Skip to main content

2019 | OriginalPaper | Buchkapitel

3. EDM Surface Treatment: An Enhanced Biocompatible Interface

verfasst von : Amit Mahajan, Sarabjeet Singh Sidhu, Timur Ablyaz

Erschienen in: Biomaterials in Orthopaedics and Bone Regeneration

Verlag: Springer Singapore

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

This article focuses on the surface treatment of medical grade cobalt–chromium alloy (ASTM-F75) by electric discharge machining (EDM) technique. The specimen’s surfaces were modified by EDM at a different combination of its significant performance parameters such as current and pulse on time to scrutinize the sample biological behavior. The cytocompatibility test with MTT assay in HeLa cell lines was employed to analyze the in-vitro biocompatibility of samples. The results demonstrated that the EDMed surface has significantly higher competent cell viability as compared to the untreated specimen. The surface engineering at 5 A current and high pulse on time (i.e., 200 µs) was found as significant parameters to achieve a highly favorable biocompatible surface. Therefore, the surface alteration of Co–Cr medical devices via EDM can be deemed as a promising technique for enhancing the surface properties of bioimplants.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Huebsch N, Mooney DJ (2009) Inspiration and application in the evolution of biomaterials. Nature 462(7272):426–432CrossRef Huebsch N, Mooney DJ (2009) Inspiration and application in the evolution of biomaterials. Nature 462(7272):426–432CrossRef
2.
Zurück zum Zitat Long M, Rack HJ (1998) Titanium alloys in total joint replacement—a materials science perspective. Biomaterials 19:1621–1639CrossRef Long M, Rack HJ (1998) Titanium alloys in total joint replacement—a materials science perspective. Biomaterials 19:1621–1639CrossRef
3.
Zurück zum Zitat Walia B, Sarao TPS, Grewal JS (2015) Corrosion studies of thermal Sprayed HA and HA/Al2O3-TiO2 bond coating on 316L stainless steel. Trends Biomater Artif Organs 29(3):245–252 Walia B, Sarao TPS, Grewal JS (2015) Corrosion studies of thermal Sprayed HA and HA/Al2O3-TiO2 bond coating on 316L stainless steel. Trends Biomater Artif Organs 29(3):245–252
4.
Zurück zum Zitat Ristic M, Manic M, Misic D, Kosanovic M, Mitkovic M (2017) Implant material selection using expert system. FU Mech Eng 15(1):133–144CrossRef Ristic M, Manic M, Misic D, Kosanovic M, Mitkovic M (2017) Implant material selection using expert system. FU Mech Eng 15(1):133–144CrossRef
5.
Zurück zum Zitat Hyslop DJS, Abdelkader AM, Cox A, Fray DJ (2010) Electrochemical synthesis of a biomedically important Co–Cr alloy. Acta Mater 58(8):3124–3130CrossRef Hyslop DJS, Abdelkader AM, Cox A, Fray DJ (2010) Electrochemical synthesis of a biomedically important Co–Cr alloy. Acta Mater 58(8):3124–3130CrossRef
6.
Zurück zum Zitat Tarzia V, Bottio T, Testolin L, Gerosa G (2007) Extended (31 years) durability of Starr-Edwards prosthesis in mitral position. Interact Cardiovasc Thoracic Surg 6(4):570–571CrossRef Tarzia V, Bottio T, Testolin L, Gerosa G (2007) Extended (31 years) durability of Starr-Edwards prosthesis in mitral position. Interact Cardiovasc Thoracic Surg 6(4):570–571CrossRef
7.
Zurück zum Zitat Posada OM, Tate RJ, Grant MH (2015) Effects of CoCr metal wear debris generated from metal-on-metal hip implants and Co ions on human monocyte-like U937 cells. Toxicol In Vitro 29(2):271–280CrossRef Posada OM, Tate RJ, Grant MH (2015) Effects of CoCr metal wear debris generated from metal-on-metal hip implants and Co ions on human monocyte-like U937 cells. Toxicol In Vitro 29(2):271–280CrossRef
8.
Zurück zum Zitat Okazaki Y, Emiko G (2005) Comparison of metal release from various metallic biomaterials in vitro. Biomaterials 26(1):11–21CrossRef Okazaki Y, Emiko G (2005) Comparison of metal release from various metallic biomaterials in vitro. Biomaterials 26(1):11–21CrossRef
9.
Zurück zum Zitat Bains PS, Sidhu SS, Payal HS, Kaur S (2019) Magnetic field influence on surface modifications in powder mixed EDM. Silicon 11(1):415–423CrossRef Bains PS, Sidhu SS, Payal HS, Kaur S (2019) Magnetic field influence on surface modifications in powder mixed EDM. Silicon 11(1):415–423CrossRef
10.
Zurück zum Zitat Klocke F, Zeis M, Klink A, Veselovac D (2013) Technological and economical comparison of roughing strategies via milling, EDM and ECM for titanium-and nickelbased blisks. Proc CIRP 2(1):98–101 Klocke F, Zeis M, Klink A, Veselovac D (2013) Technological and economical comparison of roughing strategies via milling, EDM and ECM for titanium-and nickelbased blisks. Proc CIRP 2(1):98–101
11.
Zurück zum Zitat Kumar S, Singh R, Batish A, Singh TP (2012) Electric discharge machining of titanium and its alloys: a review. Int J Mach Mach Mater 11(1):84–111 Kumar S, Singh R, Batish A, Singh TP (2012) Electric discharge machining of titanium and its alloys: a review. Int J Mach Mach Mater 11(1):84–111
12.
Zurück zum Zitat Bains PS, Sidhu SS, Payal HS (2018) Investigation of magnetic field-assisted EDM of composites. Mater Manfact Process 33(6):670–675CrossRef Bains PS, Sidhu SS, Payal HS (2018) Investigation of magnetic field-assisted EDM of composites. Mater Manfact Process 33(6):670–675CrossRef
13.
Zurück zum Zitat Mahajan A, Sidhu SS (2017) Surface modification of metallic biomaterials for enhanced functionality: a review. Mater Technol 33(2):1–13 Mahajan A, Sidhu SS (2017) Surface modification of metallic biomaterials for enhanced functionality: a review. Mater Technol 33(2):1–13
14.
Zurück zum Zitat Mahajan A, Sidhu SS (2018) Enhancing biocompatibility of Co–Cr alloy implants via electrical discharge process. Mater Technol 33(8):1–8CrossRef Mahajan A, Sidhu SS (2018) Enhancing biocompatibility of Co–Cr alloy implants via electrical discharge process. Mater Technol 33(8):1–8CrossRef
15.
Zurück zum Zitat Bigerelle M, Anselme K, Noel B, Ruderman I, Hardouin P, loat A (2002) Improvement in the morphology of Ti-basedsurfaces: a new process to increase in vitro human osteoblast response. Biomaterials 23(7):1563–1577CrossRef Bigerelle M, Anselme K, Noel B, Ruderman I, Hardouin P, loat A (2002) Improvement in the morphology of Ti-basedsurfaces: a new process to increase in vitro human osteoblast response. Biomaterials 23(7):1563–1577CrossRef
16.
Zurück zum Zitat Peng PW, Ou KL, Lin HC, Pan YN, Wang CH (2010) Effect of electrical-discharging on formation of nanoporousbiocompatible layer on titanium. J Alloys Compd 492:625–630CrossRef Peng PW, Ou KL, Lin HC, Pan YN, Wang CH (2010) Effect of electrical-discharging on formation of nanoporousbiocompatible layer on titanium. J Alloys Compd 492:625–630CrossRef
17.
Zurück zum Zitat Mastud S, Garg M, Singh RK, Samuel J, Joshi H (2012) Experimental characterization of vibration-assisted reverse micro electrical discharge machining (EDM) for surface texturing. In: Proceeding of ASME international manufacturing science and engineering conference, pp 439–448 Mastud S, Garg M, Singh RK, Samuel J, Joshi H (2012) Experimental characterization of vibration-assisted reverse micro electrical discharge machining (EDM) for surface texturing. In: Proceeding of ASME international manufacturing science and engineering conference, pp 439–448
18.
Zurück zum Zitat Bains PS, Sidhu SS, Payal HS (2016) Study of magnetic field-assisted ED machining of metal matrix composites. Mater Manfu Processes 31(14):1889–1894CrossRef Bains PS, Sidhu SS, Payal HS (2016) Study of magnetic field-assisted ED machining of metal matrix composites. Mater Manfu Processes 31(14):1889–1894CrossRef
19.
Zurück zum Zitat Bhui AS, Singh G, Sidhu SS, Bains PS (2018) Experimental investigation of optimal ED machining parameters for Ti-6Al-4 V biomaterial. FU Mech Eng 16(3):337–345CrossRef Bhui AS, Singh G, Sidhu SS, Bains PS (2018) Experimental investigation of optimal ED machining parameters for Ti-6Al-4 V biomaterial. FU Mech Eng 16(3):337–345CrossRef
21.
Zurück zum Zitat Longster GH, Buckley T, Sikorski J, Derrick-Tovey LA (1972) Scanning electron microscope studies of red cell morphology. Vox Sang 22(2):161–170CrossRef Longster GH, Buckley T, Sikorski J, Derrick-Tovey LA (1972) Scanning electron microscope studies of red cell morphology. Vox Sang 22(2):161–170CrossRef
Metadaten
Titel
EDM Surface Treatment: An Enhanced Biocompatible Interface
verfasst von
Amit Mahajan
Sarabjeet Singh Sidhu
Timur Ablyaz
Copyright-Jahr
2019
Verlag
Springer Singapore
DOI
https://doi.org/10.1007/978-981-13-9977-0_3