Skip to main content

01.06.2015

Distributed Scan Like Fault Detection and Test Optimization for Digital Microfluidic Biochips

verfasst von: Subhamita Mukherjee, Tuhina Samanta

Erschienen in: Journal of Electronic Testing | Ausgabe 3/2015

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Development of digital microfluidic biochips (DMFB) has faced a major setback from the threats of faulty and erroneous fluidic operations. Defective electrodes are the main reason for this misleading assay performance. It also affects the assay completion time and overall turnaround time. In this present article, a fast fault diagnosis mechanism is discussed to identify the defective locations of electrode array. The proposed fault detection method is governed by a distributed dispensing and scheduling of test droplets on a 2-D biochip. Water droplets are strategically routed across the DMFB board and quantified at every location using cost effective photodiode sensors. Multiple test droplets are routed on the chip in a time synchronized manner to avoid any routing conflict or failure in diagnosis. This concurrent test droplet circulation incurs optimum layover period and parallel and multiple test droplet movement enhances the fault detection performance. Completeness of the fault analysis is ensured with a sequential post processing as well. Test results of this approach have recorded some substantial improvement in terms of fault detection time and accuracy.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Weitere Produktempfehlungen anzeigen
Literatur
1.
Zurück zum Zitat Chakrabarty K (2010) Design automation and test solutions for digital microfluidic biochips. IEEE TCAS I 57(1):4–17MathSciNet Chakrabarty K (2010) Design automation and test solutions for digital microfluidic biochips. IEEE TCAS I 57(1):4–17MathSciNet
2.
Zurück zum Zitat Chen Y, Khwa WSV, Yu MHV (2010) Fault detection and fault tolerant design for microfluidic based biochips. Proc of EIASC. 1–8 Chen Y, Khwa WSV, Yu MHV (2010) Fault detection and fault tolerant design for microfluidic based biochips. Proc of EIASC. 1–8
3.
Zurück zum Zitat Cho SK, Fan SK, Moon H, Kim CJ (2002) Towards digital microuidic circuits: creating, transporting, cutting and merging liquid droplets by electrowetting-based actuation. Proc MEMS. 32–35 Cho SK, Fan SK, Moon H, Kim CJ (2002) Towards digital microuidic circuits: creating, transporting, cutting and merging liquid droplets by electrowetting-based actuation. Proc MEMS. 32–35
4.
Zurück zum Zitat Datta S, Joshi B, Ravindran A, Mukherjee A (2009) Efficient parallel testing and diagnosis of digital microfluidic biochips. ACM J Emerg Technol Comput Syst 5(2):10.1–10.17, Article 10 CrossRef Datta S, Joshi B, Ravindran A, Mukherjee A (2009) Efficient parallel testing and diagnosis of digital microfluidic biochips. ACM J Emerg Technol Comput Syst 5(2):10.1–10.17, Article 10 CrossRef
5.
Zurück zum Zitat Hu K, Hsu BN, Madison A, Chakrabarty K; Fair RB (2013) Fault detection, real time error recovery and experimental demonstration for digital microfluidic biochips. Proc Des Autom Test Eur. 559–564 Hu K, Hsu BN, Madison A, Chakrabarty K; Fair RB (2013) Fault detection, real time error recovery and experimental demonstration for digital microfluidic biochips. Proc Des Autom Test Eur. 559–564
6.
7.
Zurück zum Zitat Luo Y, Chakrabarty K, Ho TY (2013) Error recovery in cyberphysical digital microfluidic biochips. IEEE Trans Comput-Aided Des Integr Circuits Syst 32(1):59–72CrossRef Luo Y, Chakrabarty K, Ho TY (2013) Error recovery in cyberphysical digital microfluidic biochips. IEEE Trans Comput-Aided Des Integr Circuits Syst 32(1):59–72CrossRef
8.
Zurück zum Zitat Majumder M (2012) A novel single-fault detection technique of digital microfluidic biochip. Int J Comput Sci Its Applications [ISSN 2250–3765], VI – I-1(16);92–95 Majumder M (2012) A novel single-fault detection technique of digital microfluidic biochip. Int J Comput Sci Its Applications [ISSN 2250–3765], VI – I-1(16);92–95
9.
Zurück zum Zitat Mitra D, Ghoshal S, Rahaman H, Chakrabarty K, Bhattacharya BB (2011) Test planning in digital microfluidic biochips using efficient eulerization techniques. J Electron Test 27(5):657–671 Mitra D, Ghoshal S, Rahaman H, Chakrabarty K, Bhattacharya BB (2011) Test planning in digital microfluidic biochips using efficient eulerization techniques. J Electron Test 27(5):657–671
10.
Zurück zum Zitat Mitra D, Ghoshal S, Rahaman H, Chakrabarty K, Bhattacharya BB (2012) Online error detection in digital microfluidic biochips. Proc IEEE 21st Asian Test Symposium. 332–337 Mitra D, Ghoshal S, Rahaman H, Chakrabarty K, Bhattacharya BB (2012) Online error detection in digital microfluidic biochips. Proc IEEE 21st Asian Test Symposium. 332–337
11.
Zurück zum Zitat Pollock M, Shenderov AD, Fair RB (2002) Electrowetting-based actuation of droplets for integrated microfluidics. Lab Chip 2(2):96–101CrossRef Pollock M, Shenderov AD, Fair RB (2002) Electrowetting-based actuation of droplets for integrated microfluidics. Lab Chip 2(2):96–101CrossRef
12.
Zurück zum Zitat Roy P, Rahaman H, Gupta P, Dasgupta P (2013) A new customized testing technique using a novel design of droplet motion detector for digital microfluidic biochip systems. Proc. ICACCI. 897–902 Roy P, Rahaman H, Gupta P, Dasgupta P (2013) A new customized testing technique using a novel design of droplet motion detector for digital microfluidic biochip systems. Proc. ICACCI. 897–902
13.
Zurück zum Zitat Schulte TH, Bardell RL, Weigl BH (2002) Microfluidic technologies in clinical diagnostics. Clin Chim Acta 321:1–10CrossRef Schulte TH, Bardell RL, Weigl BH (2002) Microfluidic technologies in clinical diagnostics. Clin Chim Acta 321:1–10CrossRef
14.
Zurück zum Zitat Su F, Chakrabarty K (2006) Defect tolerance based on graceful degradation and dynamic reconfiguration for digital microfluidics based biochips. IEEE Trans Comput-Aided Des Integr Circuits Syst 25(12):2944–2953CrossRef Su F, Chakrabarty K (2006) Defect tolerance based on graceful degradation and dynamic reconfiguration for digital microfluidics based biochips. IEEE Trans Comput-Aided Des Integr Circuits Syst 25(12):2944–2953CrossRef
15.
Zurück zum Zitat Su F, Chakrabarty K, Fair RB (2006) Microfluidics-based biochips: technology issues, implementation platforms, and design automation challenges. IEEE Trans Comput-Aided Des Integr Circuits Syst 25(2):265–277CrossRef Su F, Chakrabarty K, Fair RB (2006) Microfluidics-based biochips: technology issues, implementation platforms, and design automation challenges. IEEE Trans Comput-Aided Des Integr Circuits Syst 25(2):265–277CrossRef
16.
Zurück zum Zitat Su F, Hwang W, Mukherjee A, Chakrabarty K (2005) Defect oriented testing and diagnosis of digital microfluidics based biochips. Proc Int Test Conf 21(2):1–10 Su F, Hwang W, Mukherjee A, Chakrabarty K (2005) Defect oriented testing and diagnosis of digital microfluidics based biochips. Proc Int Test Conf 21(2):1–10
17.
Zurück zum Zitat Su F, Hwang W, Mukherjee A, Chakrabarty K (2007) Testing and diagnostics of realistic defects in digital microfluidic biochips. J Electron Testing: Theory and Applications 23:219–233CrossRef Su F, Hwang W, Mukherjee A, Chakrabarty K (2007) Testing and diagnostics of realistic defects in digital microfluidic biochips. J Electron Testing: Theory and Applications 23:219–233CrossRef
18.
Zurück zum Zitat Su F, Ozev S, Chakrabarty K (2003) Testing of droplet-based microelectrofluidic systems. Proce IEEE Int Test Cong 1:1192–1200 Su F, Ozev S, Chakrabarty K (2003) Testing of droplet-based microelectrofluidic systems. Proce IEEE Int Test Cong 1:1192–1200
19.
Zurück zum Zitat Wang WC, Yee S, Reinhall P (1995) Optical viscosity sensor using forward light scattering. Sensors Actuators B 25:753–755CrossRef Wang WC, Yee S, Reinhall P (1995) Optical viscosity sensor using forward light scattering. Sensors Actuators B 25:753–755CrossRef
20.
Zurück zum Zitat Xu T, Chakrabarty K (2007) Parallel scan-like test and multiple defect diagnosis for digital microfluidic biochips. IEEE Trans on Biomedical Circuit and Systems 1(2):148–158CrossRef Xu T, Chakrabarty K (2007) Parallel scan-like test and multiple defect diagnosis for digital microfluidic biochips. IEEE Trans on Biomedical Circuit and Systems 1(2):148–158CrossRef
21.
Zurück zum Zitat Xu T, Chakrabarty K (2008) Integrated droplet routing and defect tolerance in the synthesis of digital microfluidic biochips. ACM J Emerg Technol Comput Syst 4(3):11.1–11.24, Article – II CrossRef Xu T, Chakrabarty K (2008) Integrated droplet routing and defect tolerance in the synthesis of digital microfluidic biochips. ACM J Emerg Technol Comput Syst 4(3):11.1–11.24, Article – II CrossRef
Metadaten
Titel
Distributed Scan Like Fault Detection and Test Optimization for Digital Microfluidic Biochips
verfasst von
Subhamita Mukherjee
Tuhina Samanta
Publikationsdatum
01.06.2015
Verlag
Springer US
Erschienen in
Journal of Electronic Testing / Ausgabe 3/2015
Print ISSN: 0923-8174
Elektronische ISSN: 1573-0727
DOI
https://doi.org/10.1007/s10836-015-5525-5

Neuer Inhalt