Abstract

The FDA “Guidance for Industry” requires that all product contact surfaces inside the isolator before the start of each aseptic process are sterilized. Here is the method of choice the heat sterilization with steam (SIP). All plant parts or accessories which do not withstand the temperatures to be achieved for successful steam sterilisation, must be fumigated with a decontamination procedure, which makes the surfaces in the work area free of living organisms. It must be demonstrated a germ reduction of 6 log-levels with a suitable biological indicator.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Guidance for Industry: Sterile Drug Products Produced by Aseptic Processing—Current Good Manufacturing Practice. U.S. Department of Health and Human Services, Food and Drug Administration (FDA), 09-2004 (2004) Guidance for Industry: Sterile Drug Products Produced by Aseptic Processing—Current Good Manufacturing Practice. U.S. Department of Health and Human Services, Food and Drug Administration (FDA), 09-2004 (2004)
2.
Zurück zum Zitat Sigwarth, V., Moirandat, C.: Development and quantification of H2O2 decontamination cycles. PDA J. Pharm. Sci. Technol. 54(4), 286–304 (2000) Sigwarth, V., Moirandat, C.: Development and quantification of H2O2 decontamination cycles. PDA J. Pharm. Sci. Technol. 54(4), 286–304 (2000)
3.
Zurück zum Zitat Technische Regeln für Gefahrstoffe, Gemeinsames Ministerialblatt für Arbeit und Soziales, GMBI, Nr. 28, S. 605 Technische Regeln für Gefahrstoffe, Gemeinsames Ministerialblatt für Arbeit und Soziales, GMBI, Nr. 28, S. 605
4.
Zurück zum Zitat Vanhecke, V., Sigwarth, V., Moirandat, C.: A Potent and Safe H2O2 Fumigation Approach. PDA J. Pharm. Sci. Technol. 66(4) 354–370 (2012) Vanhecke, V., Sigwarth, V., Moirandat, C.: A Potent and Safe H2O2 Fumigation Approach. PDA J. Pharm. Sci. Technol. 66(4) 354–370 (2012)
Metadaten
Titel
Decontamination of Aseptically Operated Isolators
verfasst von
Hans-Jürgen Bässler
Frank Lehmann
Copyright-Jahr
2013
Verlag
Springer Berlin Heidelberg
DOI
https://doi.org/10.1007/978-3-642-39292-4_8