Skip to main content

2022 | OriginalPaper | Buchkapitel

6. Demand Side Equipment Control in Virtual Power Plant

verfasst von : Chuzo Ninagawa

Erschienen in: Virtual Power Plant System Integration Technology

Verlag: Springer Singapore

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Building multi-type air-conditioning is considered to be promising as a negawatt generation load of FastADR by power control among a number of power customer facilities. There are two reasons for this. First is the high penetration of building multi-type air-conditioning and the high power consumption. In general office buildings, in case of Japan, the power consumption of air-conditioning accounts for about 50% of the entire building, and in particular, building multi-type air-conditioning is installed in large quantities in small and medium-sized office buildings. Second, the equipment does not have a serious adverse effect on occupant compared to other consumer equipment (such as lighting).

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat E. Mangalova, E. Agfonov, Time series forecasting using ensamble of AR models with time-varying structure, in IEEE Conference on Evolving and Adaptive Intelligent Systems EAIS2012, pp. 198–203 (2012) E. Mangalova, E. Agfonov, Time series forecasting using ensamble of AR models with time-varying structure, in IEEE Conference on Evolving and Adaptive Intelligent Systems EAIS2012, pp. 198–203 (2012)
2.
Zurück zum Zitat Y. Iwata, K. Saito, C. Ninagawa, J. Morikawa, S. Kondo, Time series combined statistical modeling on dynamic response characteristics of ADR power curtailment for building facilities, in IEEJ Industry Applications Society Conference, pp. v265–v266 (2014) (in Japanese) Y. Iwata, K. Saito, C. Ninagawa, J. Morikawa, S. Kondo, Time series combined statistical modeling on dynamic response characteristics of ADR power curtailment for building facilities, in IEEJ Industry Applications Society Conference, pp. v265–v266 (2014) (in Japanese)
3.
Zurück zum Zitat T. Naramura, J. Morikawa, C. Ninagawa, Dynamic characteristics of side effect of room temperature in FastADR control of multi-type building air-conditioners facilities. IEEJ Power Energy Soc. Conf. (2015) (in Japanese) T. Naramura, J. Morikawa, C. Ninagawa, Dynamic characteristics of side effect of room temperature in FastADR control of multi-type building air-conditioners facilities. IEEJ Power Energy Soc. Conf. (2015) (in Japanese)
4.
Zurück zum Zitat S. Kondo, J. Morikawa, C. Ninagawa, Averaging effect of characteristics on FastADR power curtailment response of multi-type building air-conditioning facilities. IEEJ Power Energy Soc. Conf. (2015) (in Japanese) S. Kondo, J. Morikawa, C. Ninagawa, Averaging effect of characteristics on FastADR power curtailment response of multi-type building air-conditioning facilities. IEEJ Power Energy Soc. Conf. (2015) (in Japanese)
5.
Zurück zum Zitat T. Fukazawa, Y. Iwata, J. Morikawa, C. Ninagawa, Stabilization of neural network by combination with AR model in FastADR control of building air-conditioner facilities. IEEJ Trans. Elec. Electron. Eng. 11(1), 124–125 (2016) T. Fukazawa, Y. Iwata, J. Morikawa, C. Ninagawa, Stabilization of neural network by combination with AR model in FastADR control of building air-conditioner facilities. IEEJ Trans. Elec. Electron. Eng. 11(1), 124–125 (2016)
6.
Zurück zum Zitat T. Naramura, J. Morikawa, C. Ninagawa, Prediction model on room temperature side-effect due to FastADR aggregation for a cluster of building air-conditioning facilities. IEEJ Trans. Power Energy 136(4), 432–438 (2016) (in Japanese) T. Naramura, J. Morikawa, C. Ninagawa, Prediction model on room temperature side-effect due to FastADR aggregation for a cluster of building air-conditioning facilities. IEEJ Trans. Power Energy 136(4), 432–438 (2016) (in Japanese)
7.
Zurück zum Zitat S. Kondo, J. Morikawa, C. Ninagawa, Averaging effect on stochastic response prediction in FastADR aggregation for building air-conditioning facilities. IEEJ Trans. Electr. Electron. Eng. 11(6), 820–822 (2016) S. Kondo, J. Morikawa, C. Ninagawa, Averaging effect on stochastic response prediction in FastADR aggregation for building air-conditioning facilities. IEEJ Trans. Electr. Electron. Eng. 11(6), 820–822 (2016)
8.
Zurück zum Zitat Y. Nagata, T. Naramura, C. Ninagawa, J. Morikawa, Short time prediction model on room temperature side-effect due to fast demand response of building multi-type air-conditioning facilities power consumption. IEEJ Nat. Convention 4, 390–391 (2016). ((in Japanese)) Y. Nagata, T. Naramura, C. Ninagawa, J. Morikawa, Short time prediction model on room temperature side-effect due to fast demand response of building multi-type air-conditioning facilities power consumption. IEEJ Nat. Convention 4, 390–391 (2016). ((in Japanese))
9.
Zurück zum Zitat A. Nakamura, S. Kondo, C. Ninagawa, J. Morikawa, Time-series data mining for characteristics model on fast demand response of building multi-type air-conditioning facilities power consumption. IEEJ Nat. Convention 4, 392–393 (2016). ((in Japanese)) A. Nakamura, S. Kondo, C. Ninagawa, J. Morikawa, Time-series data mining for characteristics model on fast demand response of building multi-type air-conditioning facilities power consumption. IEEJ Nat. Convention 4, 392–393 (2016). ((in Japanese))
10.
Zurück zum Zitat K. Suzuki, C. Ninagawa, J. Morikawa, T. Inaba, S. Kondo, Estimation on averaging effect of large-scale aggregation of DR transient responses of building multi-type air-conditioning facilities. IEEJ Trans. Power Energy 138(7), 582–590 (2018) (in Japanese) K. Suzuki, C. Ninagawa, J. Morikawa, T. Inaba, S. Kondo, Estimation on averaging effect of large-scale aggregation of DR transient responses of building multi-type air-conditioning facilities. IEEJ Trans. Power Energy 138(7), 582–590 (2018) (in Japanese)
11.
Zurück zum Zitat A. Kiyota, M. Takahama, C. Ninagawa, Wide area network discrete feedback control on fast ADR of a cluster of building air-conditioning facilities. IEEJ Trans. Electr. Electron. Eng. 11(6), 826–828 (2015) A. Kiyota, M. Takahama, C. Ninagawa, Wide area network discrete feedback control on fast ADR of a cluster of building air-conditioning facilities. IEEJ Trans. Electr. Electron. Eng. 11(6), 826–828 (2015)
12.
Zurück zum Zitat H. Asaka, M. Takahama, C. Ninagawa, Mitigation of saturated LFC thermal power plants by very FastADR aggregation of a huge number of building multi-type air-conditioners. IEEJ Trans. Electr. Electron. Eng. 12(3), pp.442–443, 2017 H. Asaka, M. Takahama, C. Ninagawa, Mitigation of saturated LFC thermal power plants by very FastADR aggregation of a huge number of building multi-type air-conditioners. IEEJ Trans. Electr. Electron. Eng. 12(3), pp.442–443, 2017
13.
Zurück zum Zitat C. Ninagawa, H. Asaka, M. Takahama, Asymmetric constant-rate transfer function model for FastADR feedback control of cluster of building multi-type air-conditioners. IEEJ Trans. Power Energy 137(8), 566–572, 2017 (in Japanese) C. Ninagawa, H. Asaka, M. Takahama, Asymmetric constant-rate transfer function model for FastADR feedback control of cluster of building multi-type air-conditioners. IEEJ Trans. Power Energy 137(8), 566–572, 2017 (in Japanese)
14.
Zurück zum Zitat J. Morikawa, S. Kondo, S. Isozumi, C. Ninagawa, New fast demand control of building HVAC facilities for smart grid. Mitsubishi Heavy Indus. Tech. Rev. 51(2), 10–15 (2014) (in Japanese) J. Morikawa, S. Kondo, S. Isozumi, C. Ninagawa, New fast demand control of building HVAC facilities for smart grid. Mitsubishi Heavy Indus. Tech. Rev. 51(2), 10–15 (2014) (in Japanese)
15.
Zurück zum Zitat C. Ninagawa, Automated demand response aggregation and building energy management system. JSRE Annual Conf. D331 (2015) (in Japanese) C. Ninagawa, Automated demand response aggregation and building energy management system. JSRE Annual Conf. D331 (2015) (in Japanese)
Metadaten
Titel
Demand Side Equipment Control in Virtual Power Plant
verfasst von
Chuzo Ninagawa
Copyright-Jahr
2022
Verlag
Springer Singapore
DOI
https://doi.org/10.1007/978-981-16-6148-8_6

Neuer Inhalt