Abstract

Imaging systems employing X-rays (such a 2D projectional radiography, computed tomography, and fluoroscopy) are widely used in medicine to aid in surgical planning, intervention, and follow up. Visualization of medical devices using these techniques relies on differences in x-ray absorption between the medical device and the surrounding tissue. The amount of absorption of a given device is largely a function of its cross-sectional dimensions, density, and atomic properties. Consequently, imaging of relatively small devices, like stents, made of a low-density material, like magnesium, can be very challenging. The aim of this study is to quantify the relative radiopacities of key absorbable metal alloy systems, determine the influence of magnesium alloy composition on radiopacity, and estimate the diameters at which wires are no longer visible under typical clinical conditions. This is accomplished by producing wires from five different magnesium alloys, a zinc alloy, and an iron alloy, in sizes ranging from 0.2 to 1.0 mm diameter, and imaging on a clinical x-ray system.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference J. Rosch, F. Keller and J. Kaufman, “The Birth, Early Years, and Future of Interventional Radiology,” Journal of Vascular Interventional Radiology, vol. 14, pp. 841–853, 2003.CrossRef J. Rosch, F. Keller and J. Kaufman, “The Birth, Early Years, and Future of Interventional Radiology,” Journal of Vascular Interventional Radiology, vol. 14, pp. 841–853, 2003.CrossRef
2.
go back to reference H. Chen, M. Rogalski and J. Anker, “Advances in functional X-ray imaging techniques and contrast agents,” Physical Chemistry Chemical Physics, no. 39, 2012 H. Chen, M. Rogalski and J. Anker, “Advances in functional X-ray imaging techniques and contrast agents,” Physical Chemistry Chemical Physics, no. 39, 2012
3.
go back to reference S. A. M. Tofail, J. M. Carlson, A. A. Gandhi, J. Butler, P. Tiernan and L. O’Donoghue, “Nickel-titanium-rare earth alloy and method of processing the alloy”. USA Patent 8,440,031 B2, 2013 S. A. M. Tofail, J. M. Carlson, A. A. Gandhi, J. Butler, P. Tiernan and L. O’Donoghue, “Nickel-titanium-rare earth alloy and method of processing the alloy”. USA Patent 8,440,031 B2, 2013
4.
go back to reference X.-m. Li and e. al, “Evaluation of peripheral artery stent with 64-slice multi-detector row CT angiography: prospective comparison with digital subtraction angiography,” European Journal of Radiology, vol. 75, no. 1, pp. 98–103, 2010 X.-m. Li and e. al, “Evaluation of peripheral artery stent with 64-slice multi-detector row CT angiography: prospective comparison with digital subtraction angiography,” European Journal of Radiology, vol. 75, no. 1, pp. 98–103, 2010
5.
go back to reference A. Kastrati, J. Mehilli and et al, “Intracoronary Stenting and Angiographic Results,” Circulation, vol. 103, pp. 2816–2821, 2001. A. Kastrati, J. Mehilli and et al, “Intracoronary Stenting and Angiographic Results,” Circulation, vol. 103, pp. 2816–2821, 2001.
6.
go back to reference R. Noad, C. Hanratty and S. Walsh, “Clinical Impact of Stent Design,” Interventional Cardiology Review, vol. 9, no. 2, pp. 89–93, 2014.CrossRef R. Noad, C. Hanratty and S. Walsh, “Clinical Impact of Stent Design,” Interventional Cardiology Review, vol. 9, no. 2, pp. 89–93, 2014.CrossRef
7.
go back to reference G. Rajah, S. Narayanan and L. Rangel-Castilla, “Update on flow diverters for the endovascular,” Neurosurgical Focus, vol. 42, no. 6, 2017. G. Rajah, S. Narayanan and L. Rangel-Castilla, “Update on flow diverters for the endovascular,” Neurosurgical Focus, vol. 42, no. 6, 2017.
8.
go back to reference P. Maier, A. Steinacker, B. Clausius and N. Hort, “Influence of Solution Heat Treatment on the Microstructure Hardness and Stress Corrosion Behavior of Extruded Resoloy(R),” JOM, pp. 1870–1879, 2020 P. Maier, A. Steinacker, B. Clausius and N. Hort, “Influence of Solution Heat Treatment on the Microstructure Hardness and Stress Corrosion Behavior of Extruded Resoloy(R),” JOM, pp. 1870–1879, 2020
9.
go back to reference A. Griebel, “An in vitro and in vivo characterization of fine WE43B magnesium wire with varied thermomechanical processing conditions,” Journal of Biomedical Materials Research Part B: Applied Biomaterials, 2017 A. Griebel, “An in vitro and in vivo characterization of fine WE43B magnesium wire with varied thermomechanical processing conditions,” Journal of Biomedical Materials Research Part B: Applied Biomaterials, 2017
10.
go back to reference M. Stekker, N. Hort, F. Feyerabend, E. Hoffmann, M. Hoffmann and R. Horres, “Resorbable stents which contain a magnesium alloy”. USA Patent 9522219 B2, 2016 M. Stekker, N. Hort, F. Feyerabend, E. Hoffmann, M. Hoffmann and R. Horres, “Resorbable stents which contain a magnesium alloy”. USA Patent 9522219 B2, 2016
11.
go back to reference Y. Zheng, X. Gu and F. Witte, “Biodegradable Metals,” Materials Science and Engineering R, vol. 77, pp. 1–34, 2015CrossRef Y. Zheng, X. Gu and F. Witte, “Biodegradable Metals,” Materials Science and Engineering R, vol. 77, pp. 1–34, 2015CrossRef
12.
go back to reference M. Sikora-Jasinska, “Fabrication, mechanical properties and in vitro degradation behavior of newly developed Zn-Ag alloys for degradable implant applications,” Materials Science and Engineering: C, pp. 1170–1181, 2017 M. Sikora-Jasinska, “Fabrication, mechanical properties and in vitro degradation behavior of newly developed Zn-Ag alloys for degradable implant applications,” Materials Science and Engineering: C, pp. 1170–1181, 2017
13.
go back to reference J. Schaffer, “Cold drawn bioabsorbable ferrous and ferrous composite wires: An evaluation of in vitro vascular cytocompatibility,” Acta Biomaterialia, pp. 8574–8584, 2013 J. Schaffer, “Cold drawn bioabsorbable ferrous and ferrous composite wires: An evaluation of in vitro vascular cytocompatibility,” Acta Biomaterialia, pp. 8574–8584, 2013
14.
go back to reference Sonnow, “Biodegradable magnesium Herbert screw – image quality and artifacts with radiography, CT and MRI,” BMC Medical Imaging, 2017 Sonnow, “Biodegradable magnesium Herbert screw – image quality and artifacts with radiography, CT and MRI,” BMC Medical Imaging, 2017
15.
go back to reference J. Espiritu, J. Seitz and M. Meier, “The performance of Mg-based implants in MRI: a systematic review,” in Updates in Bioabsorbable Metals, Virtual, 2020 J. Espiritu, J. Seitz and M. Meier, “The performance of Mg-based implants in MRI: a systematic review,” in Updates in Bioabsorbable Metals, Virtual, 2020
16.
go back to reference ASTM International, F640: Standard Test Methods for Determining Radiopacity for Medical Use, 2012 ASTM International, F640: Standard Test Methods for Determining Radiopacity for Medical Use, 2012
Metadata
Title
Absorbable Wire Radiopacity: Influence of Composition and Size on X-ray Visibility
Authors
Adam J. Griebel
Aubrey L. Ehle
Jeremy E. Schaffer
Copyright Year
2021
DOI
https://doi.org/10.1007/978-3-030-65528-0_17

Premium Partners