Background

To investigate the feasibility and accuracy of a drill template based on computer-aided design (CAD) and 3D printing technology for the placement of screws in Locking Compression Pediatric Hip Plate (LCP-PHP).

Methods

LCP-PHP was used in 11 children [5 with femoral neck fracture and 6 with development dysplasia of hip (DDH)]. Using the CT data, the proximal femur model was created by a 3D printer. Fracture reduction and the placement of the screw in the femoral neck and the LCP-PHP were simulated by the computer. The navigation template was designed by the software to match the proximal femur. After the feasibility of the 3D model operation was demonstrated before the operation, the guide pins and the screws were inserted with the help of the navigate template in the operation.

Results

During surgery, the navigation template for each case was matched to the bony markers of the proximal femur. With the help of the template, in femoral neck fracture cases, three screws could be accurately inserted into the femoral neck to implant the LCP-PHP and stabilize the fracture. The template for DDH includes all operation parameters and steps for proximal femoral varus rotation and shortening osteotomy, which made the surgery much easier to perform. Radiographs taken after surgery showed that the postoperative results closely corresponded to the preoperative computer simulation. The average time taken for LCP-PHP placement was 26.5 min; radiography was used during surgery only for an average of 6.0 times. Postoperative radiographs showed good results.

Conclusion

With the use of CAD and 3D printing technology, accurate placement of individualized navigation template of LCP-PHP can be achieved. This technology can reduce intraoperative damage to the femoral neck epiphysis, decrease operation time, reduce intraoperative hemorrhage, and decrease radiation exposure to patients and personnel during the surgery.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literature
2.
go back to reference Ročák K, Poul J, Urbášek K (2013) Accuracy of proximal femur correction achieved with LCP Paediatric Hip Plates. Acta Chir Orthop Traumatol Cech 80(4):273–277PubMed Ročák K, Poul J, Urbášek K (2013) Accuracy of proximal femur correction achieved with LCP Paediatric Hip Plates. Acta Chir Orthop Traumatol Cech 80(4):273–277PubMed
6.
go back to reference Maeda S, Kita A, Fujii G, Funayama K, Yamada N, Kokubun S (2003) Avascular necrosis associated with fractures of the femoral neck in children: histological evaluation of core biopsies of the femoral head. Injury 34(4):283–286CrossRefPubMed Maeda S, Kita A, Fujii G, Funayama K, Yamada N, Kokubun S (2003) Avascular necrosis associated with fractures of the femoral neck in children: histological evaluation of core biopsies of the femoral head. Injury 34(4):283–286CrossRefPubMed
7.
go back to reference Chen H, Wang G, Li R, Sun Y, Wang F, Zhao H, Zhang P, Zhang X (2016) A novel navigation template for fixation of acetabular posterior column fractures with antegrade lag screws: design and application. Int Orthop 40(4):827–34. doi:10.1007/s00264-015-2813-8 CrossRefPubMed Chen H, Wang G, Li R, Sun Y, Wang F, Zhao H, Zhang P, Zhang X (2016) A novel navigation template for fixation of acetabular posterior column fractures with antegrade lag screws: design and application. Int Orthop 40(4):827–34. doi:10.​1007/​s00264-015-2813-8 CrossRefPubMed
8.
go back to reference Kaneyama S, Sugawara T, Sumi M (2015) Safe and accurate midcervical pedicle screw insertion procedure with the patient-specific screw guide template system. Spine (Phila Pa 1976) 40(6):341–348. doi:10.1007/s00264-015-2813-8 CrossRef Kaneyama S, Sugawara T, Sumi M (2015) Safe and accurate midcervical pedicle screw insertion procedure with the patient-specific screw guide template system. Spine (Phila Pa 1976) 40(6):341–348. doi:10.​1007/​s00264-015-2813-8 CrossRef
10.
go back to reference Huang X, Li F, Zhang F, Wang K, Wang K, Yang Q, Dang R, Su J, Shen H, Li M (2014) A cadaveric study on establishing an individualized navigation template for the placement of occipital condyle screws using a three-dimensional printing technique. Zhonghua Wai Ke Za Zhi 52(7):523–528PubMed Huang X, Li F, Zhang F, Wang K, Wang K, Yang Q, Dang R, Su J, Shen H, Li M (2014) A cadaveric study on establishing an individualized navigation template for the placement of occipital condyle screws using a three-dimensional printing technique. Zhonghua Wai Ke Za Zhi 52(7):523–528PubMed
11.
go back to reference Li L, Zhao GQ, Zhu J (2013) Treatment of trochanteric fracture in children with LCP-PHP. Chin J Pediatr Surg 34(6):474–476 Li L, Zhao GQ, Zhu J (2013) Treatment of trochanteric fracture in children with LCP-PHP. Chin J Pediatr Surg 34(6):474–476
13.
15.
go back to reference Zhang YZ, Chen B, Lu S, Yang Y, Zhao JM, Liu R, Li YB, Pei GX (2011) Preliminary application of computer-assisted patient-specific acetabular navigational template for total hip arthroplasty in adult single development dysplasia of the hip. Int J Med Robot 7(4):469–474. doi:10.1002/rcs.423 CrossRefPubMed Zhang YZ, Chen B, Lu S, Yang Y, Zhao JM, Liu R, Li YB, Pei GX (2011) Preliminary application of computer-assisted patient-specific acetabular navigational template for total hip arthroplasty in adult single development dysplasia of the hip. Int J Med Robot 7(4):469–474. doi:10.​1002/​rcs.​423 CrossRefPubMed
16.
go back to reference Audenaert E, De Smedt K, Gelaude F, Clijmans T, Pattyn C, Geebelen B (2011) A custom-made guide for femoral component positioning in hip resurfacing arthroplasty: development and validation study. Comput Aided Surg 16(6):304–309. doi:10.3109/10929088.2011.613951 CrossRefPubMed Audenaert E, De Smedt K, Gelaude F, Clijmans T, Pattyn C, Geebelen B (2011) A custom-made guide for femoral component positioning in hip resurfacing arthroplasty: development and validation study. Comput Aided Surg 16(6):304–309. doi:10.​3109/​10929088.​2011.​613951 CrossRefPubMed
Metadata
Title
Application of computer-aided design and 3D-printed navigation template in Locking Compression Pediatric Hip Plate placement for pediatric hip disease
Authors
Pengfei Zheng
Qingqiang Yao
Peng Xu
Liming Wang
Publication date
11-02-2017
Publisher
Springer International Publishing
Published in
International Journal of Computer Assisted Radiology and Surgery / Issue 5/2017
Print ISSN: 1861-6410
Electronic ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-017-1535-3

Other articles of this Issue 5/2017

International Journal of Computer Assisted Radiology and Surgery 5/2017 Go to the issue

Premium Partner