Skip to main content

2015 | OriginalPaper | Buchkapitel

13. Electrochemical Biological Sensors Based on Directly Synthesized Carbon Nanotube Electrodes

verfasst von : Kenzo Maehashi, Kazuhiko Matsumoto, Yuzuru Takamura, Eiichi Tamiya

Erschienen in: Frontiers of Graphene and Carbon Nanotubes

Verlag: Springer Japan

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

We have fabricated electrochemical biological sensors based on directly synthesized carbon nanotube (CNT) electrodes. Since CNTs have a large specific surface area, the direct synthesis of CNTs on electrodes in amperometric biosensors is expected to significantly enhance electroactive surface area. Moreover, in electrochemical detections, CNT electrodes promote electron-transfer reactions on CNT surfaces. In this section, we have investigated the technology and performance of the electrochemical biosensors based on CNT electrodes and described microfluidic chips with multibiosensors based on CNT electrodes for commercialization.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Leiner MJP (1991) Luminescence chemical sensors for biomedical applications: scope and limitations. Anal Chim Acta 255:209CrossRef Leiner MJP (1991) Luminescence chemical sensors for biomedical applications: scope and limitations. Anal Chim Acta 255:209CrossRef
2.
Zurück zum Zitat Muller KM, Arndt KM, Bauer K, Pluckthun A (1998) Tandem immobilized metal-ion affinity chromatography/immunoaffinity purification of His-tagged proteins--evaluation of two anti-His-tag monoclonal antibodies. Anal Biochem 259:54CrossRef Muller KM, Arndt KM, Bauer K, Pluckthun A (1998) Tandem immobilized metal-ion affinity chromatography/immunoaffinity purification of His-tagged proteins--evaluation of two anti-His-tag monoclonal antibodies. Anal Biochem 259:54CrossRef
3.
Zurück zum Zitat Lyon LA, Musick MD, Natan MJ (1998) Colloidal au-enhanced surface plasmon resonance immunosensing. Anal Chem 70:5177CrossRef Lyon LA, Musick MD, Natan MJ (1998) Colloidal au-enhanced surface plasmon resonance immunosensing. Anal Chem 70:5177CrossRef
4.
Zurück zum Zitat Drummond T, Hill M, Barton J (2003) Electrochemical DNA sensors. Nat Biotechnol 21:1192CrossRef Drummond T, Hill M, Barton J (2003) Electrochemical DNA sensors. Nat Biotechnol 21:1192CrossRef
5.
Zurück zum Zitat Stradiotto NR, Yamanaka H, Valnice M, Zanomi B (2003) Electrochemical sensors: a powerful tool in analytical chemistry. J Braz Chem Soc 14:159CrossRef Stradiotto NR, Yamanaka H, Valnice M, Zanomi B (2003) Electrochemical sensors: a powerful tool in analytical chemistry. J Braz Chem Soc 14:159CrossRef
6.
Zurück zum Zitat Bockrath M, Cobden DH, McEuen PL, Chopra NG, Zettl A, Thess A, Smalley RE (1997) Single-electron transport in ropes of carbon nanotubes. Science 275:1922CrossRef Bockrath M, Cobden DH, McEuen PL, Chopra NG, Zettl A, Thess A, Smalley RE (1997) Single-electron transport in ropes of carbon nanotubes. Science 275:1922CrossRef
7.
Zurück zum Zitat Tans S, Verschueren A, Dekker C (1998) Room-temperature transistor based on a single carbon nanotube. Nature 393:49CrossRef Tans S, Verschueren A, Dekker C (1998) Room-temperature transistor based on a single carbon nanotube. Nature 393:49CrossRef
8.
Zurück zum Zitat Star A, Gabriel J, Bradley K, Gruner G (2003) Electronic detection of specific protein binding using nanotube FET devices. Nano Lett 3:459CrossRef Star A, Gabriel J, Bradley K, Gruner G (2003) Electronic detection of specific protein binding using nanotube FET devices. Nano Lett 3:459CrossRef
9.
Zurück zum Zitat Besteman K, Lee J, Wiertz F, Heering H, Dekker C (2003) Enzyme-coated carbon nanotubes as single-molecule biosensors. Nano Lett 3:727CrossRef Besteman K, Lee J, Wiertz F, Heering H, Dekker C (2003) Enzyme-coated carbon nanotubes as single-molecule biosensors. Nano Lett 3:727CrossRef
10.
Zurück zum Zitat Maehashi K, Katsura T, Karman K, Matsumoto K, Tamiya E (2007) Label-free protein biosensor based on aptamer-modified carbon nanotube field-effect transistors. Anal Chem 79:782CrossRef Maehashi K, Katsura T, Karman K, Matsumoto K, Tamiya E (2007) Label-free protein biosensor based on aptamer-modified carbon nanotube field-effect transistors. Anal Chem 79:782CrossRef
11.
Zurück zum Zitat Katsura T, Yamamoto Y, Maehashi K, Ohno Y, Matsumoto K (2008) High-performance carbon nanotube field-effect transistors with local electrolyte gates. Jpn J Appl Phys 47:2060CrossRef Katsura T, Yamamoto Y, Maehashi K, Ohno Y, Matsumoto K (2008) High-performance carbon nanotube field-effect transistors with local electrolyte gates. Jpn J Appl Phys 47:2060CrossRef
12.
Zurück zum Zitat Maehashi K, Matsumoto K, Takamura Y, Tamiya E (2009) Aptamer-based label-free immunosensors using carbon nanotube field-effect transistors. Electroanalysis 21:1285CrossRef Maehashi K, Matsumoto K, Takamura Y, Tamiya E (2009) Aptamer-based label-free immunosensors using carbon nanotube field-effect transistors. Electroanalysis 21:1285CrossRef
13.
Zurück zum Zitat Wang J (2004) Carbon-nanotube based electrochemical biosensors. Electroanalysis 17:7CrossRef Wang J (2004) Carbon-nanotube based electrochemical biosensors. Electroanalysis 17:7CrossRef
14.
Zurück zum Zitat Liu G, Riechers SL, Mellen MC, Lin Y (2005) Sensitive electrochemical detection of enzymatically generated thiocholine at carbon nanotube modified glassy carbon electrode. Electrochem Commun 7:1163CrossRef Liu G, Riechers SL, Mellen MC, Lin Y (2005) Sensitive electrochemical detection of enzymatically generated thiocholine at carbon nanotube modified glassy carbon electrode. Electrochem Commun 7:1163CrossRef
15.
Zurück zum Zitat Fei S, Chen J, Yao S, Deng G, He D, Kuang Y (2005) Electrochemical behavior of L-cysteine and its detection at carbon nanotube electrode modified with platinum. Anal Biochem 339:29CrossRef Fei S, Chen J, Yao S, Deng G, He D, Kuang Y (2005) Electrochemical behavior of L-cysteine and its detection at carbon nanotube electrode modified with platinum. Anal Biochem 339:29CrossRef
16.
Zurück zum Zitat Lawrence NS, Wang J (2006) Chemical adsorption of phenothiazine dyes onto carbon nanotubes: Toward the low potential detection of NADH. Electrochem Commun 8:71CrossRef Lawrence NS, Wang J (2006) Chemical adsorption of phenothiazine dyes onto carbon nanotubes: Toward the low potential detection of NADH. Electrochem Commun 8:71CrossRef
17.
Zurück zum Zitat Maehashi K, Ohno Y, Inoue K, Matsumoto K (2004) Chirality selection of single-walled carbon nanotubes by laser resonance chirality selection method. Appl Phys Lett 85:858CrossRef Maehashi K, Ohno Y, Inoue K, Matsumoto K (2004) Chirality selection of single-walled carbon nanotubes by laser resonance chirality selection method. Appl Phys Lett 85:858CrossRef
18.
Zurück zum Zitat Okuno J, Maehashi K, Matsumoto K, Kerman K, Takamura Y, Tamiya E (2007) Single-walled carbon nanotube-arrayed microelectrode chip for electrochemical analysis. Electrochem Commun 9:13CrossRef Okuno J, Maehashi K, Matsumoto K, Kerman K, Takamura Y, Tamiya E (2007) Single-walled carbon nanotube-arrayed microelectrode chip for electrochemical analysis. Electrochem Commun 9:13CrossRef
19.
Zurück zum Zitat Moreno L, Merkoci A, Alegret S, Cassou SH, Saurina J (2004) Analysis of amino acids in complex samples by using voltammetry and multivariate calibration methods Laura Morenoa. Anal Chim Acta 507:247CrossRef Moreno L, Merkoci A, Alegret S, Cassou SH, Saurina J (2004) Analysis of amino acids in complex samples by using voltammetry and multivariate calibration methods Laura Morenoa. Anal Chim Acta 507:247CrossRef
20.
Zurück zum Zitat Okuno J, Maehashi K, Kerman K, Matsumoto K, Takamura Y, Tamiya E (2007) Label-free immunosensor for prostate-specific antigen based on single-walled carbon nanotube array-modified microelectrodes. Biosens Bioelectron 22:2377CrossRef Okuno J, Maehashi K, Kerman K, Matsumoto K, Takamura Y, Tamiya E (2007) Label-free immunosensor for prostate-specific antigen based on single-walled carbon nanotube array-modified microelectrodes. Biosens Bioelectron 22:2377CrossRef
21.
Zurück zum Zitat Manz A, Graber N, Widmer HM (1990) Miniaturized total chemical analysis sytems: a novel concept for chemical sensing. Sens Actuators B1:244CrossRef Manz A, Graber N, Widmer HM (1990) Miniaturized total chemical analysis sytems: a novel concept for chemical sensing. Sens Actuators B1:244CrossRef
22.
Zurück zum Zitat Harrison DJ, Fluri K, Seiler K, Fan Z, Effenhauser CS, Manz A (1993) Micromachining a miniaturized capillary electrophoresis-based chemical analysis system on a chip. Science 261:895CrossRef Harrison DJ, Fluri K, Seiler K, Fan Z, Effenhauser CS, Manz A (1993) Micromachining a miniaturized capillary electrophoresis-based chemical analysis system on a chip. Science 261:895CrossRef
23.
Zurück zum Zitat Reyes DR, Iossifidis D, Auroux P, Manz A (2002) Micro total analysis systems. 1. introduction, theory, and technology. Anal Chem 74:2623CrossRef Reyes DR, Iossifidis D, Auroux P, Manz A (2002) Micro total analysis systems. 1. introduction, theory, and technology. Anal Chem 74:2623CrossRef
24.
Zurück zum Zitat Tsujita Y, Maehashi K, Matsumoto K, Chikae M, Takamura Y, Tamiya E (2009) Microfluidic and label-free multi-immunosensors based on carbon nanotube microelectrodes. Jpn J Appl Phys 48:06FJ02CrossRef Tsujita Y, Maehashi K, Matsumoto K, Chikae M, Takamura Y, Tamiya E (2009) Microfluidic and label-free multi-immunosensors based on carbon nanotube microelectrodes. Jpn J Appl Phys 48:06FJ02CrossRef
25.
Zurück zum Zitat Tsujita Y, Maehashi K, Matsumoto K, Chikae M, Torai S, Takamura Y, Tamiya E (2008) Carbon nanotube amperometric chips with pneumatic micropumps. Jpn J Appl Phys 47:2064CrossRef Tsujita Y, Maehashi K, Matsumoto K, Chikae M, Torai S, Takamura Y, Tamiya E (2008) Carbon nanotube amperometric chips with pneumatic micropumps. Jpn J Appl Phys 47:2064CrossRef
Metadaten
Titel
Electrochemical Biological Sensors Based on Directly Synthesized Carbon Nanotube Electrodes
verfasst von
Kenzo Maehashi
Kazuhiko Matsumoto
Yuzuru Takamura
Eiichi Tamiya
Copyright-Jahr
2015
Verlag
Springer Japan
DOI
https://doi.org/10.1007/978-4-431-55372-4_13

Neuer Inhalt