
Zurück zum Zitat Poorjavad, M.: Surface electromyographic assessment of swallowing function. Iran. J. Med. Sci. (2016) Poorjavad, M.: Surface electromyographic assessment of swallowing function. Iran. J. Med. Sci. (2016)
17.
Zurück zum Zitat Restrepo-Agudelo, S., Roldan-Vasco, S., Ramirez-Arbelaez, L., Cadavid-Arboleda, S., Perez-Giraldo, E., Orozco-Duque, A.: Improving surface EMG burst detection in infrahyoid muscles during swallowing using digital filters and discrete wavelet analysis. J. Electromyogr. Kinesiol. 35, 1–8 (2017)CrossRef Restrepo-Agudelo, S., Roldan-Vasco, S., Ramirez-Arbelaez, L., Cadavid-Arboleda, S., Perez-Giraldo, E., Orozco-Duque, A.: Improving surface EMG burst detection in infrahyoid muscles during swallowing using digital filters and discrete wavelet analysis. J. Electromyogr. Kinesiol. 35, 1–8 (2017)CrossRef
18.
Zurück zum Zitat Sampaio, M., Argolo, N., Melo, A., Nóbrega, A.C.: Wet voice as a sign of penetration/aspiration in Parkinsons disease: does testing material matter? Dysphagia 29(5), 610–615 (2014)CrossRef Sampaio, M., Argolo, N., Melo, A., Nóbrega, A.C.: Wet voice as a sign of penetration/aspiration in Parkinsons disease: does testing material matter? Dysphagia 29(5), 610–615 (2014)CrossRef
19.
Zurück zum Zitat Sasaki, M., et al.: Tongue interface based on surface EMG signals of suprahyoid muscles. ROBOMECH J. 3(1), 9 (2016)CrossRef Sasaki, M., et al.: Tongue interface based on surface EMG signals of suprahyoid muscles. ROBOMECH J. 3(1), 9 (2016)CrossRef
20.
Zurück zum Zitat Sejdić, E., Steele, C.M., Chau, T.: Classification of penetration-aspiration versus healthy swallows using dual-axis swallowing accelerometry signals in dysphagic subjects. IEEE Trans. Biomed. Eng. 60(7), 1859–1866 (2013)CrossRef Sejdić, E., Steele, C.M., Chau, T.: Classification of penetration-aspiration versus healthy swallows using dual-axis swallowing accelerometry signals in dysphagic subjects. IEEE Trans. Biomed. Eng. 60(7), 1859–1866 (2013)CrossRef
21.
Zurück zum Zitat Solnik, S., DeVita, P., Rider, P., Long, B., Hortobágyi, T.: Teager-Kaiser Operator improves the accuracy of EMG onset detection independent of signal-to-noise ratio. Acta Bioeng. Biomech./Wroclaw Univ. Technol. 10(2), 65 (2008) Solnik, S., DeVita, P., Rider, P., Long, B., Hortobágyi, T.: Teager-Kaiser Operator improves the accuracy of EMG onset detection independent of signal-to-noise ratio. Acta Bioeng. Biomech./Wroclaw Univ. Technol. 10(2), 65 (2008)
22.
Zurück zum Zitat Staude, G., Flachenecker, C., Daumer, M., Wolf, W.: Onset detection in surface electromyographic signals: a systematic comparison of methods. EURASIP J. Appl. Signal Process. 2001(1), 67–81 (2001)MATH Staude, G., Flachenecker, C., Daumer, M., Wolf, W.: Onset detection in surface electromyographic signals: a systematic comparison of methods. EURASIP J. Appl. Signal Process. 2001(1), 67–81 (2001)MATH
23.
Zurück zum Zitat Staude, G.H.: Precise onset detection of human motor responses using a whitening filter and the log-likelihood-ratio test. IEEE Trans. Biomed. Eng. 48(11), 1292–1305 (2001)CrossRef Staude, G.H.: Precise onset detection of human motor responses using a whitening filter and the log-likelihood-ratio test. IEEE Trans. Biomed. Eng. 48(11), 1292–1305 (2001)CrossRef
24.
Zurück zum Zitat Steele, C.M., et al.: The influence of food texture and liquid consistency modification on swallowing physiology and function: a systematic review. Dysphagia 30(1), 2–26 (2015)CrossRef Steele, C.M., et al.: The influence of food texture and liquid consistency modification on swallowing physiology and function: a systematic review. Dysphagia 30(1), 2–26 (2015)CrossRef
25.
Zurück zum Zitat Vannozzi, G., Conforto, S., D’Alessio, T.: Automatic detection of surface EMG activation timing using a wavelet transform based method. J. Electromyogr. Kinesiol. 20(4), 767–772 (2010)CrossRef Vannozzi, G., Conforto, S., D’Alessio, T.: Automatic detection of surface EMG activation timing using a wavelet transform based method. J. Electromyogr. Kinesiol. 20(4), 767–772 (2010)CrossRef
26.
Zurück zum Zitat Xu, Q., Quan, Y., Yang, L., He, J.: An adaptive algorithm for the determination of the onset and offset of muscle contraction by EMG signal processing. IEEE Trans. Neural Syst. Rehabil. Eng. 21(1), 65–73 (2013)CrossRef Xu, Q., Quan, Y., Yang, L., He, J.: An adaptive algorithm for the determination of the onset and offset of muscle contraction by EMG signal processing. IEEE Trans. Neural Syst. Rehabil. Eng. 21(1), 65–73 (2013)CrossRef
27.
Zurück zum Zitat Yang, D., Zhang, H., Gu, Y., Liu, H.: Accurate EMG onset detection in pathological, weak and noisy myoelectric signals. Biomed. Signal Process. Control 33, 306–315 (2017)CrossRef Yang, D., Zhang, H., Gu, Y., Liu, H.: Accurate EMG onset detection in pathological, weak and noisy myoelectric signals. Biomed. Signal Process. Control 33, 306–315 (2017)CrossRef
Metadaten
Titel
Continuous Wavelet Transform for Muscle Activity Detection in Surface EMG Signals During Swallowing
verfasst von
Sebastian Roldan-Vasco
Estefania Perez-Giraldo
Andres Orozco-Duque
Copyright-Jahr
2018
DOI
https://doi.org/10.1007/978-3-030-00353-1_22