Skip to main content
Erschienen in: Cluster Computing 1/2018

09.02.2017

Development of radiation shield providing medical support for radioactive disaster in computer awareness analysis convergence-based

verfasst von: Seon-Chil Kim, Sun-Youl Seo, Ji-Hyun Yu, Sang-Deok Lee, Kwang-Hwan Kim, Chang-Gyu Kim

Erschienen in: Cluster Computing | Ausgabe 1/2018

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Experts expect that even though peaceful use of nuclear power including nuclear power plant is less likely to contribute to average annual radiation exposure level, once accidents occur, it will spell a disaster. This paper is to manufacture a bismuth eco-friendly radiation shield which does not contain lead for providing medical support when national disaster and radioactive accident occur and compare and evaluate the characteristics of the shield and the definition of image by using glass dosimeter and finally to assess its usability. The fact that bismuth radiation shield with 0.5 mm and lead radiation shield with 0.5 mm showed an equal percentage of efficiency is showing that bismuth is suitable as a eco-friendly material replacing lead in the field of medical radiation. This result implies that the eco-friendly radiation shield which is lighter than lead radiation shield can be utilized in the field of medical radiation as a radiation shield decreasing radiation exposure level. It is advised to develop a light weight and eco-friendly radiation shield to reduce radiation exposure level in the field of medical radiation and to obtain optimal medical image.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Lee, Y.S., Lee, J.W., Lee, Y.J.: Development of the rocess mapping for the radiation safety management. J. Radiat. Prot. 38(3), 149–156 (2013)CrossRef Lee, Y.S., Lee, J.W., Lee, Y.J.: Development of the rocess mapping for the radiation safety management. J. Radiat. Prot. 38(3), 149–156 (2013)CrossRef
2.
Zurück zum Zitat Kim, C.-G.: Spatial dose distribution and exposure dose during mammography. Indian J. Sci. Technol. 8(S8), 133–138 (2015)CrossRef Kim, C.-G.: Spatial dose distribution and exposure dose during mammography. Indian J. Sci. Technol. 8(S8), 133–138 (2015)CrossRef
3.
Zurück zum Zitat Nuclear, U.S.: Regulatory Commission. Final safety culture statement. NRC-2010-0282. Federal Register 76, 34773–34778 (2011) Nuclear, U.S.: Regulatory Commission. Final safety culture statement. NRC-2010-0282. Federal Register 76, 34773–34778 (2011)
4.
Zurück zum Zitat NCRP, Ionizing radiation exposures of the population of the United States, National Council on radiation protection and measurement, NCRP Publication 93, (1987) NCRP, Ionizing radiation exposures of the population of the United States, National Council on radiation protection and measurement, NCRP Publication 93, (1987)
5.
Zurück zum Zitat Jeon, M.-C., Han, M.-S., Lim, H.-S., Jang, J.-U., Yoo, S.-J., Seo, S.-Y., Kim, C.-G.: The analysis of doses and image at chest radiography using an active breathing coordinator (ABC) system. Clust. Comput. 18, 659–665 (2015)CrossRef Jeon, M.-C., Han, M.-S., Lim, H.-S., Jang, J.-U., Yoo, S.-J., Seo, S.-Y., Kim, C.-G.: The analysis of doses and image at chest radiography using an active breathing coordinator (ABC) system. Clust. Comput. 18, 659–665 (2015)CrossRef
6.
Zurück zum Zitat Seo, D., Jung, H., Sung, W.-K., Kim, S., Lee, S.: Development of Korean spine database and ontology for realizing \(e\)-Spine. Clust. Comput. 17, 1069–1080 (2014)CrossRef Seo, D., Jung, H., Sung, W.-K., Kim, S., Lee, S.: Development of Korean spine database and ontology for realizing \(e\)-Spine. Clust. Comput. 17, 1069–1080 (2014)CrossRef
7.
Zurück zum Zitat Kim, C.-G.: The development of bismuth shielding to protect the thyroid gland in radiations environment. Indian J. Sci. Technol. 9(25), 1–6 (2016) Kim, C.-G.: The development of bismuth shielding to protect the thyroid gland in radiations environment. Indian J. Sci. Technol. 9(25), 1–6 (2016)
8.
Zurück zum Zitat Suero, E.M., Hawi, N., Citak, M., Decker, S., Brandes, J., Meller, R., Krettek, C., Stübig, T.: Intraoperative imaging of the shoulder: a comparison of two- and three-dimensional imaging techniques. Technol. Health Care 23(2), 171–177 (2015) Suero, E.M., Hawi, N., Citak, M., Decker, S., Brandes, J., Meller, R., Krettek, C., Stübig, T.: Intraoperative imaging of the shoulder: a comparison of two- and three-dimensional imaging techniques. Technol. Health Care 23(2), 171–177 (2015)
9.
Zurück zum Zitat Kim, C.-G.: Exposure dose reduction during lateral spine test with water filter. Technol. Health Care 24, 429–438 (2016)CrossRef Kim, C.-G.: Exposure dose reduction during lateral spine test with water filter. Technol. Health Care 24, 429–438 (2016)CrossRef
10.
Zurück zum Zitat Marina, M., Dragan, J., Aleksandar, P.: Segmentation for the enhancement of microcalcifications in digital mammograms. Technol. Health Care 22(5), 701–715 (2014) Marina, M., Dragan, J., Aleksandar, P.: Segmentation for the enhancement of microcalcifications in digital mammograms. Technol. Health Care 22(5), 701–715 (2014)
11.
Zurück zum Zitat Youn-Soo, S., Ah-Hyeon, K., Ja-Eun, C., So-Youn, A.: Use of three-dimensional computed tomography images in dental care of children and adolescents in Korea. Technol. Health Care 22(3), 333–337 (2014) Youn-Soo, S., Ah-Hyeon, K., Ja-Eun, C., So-Youn, A.: Use of three-dimensional computed tomography images in dental care of children and adolescents in Korea. Technol. Health Care 22(3), 333–337 (2014)
12.
Zurück zum Zitat Sang-Tae, K., Jung-Keun, C.: Monte Carlo simulation for correlation analysis of average glandular dose by breast thickness and glandular ratio in breast tissue. Technol. Health Care 22(3), 345–350 (2014) Sang-Tae, K., Jung-Keun, C.: Monte Carlo simulation for correlation analysis of average glandular dose by breast thickness and glandular ratio in breast tissue. Technol. Health Care 22(3), 345–350 (2014)
13.
Zurück zum Zitat Young-Cheol, J., Chung-Hwan, L., Chun-Yong, L., Hong-Ryang, J.: A study on the correlation between patients’physical characteristics and effective dose of liver computed tomography. Technol. Health Care 22(3), 403–408 (2014) Young-Cheol, J., Chung-Hwan, L., Chun-Yong, L., Hong-Ryang, J.: A study on the correlation between patients’physical characteristics and effective dose of liver computed tomography. Technol. Health Care 22(3), 403–408 (2014)
14.
Zurück zum Zitat Jung, E.-Y., Kim, J., Chung, K.-Y., Kyun Park, D.: Mobile healthcare application with EMR interoperability for diabetes patients. Clust. Comput. 17, 871–880 (2014)CrossRef Jung, E.-Y., Kim, J., Chung, K.-Y., Kyun Park, D.: Mobile healthcare application with EMR interoperability for diabetes patients. Clust. Comput. 17, 871–880 (2014)CrossRef
15.
Zurück zum Zitat Song, X., He, G., Zhang, Z., Long, T., Peng, Y., Wang, Z.: Visual attention model based mining area recognition on massive high-resolution remote sensing images. Clust. Comput. 18, 541–548 (2015)CrossRef Song, X., He, G., Zhang, Z., Long, T., Peng, Y., Wang, Z.: Visual attention model based mining area recognition on massive high-resolution remote sensing images. Clust. Comput. 18, 541–548 (2015)CrossRef
16.
Zurück zum Zitat Kim, J.-K., Lee, J.-S., Park, D.-K., Lim, Y.-S., Lee, Y.-H., Jung, E.-Y.: Adaptive mining prediction model for content recommendation to coronary heart disease patients. Clust. Comput. 17, 881–891 (2014)CrossRef Kim, J.-K., Lee, J.-S., Park, D.-K., Lim, Y.-S., Lee, Y.-H., Jung, E.-Y.: Adaptive mining prediction model for content recommendation to coronary heart disease patients. Clust. Comput. 17, 881–891 (2014)CrossRef
17.
Zurück zum Zitat S. C. Kim, M. H. Park, Development of radiation shielding sheet with environmentally-friendly materials; II: Evaluation of Barum, Tourmaline, silicon polymers in the radiation shielding sheet, J. Radiol. Sci. Vol. 34, No. 2, (2011) S. C. Kim, M. H. Park, Development of radiation shielding sheet with environmentally-friendly materials; II: Evaluation of Barum, Tourmaline, silicon polymers in the radiation shielding sheet, J. Radiol. Sci. Vol. 34, No. 2, (2011)
18.
Zurück zum Zitat Kim, S.H., Kim, Y.J., Kwak, J.S.: Development and radiation shield effects of dose reduction fiber for scatter ray in CT exams. J. Korea Acad. Indus. Cooperation Soc. 14(4), 1871–1876 (2013)CrossRef Kim, S.H., Kim, Y.J., Kwak, J.S.: Development and radiation shield effects of dose reduction fiber for scatter ray in CT exams. J. Korea Acad. Indus. Cooperation Soc. 14(4), 1871–1876 (2013)CrossRef
19.
Zurück zum Zitat Lee, H.L., Kim, H.Y., Choi, H.W., Lee, H.M., Lim, C.S.: The effects of a thyroid shield made of a tissue-equivalent material on the reduction of the thyroid exposure dose in panoramic radiography. J. Korea Acad. Indus. Cooperation Soc. 13(5), 2278–2284 (2012)CrossRef Lee, H.L., Kim, H.Y., Choi, H.W., Lee, H.M., Lim, C.S.: The effects of a thyroid shield made of a tissue-equivalent material on the reduction of the thyroid exposure dose in panoramic radiography. J. Korea Acad. Indus. Cooperation Soc. 13(5), 2278–2284 (2012)CrossRef
20.
Zurück zum Zitat Farzaneh, M.J.K., Shirin Shandiz, M., Vardian, M., Reza Deevband, M., Reza Kardan, M.: Evaluation of image quality and patient dose in conventional radiography examinations in radiology centers in sistan and baluchestan, Iran and comparing with that of international guidelines levels. Indian J. Sci. Technol. 4(11), 1429–1433 (2011) Farzaneh, M.J.K., Shirin Shandiz, M., Vardian, M., Reza Deevband, M., Reza Kardan, M.: Evaluation of image quality and patient dose in conventional radiography examinations in radiology centers in sistan and baluchestan, Iran and comparing with that of international guidelines levels. Indian J. Sci. Technol. 4(11), 1429–1433 (2011)
21.
Zurück zum Zitat Jung, M., Kweon, D., Kwon, S.: Effectiveness of bismuth shield to reduce eye lens radiation dose using the photoluminescence dosimetry in computed tomography. Radiotechnol. Sci. 32(3), 307–312 (2009) Jung, M., Kweon, D., Kwon, S.: Effectiveness of bismuth shield to reduce eye lens radiation dose using the photoluminescence dosimetry in computed tomography. Radiotechnol. Sci. 32(3), 307–312 (2009)
22.
Zurück zum Zitat Rah, J.-E., Hong, J.-Y., Kim, G.-Y., Kim, Y.-L., Shin, D.-O., Suh, T.-S.: A comparison of the dosimetric characteristics of a glass rod dosimeter and a themoluminescent dosimeter for mailed dosimeter. Radiat. Meas. 44, 18–23 (2009)CrossRef Rah, J.-E., Hong, J.-Y., Kim, G.-Y., Kim, Y.-L., Shin, D.-O., Suh, T.-S.: A comparison of the dosimetric characteristics of a glass rod dosimeter and a themoluminescent dosimeter for mailed dosimeter. Radiat. Meas. 44, 18–23 (2009)CrossRef
23.
Zurück zum Zitat Lee, H.L., Kim, H.Y., Choi, H.W., Lee, H.M., Lim, C.S.: The effects of a thyroid shield made of a tissue-equivalent material on the reduction of the thyroid exposure dose in panoramic radiography. J. Korea Acad. Indus. Cooperation Soc. 13(5), 2278–2284 (2012)CrossRef Lee, H.L., Kim, H.Y., Choi, H.W., Lee, H.M., Lim, C.S.: The effects of a thyroid shield made of a tissue-equivalent material on the reduction of the thyroid exposure dose in panoramic radiography. J. Korea Acad. Indus. Cooperation Soc. 13(5), 2278–2284 (2012)CrossRef
24.
Zurück zum Zitat Kim, C.G.: Exposure dose reduction using Pb banding of own manufacturing. Soc. Dig. Policy Manag. 11(6), 269–273 (2013) Kim, C.G.: Exposure dose reduction using Pb banding of own manufacturing. Soc. Dig. Policy Manag. 11(6), 269–273 (2013)
25.
Zurück zum Zitat Kim, C.G.: Radiation dose reduction effectiveness of a male gonadal shield during 128-MDCT using glass detector. Soc. Dig. Policy Manag. 11(7), 237–242 (2013) Kim, C.G.: Radiation dose reduction effectiveness of a male gonadal shield during 128-MDCT using glass detector. Soc. Dig. Policy Manag. 11(7), 237–242 (2013)
26.
Zurück zum Zitat Kim, C.G.: Measurement dose of dental panoramagraphy using a radiophotoluminescent glass rod detector. Korea Acad. Indus. Cooperation J. 12(6), 2624–2628 (2011)MathSciNetCrossRef Kim, C.G.: Measurement dose of dental panoramagraphy using a radiophotoluminescent glass rod detector. Korea Acad. Indus. Cooperation J. 12(6), 2624–2628 (2011)MathSciNetCrossRef
27.
Zurück zum Zitat Jeong eun Ra: W.S Suh, D.O. Shin, H. S. Kim, T. S. Suh, Determination of out factors for the gamma-knife using a photoluminescence glass rod detector. Med. Phys. 18(1), 198–199 (2007) Jeong eun Ra: W.S Suh, D.O. Shin, H. S. Kim, T. S. Suh, Determination of out factors for the gamma-knife using a photoluminescence glass rod detector. Med. Phys. 18(1), 198–199 (2007)
28.
Zurück zum Zitat Kim, C.G.: Zirconia core inspection during radiation dose and image quality”. J. Converg. Inf. Technol. 8(13), 471–475 (2013) Kim, C.G.: Zirconia core inspection during radiation dose and image quality”. J. Converg. Inf. Technol. 8(13), 471–475 (2013)
29.
Zurück zum Zitat Kang, J.-M., Lim, H., Yun, S.: A study for the mechanism of expression of individual creativity throughout the social learning platform in cluster computing environment (focus on scenario and data collection design). Clust. Comput. 18, 619–627 (2015)CrossRef Kang, J.-M., Lim, H., Yun, S.: A study for the mechanism of expression of individual creativity throughout the social learning platform in cluster computing environment (focus on scenario and data collection design). Clust. Comput. 18, 619–627 (2015)CrossRef
30.
Zurück zum Zitat Barzegar, B., Esmaeelzadeh, H., Shirgahi, H.: A new method on resource management in grid computing systems based on QoS and semantics. Indian J. Sci. Technol. 4(11), 1416–1419 (2011) Barzegar, B., Esmaeelzadeh, H., Shirgahi, H.: A new method on resource management in grid computing systems based on QoS and semantics. Indian J. Sci. Technol. 4(11), 1416–1419 (2011)
31.
Zurück zum Zitat Lee, H.L., Kim, H.Y., Choi, H.W., Lee, H.M., Lim, C.S.: The effects of a thyroid shield made of a tissue-equivalent material on the reduction of the thyroid exposure dose in panoramic radiography. J. Korea Acad. Indus. Cooperation Soc. 13(5), 2278–2284 (2012)CrossRef Lee, H.L., Kim, H.Y., Choi, H.W., Lee, H.M., Lim, C.S.: The effects of a thyroid shield made of a tissue-equivalent material on the reduction of the thyroid exposure dose in panoramic radiography. J. Korea Acad. Indus. Cooperation Soc. 13(5), 2278–2284 (2012)CrossRef
32.
Zurück zum Zitat Kim, C.G.: The evaluation of the radiation dose and the image quality during MDCT using glass rod detector. Korea Soc. Dig. Policy and Manag. J. 10(2), 249–254 (2012) Kim, C.G.: The evaluation of the radiation dose and the image quality during MDCT using glass rod detector. Korea Soc. Dig. Policy and Manag. J. 10(2), 249–254 (2012)
33.
Zurück zum Zitat Chan-Soo, P., Jong-Il, P., Kwang-Gi, K., Chang-No, C., Byung-Uk, A., Hwan-Jun, J.: Select this result for bulk action a quantitative evaluation of abdominal aorta aneurysm by CT images. Technol. Health Care 23(1), 37–45 (2015) Chan-Soo, P., Jong-Il, P., Kwang-Gi, K., Chang-No, C., Byung-Uk, A., Hwan-Jun, J.: Select this result for bulk action a quantitative evaluation of abdominal aorta aneurysm by CT images. Technol. Health Care 23(1), 37–45 (2015)
34.
Zurück zum Zitat Yuexing, N., Haifeng, C., Jinyin, Y., Ning, L.: CT-guided satellite ganglion block for the treatment of prostatectomy pain in survivors of breast cancer. Technol. Health Care 23, 133–139 (2015)CrossRef Yuexing, N., Haifeng, C., Jinyin, Y., Ning, L.: CT-guided satellite ganglion block for the treatment of prostatectomy pain in survivors of breast cancer. Technol. Health Care 23, 133–139 (2015)CrossRef
35.
Zurück zum Zitat Youl-Hun, S.: Evaluation of relative speed of latent images in relation to changes in fading time and storage temperature of imaging plates in computed radiography systems. Technol. Health Care 22(3), 427–434 (2014) Youl-Hun, S.: Evaluation of relative speed of latent images in relation to changes in fading time and storage temperature of imaging plates in computed radiography systems. Technol. Health Care 22(3), 427–434 (2014)
Metadaten
Titel
Development of radiation shield providing medical support for radioactive disaster in computer awareness analysis convergence-based
verfasst von
Seon-Chil Kim
Sun-Youl Seo
Ji-Hyun Yu
Sang-Deok Lee
Kwang-Hwan Kim
Chang-Gyu Kim
Publikationsdatum
09.02.2017
Verlag
Springer US
Erschienen in
Cluster Computing / Ausgabe 1/2018
Print ISSN: 1386-7857
Elektronische ISSN: 1573-7543
DOI
https://doi.org/10.1007/s10586-017-0750-6

Weitere Artikel der Ausgabe 1/2018

Cluster Computing 1/2018 Zur Ausgabe