Skip to main content
Top

2025 | OriginalPaper | Chapter

Advancements in Hygrothermal Monitoring: A Comparative Study of Sensor Reliability and Installation Strategies in Construction Elements

Authors : Simone Panico, Marco Larcher, Riccardo Pinotti, Giordano Miori, Paola Brugnara, Daniel Herrera-Avellanosa

Published in: Proceedings of the RILEM Spring Convention and Conference 2024

Publisher: Springer Nature Switzerland

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

The prevention of moisture related damages in construction is extremely important to ensure the durability of buildings, to save resources in their management and to ensure safe and healthy environments for occupants. The assessment of the internal hygrothermal conditions of construction elements using real time monitoring is a powerful strategy to prevent them and can yield profound insights into the dynamics of each individual case examined. However, it is crucial to identify reliable sensors and installation strategies. The use of capacitive and resistive sensors is a prevalent approach; however, it is not without challenges. Drilling into the stratigraphy to place these sensors requires boreholes, which not only potentially alter the measurements but may also be impractical, both in existing buildings and new constructions. The ideal scenario is to integrate sensors during the construction or retrofitting phase to obtain reliable data but also in this case a careful planning and a correct selection of the sensors is needed. This study investigates these challenges in a controlled environment using a double climatic chamber and a real-scale timber frame façade that integrates a moisture-adaptive membrane on one side and a bituminous membrane on the other side to reproduce the stratigraphy of a flat roof. Different type of sensors as well as different installation approaches (including before and after assembly) are used and assessed. This research presents a new method for installing sensors after assembly. When applied precisely, the approach generates accurate sensor data comparable to pre-installed sensors. However, rapid changes in humidity can cause a decline in accuracy, and it’s important to restore the structure’s airtightness when mounting sensors in existing structures to ensure reliable data collection.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference May, N.: Breathability: the key to building performance (2005) May, N.: Breathability: the key to building performance (2005)
2.
go back to reference Karaglozls, A., Salonvaara, M., Kumaran, K.: The effect of waterproof coating on hygrothermal performance of a high-rise wall structure. Therm. Perform. Exterior Envelopes Build. 391–398 (1995) Karaglozls, A., Salonvaara, M., Kumaran, K.: The effect of waterproof coating on hygrothermal performance of a high-rise wall structure. Therm. Perform. Exterior Envelopes Build. 391–398 (1995)
3.
go back to reference Coelho, G., Henriques, F.: Influence of driving rain on the hygrothermal behavior of solid brick walls. J. Build. Eng. 121–132 (2016) Coelho, G., Henriques, F.: Influence of driving rain on the hygrothermal behavior of solid brick walls. J. Build. Eng. 121–132 (2016)
4.
go back to reference Lucas, F., Adelard, L., Garde, F., Boyer, H.: Study of moisture in buildings for hot humid climates. Energy Build. (2001) Lucas, F., Adelard, L., Garde, F., Boyer, H.: Study of moisture in buildings for hot humid climates. Energy Build. (2001)
5.
go back to reference Panico, S., Herrera-Avellanosa, D., Troi, A.: Monitoring rising damp in solid masonry walls: an experimental comparison of five different methods. J. Build. Eng. 75, 106999 (2023) Panico, S., Herrera-Avellanosa, D., Troi, A.: Monitoring rising damp in solid masonry walls: an experimental comparison of five different methods. J. Build. Eng. 75, 106999 (2023)
6.
go back to reference Sadłowska-Sałęga, A., Radoń, J.: Feasibility and limitation of calculative determination of hygrothermal conditions in historical buildings: case study of st. Martin church in Wiśniowa. Build. Environ. 186 (2020) Sadłowska-Sałęga, A., Radoń, J.: Feasibility and limitation of calculative determination of hygrothermal conditions in historical buildings: case study of st. Martin church in Wiśniowa. Build. Environ. 186 (2020)
7.
go back to reference Panico, S., Larcher, M., Herrera-Avellanosa, D., Cennamo, D., Troi, A.: Long-term monitoring data of hygrothermal conditions of a retrofitted historic building in Settequerce, South Tyrol (Italy). Data in Brief 53 (2024) Panico, S., Larcher, M., Herrera-Avellanosa, D., Cennamo, D., Troi, A.: Long-term monitoring data of hygrothermal conditions of a retrofitted historic building in Settequerce, South Tyrol (Italy). Data in Brief 53 (2024)
8.
go back to reference Papayianni, S.M.I.: Rendering and plasters of Ottonian monuments in Thessaloniki. In: Proceedings of the Second International Congress Study in Ancient Structures, Istanbul (2001) Papayianni, S.M.I.: Rendering and plasters of Ottonian monuments in Thessaloniki. In: Proceedings of the Second International Congress Study in Ancient Structures, Istanbul (2001)
9.
go back to reference Sandrolini, F., Franzoni, E.: An operative protocol for reliable measurements of moisture in porous materials of ancient buildings. Build. Environ. 41, 1372–1380 (2006) Sandrolini, F., Franzoni, E.: An operative protocol for reliable measurements of moisture in porous materials of ancient buildings. Build. Environ. 41, 1372–1380 (2006)
Metadata
Title
Advancements in Hygrothermal Monitoring: A Comparative Study of Sensor Reliability and Installation Strategies in Construction Elements
Authors
Simone Panico
Marco Larcher
Riccardo Pinotti
Giordano Miori
Paola Brugnara
Daniel Herrera-Avellanosa
Copyright Year
2025
DOI
https://doi.org/10.1007/978-3-031-70277-8_49