Skip to main content

2012 | OriginalPaper | Buchkapitel

208. Design of a Wearable Quantitative Muscle Rehabilitation Evaluation Robotic Hand Device

verfasst von : Xikai Tu, Liguo Yu, Jin He

Erschienen in: Electrical, Information Engineering and Mechatronics 2011

Verlag: Springer London

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

There is increasing interest in using robotic devices to assist in improving motor function for stroke patients. Rehabilitation evaluation during the motor rehabilitation process plays a crucial role in instructing robotic or manual therapy. Rehabilitation therapists can take some measure in assessing stiffness or motion range of the patient’s joints, but it is difficult for them to evaluate quantitatively and objectively. Furthermore few wearable robotic devices are reported for evaluating the recovery conditions of the patient’s hand internal muscles. The development of a pneumatic muscle (PM)-driven quantitative muscle rehabilitation evaluation robotic hand device serves this role. On account of the variance of the patient’s muscle recovery active forces and the complex nonlinear dynamics of PMs, the device becomes difficult to control. This paper presents a kind of feasible control strategy applied to this device.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Lo AC, Guarino PD et al (2010) Robot-assisted therapy for long-term upper-limb impairment after stroke. N Engl J Med 362(19):1772–1783CrossRef Lo AC, Guarino PD et al (2010) Robot-assisted therapy for long-term upper-limb impairment after stroke. N Engl J Med 362(19):1772–1783CrossRef
2.
Zurück zum Zitat Krebs H, Palazzolo J et al (2003) Rehabilitation robotics: performance-based progressive robot-assisted therapy. Auton Robots 15(1):7–20CrossRef Krebs H, Palazzolo J et al (2003) Rehabilitation robotics: performance-based progressive robot-assisted therapy. Auton Robots 15(1):7–20CrossRef
3.
Zurück zum Zitat Volpe BT, Lynch D et al (2008) Intensive sensorimotor arm training mediated by therapist or robot improves hemiparesis in patients with chronic stroke. Neurorehabil Neural Repair 22(3):305 Volpe BT, Lynch D et al (2008) Intensive sensorimotor arm training mediated by therapist or robot improves hemiparesis in patients with chronic stroke. Neurorehabil Neural Repair 22(3):305
4.
Zurück zum Zitat Zollo L, Rossini L et al (2011) Quantitative evaluation of upper-limb motor control in robot-aided rehabilitation. Med Biol Eng Comput 49:1131–1144CrossRef Zollo L, Rossini L et al (2011) Quantitative evaluation of upper-limb motor control in robot-aided rehabilitation. Med Biol Eng Comput 49:1131–1144CrossRef
5.
Zurück zum Zitat Pisano F, Miscio G et al (1996) Quantitative evaluation of normal muscle tone. J Neurol Sci 135(2):168–172CrossRef Pisano F, Miscio G et al (1996) Quantitative evaluation of normal muscle tone. J Neurol Sci 135(2):168–172CrossRef
6.
Zurück zum Zitat Colombo R, Pisano F et al (2005) Robotic techniques for upper limb evaluation and rehabilitation of stroke patients. IEEE Trans Neural Syst Rehabil Eng 13(3):311–324CrossRef Colombo R, Pisano F et al (2005) Robotic techniques for upper limb evaluation and rehabilitation of stroke patients. IEEE Trans Neural Syst Rehabil Eng 13(3):311–324CrossRef
7.
Zurück zum Zitat Ohata K, Tsuboyama T et al (2006) Measurement of muscle thickness as quantitative muscle evaluation for adults with severe cerebral palsy. Phys Ther 86(9):1231 Ohata K, Tsuboyama T et al (2006) Measurement of muscle thickness as quantitative muscle evaluation for adults with severe cerebral palsy. Phys Ther 86(9):1231
8.
Zurück zum Zitat Rijntjes M, Haevernick K et al (2009) Repeat therapy for chronic motor stroke: a pilot study for feasibility and efficacy. Neurorehabil Neural Repair 23(3):275 Rijntjes M, Haevernick K et al (2009) Repeat therapy for chronic motor stroke: a pilot study for feasibility and efficacy. Neurorehabil Neural Repair 23(3):275
9.
Zurück zum Zitat Timmermans AAA, Spooren AIF et al (2010) Influence of task-oriented training content on skilled arm-hand performance in stroke: a systematic review. Neurorehabil Neural Repair 24(9):858 Timmermans AAA, Spooren AIF et al (2010) Influence of task-oriented training content on skilled arm-hand performance in stroke: a systematic review. Neurorehabil Neural Repair 24(9):858
10.
Zurück zum Zitat Delp SL, Anderson FC et al (2007) OpenSim: open-source software to create and analyze dynamic simulations of movement. IEEE Trans Biomed Eng 54(11):1940–1950CrossRef Delp SL, Anderson FC et al (2007) OpenSim: open-source software to create and analyze dynamic simulations of movement. IEEE Trans Biomed Eng 54(11):1940–1950CrossRef
11.
Zurück zum Zitat Zajac FE (1989) Muscle and tendon: properties, models, scaling, and application to biomechanics and motor control. Critical Reviews Biomed Eng 17(4):359 Zajac FE (1989) Muscle and tendon: properties, models, scaling, and application to biomechanics and motor control. Critical Reviews Biomed Eng 17(4):359
Metadaten
Titel
Design of a Wearable Quantitative Muscle Rehabilitation Evaluation Robotic Hand Device
verfasst von
Xikai Tu
Liguo Yu
Jin He
Copyright-Jahr
2012
Verlag
Springer London
DOI
https://doi.org/10.1007/978-1-4471-2467-2_208

Neuer Inhalt