Empirical Mode Decomposition in Analysis of Hemodynamic Response to Static Handgrip

verfasst von : Norbert Olenderek, Gerard Cybulski, Krzysztof Krzemiński, Wiktor Niewiadomski, Anna Gąsiorowska, Anna Strasz

Erschienen in: World Congress on Medical Physics and Biomedical Engineering 2018

Verlag: Springer Singapore

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

The empirical mode decomposition (EMD) of biological signals is used to detect reaction to physiological stimuli and to identify global trends in slowly changing variables. We applied EMD to analyze hemodynamic reaction to handgrip in 9 healthy males (aged 21.3 ± 0.3 years) and 10 male patients following coronary artery bypass grafting (aged 55 ± 6 years). Subjects squeezed a dynamometer with 30% of individually determined maximal force for 3 min. The aim of the study was to check whether the application of EMD to the signals could bring any objective quantitative or qualitative measures allowing one to distinguish physiological states of healthy subjects and patients. Hemodynamic data were collected using a battery-powered, ambulatory impedance cardiography device (ReoMonitor) incorporating a single ECG channel. Heart rate (HR), R-R interval (RR), stroke volume (SV), cardiac output (CO), left ventricular ejection time (ET), pre-ejection period (PEP), maximum amplitude of the dz/dt signal (Amp), and basic chest impedance (Z0) were calculated automatically using the software earlier developed for ReoMonitor. The dedicated computer program allows to calculate and display the dynamics of basic and derivative parameters, describing the impact of systolic time intervals on RR intervals, or the relationship between them (e.g. PEP/ET). The EMD procedure was applied to identify the components of each basic hemodynamic parameter and all their derivatives. We observed the most pronounced effect of handgrip in second and third intrinsic mode functions (IMF), which particularly manifested in parameters describing the ratio of systolic time intervals to the length of RR.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Shepherd, JT., Blomqvist, GB., Lind, AR., Mithell JH., Saltin, B. Static (isometric) exercise. Supp. I. Circ Res 48(I), 179–188 (1981). Shepherd, JT., Blomqvist, GB., Lind, AR., Mithell JH., Saltin, B. Static (isometric) exercise. Supp. I. Circ Res 48(I), 179–188 (1981).
2.
Zurück zum Zitat Krzemiński K., Cybulski G., Ziemba A., Nazar K. Cardiovascular and hormonal responses to static handgrip in young and older healthy men. European Journal of Applied Physiology 112 (4), 1315–1325 (2012). Krzemiński K., Cybulski G., Ziemba A., Nazar K. Cardiovascular and hormonal responses to static handgrip in young and older healthy men. European Journal of Applied Physiology 112 (4), 1315–1325 (2012).
3.
Zurück zum Zitat Grucza, R., J F Kahn, JF., Cybulski, G., Niewiadomski, W., Stupnicka, E., Nazar, K. Cardiovascular and Sympatho-Adrenal Responses to Static Handgrip Performed With One and Two Hands” Appl Physiol Occup Physiol 59 (3), 184–188 (1989). Grucza, R., J F Kahn, JF., Cybulski, G., Niewiadomski, W., Stupnicka, E., Nazar, K. Cardiovascular and Sympatho-Adrenal Responses to Static Handgrip Performed With One and Two Hands” Appl Physiol Occup Physiol 59 (3), 184–188 (1989).
4.
Zurück zum Zitat Grucza, R., Smorawski, J., Cybulski, G., Niewiadomski, W., Kahn, JF., Kapitaniak, B., Monod, H. Cardiovascular response to static handgrip in trained and untrained men. Eur J Appl Physiol 62, 337–341 (1991). Grucza, R., Smorawski, J., Cybulski, G., Niewiadomski, W., Kahn, JF., Kapitaniak, B., Monod, H. Cardiovascular response to static handgrip in trained and untrained men. Eur J Appl Physiol 62, 337–341 (1991).
5.
Zurück zum Zitat Krzemiński, K., Cybulski, G., Nazar K.. Relationships between plasma adrenomedullin concentration and systolic time intervals during static handgrip in patients with heart failure. Clinical Physiology and Functional Imaging. 29(2), 114–22 (2009). Krzemiński, K., Cybulski, G., Nazar K.. Relationships between plasma adrenomedullin concentration and systolic time intervals during static handgrip in patients with heart failure. Clinical Physiology and Functional Imaging. 29(2), 114–22 (2009).
6.
Zurück zum Zitat Bilinska M., Kosydar-Piechna M., Gasiorowska A., Mikulski T., Piotrowski W., Nazar K., Piotrowicz R. Influence of dynamic training on hemodynamic, neurohormonal responses to static exercise and on inflammatory markers in patients after coronary artery bypass grafting. Circ J. 74(12), 2598–604 (2010). Bilinska M., Kosydar-Piechna M., Gasiorowska A., Mikulski T., Piotrowski W., Nazar K., Piotrowicz R. Influence of dynamic training on hemodynamic, neurohormonal responses to static exercise and on inflammatory markers in patients after coronary artery bypass grafting. Circ J. 74(12), 2598–604 (2010).
7.
Zurück zum Zitat Huang, N. E., Shen, Z., Long, S. R., Wu, M. C., Shih, H. H., Zheng, Q., Yen, N. C., Tung, C. C., Liu, H. H. (1998). The Empirical Mode Decomposition and the Hilbert Spectrum for Nonlinear and Nonstationary Time Series Analysis. Proceedings of the Royal Society of London A. 454, 903–995 (1971). Huang, N. E., Shen, Z., Long, S. R., Wu, M. C., Shih, H. H., Zheng, Q., Yen, N. C., Tung, C. C., Liu, H. H. (1998). The Empirical Mode Decomposition and the Hilbert Spectrum for Nonlinear and Nonstationary Time Series Analysis. Proceedings of the Royal Society of London A. 454, 903–995 (1971).
8.
Zurück zum Zitat Cybulski, G., Książkiewicz, A., Łukasik, W., Niewiadomski, W., Pałko T. Ambulatory monitoring device for central hemodynamics and ECG signals recording on PCMCIA flash memory cards, Computers in Cardiology 1995, IEEE, Vienna, Austria, September 10–13, Computers in Cardiology 1995, IEEE. 1995, pp. 505–7 (1995). Cybulski, G., Książkiewicz, A., Łukasik, W., Niewiadomski, W., Pałko T. Ambulatory monitoring device for central hemodynamics and ECG signals recording on PCMCIA flash memory cards, Computers in Cardiology 1995, IEEE, Vienna, Austria, September 10–13, Computers in Cardiology 1995, IEEE. 1995, pp. 505–7 (1995).
9.
Zurück zum Zitat Cybulski G. Computer method for automatic determination of stroke volume using impedance cardiography signals, Acta Physiologica Polonica, 39 (5–6), 494–503 (1988). Cybulski G. Computer method for automatic determination of stroke volume using impedance cardiography signals, Acta Physiologica Polonica, 39 (5–6), 494–503 (1988).
11.
Zurück zum Zitat Cybulski, G., Ziółkowska, E., Kodrzycka, A., Niewiadomski, W., Sikora, K., Książkiewicz, A., Łukasik, W., Pałko T. Application of Impedance Cardiography Ambulatory Monitoring System for Analysis of Central Hemodynamics in Healthy Man and Arrhythmia Patients. Computers in Cardiology 1997, IEEE., 509–12 (1997). Cybulski, G., Ziółkowska, E., Kodrzycka, A., Niewiadomski, W., Sikora, K., Książkiewicz, A., Łukasik, W., Pałko T. Application of Impedance Cardiography Ambulatory Monitoring System for Analysis of Central Hemodynamics in Healthy Man and Arrhythmia Patients. Computers in Cardiology 1997, IEEE., 509–12 (1997).
12.
Zurück zum Zitat Cybulski G., Michalak E., Koźluk E., Piątkowska A., Niewiadomski W., Stroke volume and systolic time intervals: beat-to-beat comparison between echocardiography and ambulatory impedance cardiography in supine and tilted positions, Medical and Biological Engineering and Computing, 42, 707–711 (2004). Cybulski G., Michalak E., Koźluk E., Piątkowska A., Niewiadomski W., Stroke volume and systolic time intervals: beat-to-beat comparison between echocardiography and ambulatory impedance cardiography in supine and tilted positions, Medical and Biological Engineering and Computing, 42, 707–711 (2004).
Metadaten
Titel
Empirical Mode Decomposition in Analysis of Hemodynamic Response to Static Handgrip
verfasst von
Norbert Olenderek
Gerard Cybulski
Krzysztof Krzemiński
Wiktor Niewiadomski
Anna Gąsiorowska
Anna Strasz
Copyright-Jahr
2019
Verlag
Springer Singapore
DOI
https://doi.org/10.1007/978-981-10-9038-7_87

Neuer Inhalt