Skip to main content

2019 | OriginalPaper | Buchkapitel

EMG Map for Designing the Electrode Shape for Functional Electrical Therapy of Upper Extremities

verfasst von : Lana Popović-Maneski, Ivan Topalović

Erschienen in: Converging Clinical and Engineering Research on Neurorehabilitation III

Verlag: Springer International Publishing

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Achieving the functional grasp by electrical stimulation using surface electrodes is a demanding task. The innervations of muscles come via ulnar, radial and median nerves. The anatomy of nerve branches connecting various muscles in the forearm differs significantly between individuals. We hypothesize that the anatomical differences between the paretic and nonparetic arms are minimal. Based on this assumption we developed a method where the differences of muscle activities (EMG) between the healthy and paretic arms recorded by the 24-contact electrode within an array define the target zones to be stimulated on the affected forearm. We used special electrode where magnetic contacts allow simple change of the stimulation pads. The examiner positions the magnetic contact on the pads where the EMG differences are maximal. The stimulator delivers asynchronous stimulation to the selected pads. We proved that the method is working in stroke patients by measuring joint angles and the grasping force.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Nathan, R.H.: An FNS-based system for generating upper limb function in the C4 quadriplegic. Med. Biol. Eng. Comput. 27, 549–556 (1989)CrossRef Nathan, R.H.: An FNS-based system for generating upper limb function in the C4 quadriplegic. Med. Biol. Eng. Comput. 27, 549–556 (1989)CrossRef
2.
Zurück zum Zitat Kuhn, A., Keller, T., Micera, S., Morari, M.: Array electrode design for transcutaneous electrical stimulation: a simulation study. Med. Eng. Phys. 32, 945–951 (2009)CrossRef Kuhn, A., Keller, T., Micera, S., Morari, M.: Array electrode design for transcutaneous electrical stimulation: a simulation study. Med. Eng. Phys. 32, 945–951 (2009)CrossRef
3.
Zurück zum Zitat Popović Bijelić, A., Bijelić, G., Jorgovanović, N., Bojanić, D., Popović, M.B., Popović, D.B.: Multi field surface electrode for selective electrical stimulation. Artif. Organs 29, 448–452 (2005)CrossRef Popović Bijelić, A., Bijelić, G., Jorgovanović, N., Bojanić, D., Popović, M.B., Popović, D.B.: Multi field surface electrode for selective electrical stimulation. Artif. Organs 29, 448–452 (2005)CrossRef
4.
Zurück zum Zitat Popović, D.B., Popović, M.B.: Automatic determination of the optimal shape of a surface electrode: selective stimulation. J. Neurosci. Methods 178, 174–181 (2009)CrossRef Popović, D.B., Popović, M.B.: Automatic determination of the optimal shape of a surface electrode: selective stimulation. J. Neurosci. Methods 178, 174–181 (2009)CrossRef
6.
Zurück zum Zitat Popović-Maneski, L., Kostić, M., Keller, T., Mitrović, S., Konstantinović, L., Popović, D.B.: Multi-pad electrode for effective grasping: design. IEEE Trans. Neural Syst. Rehab. Eng. 21(4), 648–654 (2013)CrossRef Popović-Maneski, L., Kostić, M., Keller, T., Mitrović, S., Konstantinović, L., Popović, D.B.: Multi-pad electrode for effective grasping: design. IEEE Trans. Neural Syst. Rehab. Eng. 21(4), 648–654 (2013)CrossRef
7.
Zurück zum Zitat Popović-Maneski, L., Topalović, I., Jovičić, N., Dedijer, S., Konstantinović, L., Popović, D.B.: Stimulation map for control of functional grasp based on multi-channel EMG recordings. Med. Eng. Phys. 38, 1251–1259 (2016)CrossRef Popović-Maneski, L., Topalović, I., Jovičić, N., Dedijer, S., Konstantinović, L., Popović, D.B.: Stimulation map for control of functional grasp based on multi-channel EMG recordings. Med. Eng. Phys. 38, 1251–1259 (2016)CrossRef
8.
Zurück zum Zitat Popović-Maneski, L., Malešević, N., Savić, A., Popović, D.B.: Spatially distributed asynchronous stimulation delays muscle fatigue. Muscle Nerve 48, 930–937 (2013)CrossRef Popović-Maneski, L., Malešević, N., Savić, A., Popović, D.B.: Spatially distributed asynchronous stimulation delays muscle fatigue. Muscle Nerve 48, 930–937 (2013)CrossRef
9.
Zurück zum Zitat Nguyen, R., Masani, K., Micera, S., Morari, M., Popović, M.R.: Spatially distributed sequential stimulation reduces fatigue in paralyzed triceps surae muscles: a case study. Artif. Organs 35, 1174–11803 (2011)CrossRef Nguyen, R., Masani, K., Micera, S., Morari, M., Popović, M.R.: Spatially distributed sequential stimulation reduces fatigue in paralyzed triceps surae muscles: a case study. Artif. Organs 35, 1174–11803 (2011)CrossRef
11.
Zurück zum Zitat Topalović, I., Janković, M., Popović, D.B.: Validation of the acquisition system Smarting for EMG recordings with electrode array. In: Proceedings of 2nd IcETRAN, Silver Lake, Serbia, 6–9 June 2015. MEI1.3 (2015) Topalović, I., Janković, M., Popović, D.B.: Validation of the acquisition system Smarting for EMG recordings with electrode array. In: Proceedings of 2nd IcETRAN, Silver Lake, Serbia, 6–9 June 2015. MEI1.3 (2015)
Metadaten
Titel
EMG Map for Designing the Electrode Shape for Functional Electrical Therapy of Upper Extremities
verfasst von
Lana Popović-Maneski
Ivan Topalović
Copyright-Jahr
2019
DOI
https://doi.org/10.1007/978-3-030-01845-0_201

Neuer Inhalt