A Simple Design of Sterilizer Equipment for Infant Incubator Using Ultraviolet Germicidal Lamps

Authors : Mamurotun, Indah Nursyamsi Handayani, Nur Hasanah Ahniar, Catharine Bernadette

Published in: Proceedings of the 1st International Conference on Electronics, Biomedical Engineering, and Health Informatics

Publisher: Springer Singapore

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

Infant incubator is an electromedical device used to treatment for a newborn which has the possibility to become a place of spread infection. Therefore, this study aims to design a simple infant incubator sterilizer as an effort to reduce the level of nosocomial infection in the neonatal intensive care unit. The simple design of infant incubator sterilizer has been made using UV germicidal lamps, arduino mega, remote control, and equipped with a sterilization time setting. The device was tested under laboratory conditions, with observational parameters consist of sterilization time, a display showing the countdown time of sterilization and the hour meter of the ultraviolet lamp, as well as remote testing, to turn on/off the device. Furthermore, the effectiveness of sterilization was tested on three types of gram-positive bacteria namely Escherichia coli, Staphylococcus aureus, and Bacillus cereus with sterilization time variations of 30, 60, 90 and 120 min. The result of this research is a prototype of sterilizer equipment using an ultraviolet germicidal lamp that can be applied to infant incubators. The effectiveness of sterilization using this equipment showed a trend gradually decrease the number of bacteria.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Rutala WA, Weber DJ (2013) Disinfection and sterilization in healthcare facilities. Bennett Brachman’s Hosp Infect, 6th edn Rutala WA, Weber DJ (2013) Disinfection and sterilization in healthcare facilities. Bennett Brachman’s Hosp Infect, 6th edn
2.
go back to reference Christina N, Ioanna P, George L, Konstantinos T, Georgios S (2015) Risk factors for nosocomial infections in neonatal intensive care units (NICU). Heal Sci J 9(2) Christina N, Ioanna P, George L, Konstantinos T, Georgios S (2015) Risk factors for nosocomial infections in neonatal intensive care units (NICU). Heal Sci J 9(2)
3.
go back to reference Fattorini M, Buonocore G, Lenzi D, Burgassi S, Cardaci RMR, Biermann KP et al (2018) Public health since the beginning: neonatal incubators safety in a clinical setting. J Infect Public Health [Internet] 11(6):788–792CrossRef Fattorini M, Buonocore G, Lenzi D, Burgassi S, Cardaci RMR, Biermann KP et al (2018) Public health since the beginning: neonatal incubators safety in a clinical setting. J Infect Public Health [Internet] 11(6):788–792CrossRef
4.
go back to reference Alkharasani MFT (2014) Bacterial contamination of new born incubator for delivery in Al-Zahraa teaching hospital in Al-Najaf Al-Ashraf province. Int J Innov Res Sci Eng Technol 3(2):9447–9449 Alkharasani MFT (2014) Bacterial contamination of new born incubator for delivery in Al-Zahraa teaching hospital in Al-Najaf Al-Ashraf province. Int J Innov Res Sci Eng Technol 3(2):9447–9449
5.
go back to reference Khan HA, Baig FK, Mehboob R (2017) Nosocomial infections: epidemiology, prevention, control and surveillance. Asian Pac J Trop Biomed [Internet] 7(5):478–482CrossRef Khan HA, Baig FK, Mehboob R (2017) Nosocomial infections: epidemiology, prevention, control and surveillance. Asian Pac J Trop Biomed [Internet] 7(5):478–482CrossRef
6.
go back to reference Morillo-García Á, Aldana-Espinal JM, Olry de Labry-Lima A, Valencia-Martín R, López-Márquez R, Loscertales-Abril M et al (2015) Hospital costs associated with nosocomial infections in a pediatric intensive care unit. Gac Sanit [Internet] 29(4):282–287 Morillo-García Á, Aldana-Espinal JM, Olry de Labry-Lima A, Valencia-Martín R, López-Márquez R, Loscertales-Abril M et al (2015) Hospital costs associated with nosocomial infections in a pediatric intensive care unit. Gac Sanit [Internet] 29(4):282–287
7.
go back to reference Choudhary R, Bandla S (2012) Ultraviolet pasteurization for food industry. Int J Food Sci Nutr Eng 2(1):12–15CrossRef Choudhary R, Bandla S (2012) Ultraviolet pasteurization for food industry. Int J Food Sci Nutr Eng 2(1):12–15CrossRef
8.
go back to reference Levetin E, Shaughnessy R, Rogers CA, Scheir R (2001) Effectiveness of germicidal UV radiation for reducing fungal contamination within air-handling units. Appl Environ Microbiol 67(8):3712–3715CrossRef Levetin E, Shaughnessy R, Rogers CA, Scheir R (2001) Effectiveness of germicidal UV radiation for reducing fungal contamination within air-handling units. Appl Environ Microbiol 67(8):3712–3715CrossRef
9.
go back to reference Welch D, Buonanno M, Grilj V, Shuryak I, Crickmore C, Bigelow AW et al (2018) Far-UVC light: a new tool to control the spread of airborne-mediated microbial diseases. Sci Rep [Internet] 8(1):1–7 Welch D, Buonanno M, Grilj V, Shuryak I, Crickmore C, Bigelow AW et al (2018) Far-UVC light: a new tool to control the spread of airborne-mediated microbial diseases. Sci Rep [Internet] 8(1):1–7
10.
go back to reference Namala B, Shivashankar S, Harikrishna E, Swetha M (2017) Design, development and fabrication of batch type continuous UV-C light system for food products. J Pharmacogn Phytochem JPP 6(4):2078–2081 Namala B, Shivashankar S, Harikrishna E, Swetha M (2017) Design, development and fabrication of batch type continuous UV-C light system for food products. J Pharmacogn Phytochem JPP 6(4):2078–2081
11.
go back to reference Bentancor M, Vidal S (2018) Programmable and low-cost ultraviolet room disinfection device. HardwareX [Internet] Bentancor M, Vidal S (2018) Programmable and low-cost ultraviolet room disinfection device. HardwareX [Internet]
12.
go back to reference Bokulich NA, Mills DA, Underwood MA (2013) Surface microbes in the neonatal intensive care unit: changes with routine cleaning and over time. J Clin Microbiol 51(8):2617–2624CrossRef Bokulich NA, Mills DA, Underwood MA (2013) Surface microbes in the neonatal intensive care unit: changes with routine cleaning and over time. J Clin Microbiol 51(8):2617–2624CrossRef
13.
go back to reference Anderson DJ, Gergen MF, Smathers E, Sexton DJ, Chen LF, Weber DJ et al (2013) Decontamination of targeted pathogens from patient rooms using an automated ultraviolet-C-emitting device. Infect Control Hosp Epidemiol 34(5):466–471CrossRef Anderson DJ, Gergen MF, Smathers E, Sexton DJ, Chen LF, Weber DJ et al (2013) Decontamination of targeted pathogens from patient rooms using an automated ultraviolet-C-emitting device. Infect Control Hosp Epidemiol 34(5):466–471CrossRef
14.
go back to reference Messina G, Burgassi S, Messina D, Montagnani V, Cevenini G (2015) A new UV-LED device for automatic disinfection of stethoscope membranes. Am J Infect Control [Internet] 43(10):e61–e66CrossRef Messina G, Burgassi S, Messina D, Montagnani V, Cevenini G (2015) A new UV-LED device for automatic disinfection of stethoscope membranes. Am J Infect Control [Internet] 43(10):e61–e66CrossRef
Metadata
Title
A Simple Design of Sterilizer Equipment for Infant Incubator Using Ultraviolet Germicidal Lamps
Authors
Mamurotun
Indah Nursyamsi Handayani
Nur Hasanah Ahniar
Catharine Bernadette
Copyright Year
2021
Publisher
Springer Singapore
DOI
https://doi.org/10.1007/978-981-33-6926-9_31