7. Advancements on Silicon Ultrasound Probes (CMUT) for Medical Imaging Applications

Authors : Giosuè Caliano, Alessandro S. Savoia

Published in: Applications in Electronics Pervading Industry, Environment and Society

Publisher: Springer International Publishing

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

Capacitive micromachined ultrasonic transducers (CMUTs) are micro-electromechanical devices (MEMS) fabricated using silicon micromachining techniques. The interest of this technology relies in its full compatibility with the microelectronic technology that makes possible to integrate on the same chip the transducer and the controlling/conditioning electronics, so as to achieve low-cost and high-performance devices. The design and fabrication of a 192-element linear array CMUT probe operating in the range 6–18 MHz is here presented. The CMUT array is micro-fabricated and packed using a novel fabrication concept specifically conceived for imaging transducer arrays. The performance optimization of the probe is performed by connecting the CMUT array with multichannel analog front-end electronic circuits housed into the probe body. Characterization and imaging results are used to assess the performance of CMUTs with respect to conventional piezoelectric transducers. This paper is a review on the activities of our group in this field.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Haller, M.I., Khuri-Yakub, B.T.: A surface micromachined electrostatic ultrasonic air transducer. Proc. IEEE Ultrason. Symp. 2, 1241–1244 (1994)CrossRef Haller, M.I., Khuri-Yakub, B.T.: A surface micromachined electrostatic ultrasonic air transducer. Proc. IEEE Ultrason. Symp. 2, 1241–1244 (1994)CrossRef
2.
go back to reference Caliano, G., Galanello, F., Caronti, A., Carotenuto, R., Pappalardo, M., Foglietti, V., Lamberti, N.: Micromachined ultrasonic transducers using silicon nitride membrane fabricated in PECVD technology. Proc. IEEE Ultrason. Symp. 1, 963–968 (2000) Caliano, G., Galanello, F., Caronti, A., Carotenuto, R., Pappalardo, M., Foglietti, V., Lamberti, N.: Micromachined ultrasonic transducers using silicon nitride membrane fabricated in PECVD technology. Proc. IEEE Ultrason. Symp. 1, 963–968 (2000)
3.
go back to reference Caliano, G., Carotenuto, R., Caronti, A., Pappalardo, M.: cMUT echographic probes: design and fabrication process. Proc. IEEE Ultrason. Symp. 2, 1067–1070 (2002) Caliano, G., Carotenuto, R., Caronti, A., Pappalardo, M.: cMUT echographic probes: design and fabrication process. Proc. IEEE Ultrason. Symp. 2, 1067–1070 (2002)
4.
go back to reference Mills, D.M., Smith, L.S.: Real-time in-vivo imaging with capacitive micromachined ultrasound transducer (cMUT) linear arrays. Proc. IEEE Ultrason. Symp. 1, 568–571 (2003) Mills, D.M., Smith, L.S.: Real-time in-vivo imaging with capacitive micromachined ultrasound transducer (cMUT) linear arrays. Proc. IEEE Ultrason. Symp. 1, 568–571 (2003)
5.
go back to reference Panda, S., Daft, C., Wagner, P., Ladabaum, I., Pellegretti, P., Bertora, F.: Microfabricated ultrasonic transducer (cMUT) probes: imaging advantages over PZT probes. In: Proceedings WFUMB (hosted by AIUM) Conference, Montreal, Canada (2003) Panda, S., Daft, C., Wagner, P., Ladabaum, I., Pellegretti, P., Bertora, F.: Microfabricated ultrasonic transducer (cMUT) probes: imaging advantages over PZT probes. In: Proceedings WFUMB (hosted by AIUM) Conference, Montreal, Canada (2003)
6.
go back to reference Caliano, G., Carotenuto, R., Cianci, E., Foglietti, V., Caronti, A., Pappalardo, M.: A cMUT linear array used as echographic probe: fabrication, characterization, and images. Proc. IEEE Ultrason. Symp. 1, 395–398 (2004) Caliano, G., Carotenuto, R., Cianci, E., Foglietti, V., Caronti, A., Pappalardo, M.: A cMUT linear array used as echographic probe: fabrication, characterization, and images. Proc. IEEE Ultrason. Symp. 1, 395–398 (2004)
7.
go back to reference Savoia, A., Caliano, G., Carotenuto, R., Longo, C., Gatta, P., Caronti, A., Cianci, E., Foglietti, V., Pappalardo, M.: Enhanced echographic images obtained improving the membrane structural layer of the cMUT probe. Proc. IEEE Ultrason. Symp. 4, 1960–1963 (2005) Savoia, A., Caliano, G., Carotenuto, R., Longo, C., Gatta, P., Caronti, A., Cianci, E., Foglietti, V., Pappalardo, M.: Enhanced echographic images obtained improving the membrane structural layer of the cMUT probe. Proc. IEEE Ultrason. Symp. 4, 1960–1963 (2005)
8.
go back to reference Caronti, A., Caliano, G., Gatta, P., Longo, C., Savoia, A., Pappalardo, M.: A finite element tool for the analysis and the design of capacitive micromachined ultrasonic transducer (cMUT) arrays for medical imaging. J. Acoust. Soc. Am. 123, 3375 (2008) Caronti, A., Caliano, G., Gatta, P., Longo, C., Savoia, A., Pappalardo, M.: A finite element tool for the analysis and the design of capacitive micromachined ultrasonic transducer (cMUT) arrays for medical imaging. J. Acoust. Soc. Am. 123, 3375 (2008)
9.
go back to reference Caliano, G., Caronti, A., Savoia, A., Longo, C., Pappalardo, M., Cianci, E., Foglietti, V.: Capacitive micromachined ultrasonic transducer (cMUT) made by a novel “Reverse Fabrication Process”. Proc. IEEE Ultrason. Symp. 1, 479–482 (2005) Caliano, G., Caronti, A., Savoia, A., Longo, C., Pappalardo, M., Cianci, E., Foglietti, V.: Capacitive micromachined ultrasonic transducer (cMUT) made by a novel “Reverse Fabrication Process”. Proc. IEEE Ultrason. Symp. 1, 479–482 (2005)
10.
go back to reference Caliano, G., et al.: Surface micromechanical process for manufacturing micromachined capacitive ultra-acoustic transducers and relevant micromachined capacitive ultra-acoustic transducer. United States Patent 7790490, 7 Sept 2010 Caliano, G., et al.: Surface micromechanical process for manufacturing micromachined capacitive ultra-acoustic transducers and relevant micromachined capacitive ultra-acoustic transducer. United States Patent 7790490, 7 Sept 2010
11.
go back to reference Savoia, A.S., Caliano, G., Pappalardo, M.: A CMUT probe for medical ultrasonography: from microfabrication to system integration. IEEE Trans. Ultrason. Ferroelectr. Freq. Control 59, 1127–1138 (2012)CrossRef Savoia, A.S., Caliano, G., Pappalardo, M.: A CMUT probe for medical ultrasonography: from microfabrication to system integration. IEEE Trans. Ultrason. Ferroelectr. Freq. Control 59, 1127–1138 (2012)CrossRef
12.
go back to reference Savoia, A., Caliano, G., Mauti, B., Pappalardo, M.: Performance optimization of a high frequency CMUT probe for medical imaging presented at the IEEE Ultrason. Symp, 2011 Savoia, A., Caliano, G., Mauti, B., Pappalardo, M.: Performance optimization of a high frequency CMUT probe for medical imaging presented at the IEEE Ultrason. Symp, 2011
13.
go back to reference Savoia, A., Caliano, G.: MEMS-based Transducers (CMUT) For medical ultrasound imaging. In: Chen, C.H. (ed.) Frontiers of Medical Imaging, pp. 445–464. World Scientific, 2014 Savoia, A., Caliano, G.: MEMS-based Transducers (CMUT) For medical ultrasound imaging. In: Chen, C.H. (ed.) Frontiers of Medical Imaging, pp. 445–464. World Scientific, 2014
Metadata
Title
Advancements on Silicon Ultrasound Probes (CMUT) for Medical Imaging Applications
Authors
Giosuè Caliano
Alessandro S. Savoia
Copyright Year
2016
DOI
https://doi.org/10.1007/978-3-319-20227-3_7