Skip to main content
Erschienen in: Tribology Letters 3/2015

01.09.2015 | Original Paper

Direct Observation of Layer-by-Layer Wear

verfasst von: Yifeng Liao, Laurence D. Marks

Erschienen in: Tribology Letters | Ausgabe 3/2015

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Wear at the macroscopic scale has been well documented to involve the deformation of sliding interfaces. The mechanical behavior of single asperities in sliding contact, however, is not fully understood. Classical wear mechanisms have not been necessarily substantiated by direct studies of events at the contacting interface and have often contradicted post facto investigations. Wear processes, particularly those under mild loads, are not well understood at the nanoscale to submicron scale. We report here the observation, via in situ transmission electron microscopy, of wear of M23C6 carbides in a CoCrMo alloy sliding against a single silicon asperity. Each slide of the asperity under a normal stress of ~20 MPa resulted in removal of one atomic layer of the carbide. This represents a new type of wear process, which differs from what one would predict from models based on fracture of brittle materials and what has been called atomic wear. For context, we compare the processes and conditions used to those relevant for metal-on-metal hip implants, concluding that these severe wear processes are probably not important for the head/cup junction but could be relevant to fretting wear and corrosion at modular junctions.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Hutchings, I.M.: Tribology: Friction and Wear of Engineering Materials. Edward Arnold, London (1992) Hutchings, I.M.: Tribology: Friction and Wear of Engineering Materials. Edward Arnold, London (1992)
2.
Zurück zum Zitat Williams, J.A.: Engineering Tribology. Oxford University Press, New York (1994) Williams, J.A.: Engineering Tribology. Oxford University Press, New York (1994)
7.
Zurück zum Zitat Mndange-Pfupfu, A., Ciston, J., Eryilmaz, O., Erdemir, A., Marks, L.D.: Direct observation of tribochemically assisted wear on diamond-like carbon thin films. Tribol. Lett. 49(2), 351–356 (2013). doi:10.1007/s11249-012-0074-x CrossRef Mndange-Pfupfu, A., Ciston, J., Eryilmaz, O., Erdemir, A., Marks, L.D.: Direct observation of tribochemically assisted wear on diamond-like carbon thin films. Tribol. Lett. 49(2), 351–356 (2013). doi:10.​1007/​s11249-012-0074-x CrossRef
9.
11.
Zurück zum Zitat Liao, Y., Hoffman, E., Wimmer, M., Fischer, A., Jacobs, J., Marks, L.: CoCrMo metal-on-metal hip replacements. Phys. Chem. Chem. Phys. 15(3), 746–756 (2013). doi:10.1039/c2cp42968c CrossRef Liao, Y., Hoffman, E., Wimmer, M., Fischer, A., Jacobs, J., Marks, L.: CoCrMo metal-on-metal hip replacements. Phys. Chem. Chem. Phys. 15(3), 746–756 (2013). doi:10.​1039/​c2cp42968c CrossRef
12.
Zurück zum Zitat Stemmer, P., Pourzal, R., Liao, Y.F., Marks, L., Morlock, M., Jacobs, J.J., Wimmer, M.A., Fischer, A.: Microstructure of retrievals made from standard cast HC-CoCrMo alloys. Metal. Metal. Total Hip Replace. Devices 1560, 251–267 (2013). doi:10.1520/Stp156020120033 CrossRef Stemmer, P., Pourzal, R., Liao, Y.F., Marks, L., Morlock, M., Jacobs, J.J., Wimmer, M.A., Fischer, A.: Microstructure of retrievals made from standard cast HC-CoCrMo alloys. Metal. Metal. Total Hip Replace. Devices 1560, 251–267 (2013). doi:10.​1520/​Stp156020120033 CrossRef
13.
Zurück zum Zitat Jacobs, J.J., Skipor, A.K., Doorn, P.F., Campbell, P., Schmalzried, T.P., Black, J., Amstutz, H.C.: Cobalt and chromium concentrations in patients with metal on metal total hip replacements. Clin. Orthop. Relat. Res. 329(Suppl), S256–S263 (1996)CrossRef Jacobs, J.J., Skipor, A.K., Doorn, P.F., Campbell, P., Schmalzried, T.P., Black, J., Amstutz, H.C.: Cobalt and chromium concentrations in patients with metal on metal total hip replacements. Clin. Orthop. Relat. Res. 329(Suppl), S256–S263 (1996)CrossRef
14.
Zurück zum Zitat Silva, M., Heisel, C., Schmalzried, T.P.: Metal-on-metal total hip replacement. Clin. Orthop. Relat. Res. 430, 53–61 (2005)CrossRef Silva, M., Heisel, C., Schmalzried, T.P.: Metal-on-metal total hip replacement. Clin. Orthop. Relat. Res. 430, 53–61 (2005)CrossRef
16.
Zurück zum Zitat Dowson, D., McNie, C.M., Goldsmith, A.A.J.: Direct experimental evidence of lubrication in a metal-on-metal total hip replacement tested in a joint simulator. Proc. Int. Mech. Eng. C 214(1), 75–86 (2000). doi:10.1243/0954406001522822 CrossRef Dowson, D., McNie, C.M., Goldsmith, A.A.J.: Direct experimental evidence of lubrication in a metal-on-metal total hip replacement tested in a joint simulator. Proc. Int. Mech. Eng. C 214(1), 75–86 (2000). doi:10.​1243/​0954406001522822​ CrossRef
18.
Zurück zum Zitat Merkle, A.P., Marks, L.D.: A predictive analytical friction model from basic theories of interfaces, contacts and dislocations. Tribol. Lett. 26(1), 73–84 (2007)CrossRef Merkle, A.P., Marks, L.D.: A predictive analytical friction model from basic theories of interfaces, contacts and dislocations. Tribol. Lett. 26(1), 73–84 (2007)CrossRef
19.
20.
Zurück zum Zitat Bowman, A.L., Arnold, G.P., Storms, E.K., Nereson, N.G.: The crystal structure of Cr23C6. Acta Crystallogr. B 28(Oct15), 3102–3103 (1972)CrossRef Bowman, A.L., Arnold, G.P., Storms, E.K., Nereson, N.G.: The crystal structure of Cr23C6. Acta Crystallogr. B 28(Oct15), 3102–3103 (1972)CrossRef
21.
Zurück zum Zitat Maskiewicz, V.K., Williams, P.A., Prates, S.J., Bowsher, J.G., Clarke, I.C.: Characterization of protein degradation in serum-based lubricants during simulation wear testing of metal-on-metal hip prostheses. J. Biomed. Mater. Res. B Appl. Biomater. 94(2), 429–440 (2010). doi:10.1002/jbm.b.31671 Maskiewicz, V.K., Williams, P.A., Prates, S.J., Bowsher, J.G., Clarke, I.C.: Characterization of protein degradation in serum-based lubricants during simulation wear testing of metal-on-metal hip prostheses. J. Biomed. Mater. Res. B Appl. Biomater. 94(2), 429–440 (2010). doi:10.​1002/​jbm.​b.​31671
22.
24.
Zurück zum Zitat Gaytan, S.M., Murr, L.E., Martinez, E., Martinez, J.L., Machado, B.I., Ramirez, D.A., Medina, F., Collins, S., Wicker, R.B.: Comparison of microstructures and mechanical properties for solid and mesh cobalt-base alloy prototypes fabricated by electron beam melting. Metall. Mater. Trans. A 41a(12), 3216–3227 (2010). doi:10.1007/s11661-010-0388-y CrossRef Gaytan, S.M., Murr, L.E., Martinez, E., Martinez, J.L., Machado, B.I., Ramirez, D.A., Medina, F., Collins, S., Wicker, R.B.: Comparison of microstructures and mechanical properties for solid and mesh cobalt-base alloy prototypes fabricated by electron beam melting. Metall. Mater. Trans. A 41a(12), 3216–3227 (2010). doi:10.​1007/​s11661-010-0388-y CrossRef
26.
Zurück zum Zitat Shan, Z.W., Mishra, R.K., Syed Asif, S.A., Warren, O.L., Minor, A.M.: Mechanical annealing and source-limited deformation in submicrometre-diameter Ni crystals. Nat. Mater. 7(2), 115–119 (2008). doi:10.1038/nmat2085 CrossRef Shan, Z.W., Mishra, R.K., Syed Asif, S.A., Warren, O.L., Minor, A.M.: Mechanical annealing and source-limited deformation in submicrometre-diameter Ni crystals. Nat. Mater. 7(2), 115–119 (2008). doi:10.​1038/​nmat2085 CrossRef
27.
Zurück zum Zitat Burwell, J.T., Strang, C.D.: Metallic wear—discussion. Proc. R. Soc. A 212(1111), 470–477 (1952) Burwell, J.T., Strang, C.D.: Metallic wear—discussion. Proc. R. Soc. A 212(1111), 470–477 (1952)
30.
Zurück zum Zitat Brunski, J.B.: BioMaterials Science: an Introduction to Materials in Medicine, 2nd edn. Elsevier, New York (2004) Brunski, J.B.: BioMaterials Science: an Introduction to Materials in Medicine, 2nd edn. Elsevier, New York (2004)
31.
Zurück zum Zitat Oliver, W.C., Pharr, G.M.: An improved technique for determining hardness and elastic-modulus using load and displacement sensing indentation experiments. J. Mater. Res. 7(6), 1564–1583 (1992). doi:10.1557/Jmr.1992.1564 CrossRef Oliver, W.C., Pharr, G.M.: An improved technique for determining hardness and elastic-modulus using load and displacement sensing indentation experiments. J. Mater. Res. 7(6), 1564–1583 (1992). doi:10.​1557/​Jmr.​1992.​1564 CrossRef
32.
Zurück zum Zitat Hopcroft, M.A., Nix, W.D., Kenny, T.W.: What is the young’s modulus of silicon? J. Microelectromech. Syst. 19(2), 229–238 (2010)CrossRef Hopcroft, M.A., Nix, W.D., Kenny, T.W.: What is the young’s modulus of silicon? J. Microelectromech. Syst. 19(2), 229–238 (2010)CrossRef
33.
Zurück zum Zitat Maugis, D.: Adhesion of spheres—the Jkr-Dmt transition using a Dugdale model. J. Colloid Interface Sci. 150(1), 243–269 (1992)CrossRef Maugis, D.: Adhesion of spheres—the Jkr-Dmt transition using a Dugdale model. J. Colloid Interface Sci. 150(1), 243–269 (1992)CrossRef
34.
Zurück zum Zitat Grierson, D.S., Flater, E.E., Carpick, R.W.: Accounting for the JKR-DMT transition in adhesion and friction measurements with atomic force microscopy. J. Adhes. Sci. Technol. 19(3–5), 291–311 (2005). doi:10.1163/1568561054352685 CrossRef Grierson, D.S., Flater, E.E., Carpick, R.W.: Accounting for the JKR-DMT transition in adhesion and friction measurements with atomic force microscopy. J. Adhes. Sci. Technol. 19(3–5), 291–311 (2005). doi:10.​1163/​1568561054352685​ CrossRef
35.
Zurück zum Zitat Derjaguin, B.V., Muller, V.M., Toporov, Y.P.: Effect of contact deformations on adhesion of particles. J. Colloid Interface Sci. 53(2), 314–326 (1975)CrossRef Derjaguin, B.V., Muller, V.M., Toporov, Y.P.: Effect of contact deformations on adhesion of particles. J. Colloid Interface Sci. 53(2), 314–326 (1975)CrossRef
37.
Zurück zum Zitat Kitsunai, H., Hokkirigawa, K., Tsumaki, N., Kato, K.: Transitions of microscopic wear mechanism for Cr2o3 ceramic coatings during repeated sliding observed in a scanning electron-microscope tribosystem. Wear 151(2), 279–289 (1991). doi:10.1016/0043-1648(91)90255-S CrossRef Kitsunai, H., Hokkirigawa, K., Tsumaki, N., Kato, K.: Transitions of microscopic wear mechanism for Cr2o3 ceramic coatings during repeated sliding observed in a scanning electron-microscope tribosystem. Wear 151(2), 279–289 (1991). doi:10.​1016/​0043-1648(91)90255-S CrossRef
38.
Zurück zum Zitat Kitsunai, H., Hokkirigawa, K.: Transitions of microscopic wear mode of silicon-carbide coatings by chemical-vapor-deposition during repeated sliding observed in a scanning electron-microscope tribosystem. Wear 185(1–2), 9–15 (1995). doi:10.1016/0043-1648(94)06580-2 CrossRef Kitsunai, H., Hokkirigawa, K.: Transitions of microscopic wear mode of silicon-carbide coatings by chemical-vapor-deposition during repeated sliding observed in a scanning electron-microscope tribosystem. Wear 185(1–2), 9–15 (1995). doi:10.​1016/​0043-1648(94)06580-2 CrossRef
40.
Zurück zum Zitat Bowden, F.P., Moore, A.J.W., Tabor, D.: The ploughing and adhesion of sliding metals. J. Appl. Phys. 80, 80–91 (1942) Bowden, F.P., Moore, A.J.W., Tabor, D.: The ploughing and adhesion of sliding metals. J. Appl. Phys. 80, 80–91 (1942)
41.
42.
Zurück zum Zitat Mader, W., Knauss, D.: Equilibrium position of misfit dislocations at planar interfaces. Acta Metall. Mater. 40, S207–S215 (1992)CrossRef Mader, W., Knauss, D.: Equilibrium position of misfit dislocations at planar interfaces. Acta Metall. Mater. 40, S207–S215 (1992)CrossRef
43.
44.
Zurück zum Zitat Gotsmann, B., Lantz, M.A.: Atomistic wear in a single asperity sliding contact. Phys. Rev. Lett. 101(12), 125501–125504 (2008) Gotsmann, B., Lantz, M.A.: Atomistic wear in a single asperity sliding contact. Phys. Rev. Lett. 101(12), 125501–125504 (2008)
45.
Zurück zum Zitat Bhaskaran, H., Gotsmann, B., Sebastian, A., Drechsler, U., Lantz, M.A., Despont, M., Jaroenapibal, P., Carpick, R.W., Chen, Y., Sridharan, K.: Ultralow nanoscale wear through atom-by-atom attrition in silicon-containing diamond-like carbon. Nat. Nanotechnol. 5(3), 181–185 (2010). doi:10.1038/Nnano.2010.3 CrossRef Bhaskaran, H., Gotsmann, B., Sebastian, A., Drechsler, U., Lantz, M.A., Despont, M., Jaroenapibal, P., Carpick, R.W., Chen, Y., Sridharan, K.: Ultralow nanoscale wear through atom-by-atom attrition in silicon-containing diamond-like carbon. Nat. Nanotechnol. 5(3), 181–185 (2010). doi:10.​1038/​Nnano.​2010.​3 CrossRef
46.
Zurück zum Zitat Gnecco, E., Bennewitz, R., Meyer, E.: Abrasive wear on the atomic scale. Phys. Rev. Lett. 88(21) (2002) Gnecco, E., Bennewitz, R., Meyer, E.: Abrasive wear on the atomic scale. Phys. Rev. Lett. 88(21) (2002)
47.
49.
Zurück zum Zitat Mathew, M.T., Nagelli, C., Pourzal, R., Fischer, A., Laurent, M.P., Jacobs, J.J., Wimmer, M.A.: Tribolayer formation in a metal-on-metal (MoM) hip joint: an electrochemical investigation. J. Mech. Behav. Biomed. 29, 199–212 (2014). doi:10.1016/j.jmbbm.2013.08.018 CrossRef Mathew, M.T., Nagelli, C., Pourzal, R., Fischer, A., Laurent, M.P., Jacobs, J.J., Wimmer, M.A.: Tribolayer formation in a metal-on-metal (MoM) hip joint: an electrochemical investigation. J. Mech. Behav. Biomed. 29, 199–212 (2014). doi:10.​1016/​j.​jmbbm.​2013.​08.​018 CrossRef
50.
52.
Zurück zum Zitat Billi, F., Benya, P., Kavanaugh, A., Adams, J., McKellop, H., Ebramzadeh, E.: The John Charnley Award: an accurate and extremely sensitive method to separate, display, and characterize wear debris: part 2: metal and ceramic particles. Clin. Orthop. Relat. Res. 470(2), 339–350 (2012). doi:10.1007/s11999-011-2058-9 CrossRef Billi, F., Benya, P., Kavanaugh, A., Adams, J., McKellop, H., Ebramzadeh, E.: The John Charnley Award: an accurate and extremely sensitive method to separate, display, and characterize wear debris: part 2: metal and ceramic particles. Clin. Orthop. Relat. Res. 470(2), 339–350 (2012). doi:10.​1007/​s11999-011-2058-9 CrossRef
54.
Zurück zum Zitat Lappalainen, R., Selenius, M., Anttila, A., Konttinen, Y.T., Santavirta, S.S.: Reduction of wear in total hip replacement prostheses by amorphous diamond coatings. J. Biomed. Mater. Res. B Appl. Biomater. 66(1), 410–413 (2003). doi:10.1002/jbm.b.10026 CrossRef Lappalainen, R., Selenius, M., Anttila, A., Konttinen, Y.T., Santavirta, S.S.: Reduction of wear in total hip replacement prostheses by amorphous diamond coatings. J. Biomed. Mater. Res. B Appl. Biomater. 66(1), 410–413 (2003). doi:10.​1002/​jbm.​b.​10026 CrossRef
55.
Zurück zum Zitat Firkins, P.J., Tipper, J.L., Saadatzadeh, M.R., Ingham, E., Stone, M.H., Farrar, R., Fisher, J.: Quantitative analysis of wear and wear debris from metal-on-metal hip prostheses tested in a physiological hip joint simulator. Biomed. Mater. Eng. 11(2), 143–157 (2001) Firkins, P.J., Tipper, J.L., Saadatzadeh, M.R., Ingham, E., Stone, M.H., Farrar, R., Fisher, J.: Quantitative analysis of wear and wear debris from metal-on-metal hip prostheses tested in a physiological hip joint simulator. Biomed. Mater. Eng. 11(2), 143–157 (2001)
56.
Zurück zum Zitat Tipper, J.L., Firkins, P.J., Ingham, E., Fisher, J., Stone, M.H., Farrar, R.: Quantitative analysis of the wear and wear debris from low and high carbon content cobalt chrome alloys used in metal on metal total hip replacements. J. Mater. Sci. Mater. Med. 10(6), 353–362 (1999). doi:10.1023/A:1026473723777 CrossRef Tipper, J.L., Firkins, P.J., Ingham, E., Fisher, J., Stone, M.H., Farrar, R.: Quantitative analysis of the wear and wear debris from low and high carbon content cobalt chrome alloys used in metal on metal total hip replacements. J. Mater. Sci. Mater. Med. 10(6), 353–362 (1999). doi:10.​1023/​A:​1026473723777 CrossRef
57.
Zurück zum Zitat Chan, F.W., Bobyn, J.D., Medley, J.B., Krygier, J.J., Tanzer, M.: The Otto Aufranc Award. Wear and lubrication of metal-on-metal hip implants. Clin. Orthop. Relat. Res. 369, 10–24 (1999)CrossRef Chan, F.W., Bobyn, J.D., Medley, J.B., Krygier, J.J., Tanzer, M.: The Otto Aufranc Award. Wear and lubrication of metal-on-metal hip implants. Clin. Orthop. Relat. Res. 369, 10–24 (1999)CrossRef
58.
Zurück zum Zitat Wimmer, M.A., Sprecher, C., Hauert, R., Tager, G., Fischer, A.: Tribochemical reaction on metal-on-metal hip joint bearings—a comparison between in vitro and in vivo results. Wear 255, 1007–1014 (2003). doi:10.1016/S0043-1648(03)00127-3 CrossRef Wimmer, M.A., Sprecher, C., Hauert, R., Tager, G., Fischer, A.: Tribochemical reaction on metal-on-metal hip joint bearings—a comparison between in vitro and in vivo results. Wear 255, 1007–1014 (2003). doi:10.​1016/​S0043-1648(03)00127-3 CrossRef
59.
Zurück zum Zitat Yan, Y., Neville, A., Dowson, D.: Biotribocorrosion—an appraisal of the time dependence of wear and corrosion interactions: I. The role of corrosion. J. Phys. D Appl. Phys. 39(15), 3200–3205 (2006). doi:10.1088/0022-3727/39/15/S10 CrossRef Yan, Y., Neville, A., Dowson, D.: Biotribocorrosion—an appraisal of the time dependence of wear and corrosion interactions: I. The role of corrosion. J. Phys. D Appl. Phys. 39(15), 3200–3205 (2006). doi:10.​1088/​0022-3727/​39/​15/​S10 CrossRef
61.
Zurück zum Zitat Pourzal, R., Martin, E.J., Vajpayee, S., Liao, Y., Wimmer, M.A., Shull, K.R.: Investigation of the role of tribofilms in self-mating CoCrMo systems utilizing a quartz crystal microtribometer. Tribol. Int. 72, 161–171 (2014). doi:10.1016/j.triboint.2013.12.015 CrossRef Pourzal, R., Martin, E.J., Vajpayee, S., Liao, Y., Wimmer, M.A., Shull, K.R.: Investigation of the role of tribofilms in self-mating CoCrMo systems utilizing a quartz crystal microtribometer. Tribol. Int. 72, 161–171 (2014). doi:10.​1016/​j.​triboint.​2013.​12.​015 CrossRef
62.
Zurück zum Zitat Martin, E.J., Pourzal, R., Mathew, M.T., Shull, K.R.: Dominant role of molybdenum in the electrochemical deposition of biological macromolecules on metallic surfaces. Langmuir 29(15), 4813–4822 (2013). doi:10.1021/la304046q CrossRef Martin, E.J., Pourzal, R., Mathew, M.T., Shull, K.R.: Dominant role of molybdenum in the electrochemical deposition of biological macromolecules on metallic surfaces. Langmuir 29(15), 4813–4822 (2013). doi:10.​1021/​la304046q CrossRef
63.
Zurück zum Zitat Liao, Y., Pourzal, R., Wimmer, M.A., Jacobs, J.J., Fischer, A., Marks, L.D.: Graphitic tribological layers in metal-on-metal hip replacements. Science 334(6063), 1687–1690 (2011). doi:10.1126/science.1213902 CrossRef Liao, Y., Pourzal, R., Wimmer, M.A., Jacobs, J.J., Fischer, A., Marks, L.D.: Graphitic tribological layers in metal-on-metal hip replacements. Science 334(6063), 1687–1690 (2011). doi:10.​1126/​science.​1213902 CrossRef
64.
Zurück zum Zitat John Cooper, H., Della Valle, C.J., Berger, R.A., Tetreault, M., Paprosky, W.G., Sporer, S.M., Jacobs, J.J.: Corrosion at the head-neck taper as a cause for adverse local tissue reactions after total hip arthroplasty. J. Bone Joint Surg. 94(18), 1655–1661 (2012). doi:10.2106/jbjs.k.01352 CrossRef John Cooper, H., Della Valle, C.J., Berger, R.A., Tetreault, M., Paprosky, W.G., Sporer, S.M., Jacobs, J.J.: Corrosion at the head-neck taper as a cause for adverse local tissue reactions after total hip arthroplasty. J. Bone Joint Surg. 94(18), 1655–1661 (2012). doi:10.​2106/​jbjs.​k.​01352 CrossRef
65.
Zurück zum Zitat Gilbert, J.L., Sivan, S., Liu, Y., Kocagoz, S.B., Arnholt, C.M., Kurtz, S.M.: Direct in vivo inflammatory cell-induced corrosion of CoCrMo alloy orthopedic implant surfaces. J. Biomed. Mater. Res. A (2014). doi:10.1002/jbm.a.35165 Gilbert, J.L., Sivan, S., Liu, Y., Kocagoz, S.B., Arnholt, C.M., Kurtz, S.M.: Direct in vivo inflammatory cell-induced corrosion of CoCrMo alloy orthopedic implant surfaces. J. Biomed. Mater. Res. A (2014). doi:10.​1002/​jbm.​a.​35165
66.
Zurück zum Zitat Cooper, H.J., Urban, R.M., Wixson, R.L., Meneghini, R.M., Jacobs, J.J.: Adverse local tissue reaction arising from corrosion at the femoral neck-body junction in a dual-taper stem with a cobalt-chromium modular neck. J. Bone Joint Surg. Am. 95(10), 865–872 (2013). doi:10.2106/JBJS.L.01042 CrossRef Cooper, H.J., Urban, R.M., Wixson, R.L., Meneghini, R.M., Jacobs, J.J.: Adverse local tissue reaction arising from corrosion at the femoral neck-body junction in a dual-taper stem with a cobalt-chromium modular neck. J. Bone Joint Surg. Am. 95(10), 865–872 (2013). doi:10.​2106/​JBJS.​L.​01042 CrossRef
67.
69.
Zurück zum Zitat Nassif, N.A., Nawabi, D.H., Stoner, K., Elpers, M., Wright, T., Padgett, D.E.: Taper design affects failure of large-head metal-on-metal total hip replacements. Clin. Orthop. Relat. Res. 472(2), 564–571 (2014). doi:10.1007/s11999-013-3115-3 CrossRef Nassif, N.A., Nawabi, D.H., Stoner, K., Elpers, M., Wright, T., Padgett, D.E.: Taper design affects failure of large-head metal-on-metal total hip replacements. Clin. Orthop. Relat. Res. 472(2), 564–571 (2014). doi:10.​1007/​s11999-013-3115-3 CrossRef
70.
Zurück zum Zitat Pivec, R., Meneghini, R.M., Hozack, W.J., Westrich, G.H., Mont, M.A.: Modular taper junction corrosion and failure: how to approach a recalled total hip arthroplasty implant. J. Arthroplasty 29(1), 1–6 (2014). doi:10.1016/j.arth.2013.08.026 CrossRef Pivec, R., Meneghini, R.M., Hozack, W.J., Westrich, G.H., Mont, M.A.: Modular taper junction corrosion and failure: how to approach a recalled total hip arthroplasty implant. J. Arthroplasty 29(1), 1–6 (2014). doi:10.​1016/​j.​arth.​2013.​08.​026 CrossRef
72.
74.
Zurück zum Zitat Double, D.D., Zambelli, G.: Microstructure and crystallography of directionally solidified (Co, Ni)-Cr23c6 eutectic alloy. J. Mater. Sci. 13(3), 534–540 (1978). doi:10.1007/Bf00541803 CrossRef Double, D.D., Zambelli, G.: Microstructure and crystallography of directionally solidified (Co, Ni)-Cr23c6 eutectic alloy. J. Mater. Sci. 13(3), 534–540 (1978). doi:10.​1007/​Bf00541803 CrossRef
Metadaten
Titel
Direct Observation of Layer-by-Layer Wear
verfasst von
Yifeng Liao
Laurence D. Marks
Publikationsdatum
01.09.2015
Verlag
Springer US
Erschienen in
Tribology Letters / Ausgabe 3/2015
Print ISSN: 1023-8883
Elektronische ISSN: 1573-2711
DOI
https://doi.org/10.1007/s11249-015-0567-5

Weitere Artikel der Ausgabe 3/2015

Tribology Letters 3/2015 Zur Ausgabe

    Marktübersichten

    Die im Laufe eines Jahres in der „adhäsion“ veröffentlichten Marktübersichten helfen Anwendern verschiedenster Branchen, sich einen gezielten Überblick über Lieferantenangebote zu verschaffen.