Skip to main content
Top

2016 | OriginalPaper | Chapter

A New Scheme for Determination of Respiration Rate in Human Being Using MEMS Based Capacitive Pressure Sensor

Authors : Madhurima Chattopadhyay, Deborshi Chakraborty

Published in: Next Generation Sensors and Systems

Publisher: Springer International Publishing

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

Monitoring respiration rate in everyday life enables an early detection of the diseases and disorders that can suddenly appear as a life threatening episode. Respiratory Rate (RR) is defined as the number of breaths per minute and is a very important physiological parameter to be monitored in people both in healthy and critical condition, as it gives meaningful information regarding their respiratory system performance as well as condition. A typical RR for adult human being at rest is 12–20 and its corresponding frequency is 0.2 Hz approximately. During recovery from surgical anesthesia, a μ-opioid agonists used for pain control can slow down RR leading to bradypnea (RR < 12) or even apnea (cessation of respiration for an indeterminate period), while airway obstructions like asthma, emphysema and COPD. In all these cases long term monitoring can extend the capabilities of healthcare providers but only constraint lies with the performance reliability along with the economic barrier. In this chapter, a MEMS based capacitive nasal sensor system for measuring Respiration Rate (RR) of human being is developed. In order to develop such system, two identical arrays of diaphragms based MEMS capacitive nasal sensors are designed and virtually fabricated. A proposed schematic of the system consists of signal conditioning circuitry alongwith the sensors, is described here. In this proposed scheme, the two identical sensor arrays are mounted below Right Nostril (RN) and Left Nostril (LN), in such a way that the nasal airflow during inspiration and expiration impinge on the sensor diaphragms. Due to nasal airflow, the designed square diaphragm of the sensor is being deflected and thus induces a corresponding change in the original capacitance value. This change in capacitance value is be detected by a CMOS based clocked capacitance-to-voltage converter. The capacitive type MEMS sensors often suffer from stray and standing capacitive effect, in order to nullify this precision interface with MEMS capacitive pressure sensor, followed by an amplifier and a differential cyclic ADC is implemented to digitize the pressure information. The designed MEMS based capacitive nasal sensors is capable of identifying normal RR (18.5 ± 1.5 bpm) of human being. The design of sensors and its characteristics analysis are performed on a FEA/BEA based virtual simulation platform.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference J. Milic-Emili, Recent advances in clinical assessment of control of breathing. Lung 160, 1–17 (1982) J. Milic-Emili, Recent advances in clinical assessment of control of breathing. Lung 160, 1–17 (1982)
2.
go back to reference D. Moffett, S. Moffett, C. Schauf, Human Physiology, 2nd edn, Ch. 13 and 16. (Wm. C. Brown Publishers, Dubuque, 1993) D. Moffett, S. Moffett, C. Schauf, Human Physiology, 2nd edn, Ch. 13 and 16. (Wm. C. Brown Publishers, Dubuque, 1993)
3.
go back to reference I. Prkic et al., Pontine μ-opioid receptors mediate bradypnea caused by intravenous remifentanil infusions at clinically relevant concentrations in dogs. J. Neurophysiol. 108, 2430–2441 (2012) I. Prkic et al., Pontine μ-opioid receptors mediate bradypnea caused by intravenous remifentanil infusions at clinically relevant concentrations in dogs. J. Neurophysiol. 108, 2430–2441 (2012)
4.
go back to reference S.S. Weigt, M. Abrazado, E.C. Kleerup, D.P. Tashkin, C.B. Cooper, Time course and degree of hyperinflation with metronomepaced tachypnea in COPD patients. COPD 5(5), 298–304 (2008). doi: 10.1080/15412550802363428 S.S. Weigt, M. Abrazado, E.C. Kleerup, D.P. Tashkin, C.B. Cooper, Time course and degree of hyperinflation with metronomepaced tachypnea in COPD patients. COPD 5(5), 298–304 (2008). doi: 10.​1080/​1541255080236342​8
5.
go back to reference M. Folke, L. Cernerud, M. Ekstrom, B. Hok, Critical review of non-invasive respiratory monitoring in medical care. Med. Biol. Eng. Comput. 41, 377–383 (2003)CrossRef M. Folke, L. Cernerud, M. Ekstrom, B. Hok, Critical review of non-invasive respiratory monitoring in medical care. Med. Biol. Eng. Comput. 41, 377–383 (2003)CrossRef
6.
go back to reference R. Farre, J.M. Montserrat, D. Navajas, Noninvasive monitoring of respiratory mechanics during sleep. Eur. Respir. J. 24, 1052–1060 (2004)CrossRef R. Farre, J.M. Montserrat, D. Navajas, Noninvasive monitoring of respiratory mechanics during sleep. Eur. Respir. J. 24, 1052–1060 (2004)CrossRef
7.
go back to reference H. Kawai, The piezoelectricity of polyvinylidene fluoride. J. Appl. Phys. 8, 73–77 (1969) H. Kawai, The piezoelectricity of polyvinylidene fluoride. J. Appl. Phys. 8, 73–77 (1969)
8.
go back to reference J. Siivola, New non-invasive piezoelectric transducer for recording of respiration, heart rate and body movements. Med. Bio. Eng. Comp. 27, 423–424 (1989) J. Siivola, New non-invasive piezoelectric transducer for recording of respiration, heart rate and body movements. Med. Bio. Eng. Comp. 27, 423–424 (1989)
9.
go back to reference S. Choi, Z. Jiang, A novel wearable sensor device with conductive fabric and PVDF film for monitoring cardiorespiratory signals. Sens. Actuators A 128, 317–326 (2006)CrossRef S. Choi, Z. Jiang, A novel wearable sensor device with conductive fabric and PVDF film for monitoring cardiorespiratory signals. Sens. Actuators A 128, 317–326 (2006)CrossRef
10.
go back to reference J.H. Oum, S.E. Lee, D.-W. Kim, S. Hong, Non-contact heartbeat and respiration detector using capacitive sensor with Colpitts oscillator. Electron. Lett. 44(2) (2008) J.H. Oum, S.E. Lee, D.-W. Kim, S. Hong, Non-contact heartbeat and respiration detector using capacitive sensor with Colpitts oscillator. Electron. Lett. 44(2) (2008)
11.
go back to reference S.H. Nam, T.G. Yim, C.Y. Ryu, S.C. Shin, J.H. Kang, S. Kim, The preliminary study of unobtrusive respiratory monitoring for e-health, in Proceedings of IEEE 27th Annual Conference on Engineering and Medical Biology, Shanghai, China, 1–4 Sep 2005 S.H. Nam, T.G. Yim, C.Y. Ryu, S.C. Shin, J.H. Kang, S. Kim, The preliminary study of unobtrusive respiratory monitoring for e-health, in Proceedings of IEEE 27th Annual Conference on Engineering and Medical Biology, Shanghai, China, 1–4 Sep 2005
12.
go back to reference P. Varady, T. Micsik, S. Benedek, Z. Benyó, A nobel method for the detection of apnea and hypopnea events in respiration signals. IEEE Trans. Biomed. Eng. 49, 936–942 (2002)CrossRef P. Varady, T. Micsik, S. Benedek, Z. Benyó, A nobel method for the detection of apnea and hypopnea events in respiration signals. IEEE Trans. Biomed. Eng. 49, 936–942 (2002)CrossRef
13.
go back to reference M. Coyle, Ambulatory cardiopulmonary data capture, in Proceedings of 2nd Annual International IEEE-EMBS Conference Microtechnologies in Medicine and Biology, Madison, WI, May 2002, pp. 297–300 M. Coyle, Ambulatory cardiopulmonary data capture, in Proceedings of 2nd Annual International IEEE-EMBS Conference Microtechnologies in Medicine and Biology, Madison, WI, May 2002, pp. 297–300
15.
go back to reference H. Saito, M. Nishimura, E. Shibuya, H. Makita, I. Tsujino, K. Miyamoto, Y. Kawakami, Tissue hypoxia in sleep apnea syndrome assessed by uric acid and adenosine. Chest 122(5), 1686–1694 (2002)CrossRef H. Saito, M. Nishimura, E. Shibuya, H. Makita, I. Tsujino, K. Miyamoto, Y. Kawakami, Tissue hypoxia in sleep apnea syndrome assessed by uric acid and adenosine. Chest 122(5), 1686–1694 (2002)CrossRef
16.
go back to reference P. Fathizadeh, W.C. Shoemaker, C.C.J. Wo, J. Colombo, Autonomic activity in trauma patients based on variability of heart rate and respiratory rate. Crit. Care Med. 32(6), 1420–1421 (2004)CrossRef P. Fathizadeh, W.C. Shoemaker, C.C.J. Wo, J. Colombo, Autonomic activity in trauma patients based on variability of heart rate and respiratory rate. Crit. Care Med. 32(6), 1420–1421 (2004)CrossRef
17.
go back to reference Joanna Briggs Institute, Vital Sign, vol. 3, no. 3, 1999 Joanna Briggs Institute, Vital Sign, vol. 3, no. 3, 1999
18.
go back to reference T. Kondo, T. Uhlig, P. Pemberton, P.D. Sly, Laser monitoring of chest wall displacement. Eur. Respir. J. 10, 1865–1869 (1997) T. Kondo, T. Uhlig, P. Pemberton, P.D. Sly, Laser monitoring of chest wall displacement. Eur. Respir. J. 10, 1865–1869 (1997)
19.
go back to reference Y. Xiao, C. Li, J. Lin, A portable noncontact heartbeat and respiration monitoring system using 5-GHz radar. IEEE Sens. J 7(7) (2007) Y. Xiao, C. Li, J. Lin, A portable noncontact heartbeat and respiration monitoring system using 5-GHz radar. IEEE Sens. J 7(7) (2007)
20.
go back to reference M. Uenoyama, T. Matsui, K. Yamada, S. Suzuki, B. Takase, S. Suzuki, M. Ishihara, M. Kawakami, Non-contact respiratory monitoring system using a ceiling-attached microwave antenna. Med. Bio. Eng. Comput. 44, 835–840 (2006)CrossRef M. Uenoyama, T. Matsui, K. Yamada, S. Suzuki, B. Takase, S. Suzuki, M. Ishihara, M. Kawakami, Non-contact respiratory monitoring system using a ceiling-attached microwave antenna. Med. Bio. Eng. Comput. 44, 835–840 (2006)CrossRef
21.
go back to reference A.D. Droitcoour, Non-contact measurement of heart and respiration rates with a single-chip microwave Doppler radar. Ph.D. dissertation, Stanford University, Stanford, CA, June 2006 A.D. Droitcoour, Non-contact measurement of heart and respiration rates with a single-chip microwave Doppler radar. Ph.D. dissertation, Stanford University, Stanford, CA, June 2006
22.
go back to reference H. Aoki, K. Koshiji, Non-contact respiration monitoring method for screening sleep respiratory disturbance using slit light pattern projection, in IFMBE Proceedings of World Congress Medical Physics and Biomedical Engineering, vol. 2, Track 06 (2006) H. Aoki, K. Koshiji, Non-contact respiration monitoring method for screening sleep respiratory disturbance using slit light pattern projection, in IFMBE Proceedings of World Congress Medical Physics and Biomedical Engineering, vol. 2, Track 06 (2006)
23.
go back to reference S.D. Min, D.J. Yoon, S.W. Yoon, Y.H. Yun, M. Lee, A study on a non-contacting respiration signal monitoring system using Doppler ultrasound. Med. Bio. Eng. Comput. 45(11), 1113–1119 (2007)CrossRef S.D. Min, D.J. Yoon, S.W. Yoon, Y.H. Yun, M. Lee, A study on a non-contacting respiration signal monitoring system using Doppler ultrasound. Med. Bio. Eng. Comput. 45(11), 1113–1119 (2007)CrossRef
24.
go back to reference P. Corbishley, E. Rodríguez-Villegas, Breathing detection: towards a miniaturized, wearable, battery-operated monitoring system. IEEE Trans. Biomed. Eng. 55(1) 2008 P. Corbishley, E. Rodríguez-Villegas, Breathing detection: towards a miniaturized, wearable, battery-operated monitoring system. IEEE Trans. Biomed. Eng. 55(1) 2008
25.
go back to reference A. Sharma, Modelling of a pull-in voltage and touch point pressure for MEMS capacitive transduces with square diaphragm. Ph.D. thesis, Kurukshetra University, Kurukshetra, July 2008 A. Sharma, Modelling of a pull-in voltage and touch point pressure for MEMS capacitive transduces with square diaphragm. Ph.D. thesis, Kurukshetra University, Kurukshetra, July 2008
26.
go back to reference Roopa et al., Idetification of different respiratory rate by a piezo polymer based nasal sensor. IEEE xplore. ISBN:978-1-4673-4642-9/13 Roopa et al., Idetification of different respiratory rate by a piezo polymer based nasal sensor. IEEE xplore. ISBN:978-1-4673-4642-9/13
27.
go back to reference J. Milic-Emili, Recent advances in clinical assessment of control of breathing. Lung 160, 1–17 J. Milic-Emili, Recent advances in clinical assessment of control of breathing. Lung 160, 1–17
28.
go back to reference H. Kawai, Charge-Based capacitive sensor array for CMOS-based laboratory-on-chip applications. 8(4) (2008) H. Kawai, Charge-Based capacitive sensor array for CMOS-based laboratory-on-chip applications. 8(4) (2008)
Metadata
Title
A New Scheme for Determination of Respiration Rate in Human Being Using MEMS Based Capacitive Pressure Sensor
Authors
Madhurima Chattopadhyay
Deborshi Chakraborty
Copyright Year
2016
DOI
https://doi.org/10.1007/978-3-319-21671-3_7