Skip to main content
Erschienen in: Fire Technology 5/2019

15.03.2019

Discrimination Between Fire Smokes and Nuisance Aerosols Using Asymmetry Ratio and Two Wavelengths

verfasst von: Rong Zheng, Dan Zhang, Song Lu, Shen-Lin Yang

Erschienen in: Fire Technology | Ausgabe 5/2019

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Optical smoke detectors are very prone to produce false alarms and cause a great economic loss when exposed to interference particles, i.e. non-fire aerosols. This paper aims to study the discrimination between fire smokes and two common nuisance particles (i.e. dusts and water particles) based on the asymmetry ratio (AR, the ratio of forward to backward scattered light signals). The experiments were conducted using a home-made detector model and the forward- and backward-scattering angle are 45° and 135° respectively. The test process refers to the Society of Automotive Engineers Aerospace Standard 8036A. Fire smokes, standard dusts and water steam/mists were tested in this study. The effect of particles pollution was firstly studied. Due to the pollution of dust particles on the detector model, the forward signal increases significantly, leading to obvious deviation on the asymmetry ratio. Experiments of fire smokes show that a balance response between the soot and smoldering particles can be achieved based on the asymmetry ratio. By comparing the asymmetry ratios of fire smokes and nuisance aerosols, it is found that we can use the short wavelength (i.e. 405 nm) to distinguish the smoldering particles (the ARs range is 6.8–7.6) from nuisance aerosols, and long wavelength (i.e. 870 nm) to separate the soot particles (the ARs range is 2.2–3.5) and as well the cotton smoldering particles (the ARs range is 10.1–10.6) from nuisance aerosols. Moreover, results also show that nuisance aerosols cover wide ranges of asymmetry ratios, i.e. about 3.4–6.1 at 405 nm and 4.2–8.2 at 870 nm. This suggests that further work is needed to help the differentiation of aerosols.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Dinaburg J, Gottuk D (2016) Smoke alarm nuisance source characterization: review and recommendations. Fire Technol 52:1197–1233CrossRef Dinaburg J, Gottuk D (2016) Smoke alarm nuisance source characterization: review and recommendations. Fire Technol 52:1197–1233CrossRef
2.
Zurück zum Zitat Breen DE (1985) False fire alarms in college dormitories-the problem revisited. Technical Report, SFPE, Boston, MA Breen DE (1985) False fire alarms in college dormitories-the problem revisited. Technical Report, SFPE, Boston, MA
3.
Zurück zum Zitat Mickalide A, Validzic A (1999) Smoke alarm maintenance in low income families. Am J Public Health 89(10):1584CrossRef Mickalide A, Validzic A (1999) Smoke alarm maintenance in low income families. Am J Public Health 89(10):1584CrossRef
4.
Zurück zum Zitat Kuklinski D, Berger L, Weaver J (1996) Smoke detector nuisance alarms: a field study in a native American Community. NFPA J 90(5): 65–72 Kuklinski D, Berger L, Weaver J (1996) Smoke detector nuisance alarms: a field study in a native American Community. NFPA J 90(5): 65–72
5.
Zurück zum Zitat Krüll W, Schultze T, Tobera R, Willms I (2013) Analysis of dust properties to solve the complex problem of non-fire sensitivity testing of optical smoke detectors. Proc Eng 62:859–867CrossRef Krüll W, Schultze T, Tobera R, Willms I (2013) Analysis of dust properties to solve the complex problem of non-fire sensitivity testing of optical smoke detectors. Proc Eng 62:859–867CrossRef
6.
Zurück zum Zitat Pesch M (2009) Kontinuierliche Messung von Partikelgrößenverteilungen (wide range) am Hohenpeißenberg. In: Seminar “Nanopartikel in der Atmosphäre, Quellen-(Aus) Wirkungen-Messtechnik”, Berlin Pesch M (2009) Kontinuierliche Messung von Partikelgrößenverteilungen (wide range) am Hohenpeißenberg. In: Seminar “Nanopartikel in der Atmosphäre, Quellen-(Aus) Wirkungen-Messtechnik”, Berlin
7.
Zurück zum Zitat Loepfe M, Ryser P, Tompkin C, Wieser D (1997) Optical properties of fire and non-fire aerosols. Fire Saf J 29:185–194CrossRef Loepfe M, Ryser P, Tompkin C, Wieser D (1997) Optical properties of fire and non-fire aerosols. Fire Saf J 29:185–194CrossRef
8.
Zurück zum Zitat Gottuk DT, Peatross MJ, Roby RJ, Beyler CL (2002) Advanced fire detection using multi-signature alarm algorithms. Fire Saf J 37:381–394CrossRef Gottuk DT, Peatross MJ, Roby RJ, Beyler CL (2002) Advanced fire detection using multi-signature alarm algorithms. Fire Saf J 37:381–394CrossRef
9.
Zurück zum Zitat Deng T, Wang S, Zhu M (2016) Dual-wavelength optical sensor for measuring the surface area concentration and the volume concentration of aerosols. Sens Actuators B Chem 236:334–342CrossRef Deng T, Wang S, Zhu M (2016) Dual-wavelength optical sensor for measuring the surface area concentration and the volume concentration of aerosols. Sens Actuators B Chem 236:334–342CrossRef
10.
Zurück zum Zitat Deng T, Wang S, Xiao X, M. Zhu (2017) Eliminating the effects of refractive indices for both white smokes and black smokes in optical fire detector. Sens Actuators B Chem 253:187–195CrossRef Deng T, Wang S, Xiao X, M. Zhu (2017) Eliminating the effects of refractive indices for both white smokes and black smokes in optical fire detector. Sens Actuators B Chem 253:187–195CrossRef
11.
Zurück zum Zitat Philipp JB, Kirbach K, Hofmann M, Hppfe A, Schank M (2017) False alarm resisting smoke detector for mobility application. In: 16th international conference on automatic fire detection, Maryland, America Philipp JB, Kirbach K, Hofmann M, Hppfe A, Schank M (2017) False alarm resisting smoke detector for mobility application. In: 16th international conference on automatic fire detection, Maryland, America
12.
Zurück zum Zitat Weinert DW, Cleary TG, Mulholland GW, Beever PF (2003) Light scattering characteristics and size distribution of smoke and nuisance aerosols. In: Fire Safety Science, pp 209–220 Weinert DW, Cleary TG, Mulholland GW, Beever PF (2003) Light scattering characteristics and size distribution of smoke and nuisance aerosols. In: Fire Safety Science, pp 209–220
13.
Zurück zum Zitat Mulholland GW (1995) Smoke production and properties SFPE. Handbook of fire protection engineering, 2nd edn. National Fire Protection Association, Quincy, pp 4–167 Mulholland GW (1995) Smoke production and properties SFPE. Handbook of fire protection engineering, 2nd edn. National Fire Protection Association, Quincy, pp 4–167
14.
Zurück zum Zitat Loepfe M, Nebiker P, Burtscher H (2006) On-line determination of the optical properties of particles produced by test fires. Fire Saf J 41:266–273CrossRef Loepfe M, Nebiker P, Burtscher H (2006) On-line determination of the optical properties of particles produced by test fires. Fire Saf J 41:266–273CrossRef
15.
Zurück zum Zitat Jurányi Z, Burtscher H, Loepfe M et al (2015) Dual-wavelength light-scattering technique for selective detection of volcanic ash particles in the presence of water droplets. Atmos Meas Tech 8:5213–5222CrossRef Jurányi Z, Burtscher H, Loepfe M et al (2015) Dual-wavelength light-scattering technique for selective detection of volcanic ash particles in the presence of water droplets. Atmos Meas Tech 8:5213–5222CrossRef
16.
Zurück zum Zitat Fernandes GE, Pan YL, Chang RK, Aptowicz K, Pinnick RG (2006) Simultaneous forward-and backward-hemisphere elastic-light-scattering patterns of respirable-size aerosols. Opt Lett 31:3034–3036CrossRef Fernandes GE, Pan YL, Chang RK, Aptowicz K, Pinnick RG (2006) Simultaneous forward-and backward-hemisphere elastic-light-scattering patterns of respirable-size aerosols. Opt Lett 31:3034–3036CrossRef
17.
Zurück zum Zitat Wang A, Wang J, Yang Z, Zu M (2004) Research on dust-proof performance of photoelectric smoke detector. In: 13th international conference on automatic fire detection, Duisburg, Germany Wang A, Wang J, Yang Z, Zu M (2004) Research on dust-proof performance of photoelectric smoke detector. In: 13th international conference on automatic fire detection, Duisburg, Germany
18.
Zurück zum Zitat Müller K, Loepfe M, Wieser D (2006) Optical simulations for fire detectors. Fire Saf J 41:274–278CrossRef Müller K, Loepfe M, Wieser D (2006) Optical simulations for fire detectors. Fire Saf J 41:274–278CrossRef
19.
Zurück zum Zitat Zheng R, Cheng Y, Lu S, Zhang HP (2016) Improved simulation method for optimizing optical chamber of photoelectric smoke detectors. In: IEEE international conference on aircraft utility systems, pp 414–418 Zheng R, Cheng Y, Lu S, Zhang HP (2016) Improved simulation method for optimizing optical chamber of photoelectric smoke detectors. In: IEEE international conference on aircraft utility systems, pp 414–418
20.
Zurück zum Zitat EN 54-7 (2001) Fire detection and fire alarm systems—Part 7: smoke detectors: point detectors using scattered light, transmitted light or ionization. European Committee for Standardization EN 54-7 (2001) Fire detection and fire alarm systems—Part 7: smoke detectors: point detectors using scattered light, transmitted light or ionization. European Committee for Standardization
21.
Zurück zum Zitat SAE Aerospace Standard AS 8036 (2013) Cargo Compartment Fire Detection Instruments, Rev. A SAE Aerospace Standard AS 8036 (2013) Cargo Compartment Fire Detection Instruments, Rev. A
22.
Zurück zum Zitat Krüll W, Schultze T, Willms I, Freiling A (2011) Developments in non-fire sensitivity testing of optical smoke detectors—proposal for a new test method. Fire Saf Sci 10:543–554CrossRef Krüll W, Schultze T, Willms I, Freiling A (2011) Developments in non-fire sensitivity testing of optical smoke detectors—proposal for a new test method. Fire Saf Sci 10:543–554CrossRef
23.
Zurück zum Zitat Tobera R, Krüll W, Schultze T, Willms I (2014) Apparatus for the test of fire detectors in high foggy environments. In: 15th international conference on automatic fire detection, Duisburg, Germany Tobera R, Krüll W, Schultze T, Willms I (2014) Apparatus for the test of fire detectors in high foggy environments. In: 15th international conference on automatic fire detection, Duisburg, Germany
24.
Zurück zum Zitat Krüll W, Schultze T, Willms I (2017) Non-fire sensitivity testing of optical smoke detectors. In: 16th international conference on automatic fire detection, Maryland, America Krüll W, Schultze T, Willms I (2017) Non-fire sensitivity testing of optical smoke detectors. In: 16th international conference on automatic fire detection, Maryland, America
25.
Zurück zum Zitat ISO 12103-1 (1997) Road vehicles—Test dust for filter evaluation—Arizona Test Dust ISO 12103-1 (1997) Road vehicles—Test dust for filter evaluation—Arizona Test Dust
26.
Zurück zum Zitat US Department of Commerce, NIST (1999) Evaluating multi-sensor fire detectors in the fire emulator/detector evaluator. In: International interflam conference, 8th Proceedings, vol 1 US Department of Commerce, NIST (1999) Evaluating multi-sensor fire detectors in the fire emulator/detector evaluator. In: International interflam conference, 8th Proceedings, vol 1
27.
Zurück zum Zitat Wolin SD, Ryder NL, Leprince F et al (2001) Measurements of smoke characteristics in HVAC ducts. Fire Technol 37(4):363–395CrossRef Wolin SD, Ryder NL, Leprince F et al (2001) Measurements of smoke characteristics in HVAC ducts. Fire Technol 37(4):363–395CrossRef
28.
Zurück zum Zitat Zhang HP, Zheng R, Guan Y, Lu S, Cheng Y (2017) A kind of pipe fluid switch with adjustable switching speed, Patent CN106838377A (in Chinese) Zhang HP, Zheng R, Guan Y, Lu S, Cheng Y (2017) A kind of pipe fluid switch with adjustable switching speed, Patent CN106838377A (in Chinese)
29.
Zurück zum Zitat Cruse GM, Watson P, Knight RD (2017) Conical light absorber for smoke detector, Patent CN106574989A (in Chinese) Cruse GM, Watson P, Knight RD (2017) Conical light absorber for smoke detector, Patent CN106574989A (in Chinese)
30.
Zurück zum Zitat Yang SL, Lu S, Cheng XD, Zheng R, Yuen RKK (2016) Smoke production and fractal structure properties of soot from n-heptane pool fires under low pressures. Fire Technol 52:1915–1937CrossRef Yang SL, Lu S, Cheng XD, Zheng R, Yuen RKK (2016) Smoke production and fractal structure properties of soot from n-heptane pool fires under low pressures. Fire Technol 52:1915–1937CrossRef
31.
Zurück zum Zitat Geiman JA, Gottuk DT, Milke JA (2006) Evaluation of smoke detector response estimation methods optical density, temperature rise, and velocity at alarm. J Fire Prot Eng 16:251–268CrossRef Geiman JA, Gottuk DT, Milke JA (2006) Evaluation of smoke detector response estimation methods optical density, temperature rise, and velocity at alarm. J Fire Prot Eng 16:251–268CrossRef
Metadaten
Titel
Discrimination Between Fire Smokes and Nuisance Aerosols Using Asymmetry Ratio and Two Wavelengths
verfasst von
Rong Zheng
Dan Zhang
Song Lu
Shen-Lin Yang
Publikationsdatum
15.03.2019
Verlag
Springer US
Erschienen in
Fire Technology / Ausgabe 5/2019
Print ISSN: 0015-2684
Elektronische ISSN: 1572-8099
DOI
https://doi.org/10.1007/s10694-019-00829-5

Weitere Artikel der Ausgabe 5/2019

Fire Technology 5/2019 Zur Ausgabe