Skip to main content

2022 | OriginalPaper | Buchkapitel

Dynamic Socket Design for Transtibial Prosthesis

verfasst von : Jhon Hernández Martin, Alejandra Santos Borraez, Catalina Ríos Bustos, Fran Pérez Ortiz, Phillip Meziath Castro

Erschienen in: WITS 2020

Verlag: Springer Singapore

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Within the industry dedicated to build and adapt orthoses and prostheses, there has been a growing number of users or patients who require the use of prosthesis, for the replacement of one or several limbs (either lower or upper); for this reason, the innovation in devices and materials appears as a current need for the benefit of patients. Either for the manufacturing or adaptation of prosthetic components, along the experience, it has been evidenced that, in order to treat an amputee, the selection of the components to be used in the prosthesis is not the only aspect to take into account; consequently, one of the paramount factors is the proper management of adaptation The component with the highest relevance in the adaptation of a prosthesis is the socket. This device has been specially made in accordance with the anthropometric measures of the patient, and built using rigid, lasting compounds However, an issue arises regarding the moment when the patient, along adaptation or rehabilitation, changes his/her physical condition or stump. The previous fitting loosens and clearly depends on the suspension system to stay in position; on the other hand, if the patient’s body mass increases rather than decreases, the previously manufactured socket will not allow the use of said prosthesis Because of this, an unexplored research niche has been detected, corresponding to the design and manufacture of dynamic sockets, which can adapt to the user, depending on the change in morphology Another great field of action is the use of dynamic sockets in children.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Arnold AJ, Haworth JL, Moran VO, Abulhasan A, Steinbuch N, Kokkoni E (2020) Exploring the unmet need for technology to promote motor ability in children younger than 5 years of age: a systematic review. Arch Rehabil Res Clin Transl 2(2):100051 Arnold AJ, Haworth JL, Moran VO, Abulhasan A, Steinbuch N, Kokkoni E (2020) Exploring the unmet need for technology to promote motor ability in children younger than 5 years of age: a systematic review. Arch Rehabil Res Clin Transl 2(2):100051
2.
Zurück zum Zitat Swanson EC, McLean JB, Allyn KJ, Redd CB, Sanders JE (2018) Instrumented socket inserts for sensing interaction at the limb-socket interface. Med Eng Phys 51:111–118CrossRef Swanson EC, McLean JB, Allyn KJ, Redd CB, Sanders JE (2018) Instrumented socket inserts for sensing interaction at the limb-socket interface. Med Eng Phys 51:111–118CrossRef
3.
Zurück zum Zitat Moradi V, Sanjari MA, Saeedi H, Hajiaghaei B (2020) Experimental study of prosthesis modifications based on passive dynamic walking model: A limit cycle stability analysis. J Biomech 104:109743CrossRef Moradi V, Sanjari MA, Saeedi H, Hajiaghaei B (2020) Experimental study of prosthesis modifications based on passive dynamic walking model: A limit cycle stability analysis. J Biomech 104:109743CrossRef
4.
Zurück zum Zitat McLean JB et al (2019) Socket size adjustments in people with transtibial amputation: effects on residual limb fluid volume and limb-socket distance. Clin Biomech 63(September 2018):161–171 McLean JB et al (2019) Socket size adjustments in people with transtibial amputation: effects on residual limb fluid volume and limb-socket distance. Clin Biomech 63(September 2018):161–171
5.
Zurück zum Zitat Waterval NFJ, Brehm, Ploeger HE, Nollet F, Harlaar J (2018) Compensations in lower limb joint work during walking in response to unilateral calf muscle weakness. Gait Posture 66(October 2017):38–44 Waterval NFJ, Brehm, Ploeger HE, Nollet F, Harlaar J (2018) Compensations in lower limb joint work during walking in response to unilateral calf muscle weakness. Gait Posture 66(October 2017):38–44
6.
Zurück zum Zitat Wolf SI, Alimusaj M, Fradet L, Siegel J, Braatz F (2009) Pressure characteristics at the stump/socket interface in transtibial amputees using an adaptive prosthetic foot. Clin Biomech 24(10):860–865CrossRef Wolf SI, Alimusaj M, Fradet L, Siegel J, Braatz F (2009) Pressure characteristics at the stump/socket interface in transtibial amputees using an adaptive prosthetic foot. Clin Biomech 24(10):860–865CrossRef
7.
Zurück zum Zitat Dou P, Jia X, Suo S, Wang R, Zhang M (2006) Pressure distribution at the stump/socket interface in transtibial amputees during walking on stairs, slope and non-flat road. Clin Biomech 21(10):1067–1073CrossRef Dou P, Jia X, Suo S, Wang R, Zhang M (2006) Pressure distribution at the stump/socket interface in transtibial amputees during walking on stairs, slope and non-flat road. Clin Biomech 21(10):1067–1073CrossRef
8.
Zurück zum Zitat Boone DA et al (2013) Influence of malalignment on socket reaction moments during gait in amputees with transtibial prostheses. Gait Posture 37(4):620–626CrossRef Boone DA et al (2013) Influence of malalignment on socket reaction moments during gait in amputees with transtibial prostheses. Gait Posture 37(4):620–626CrossRef
9.
Zurück zum Zitat Lenz AL, Bush TR (2019) Evaluating shear and normal force with the use of an instrumented transtibial socket: A case study. Med Eng Phys 71:102–107CrossRef Lenz AL, Bush TR (2019) Evaluating shear and normal force with the use of an instrumented transtibial socket: A case study. Med Eng Phys 71:102–107CrossRef
10.
Zurück zum Zitat Meng Z, Wong DWC, Zhang M, Leung AKL (2020) Analysis of compression/release stabilized transfemoral prosthetic socket by finite element modelling method. Med Eng Phys xxxx Meng Z, Wong DWC, Zhang M, Leung AKL (2020) Analysis of compression/release stabilized transfemoral prosthetic socket by finite element modelling method. Med Eng Phys xxxx
11.
Zurück zum Zitat Gholizadeh H, Osman NAA, Kamyab M, Eshraghi A, Abas WABW, Azam MN (2012) Transtibial prosthetic socket pistoning: Static evaluation of Seal-In ® X5 and Dermo® Liner using motion analysis system. Clin Biomech 27(1):34–39CrossRef Gholizadeh H, Osman NAA, Kamyab M, Eshraghi A, Abas WABW, Azam MN (2012) Transtibial prosthetic socket pistoning: Static evaluation of Seal-In ® X5 and Dermo® Liner using motion analysis system. Clin Biomech 27(1):34–39CrossRef
12.
Zurück zum Zitat Kobayashi T, Orendurff MS, Zhang M, Boone DA (2013) Effect of alignment changes on sagittal and coronal socket reaction moment interactions in transtibial prostheses. J Biomech 46(7):1343–1350CrossRef Kobayashi T, Orendurff MS, Zhang M, Boone DA (2013) Effect of alignment changes on sagittal and coronal socket reaction moment interactions in transtibial prostheses. J Biomech 46(7):1343–1350CrossRef
Metadaten
Titel
Dynamic Socket Design for Transtibial Prosthesis
verfasst von
Jhon Hernández Martin
Alejandra Santos Borraez
Catalina Ríos Bustos
Fran Pérez Ortiz
Phillip Meziath Castro
Copyright-Jahr
2022
Verlag
Springer Singapore
DOI
https://doi.org/10.1007/978-981-33-6893-4_44

Neuer Inhalt