Direct Estimation of Pharmacokinetic Parameters from DCE-MRI Using Deep CNN with Forward Physical Model Loss

verfasst von : Cagdas Ulas, Giles Tetteh, Michael J. Thrippleton, Paul A. Armitage, Stephen D. Makin, Joanna M. Wardlaw, Mike E. Davies, Bjoern H. Menze

Erschienen in: Medical Image Computing and Computer Assisted Intervention – MICCAI 2018

Verlag: Springer International Publishing

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Dynamic contrast-enhanced (DCE) MRI is an evolving imaging technique that provides a quantitative measure of pharmacokinetic (PK) parameters in body tissues, in which series of \(T_1\)-weighted images are collected following the administration of a paramagnetic contrast agent. Unfortunately, in many applications, conventional clinical DCE-MRI suffers from low spatiotemporal resolution and insufficient volume coverage. In this paper, we propose a novel deep learning based approach to directly estimate the PK parameters from undersampled DCE-MRI data. Specifically, we design a custom loss function where we incorporate a forward physical model that relates the PK parameters to corrupted image-time series obtained due to subsampling in k-space. This allows the network to directly exploit the knowledge of true contrast agent kinetics in the training phase, and hence provide more accurate restoration of PK parameters. Experiments on clinical brain DCE datasets demonstrate the efficacy of our approach in terms of fidelity of PK parameter reconstruction and significantly faster parameter inference compared to a model-based iterative reconstruction method.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Fang, R., et al.: Direct estimation of permeability maps for low-dose CT perfusion. In: IEEE ISBI, pp. 739–742, April 2016 Fang, R., et al.: Direct estimation of permeability maps for low-dose CT perfusion. In: IEEE ISBI, pp. 739–742, April 2016
2.
Zurück zum Zitat Guo, Y., et al.: High-resolution whole-brain DCE-MRI using constrained reconstruction. Med. Phys. 43(5), 2013–2023 (2016)CrossRef Guo, Y., et al.: High-resolution whole-brain DCE-MRI using constrained reconstruction. Med. Phys. 43(5), 2013–2023 (2016)CrossRef
3.
Zurück zum Zitat Guo, Y., et al.: Direct estimation of tracer-kinetic parameter maps from highly undersampled brain dynamic contrast enhanced MRI. MRM 78(4), 1566–1578 (2017)CrossRef Guo, Y., et al.: Direct estimation of tracer-kinetic parameter maps from highly undersampled brain dynamic contrast enhanced MRI. MRM 78(4), 1566–1578 (2017)CrossRef
4.
Zurück zum Zitat Heye, A.K., et al.: Tracer kinetic modelling for DCE-MRI quantification of subtle bloodbrain barrier permeability. NeuroImage 125, 446–455 (2016)CrossRef Heye, A.K., et al.: Tracer kinetic modelling for DCE-MRI quantification of subtle bloodbrain barrier permeability. NeuroImage 125, 446–455 (2016)CrossRef
5.
Zurück zum Zitat Kamnitsas, K., et al.: Efficient multi-scale 3d CNN with fully connected CRF for accurate brain lesion segmentation. Med. Image Anal. 36, 61–78 (2017)CrossRef Kamnitsas, K., et al.: Efficient multi-scale 3d CNN with fully connected CRF for accurate brain lesion segmentation. Med. Image Anal. 36, 61–78 (2017)CrossRef
6.
Zurück zum Zitat Lebel, R.M., et al.: Highly accelerated dynamic contrast enhanced imaging. MRM 71(2), 635–644 (2014)CrossRef Lebel, R.M., et al.: Highly accelerated dynamic contrast enhanced imaging. MRM 71(2), 635–644 (2014)CrossRef
7.
Zurück zum Zitat O’Connor, J.P.B., et al.: Dynamic contrast-enhanced MRI in clinical trials of antivascular therapies. Nat. Rev. Clin. Oncol. 9(3), 167–77 (2012)CrossRef O’Connor, J.P.B., et al.: Dynamic contrast-enhanced MRI in clinical trials of antivascular therapies. Nat. Rev. Clin. Oncol. 9(3), 167–77 (2012)CrossRef
8.
Zurück zum Zitat Patlak, C.S., et al.: Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data. J. Cereb. Blood Flow Metab. 3(1), 1–7 (1983)CrossRef Patlak, C.S., et al.: Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data. J. Cereb. Blood Flow Metab. 3(1), 1–7 (1983)CrossRef
9.
Zurück zum Zitat Sourbron, S.P., Buckley, D.L.: Classic models for dynamic contrast-enhanced MRI. NMR Biomed. 26(8), 1004–1027 (2013)CrossRef Sourbron, S.P., Buckley, D.L.: Classic models for dynamic contrast-enhanced MRI. NMR Biomed. 26(8), 1004–1027 (2013)CrossRef
10.
Zurück zum Zitat Zhang, K., et al.: Beyond a gaussian denoiser: residual learning of deep CNN for image denoising. IEEE Trans. Image Process. 26(7), 3142–3155 (2017)MathSciNetCrossRef Zhang, K., et al.: Beyond a gaussian denoiser: residual learning of deep CNN for image denoising. IEEE Trans. Image Process. 26(7), 3142–3155 (2017)MathSciNetCrossRef
11.
Zurück zum Zitat Zhang, T., et al.: Fast pediatric 3d free-breathing abdominal dynamic contrast enhanced MRI with high spatiotemporal resolution. JMRI 41(2), 460–473 (2015)CrossRef Zhang, T., et al.: Fast pediatric 3d free-breathing abdominal dynamic contrast enhanced MRI with high spatiotemporal resolution. JMRI 41(2), 460–473 (2015)CrossRef
12.
Zurück zum Zitat Zhu, Y., et al.: GOCART: GOlden-angle CArtesian randomized time-resolved 3D MRI. Magn. Reson. Imag. 34(7), 940–950 (2016)CrossRef Zhu, Y., et al.: GOCART: GOlden-angle CArtesian randomized time-resolved 3D MRI. Magn. Reson. Imag. 34(7), 940–950 (2016)CrossRef
Metadaten
Titel
Direct Estimation of Pharmacokinetic Parameters from DCE-MRI Using Deep CNN with Forward Physical Model Loss
verfasst von
Cagdas Ulas
Giles Tetteh
Michael J. Thrippleton
Paul A. Armitage
Stephen D. Makin
Joanna M. Wardlaw
Mike E. Davies
Bjoern H. Menze
Copyright-Jahr
2018
DOI
https://doi.org/10.1007/978-3-030-00928-1_5