Prosthesis bearings are precision mechanical systems from which performance improvement represents a direct contribution to patient’s wellbeing. Spherical shape of hip prosthesis bearing approaches natural ones, but their performance become degraded in service, and the lubrication and wear mechanisms are outstanding fields of research. Because tribological phenomena are complex, attempts of modelling the bearing requires precise consideration of the boundary conditions that the real prosthesis have. Detailed experimental characterization of two ceramic hip prostheses is accomplished. Shape and roughness are measured by accurate point coordinate metrology with proper methodology through contact probing by a coordinate measuring machine, and optical measuring through confocal microscopy. The results quantify the deviation from the ideal shape and significant roughness parameters of bearing surfaces. Their influence is discussed in the spotlight of their relationship with the tribological behavior of the prosthesis. Future works direction are envisioned so geometrical boundary conditions can play an important role in prosthesis performance understanding and improvement.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Affatato, S., Ruggiero, A., Merola, M.: Advanced biomaterials in hip joint arthroplasty. A review on polymer and ceramics composites as alternative bearings. Compos. Part B 83, 276–283 (2015)CrossRef Affatato, S., Ruggiero, A., Merola, M.: Advanced biomaterials in hip joint arthroplasty. A review on polymer and ceramics composites as alternative bearings. Compos. Part B 83, 276–283 (2015)CrossRef
2.
Zurück zum Zitat Ruggiero, A., D׳Amato, R., Gómez, E., Merola, M.: Experimental comparison on tribological pairs UHMWPE/TIAL6V4 alloy, UHMWPE/AISI316L austenitic stainless and UHMWPE/AL2O3 ceramic, under dry and lubricated conditions. Tribol. Int. 96, 349–360 (2016)CrossRef Ruggiero, A., D׳Amato, R., Gómez, E., Merola, M.: Experimental comparison on tribological pairs UHMWPE/TIAL6V4 alloy, UHMWPE/AISI316L austenitic stainless and UHMWPE/AL2O3 ceramic, under dry and lubricated conditions. Tribol. Int. 96, 349–360 (2016)CrossRef
3.
Zurück zum Zitat Kurth, M., Eyerer, P., Ascherl, R., Dittel, K., Holz, U.: An evaluation of retrieved UHMWPE hip joint cups. J. Biomater. Appl. 3(1), 33–51 (1988)CrossRef Kurth, M., Eyerer, P., Ascherl, R., Dittel, K., Holz, U.: An evaluation of retrieved UHMWPE hip joint cups. J. Biomater. Appl. 3(1), 33–51 (1988)CrossRef
4.
Zurück zum Zitat Rieger, W.: Ceramics in orthopedics–30 years of evolution and experience. In: World Tribology Forum in Arthroplasty, pp. 283–294 (2001) Rieger, W.: Ceramics in orthopedics–30 years of evolution and experience. In: World Tribology Forum in Arthroplasty, pp. 283–294 (2001)
5.
Zurück zum Zitat Visuri, T., Pukkala, E.: Does Metal-on-Metal Total Hip Prosthesis Have Influence on Cancer? A Long-term Follow-up Study, in World Tribology Forum in Arthroplasty, pp. 181–188. Hans Huber, Seattle (2001) Visuri, T., Pukkala, E.: Does Metal-on-Metal Total Hip Prosthesis Have Influence on Cancer? A Long-term Follow-up Study, in World Tribology Forum in Arthroplasty, pp. 181–188. Hans Huber, Seattle (2001)
6.
Zurück zum Zitat Ruggiero, A., Gómez, E., D’Amato, R.: Approximate closed-form solution of the synovial fluid film force in the human ankle joint with non-Newtonian lubricant. Tribol. Int. 57, 156–161 (2013)CrossRef Ruggiero, A., Gómez, E., D’Amato, R.: Approximate closed-form solution of the synovial fluid film force in the human ankle joint with non-Newtonian lubricant. Tribol. Int. 57, 156–161 (2013)CrossRef
7.
Zurück zum Zitat Ruggiero, A., Gòmez, E., D’Amato, R.: Approximate analytical model for the squeeze-film lubrication of the human ankle joint with synovial fluid filtrated by articular cartilage. Tribol. Lett. 41(2), 337–343 (2011)CrossRef Ruggiero, A., Gòmez, E., D’Amato, R.: Approximate analytical model for the squeeze-film lubrication of the human ankle joint with synovial fluid filtrated by articular cartilage. Tribol. Lett. 41(2), 337–343 (2011)CrossRef
8.
Zurück zum Zitat Ruggiero, A., D’Amato, R., Gómez, E.: Experimental analysis of tribological behavior of UHMWPE against AISI420C and against TiAl6V4 alloy under dry and lubricated conditions. Tribol. Int. 92, 154–161 (2015)CrossRef Ruggiero, A., D’Amato, R., Gómez, E.: Experimental analysis of tribological behavior of UHMWPE against AISI420C and against TiAl6V4 alloy under dry and lubricated conditions. Tribol. Int. 92, 154–161 (2015)CrossRef
9.
Zurück zum Zitat Affatato, S., Ruggiero, A., De Mattia, J.S., Taddei, P.: Does metal transfer affect the tribological behaviour of femoral heads? Roughness and phase transformation analyses on retrieved zirconia and Biolox® Delta composites. Compos. Part B Eng. 92, 290–298 (2016)CrossRef Affatato, S., Ruggiero, A., De Mattia, J.S., Taddei, P.: Does metal transfer affect the tribological behaviour of femoral heads? Roughness and phase transformation analyses on retrieved zirconia and Biolox® Delta composites. Compos. Part B Eng. 92, 290–298 (2016)CrossRef
10.
Zurück zum Zitat Ruggiero, A., Merola, M., Affatato, S.: Finite element simulations of hard-on-soft hip joint prosthesis accounting for dynamic loads calculated from a musculoskeletal model during walking. Materials (Basel) 11(4), 574 (2018)CrossRef Ruggiero, A., Merola, M., Affatato, S.: Finite element simulations of hard-on-soft hip joint prosthesis accounting for dynamic loads calculated from a musculoskeletal model during walking. Materials (Basel) 11(4), 574 (2018)CrossRef
11.
Zurück zum Zitat D’Amato, R., Calvo, R., Gó Mez, E.: Sensitivity study of the morphometric fitting on the pressure field inside ankle joints. Case Stud. Mech. Syst. Signal Process. 1, 8–14 (2015) D’Amato, R., Calvo, R., Gó Mez, E.: Sensitivity study of the morphometric fitting on the pressure field inside ankle joints. Case Stud. Mech. Syst. Signal Process. 1, 8–14 (2015)
12.
Zurück zum Zitat Ruggiero, A., Affatato, S., Merola, M., De, M.C.: FEM analysis of metal on UHMWPE total hip prosthesis during normal walking cycle. In: Proceedings of the XXIII Conference of the Italian Association of Theoretical and Applied Mechanics (AIMETA 2017), pp. 4–7 (2017) Ruggiero, A., Affatato, S., Merola, M., De, M.C.: FEM analysis of metal on UHMWPE total hip prosthesis during normal walking cycle. In: Proceedings of the XXIII Conference of the Italian Association of Theoretical and Applied Mechanics (AIMETA 2017), pp. 4–7 (2017)
13.
Zurück zum Zitat Ruggiero, A., Merola, M., Affatato, S.: On the biotribology of total knee replacement: a new roughness measurements protocol on in vivo condyles considering the dynamic loading from musculoskeletal multibody model. Measurement 112, 22–28 (2017)CrossRef Ruggiero, A., Merola, M., Affatato, S.: On the biotribology of total knee replacement: a new roughness measurements protocol on in vivo condyles considering the dynamic loading from musculoskeletal multibody model. Measurement 112, 22–28 (2017)CrossRef
14.
Zurück zum Zitat Calvo, R., D’Amato, R., Gómez, E., Domingo, R.: Integration of error compensation of coordinate measuring machines into feature measurement: Part II—experimental implementation. Sensors 16(10), 1705 (2016)CrossRef Calvo, R., D’Amato, R., Gómez, E., Domingo, R.: Integration of error compensation of coordinate measuring machines into feature measurement: Part II—experimental implementation. Sensors 16(10), 1705 (2016)CrossRef
15.
Zurück zum Zitat Laurian, T., Tudor, A.: Tribological influence the clearance in the hip prosthesis. In: 8th International Tribology Conference, 8–10, Belgrade, Serbia, pp. 65–70 (2003) Laurian, T., Tudor, A.: Tribological influence the clearance in the hip prosthesis. In: 8th International Tribology Conference, 8–10, Belgrade, Serbia, pp. 65–70 (2003)
16.
Zurück zum Zitat Dowson, D., McNie, C.M., Goldsmith, A.A.J.: Direct experimental evidence of lubrication in a metal-on-metal total hip replacement tested in a joint simulator. Proc. Inst. Mech. Eng. Part C J. Mech. Eng. Sci. 214(1), 75–86 (2000)CrossRef Dowson, D., McNie, C.M., Goldsmith, A.A.J.: Direct experimental evidence of lubrication in a metal-on-metal total hip replacement tested in a joint simulator. Proc. Inst. Mech. Eng. Part C J. Mech. Eng. Sci. 214(1), 75–86 (2000)CrossRef
17.
Zurück zum Zitat Timsit, R.S.: Electrical contacts resistance: fundamental principles. In: Slade, P.G. (ed.) Electrical Contacts: Principles and Applications, p. 1104. Marcel Dekker, Inc, New York (1999) Timsit, R.S.: Electrical contacts resistance: fundamental principles. In: Slade, P.G. (ed.) Electrical Contacts: Principles and Applications, p. 1104. Marcel Dekker, Inc, New York (1999)
18.
Zurück zum Zitat Greenwood, J.A., Tripp, J.H.: The contact of two nominally flat rough surfaces. Proc. Inst. Mech. Eng. 185(1), 625–633 (1970)CrossRef Greenwood, J.A., Tripp, J.H.: The contact of two nominally flat rough surfaces. Proc. Inst. Mech. Eng. 185(1), 625–633 (1970)CrossRef
19.
Zurück zum Zitat Blunt, L., Thomas, T.R.: Wear ranking of hard on hard bearings for prosthetic hip joints. Wear 257(12), 1208–1212 (2004)CrossRef Blunt, L., Thomas, T.R.: Wear ranking of hard on hard bearings for prosthetic hip joints. Wear 257(12), 1208–1212 (2004)CrossRef
Metadaten
Titel
Dimensional Characterization of Prosthesis Bearings for Tribological Modelling
verfasst von
Roberto D’Amato
Roque Calvo
Massimiliano Merola
Petr Valášek
Miroslav Müller
Copyright-Jahr
2019
DOI
https://doi.org/10.1007/978-3-319-99353-9_21

    Marktübersichten

    Die im Laufe eines Jahres in der „adhäsion“ veröffentlichten Marktübersichten helfen Anwendern verschiedenster Branchen, sich einen gezielten Überblick über Lieferantenangebote zu verschaffen.