Skip to main content
Top
Published in: Cellulose 4/2021

26-01-2021 | Original Research

Aging state assessment of transformer cellulosic paper insulation using multivariate chemical indicators

Authors: Enze Zhang, Hanbo Zheng, Chuansheng Zhang, Jiaqi Wang, Kuikui Shi, Jing Guo, Harald Schwarz, Chaohai Zhang

Published in: Cellulose | Issue 4/2021

Log in

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

Compared with a single chemical indicator, the use of multivariate chemical indicators in aging status assessment of transformer cellulose paper insulation can improve the reliability of the evaluation. In this study, a non-destructive method based on multivariate chemical indicators was proposed to evaluate the remaining life of cellulosic paper insulation. The selected chemical indicators closely related to the aging of the insulating paper were analyzed. Additionally, by applying the subjective and objective weighting method, the evaluation information of each indicator was fully extracted to obtain reasonable comprehensive evaluation weights. Besides, the comprehensive evaluation index of multivariate chemical indicators was obtained by using the technique for order preference by similarity to ideal solution method, which is consistent with the deterioration law of paper insulation. Then, the correlation lifespan model between the comprehensive evaluation index of multivariate chemical indicators and the degree of polymerization of insulating paper under different aging stages was established. The effectiveness of the proposed model was verified by experiments. This promising model can increase the accuracy of the condition assessment for the transformer cellulosic paper insulation.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Literature
go back to reference Ashkezari AD, Ma H, Saha TK, Ekanayake C (2013) Application of fuzzy support vector machine for determining the health index of the insulation system of in-service power transformers. IEEE Trans Dielectr Electr Insul 20(3):965–973CrossRef Ashkezari AD, Ma H, Saha TK, Ekanayake C (2013) Application of fuzzy support vector machine for determining the health index of the insulation system of in-service power transformers. IEEE Trans Dielectr Electr Insul 20(3):965–973CrossRef
go back to reference Bustamante S, Manana M, Arroyo A et al (2019) Dissolved gas analysis equipment for online monitoring of transformer oil: a review. Sens 19(19):4057CrossRef Bustamante S, Manana M, Arroyo A et al (2019) Dissolved gas analysis equipment for online monitoring of transformer oil: a review. Sens 19(19):4057CrossRef
go back to reference Carrascal IA, Fernández-Diego C, Casado JA et al (2018) Quantification of Kraft paper ageing in mineral oil impregnated insulation systems through mechanical characterization. Cellulose 25(6):3583–3594CrossRef Carrascal IA, Fernández-Diego C, Casado JA et al (2018) Quantification of Kraft paper ageing in mineral oil impregnated insulation systems through mechanical characterization. Cellulose 25(6):3583–3594CrossRef
go back to reference Cheim L, Platts D, Prevost T, Xu S (2012) Furan analysis for liquid power transformers. IEEE Electr Insul Mag 28(2):8–21CrossRef Cheim L, Platts D, Prevost T, Xu S (2012) Furan analysis for liquid power transformers. IEEE Electr Insul Mag 28(2):8–21CrossRef
go back to reference Chen C, Li S, He T, Liu Y (2020) Concentration of 5-hydroxymethylfurfural produced by insulating paper in an oil–paper insulation system. IEEJ Trans Electr Electro Eng 15(6):828–832CrossRef Chen C, Li S, He T, Liu Y (2020) Concentration of 5-hydroxymethylfurfural produced by insulating paper in an oil–paper insulation system. IEEJ Trans Electr Electro Eng 15(6):828–832CrossRef
go back to reference CIGRE Working group (2018) Ageing of liquid impregnated cellulose for power transformers. CIGRE WG D1:53 CIGRE Working group (2018) Ageing of liquid impregnated cellulose for power transformers. CIGRE WG D1:53
go back to reference En-Wen L, Bin S (2014) Transformer health status evaluation model based on multi-feature factors. In: 2014 International Conference on Power System Technology. IEEE, pp 1417–1422 En-Wen L, Bin S (2014) Transformer health status evaluation model based on multi-feature factors. In: 2014 International Conference on Power System Technology. IEEE, pp 1417–1422
go back to reference Feng D, Yang L, Zhou L et al (2019) Effect of oil–paper–pressboard mass ratio on furfural content in transformer oil. IEEE Trans Dielectr Electr Insul 26(4):1308–1315CrossRef Feng D, Yang L, Zhou L et al (2019) Effect of oil–paper–pressboard mass ratio on furfural content in transformer oil. IEEE Trans Dielectr Electr Insul 26(4):1308–1315CrossRef
go back to reference Fernández-Diego C, Ortiz A, Carrascal IA et al (2019) Damage assessment of transformer Kraft paper insulation aged in mineral and vegetable oils. Cellulose 26(4):2653–2672CrossRef Fernández-Diego C, Ortiz A, Carrascal IA et al (2019) Damage assessment of transformer Kraft paper insulation aged in mineral and vegetable oils. Cellulose 26(4):2653–2672CrossRef
go back to reference IEEE Standard (2011) IEEE Guide for Loading Mineral-Oil-Immersed Transformers and Step-Voltage Regulators. C57.91-2011 IEEE Standard (2011) IEEE Guide for Loading Mineral-Oil-Immersed Transformers and Step-Voltage Regulators. C57.91-2011
go back to reference Jalbert J, Duchesne S, Rodriguez-Celis E et al (2012) Robust and sensitive analysis of methanol and ethanol from cellulose degradation in mineral oils. J Chromatogr A 1256:240–245CrossRef Jalbert J, Duchesne S, Rodriguez-Celis E et al (2012) Robust and sensitive analysis of methanol and ethanol from cellulose degradation in mineral oils. J Chromatogr A 1256:240–245CrossRef
go back to reference Jalbert J, Rajotte C, Lessard M-C, Rodriguez-Celis M (2018) Methanol in oil interpretation model based on transformer post-mortem paper analysis. IEEE Trans Dielectr Electr Insul 25(2):568–573CrossRef Jalbert J, Rajotte C, Lessard M-C, Rodriguez-Celis M (2018) Methanol in oil interpretation model based on transformer post-mortem paper analysis. IEEE Trans Dielectr Electr Insul 25(2):568–573CrossRef
go back to reference Jiang J, Chen R, Chen M et al (2019) Dynamic fault prediction of power transformers based on hidden Markov model of dissolved gases analysis. IEEE Trans Power Delivery 34(4):1393–1400CrossRef Jiang J, Chen R, Chen M et al (2019) Dynamic fault prediction of power transformers based on hidden Markov model of dissolved gases analysis. IEEE Trans Power Delivery 34(4):1393–1400CrossRef
go back to reference Lelekakis N, Wijaya J, Martin D, Susa D (2014) The effect of acid accumulation in power-transformer oil on the aging rate of paper insulation. IEEE Electr Insul Mag 30(3):19–26CrossRef Lelekakis N, Wijaya J, Martin D, Susa D (2014) The effect of acid accumulation in power-transformer oil on the aging rate of paper insulation. IEEE Electr Insul Mag 30(3):19–26CrossRef
go back to reference Li Y, Tang M-J, Wu F-J, et al (2013) Aging Assessment of Power Transformer Using Multi-parameters. Int J Electr Eng Inf 5(1) Li Y, Tang M-J, Wu F-J, et al (2013) Aging Assessment of Power Transformer Using Multi-parameters. Int J Electr Eng Inf 5(1)
go back to reference Li S, Yang L, Yan W, et al (2018) An effective principal component regression method for transformer life management based on indirect parameters. In: 2018 Condition monitoring and diagnosis (CMD). IEEE, pp 1–5 Li S, Yang L, Yan W, et al (2018) An effective principal component regression method for transformer life management based on indirect parameters. In: 2018 Condition monitoring and diagnosis (CMD). IEEE, pp 1–5
go back to reference Li S, Ge Z, Abu-Siada A et al (2019a) A New Technique to estimate the degree of polymerization of insulation paper using multiple aging parameters of transformer oil. IEEE Access 7:157471–157479CrossRef Li S, Ge Z, Abu-Siada A et al (2019a) A New Technique to estimate the degree of polymerization of insulation paper using multiple aging parameters of transformer oil. IEEE Access 7:157471–157479CrossRef
go back to reference Li X, Tang C, Wang J et al (2019b) Analysis and mechanism of adsorption of naphthenic mineral oil, water, formic acid, carbon dioxide, and methane on meta-aramid insulation paper. J Mater Sci 54(11):8556–8570CrossRef Li X, Tang C, Wang J et al (2019b) Analysis and mechanism of adsorption of naphthenic mineral oil, water, formic acid, carbon dioxide, and methane on meta-aramid insulation paper. J Mater Sci 54(11):8556–8570CrossRef
go back to reference Liao R, Deng X, Yang L et al (2010) Multivariate statistical analysis of thermal aging characteristic parameters of oil-paper insulation. High Volt Eng 36(11):2621–2628 Liao R, Deng X, Yang L et al (2010) Multivariate statistical analysis of thermal aging characteristic parameters of oil-paper insulation. High Volt Eng 36(11):2621–2628
go back to reference Lin LC, Sharp GP (1999) Quantitative and qualitative indices for the plant layout evaluation problem. Eur J Oper Res 116(1):100–117CrossRef Lin LC, Sharp GP (1999) Quantitative and qualitative indices for the plant layout evaluation problem. Eur J Oper Res 116(1):100–117CrossRef
go back to reference Lin M, Lin K, Lin A et al (2016) Ultra-trace analysis of furanic compounds in transformer/rectifier oils with water extraction and high-performance liquid chromatography. J Sep Sci 39(14):2777–2784CrossRef Lin M, Lin K, Lin A et al (2016) Ultra-trace analysis of furanic compounds in transformer/rectifier oils with water extraction and high-performance liquid chromatography. J Sep Sci 39(14):2777–2784CrossRef
go back to reference Liu J, Fan X, Zhang Y, Zheng H, Jiao J (2019) Temperature correction to frequency dielectric modulus and activation energy prediction of immersed cellulose insulation. IEEE Trans Dielectr Electr Insul 27(3):956–963CrossRef Liu J, Fan X, Zhang Y, Zheng H, Jiao J (2019) Temperature correction to frequency dielectric modulus and activation energy prediction of immersed cellulose insulation. IEEE Trans Dielectr Electr Insul 27(3):956–963CrossRef
go back to reference Liu J, Fan X, Zhang Y, Zheng H, Zhu M (2020b) Quantitative evaluation for moisture content of cellulose insulation material in paper/oil system based on frequency dielectric modulus technique. Cellulose 27(4):2343–2356CrossRef Liu J, Fan X, Zhang Y, Zheng H, Zhu M (2020b) Quantitative evaluation for moisture content of cellulose insulation material in paper/oil system based on frequency dielectric modulus technique. Cellulose 27(4):2343–2356CrossRef
go back to reference Ma J, Liu X (2017) Evaluation of health status of low-voltage distribution network based on order relation-entropy weight method. Power Syst Prot Control 45:87–93 Ma J, Liu X (2017) Evaluation of health status of low-voltage distribution network based on order relation-entropy weight method. Power Syst Prot Control 45:87–93
go back to reference Ma L, Chen H, Yan H et al (2018) Post evaluation of distributed energy generation combining the attribute hierarchical model and matter-element extension theory. J Cleaner Prod 184:503–510CrossRef Ma L, Chen H, Yan H et al (2018) Post evaluation of distributed energy generation combining the attribute hierarchical model and matter-element extension theory. J Cleaner Prod 184:503–510CrossRef
go back to reference Martin D, Saha T (2017) A review of the techniques used by utilities to measure the water content of transformer insulation paper. IEEE Electr Insul Mag 33(3):8–16CrossRef Martin D, Saha T (2017) A review of the techniques used by utilities to measure the water content of transformer insulation paper. IEEE Electr Insul Mag 33(3):8–16CrossRef
go back to reference Matharage SY, Liu Q, Wang ZD (2016) Aging assessment of kraft paper insulation through methanol in oil measurement. IEEE Trans Dielectr Electr Insul 23(3):1589–1596CrossRef Matharage SY, Liu Q, Wang ZD (2016) Aging assessment of kraft paper insulation through methanol in oil measurement. IEEE Trans Dielectr Electr Insul 23(3):1589–1596CrossRef
go back to reference N’cho JS, Fofana I, Hadjadj Y, Beroual A (2016) Review of physicochemical-based diagnostic techniques for assessing insulation condition in aged transformers. Energies 9(5):367CrossRef N’cho JS, Fofana I, Hadjadj Y, Beroual A (2016) Review of physicochemical-based diagnostic techniques for assessing insulation condition in aged transformers. Energies 9(5):367CrossRef
go back to reference Norazhar AB, Abu-Siada A, Islam S (2013) A review on chemical diagnosis techniques for transformer paper insulation degradation. In: 2013 Australasian Universities Power Engineering Conference (AUPEC). IEEE, pp 1–6 Norazhar AB, Abu-Siada A, Islam S (2013) A review on chemical diagnosis techniques for transformer paper insulation degradation. In: 2013 Australasian Universities Power Engineering Conference (AUPEC). IEEE, pp 1–6
go back to reference Ouyang S, Liu ZW, Li Q, Shi YL (2013) A new improved entropy method and its application in power quality evaluation. In: Advanced Materials Research. Trans Tech Publ, pp 1726–1733 Ouyang S, Liu ZW, Li Q, Shi YL (2013) A new improved entropy method and its application in power quality evaluation. In: Advanced Materials Research. Trans Tech Publ, pp 1726–1733
go back to reference Rao UM, Fofana I, Betie A et al (2019) Condition monitoring of in-service oil-filled transformers: case studies and experience. IEEE Electr Insul Mag 35(6):33–42CrossRef Rao UM, Fofana I, Betie A et al (2019) Condition monitoring of in-service oil-filled transformers: case studies and experience. IEEE Electr Insul Mag 35(6):33–42CrossRef
go back to reference Saaty TL, Vargas LG (2012) Models, methods, concepts and applications of the analytic hierarchy process. Springer, BerlinCrossRef Saaty TL, Vargas LG (2012) Models, methods, concepts and applications of the analytic hierarchy process. Springer, BerlinCrossRef
go back to reference Setnescu R, Badicu LV, Dumitran LM et al (2014) Thermal lifetime of cellulose insulation material evaluated by an activation energy based method. Cellulose 21(1):823–833CrossRef Setnescu R, Badicu LV, Dumitran LM et al (2014) Thermal lifetime of cellulose insulation material evaluated by an activation energy based method. Cellulose 21(1):823–833CrossRef
go back to reference Shroff DH, Stannett AW (1985) A review of paper aging in power transformers. IEE Proc C Gener Trans Distrib IET Digit Libr 132(6):312–319CrossRef Shroff DH, Stannett AW (1985) A review of paper aging in power transformers. IEE Proc C Gener Trans Distrib IET Digit Libr 132(6):312–319CrossRef
go back to reference Sun C, Ohodnicki PR, Stewart EM (2017) Chemical sensing strategies for real-time monitoring of transformer oil: a review. IEEE Sens J 17(18):5786–5806CrossRef Sun C, Ohodnicki PR, Stewart EM (2017) Chemical sensing strategies for real-time monitoring of transformer oil: a review. IEEE Sens J 17(18):5786–5806CrossRef
go back to reference Teymouri A, Vahidi B (2017) CO2/CO concentration ratio: a complementary method for determining the degree of polymerization of power transformer paper insulation. IEEE Electr Insul Mag 33(1):24–30CrossRef Teymouri A, Vahidi B (2017) CO2/CO concentration ratio: a complementary method for determining the degree of polymerization of power transformer paper insulation. IEEE Electr Insul Mag 33(1):24–30CrossRef
go back to reference Thakur S, Sarathi R, Gautam R, Vinu R (2017) Thermal aging of cellulosic pressboard material and its surface discharge and chemical characterization. Cellulose 24(11):5197–5210CrossRef Thakur S, Sarathi R, Gautam R, Vinu R (2017) Thermal aging of cellulosic pressboard material and its surface discharge and chemical characterization. Cellulose 24(11):5197–5210CrossRef
go back to reference Urquiza D, Garcia B, Burgos JC (2015) Statistical study on the reference values of furanic compounds in power transformers. IEEE Electr Insul Mag 4(31):15–23CrossRef Urquiza D, Garcia B, Burgos JC (2015) Statistical study on the reference values of furanic compounds in power transformers. IEEE Electr Insul Mag 4(31):15–23CrossRef
go back to reference Wang B, Xie H-L, Ren H-Y et al (2019) Application of AHP, TOPSIS, and TFNs to plant selection for phytoremediation of petroleum-contaminated soils in shale gas and oil fields. J Cleaner Prod 233:13–22CrossRef Wang B, Xie H-L, Ren H-Y et al (2019) Application of AHP, TOPSIS, and TFNs to plant selection for phytoremediation of petroleum-contaminated soils in shale gas and oil fields. J Cleaner Prod 233:13–22CrossRef
go back to reference Xi X, Wang H, Wang W, et al (2018) A quantitative characterization method of oil-paper insulation aging condition based on multi-characteristic parameters. In: 2018 12th international conference on the properties and applications of dielectric materials (ICPADM). IEEE, pp 459–462 Xi X, Wang H, Wang W, et al (2018) A quantitative characterization method of oil-paper insulation aging condition based on multi-characteristic parameters. In: 2018 12th international conference on the properties and applications of dielectric materials (ICPADM). IEEE, pp 459–462
go back to reference You P, Guo S, Zhao H, Zhao H (2017) Operation performance evaluation of power grid enterprise using a hybrid BWM-TOPSIS method. Sustainability 9(12):2329CrossRef You P, Guo S, Zhao H, Zhao H (2017) Operation performance evaluation of power grid enterprise using a hybrid BWM-TOPSIS method. Sustainability 9(12):2329CrossRef
go back to reference Zheng H, Zhang C, Zhang Y et al (2020) Optimization of ethanol detection by automatic headspace method for cellulose insulation aging of oil-immersed transformers. Polymers 12(7):1567CrossRef Zheng H, Zhang C, Zhang Y et al (2020) Optimization of ethanol detection by automatic headspace method for cellulose insulation aging of oil-immersed transformers. Polymers 12(7):1567CrossRef
Metadata
Title
Aging state assessment of transformer cellulosic paper insulation using multivariate chemical indicators
Authors
Enze Zhang
Hanbo Zheng
Chuansheng Zhang
Jiaqi Wang
Kuikui Shi
Jing Guo
Harald Schwarz
Chaohai Zhang
Publication date
26-01-2021
Publisher
Springer Netherlands
Published in
Cellulose / Issue 4/2021
Print ISSN: 0969-0239
Electronic ISSN: 1572-882X
DOI
https://doi.org/10.1007/s10570-021-03683-3

Other articles of this Issue 4/2021

Cellulose 4/2021 Go to the issue