Skip to main content
Top

2019 | OriginalPaper | Chapter

12. Basics of Partial Discharge Measurement

Author : Klaus Schon

Published in: High Voltage Measurement Techniques

Publisher: Springer International Publishing

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

Partial discharge (PD) denotes a small, localized electrical discharge in the insulation between conductors, occurring when the local electric field strength exceeds a critical value. Prolonged exposure to partial discharges is known to degrade the dielectric behavior of the insulation and may even lead to complete breakdown. PD testing of high-voltage equipment and electrical apparatus is one of the most important and difficult tasks in high-voltage testing. This chapter describes the measuring instruments, the calibration methods and the test circuits for measuring the so-called apparent charge. For most apparatus, special PD measurement methods with computerized data processing have been developed, which are constantly being improved. Key words are on-site PD measurements after installation of the equipment, localization of single or multiple PD sources in spatially extended apparatus, synchronous multichannel PD measurement, VHF and UHF PD measurement techniques, permanent PD online monitoring and interference suppression methods. Partial discharges are associated with electromagnetic, acoustic, optical and chemical effects, which are also exploited for their detection and diagnosis, in particular in complex apparatus such as three-phase power transformers and gas-insulated switchgear (GIS). The PD measurement techniques at DC and impulse voltages are briefly discussed.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Temmen, K., Plath, R. (eds.): Teilentladungen in hochbeanspruchten elektrischen Isolierungen. VDE-Verlag (in preparation) Temmen, K., Plath, R. (eds.): Teilentladungen in hochbeanspruchten elektrischen Isolierungen. VDE-Verlag (in preparation)
2.
go back to reference König, D., Rao, Y.N. (eds.): Partial Discharges in Electrical Power Apparatus. VDE-Verlag GMBH, Berlin Offenbach (1993) König, D., Rao, Y.N. (eds.): Partial Discharges in Electrical Power Apparatus. VDE-Verlag GMBH, Berlin Offenbach (1993)
3.
go back to reference Kreuger, F.H.: Discharge Detection in High Voltage Equipment. Heywood, London (1964) Kreuger, F.H.: Discharge Detection in High Voltage Equipment. Heywood, London (1964)
4.
go back to reference Gemant, A., Philippoff, W.: Die Funkenstrecke mit Vorkondensator. Z. Tech. Phys. 13, 425–430 (1932) Gemant, A., Philippoff, W.: Die Funkenstrecke mit Vorkondensator. Z. Tech. Phys. 13, 425–430 (1932)
5.
go back to reference IEC 60270:2000 + AMD1:2015 CSV: High-Voltage Test Techniques—Partial Discharge Measurements (2015) [German edition: DIN EN 60270 (VDE 0434): Hochspannungs-Prüftechnik, Teilentladungsmessungen (2016)] IEC 60270:2000 + AMD1:2015 CSV: High-Voltage Test Techniques—Partial Discharge Measurements (2015) [German edition: DIN EN 60270 (VDE 0434): Hochspannungs-Prüftechnik, Teilentladungsmessungen (2016)]
6.
go back to reference IEC 60270 Amendment A1: High-Voltage Test Techniques—Partial Discharge Measurements (2015) IEC 60270 Amendment A1: High-Voltage Test Techniques—Partial Discharge Measurements (2015)
7.
go back to reference Kind, D.: Grundlagen der Messeinrichtungen für Korona-Isolationsprüfungen. ETZ-A 84, 781–787 (1963) Kind, D.: Grundlagen der Messeinrichtungen für Korona-Isolationsprüfungen. ETZ-A 84, 781–787 (1963)
8.
go back to reference Beyer, M.: Möglichkeiten und Grenzen der Teilentladungsmessungen und -ortung, Grundlagen und Messeinrichtungen. etz-a 99, 96–99, 128–131 (1978) Beyer, M.: Möglichkeiten und Grenzen der Teilentladungsmessungen und -ortung, Grundlagen und Messeinrichtungen. etz-a 99, 96–99, 128–131 (1978)
9.
go back to reference Reid, A.J., Judd, M.D.: High bandwidth measurement of partial discharge pulses in SF6. In: Proceedings of 14th ISH, Beijing, Paper G-012 (2005) Reid, A.J., Judd, M.D.: High bandwidth measurement of partial discharge pulses in SF6. In: Proceedings of 14th ISH, Beijing, Paper G-012 (2005)
10.
go back to reference Ohtsuka, S., Fukuda, K., Sogabe, A.: Measurement of PD current waveform in SF6 gas with a super high frequency wide band measurement system. In: Proceedings of 17th ISH, Hannover, Paper D-074 (2011) Ohtsuka, S., Fukuda, K., Sogabe, A.: Measurement of PD current waveform in SF6 gas with a super high frequency wide band measurement system. In: Proceedings of 17th ISH, Hannover, Paper D-074 (2011)
11.
go back to reference Schon, K.: Konzept der Impulsladungsmessung bei Teilentladungsprüfungen. etzArchiv 8, 319–324 (1986) Schon, K.: Konzept der Impulsladungsmessung bei Teilentladungsprüfungen. etzArchiv 8, 319–324 (1986)
12.
go back to reference Schwab, A., Zentner, R.: Der Übergang von der impulsförmigen in die impulslose Koronaentladung. ETZ-A 89, 402–407 (1968) Schwab, A., Zentner, R.: Der Übergang von der impulsförmigen in die impulslose Koronaentladung. ETZ-A 89, 402–407 (1968)
13.
go back to reference Küpfmüller, K.: Die Systemtheorie der elektrischen Nachrichtenübertragung. S. Hirzel Verlag, Stuttgart (1974) Küpfmüller, K.: Die Systemtheorie der elektrischen Nachrichtenübertragung. S. Hirzel Verlag, Stuttgart (1974)
14.
go back to reference König, D.: Erfassung von Teilentladungen in Hohlräumen von Epoxydharzplatten zur Beurteilung des Alterungsverhaltens bei Wechselspannung. Thesis, TU Braunschweig (1967) König, D.: Erfassung von Teilentladungen in Hohlräumen von Epoxydharzplatten zur Beurteilung des Alterungsverhaltens bei Wechselspannung. Thesis, TU Braunschweig (1967)
15.
go back to reference Szaloky, G.: Schmal- und breitbandige Teilentladungsmessungen. Bull. ASE/UCS 76, 1144–1148 (1985) Szaloky, G.: Schmal- und breitbandige Teilentladungsmessungen. Bull. ASE/UCS 76, 1144–1148 (1985)
16.
go back to reference Kachler, A.J., Nieschwietz, H.: Broad and narrow band pd measurements on power transformers. In: Proceedings of 5th ISH, Braunschweig, Paper 41.09 (1987) Kachler, A.J., Nieschwietz, H.: Broad and narrow band pd measurements on power transformers. In: Proceedings of 5th ISH, Braunschweig, Paper 41.09 (1987)
17.
go back to reference Facklam, Th, Pfeiffer, W.: Teilentladungsprüfung an Bauelementen der Niederspannungstechnik. etz 109, 440–447 (1988) Facklam, Th, Pfeiffer, W.: Teilentladungsprüfung an Bauelementen der Niederspannungstechnik. etz 109, 440–447 (1988)
18.
go back to reference Zaengl, W.S., Osvath, P., Weber, H.J.: Correlation between the bandwidth of PD detectors and its inherent integration errors. In: IEEE International Symposium on Electrical Insulation, Washington D.C. (1986) Zaengl, W.S., Osvath, P., Weber, H.J.: Correlation between the bandwidth of PD detectors and its inherent integration errors. In: IEEE International Symposium on Electrical Insulation, Washington D.C. (1986)
19.
go back to reference CISPRE 16-1: Specifications for Radio Disturbance and Immunity Measuring Apparatus and Methods—Part 1: Radio Disturbance and Immunity Measuring Apparatus (1993) CISPRE 16-1: Specifications for Radio Disturbance and Immunity Measuring Apparatus and Methods—Part 1: Radio Disturbance and Immunity Measuring Apparatus (1993)
20.
go back to reference Debinski, E.M., Douglas, J.L.: Calibration and comparison of partial-discharge and radio-interference measuring circuits. IEE Proc. 115, 1332–1340 (1968) Debinski, E.M., Douglas, J.L.: Calibration and comparison of partial-discharge and radio-interference measuring circuits. IEE Proc. 115, 1332–1340 (1968)
21.
go back to reference Harrold, R.T., Dakin, T.W.: The relationship between the picocoulomb and microvolt for corona measurements on HV transformers and other apparatus. IEEE Trans. PAS 91, 187–198 (1972) Harrold, R.T., Dakin, T.W.: The relationship between the picocoulomb and microvolt for corona measurements on HV transformers and other apparatus. IEEE Trans. PAS 91, 187–198 (1972)
22.
go back to reference Vaillancourt, G.H., Dechamplain, A., Malewski, R.A.: Simultaneous measurement of partial discharge and radio-interference voltage. IEEE Trans. IM 31, 49–52 (1982) Vaillancourt, G.H., Dechamplain, A., Malewski, R.A.: Simultaneous measurement of partial discharge and radio-interference voltage. IEEE Trans. IM 31, 49–52 (1982)
23.
go back to reference Lemke, E.: Ein neues Verfahren zur breitbandigen Messung von Teilentladungen. ELEKTRIE 23, 468–469 (1969) Lemke, E.: Ein neues Verfahren zur breitbandigen Messung von Teilentladungen. ELEKTRIE 23, 468–469 (1969)
24.
go back to reference Hartje, M.: Primary results with a partial discharge (pd) computer aided measuring system on power transformers. In: Proceedings of 5th ISH, Braunschweig, Paper 41.10 (1987) Hartje, M.: Primary results with a partial discharge (pd) computer aided measuring system on power transformers. In: Proceedings of 5th ISH, Braunschweig, Paper 41.10 (1987)
25.
go back to reference Borsi, H., Hartje, M.: A new system for computer aided automation of different commercially available partial discharge (PD) detectors. In: Proceedings of 6th ISH, New Orleans, Paper 22.18 (1989) Borsi, H., Hartje, M.: A new system for computer aided automation of different commercially available partial discharge (PD) detectors. In: Proceedings of 6th ISH, New Orleans, Paper 22.18 (1989)
26.
go back to reference Kurrat, M., Peier, D.: Wideband measurement of partial discharges for fundamental diagnostics. In: Proceedings of 7th ISH, Dresden, Paper 72.02 (1991) Kurrat, M., Peier, D.: Wideband measurement of partial discharges for fundamental diagnostics. In: Proceedings of 7th ISH, Dresden, Paper 72.02 (1991)
27.
go back to reference Buchalla, H., Koch, H., Pfeiffer, W., Stietzel, U.: A new adaptive partial discharge measuring system using digital signal processing. In: Proceedings of 8th ISH, Yokohama, Paper 62.09 (1993) Buchalla, H., Koch, H., Pfeiffer, W., Stietzel, U.: A new adaptive partial discharge measuring system using digital signal processing. In: Proceedings of 8th ISH, Yokohama, Paper 62.09 (1993)
28.
go back to reference Holle, R., Plath, R., Schon, K., Lucas, W.: Typprüfung eines digitalen TE-Messsystems nach IEC 60270. VDE-ETG-Fachveranstaltung, Kassel (2006) Holle, R., Plath, R., Schon, K., Lucas, W.: Typprüfung eines digitalen TE-Messsystems nach IEC 60270. VDE-ETG-Fachveranstaltung, Kassel (2006)
29.
go back to reference Zondervan, J.P., Gulski, E., Brooks, R.: Digital reading procedure for apparent partial discharge magnitudes. In: Proceedings of 10th ISH, Montreal, Paper 3440 (1997) Zondervan, J.P., Gulski, E., Brooks, R.: Digital reading procedure for apparent partial discharge magnitudes. In: Proceedings of 10th ISH, Montreal, Paper 3440 (1997)
30.
go back to reference CIGRE D1.33: Guide for Electrical Partial Discharge Measurements in Compliance with IEC 60270. ELECTRA Technical Brochure 366, vol. 60, p. 241 (2008) CIGRE D1.33: Guide for Electrical Partial Discharge Measurements in Compliance with IEC 60270. ELECTRA Technical Brochure 366, vol. 60, p. 241 (2008)
31.
go back to reference Werle, P., Akbari, A., Gockenbach, E., Borsi, H.: An enhanced system for partial discharge diagnostic on power transformers. In: Proceedings of 13th ISH, Delft, Paper 430 (2003) Werle, P., Akbari, A., Gockenbach, E., Borsi, H.: An enhanced system for partial discharge diagnostic on power transformers. In: Proceedings of 13th ISH, Delft, Paper 430 (2003)
32.
go back to reference Schon, K., Valentini, H.-D.: Programmable impulse charge generator for calibrating PD instruments. In: Proceedings of 10th ISH, Montreal, 33–36 (1997) Schon, K., Valentini, H.-D.: Programmable impulse charge generator for calibrating PD instruments. In: Proceedings of 10th ISH, Montreal, 33–36 (1997)
33.
go back to reference Brzostek, E., Schon, K.: Rechnergesteuerter Impulsladungsgenerator zur Kalibrierung von Teilentladungsmessgeräten. Report PTB-E-79, Wirtschaftsverlag NW, Braunschweig (2002) Brzostek, E., Schon, K.: Rechnergesteuerter Impulsladungsgenerator zur Kalibrierung von Teilentladungsmessgeräten. Report PTB-E-79, Wirtschaftsverlag NW, Braunschweig (2002)
34.
go back to reference Hu, Y., Chiampi, M., Crotti, G., Sardi, A.: Development of a set-up for the evaluation of advanced partial discharge measuring instruments. In: Proceedings of 16th ISH, Johannesburg, Paper D-13 (2009) Hu, Y., Chiampi, M., Crotti, G., Sardi, A.: Development of a set-up for the evaluation of advanced partial discharge measuring instruments. In: Proceedings of 16th ISH, Johannesburg, Paper D-13 (2009)
35.
go back to reference Seifert, S., Kessler, O., Plath, R., Emanuel, H., Boschert, V.: Influences of parasitic effects on online calibration of partial discharge measurements. In: Proceedings of 16th ISH, Johannesburg, Paper D-5 (2009) Seifert, S., Kessler, O., Plath, R., Emanuel, H., Boschert, V.: Influences of parasitic effects on online calibration of partial discharge measurements. In: Proceedings of 16th ISH, Johannesburg, Paper D-5 (2009)
36.
go back to reference Crotti, G., D’Emilio, S., Giorgi, P.A., Saracco, O.: Systems for the calibration of partial discharge calibrators. In: Proceedings of 9th ISH, Graz, 4511-1–4511-3 (1995) Crotti, G., D’Emilio, S., Giorgi, P.A., Saracco, O.: Systems for the calibration of partial discharge calibrators. In: Proceedings of 9th ISH, Graz, 4511-1–4511-3 (1995)
37.
go back to reference Lucas, W., Schon, K., Lemke, E., Elze, H.: Comparison of two techniques for calibrating PD calibrators. In: Proceedings of 10th ISH, Montreal, 67–70 (1997) Lucas, W., Schon, K., Lemke, E., Elze, H.: Comparison of two techniques for calibrating PD calibrators. In: Proceedings of 10th ISH, Montreal, 67–70 (1997)
38.
go back to reference Cherbaucich, C., Rizzi, G., Gobbo, R., Pesavento, G., Scroccaro, A.: Evaluation of the characteristics of calibrators and PD measuring systems according to IEC 60270. In: Proceedings of 12th ISH, Bangalore, Paper 6-71 (2001) Cherbaucich, C., Rizzi, G., Gobbo, R., Pesavento, G., Scroccaro, A.: Evaluation of the characteristics of calibrators and PD measuring systems according to IEC 60270. In: Proceedings of 12th ISH, Bangalore, Paper 6-71 (2001)
39.
go back to reference Schon, K., Lucas, W., et al.: Intercomparison on PD calibrators and PD instruments. In: Proceedings of 11th ISH, London, 1.5.S1–1.6.S1 (1999) Schon, K., Lucas, W., et al.: Intercomparison on PD calibrators and PD instruments. In: Proceedings of 11th ISH, London, 1.5.S1–1.6.S1 (1999)
40.
go back to reference Vaillancourt, G., Malewski, R.: Digital acquisition and processing of partial discharges during acceptance test of HV transformers. In: IEEE/PES Winter Meeting, New York, Paper 88WM 049-9 (1988) Vaillancourt, G., Malewski, R.: Digital acquisition and processing of partial discharges during acceptance test of HV transformers. In: IEEE/PES Winter Meeting, New York, Paper 88WM 049-9 (1988)
41.
go back to reference Fruth, B., Niemeyer, L., Hässig, M., Fuhr, J., Dunz, Th.: Phase resolved partial discharge measurements and computer aided partial discharge analysis performed on different high voltage apparatus. In: Proceedings of 6th ISH, New Orleans, Paper 15.03 (1989) Fruth, B., Niemeyer, L., Hässig, M., Fuhr, J., Dunz, Th.: Phase resolved partial discharge measurements and computer aided partial discharge analysis performed on different high voltage apparatus. In: Proceedings of 6th ISH, New Orleans, Paper 15.03 (1989)
42.
go back to reference Ward, B.H.: Digital Techniques for Partial Discharge Measurements. 91 SM 355-8 PWRD, with comprehensive reference list (1991) Ward, B.H.: Digital Techniques for Partial Discharge Measurements. 91 SM 355-8 PWRD, with comprehensive reference list (1991)
43.
go back to reference Gulski, E.: Digital analysis of partial discharges. IEEE Trans. DEI 2, 822–837 (1995)CrossRef Gulski, E.: Digital analysis of partial discharges. IEEE Trans. DEI 2, 822–837 (1995)CrossRef
44.
go back to reference Florkowska, B., Zydron, P.: Interpretation of partial discharge patterns for insulation diagnostic aims. In: Proceedings of 10th ISH, Montreal, Paper 3436 (1997) Florkowska, B., Zydron, P.: Interpretation of partial discharge patterns for insulation diagnostic aims. In: Proceedings of 10th ISH, Montreal, Paper 3436 (1997)
45.
go back to reference Gross, D.W., Söller, M.: Partial discharge diagnosis of large rotating machines. In: Proceedings of 14th ISH, Beijing, Paper G-044 (2005) Gross, D.W., Söller, M.: Partial discharge diagnosis of large rotating machines. In: Proceedings of 14th ISH, Beijing, Paper G-044 (2005)
46.
go back to reference Wang, Y., Li, Y.M., Qiu, Y.: Application of wavelet analysis to the detection of transformer winding deformation. In: Proceedings of 10th ISH, Montreal, Paper 3271 (1997) Wang, Y., Li, Y.M., Qiu, Y.: Application of wavelet analysis to the detection of transformer winding deformation. In: Proceedings of 10th ISH, Montreal, Paper 3271 (1997)
47.
go back to reference Zhou, C., Ma, X., Kemp, I.J.: Optimal algorithm for wavelet-based denoising in PD measurement. In: Proceedings of 13th ISH, Delft, Paper 168 (2003) Zhou, C., Ma, X., Kemp, I.J.: Optimal algorithm for wavelet-based denoising in PD measurement. In: Proceedings of 13th ISH, Delft, Paper 168 (2003)
48.
go back to reference Quak, B., Gulski, E., Smit, J.J., Seitz, P.P.: Numeric data processing to enable PD site (2005) location by time-domain reflectometry in distribution power cable system. In: Proceedings of 14th ISH, Beijing, Paper G-08 (2005) Quak, B., Gulski, E., Smit, J.J., Seitz, P.P.: Numeric data processing to enable PD site (2005) location by time-domain reflectometry in distribution power cable system. In: Proceedings of 14th ISH, Beijing, Paper G-08 (2005)
49.
go back to reference Kubota, H., Furihata, H., Inui, A., Kawaguchi, Y.: High sensitive distinction of partial discharge signal from noisy signal by wavelet transform. In: Proceedings of 14th ISH, Beijing, Paper G-097 (2005) Kubota, H., Furihata, H., Inui, A., Kawaguchi, Y.: High sensitive distinction of partial discharge signal from noisy signal by wavelet transform. In: Proceedings of 14th ISH, Beijing, Paper G-097 (2005)
50.
go back to reference Zhang, H., Blackburn, T.R., Phung, B.T., Shuying Kang, S., Naderi, M.S., Nam, H.O.: Comparison of wavelet transform de-noising methods for partial discharge detection in power cables. In: Proceedings of 14th ISH, Beijing, Paper G-103 (2005) Zhang, H., Blackburn, T.R., Phung, B.T., Shuying Kang, S., Naderi, M.S., Nam, H.O.: Comparison of wavelet transform de-noising methods for partial discharge detection in power cables. In: Proceedings of 14th ISH, Beijing, Paper G-103 (2005)
51.
go back to reference Lapp, A., Kranz, H.-G.: The influence of the quality of the reference data base on PD pattern recognition results. In: Proceedings of 10th ISH, Montreal, Paper 3065 (1997) Lapp, A., Kranz, H.-G.: The influence of the quality of the reference data base on PD pattern recognition results. In: Proceedings of 10th ISH, Montreal, Paper 3065 (1997)
52.
go back to reference Hücker, T.: UHF partial discharge expert system diagnosis. In: Proceedings of 10th ISH, Montreal, Paper 3186 (1997) Hücker, T.: UHF partial discharge expert system diagnosis. In: Proceedings of 10th ISH, Montreal, Paper 3186 (1997)
53.
go back to reference Florkowska, B., Florkowski, M., Zydron, P.: Influence of testing voltage frequency on partial discharge phase-resolved images. In: Proceedings of 13th ISH, Delft, Paper 309 (2003) Florkowska, B., Florkowski, M., Zydron, P.: Influence of testing voltage frequency on partial discharge phase-resolved images. In: Proceedings of 13th ISH, Delft, Paper 309 (2003)
54.
go back to reference Florkowski, M.: Distortion of partial discharge images caused by high voltage harmonics. In: Proceedings of 10th ISH, Montreal, Paper 3080 (1997) Florkowski, M.: Distortion of partial discharge images caused by high voltage harmonics. In: Proceedings of 10th ISH, Montreal, Paper 3080 (1997)
55.
go back to reference Nieschwitz, H., Stein, W.: Teilentladungsmessungen an Hochspannungstransformatoren als Mittel der Qualitätskontrolle. etz-a 97, 657–663 (1976) Nieschwitz, H., Stein, W.: Teilentladungsmessungen an Hochspannungstransformatoren als Mittel der Qualitätskontrolle. etz-a 97, 657–663 (1976)
56.
go back to reference Burger, H.P., Gulski, E., Smit, J.J., Brooks, R.: Digital tools for PD analysis in three-phase transformers. In: Proceedings of 10th ISH, Montreal, Paper 3510 (1997) Burger, H.P., Gulski, E., Smit, J.J., Brooks, R.: Digital tools for PD analysis in three-phase transformers. In: Proceedings of 10th ISH, Montreal, Paper 3510 (1997)
57.
go back to reference Lortie, R., Aubin, J., Vaillancourt, G.H., Su, Q.: Partial discharge detection on power transformers using a multi-terminal measurement method. In: Proceedings of 10th ISH, Montreal, Paper 3210 (1997) Lortie, R., Aubin, J., Vaillancourt, G.H., Su, Q.: Partial discharge detection on power transformers using a multi-terminal measurement method. In: Proceedings of 10th ISH, Montreal, Paper 3210 (1997)
58.
go back to reference Werle, P., Wasserberg, V., Borsi, H., Gockenbach, E.: A sensor system for partial discharge detection and localisation on dry type transformers. In: Proceedings of 12th ISH, Bangalore, Paper 6-14 (2001) Werle, P., Wasserberg, V., Borsi, H., Gockenbach, E.: A sensor system for partial discharge detection and localisation on dry type transformers. In: Proceedings of 12th ISH, Bangalore, Paper 6-14 (2001)
59.
go back to reference Plath, K.-D., Plath, R., Emanuel, H., Kalkner, W.: Synchrone dreiphasige Teilentladungsmessung an Leistungstransformatoren vor Ort und im Labor. In: ETG-Fachtagung “Diagnostik elektrischer Betriebsmittel”, Berlin, Paper O-11 (2002) Plath, K.-D., Plath, R., Emanuel, H., Kalkner, W.: Synchrone dreiphasige Teilentladungsmessung an Leistungstransformatoren vor Ort und im Labor. In: ETG-Fachtagung “Diagnostik elektrischer Betriebsmittel”, Berlin, Paper O-11 (2002)
60.
go back to reference Obralic, A., Kalkner, W., Plath, R.: Separation and individual evaluation of PD sources in stator winding of rotating machines by synchronous multi-channel measurement. In: Proceedings of 15th ISH, Ljubljana, Paper T10-512 (2007) Obralic, A., Kalkner, W., Plath, R.: Separation and individual evaluation of PD sources in stator winding of rotating machines by synchronous multi-channel measurement. In: Proceedings of 15th ISH, Ljubljana, Paper T10-512 (2007)
61.
go back to reference Johnson Hio Nam, O., Blackburn, T.R., Phung, B.T.: PD characteristics and defect patterns in three phase power cables. In: Proceedings of 16th ISH, Johannesburg, Paper D-17 (2009) Johnson Hio Nam, O., Blackburn, T.R., Phung, B.T.: PD characteristics and defect patterns in three phase power cables. In: Proceedings of 16th ISH, Johannesburg, Paper D-17 (2009)
62.
go back to reference Schaper, S., Obralic, A., Kalkner, W., Plath, R.: Synchronous multi-terminal on-site PD measurements on power transformers with an enhanced time differential evaluation method. In: Proceedings of 15th ISH, Ljubljana, Paper T7-535 (2007) Schaper, S., Obralic, A., Kalkner, W., Plath, R.: Synchronous multi-terminal on-site PD measurements on power transformers with an enhanced time differential evaluation method. In: Proceedings of 15th ISH, Ljubljana, Paper T7-535 (2007)
63.
go back to reference Balkon, C., Kalkner, W., Obralic, A., Plath, R., Rethmeier, K.: Potential of multispectral PD measurement for differentiation of interfering impulses and multiple PD sources. In: Proceedings of 16th ISH, Johannesburg, Paper D-30 (2009) Balkon, C., Kalkner, W., Obralic, A., Plath, R., Rethmeier, K.: Potential of multispectral PD measurement for differentiation of interfering impulses and multiple PD sources. In: Proceedings of 16th ISH, Johannesburg, Paper D-30 (2009)
64.
go back to reference IEC TS 62478: High Voltage Test Techniques—Measurement of Partial Discharges by Electromagnetic and Acoustic Methods (2016) IEC TS 62478: High Voltage Test Techniques—Measurement of Partial Discharges by Electromagnetic and Acoustic Methods (2016)
65.
go back to reference Wanninger, G.: Discharge currents of free mowing particles in GIS. In: Proceedings of 10th ISH, Montreal, Paper 3147 (1997) Wanninger, G.: Discharge currents of free mowing particles in GIS. In: Proceedings of 10th ISH, Montreal, Paper 3147 (1997)
66.
go back to reference Park, K., et al.: Chaotic behaviour of a free moving particle in the 362 kV gas-insulated system. In: Proceedings of 13th ISH, Delft, Paper 396 (2003) Park, K., et al.: Chaotic behaviour of a free moving particle in the 362 kV gas-insulated system. In: Proceedings of 13th ISH, Delft, Paper 396 (2003)
67.
go back to reference Judd, M.D., Farish, O.: FDTD simulation of UHF signals in GIS. In: Proceedings of 10th ISH, Montreal, Paper 3129 (1997) Judd, M.D., Farish, O.: FDTD simulation of UHF signals in GIS. In: Proceedings of 10th ISH, Montreal, Paper 3129 (1997)
68.
go back to reference Hampton, B.F., Meats, R.J.: Diagnostic measurements at UHF in gas insulated substations. IEE Proc. 135(Pt. C), 137–144 (1988)CrossRef Hampton, B.F., Meats, R.J.: Diagnostic measurements at UHF in gas insulated substations. IEE Proc. 135(Pt. C), 137–144 (1988)CrossRef
69.
go back to reference Kurrer, R., Feser, K.: The application of ultra-high frequency partial discharge measurements to gas-insulated substations. IEEE Trans. PD 13, 103–106 (1998) Kurrer, R., Feser, K.: The application of ultra-high frequency partial discharge measurements to gas-insulated substations. IEEE Trans. PD 13, 103–106 (1998)
70.
go back to reference Meijer, S., Gulski, E., Rutgers, W.R.: Evaluation of partial discharge measurements in SF6 gas insulated systems. In: Proceedings of 10th ISH, Montreal, Paper 3507 (1997) Meijer, S., Gulski, E., Rutgers, W.R.: Evaluation of partial discharge measurements in SF6 gas insulated systems. In: Proceedings of 10th ISH, Montreal, Paper 3507 (1997)
71.
go back to reference Zoetmulder, R.G.A., Meijer, S., Smit, J.J.: Condition based maintenance based on on-line partial discharge measurements of HV switchgear systems. In: Proceedings of 13th ISH, Delft, Paper 794 (2003) Zoetmulder, R.G.A., Meijer, S., Smit, J.J.: Condition based maintenance based on on-line partial discharge measurements of HV switchgear systems. In: Proceedings of 13th ISH, Delft, Paper 794 (2003)
72.
go back to reference Hoeck, S.M., Koch, M., Heindl, M.: Distribution and propagation mechanisms of PD pulses for UHF and traditional electrical measurements. In: Proceedings of 17th ISH, Hannover, Paper D-075 (2011) Hoeck, S.M., Koch, M., Heindl, M.: Distribution and propagation mechanisms of PD pulses for UHF and traditional electrical measurements. In: Proceedings of 17th ISH, Hannover, Paper D-075 (2011)
73.
go back to reference Suzuki, K., Yoshida, M., Kojima, H., Hayakawa, N., Hanai, M., Okubo, H.: Correlation between UHF electromagnetic waveforms and partial discharge current waveforms in GIS. In: Proceedings of 17th ISH, Hannover, Paper F-045 (2011) Suzuki, K., Yoshida, M., Kojima, H., Hayakawa, N., Hanai, M., Okubo, H.: Correlation between UHF electromagnetic waveforms and partial discharge current waveforms in GIS. In: Proceedings of 17th ISH, Hannover, Paper F-045 (2011)
74.
go back to reference Hoshino, T., Nojima, K., Matsumoto, S.: Investigation into frequency characteristics of UHF sensor. In: Proceedings of 12th ISH, Bangalore, Paper 7-20 (2001) Hoshino, T., Nojima, K., Matsumoto, S.: Investigation into frequency characteristics of UHF sensor. In: Proceedings of 12th ISH, Bangalore, Paper 7-20 (2001)
75.
go back to reference Neuhold, S., et al.: Experiences with UHF PD detection in GIS using external capacitive sensors on windows and disk-insulators. In: Proceedings of 15th ISH, Ljubljana, Paper T7-480 (2007) Neuhold, S., et al.: Experiences with UHF PD detection in GIS using external capacitive sensors on windows and disk-insulators. In: Proceedings of 15th ISH, Ljubljana, Paper T7-480 (2007)
76.
go back to reference Hoshino, T., et al.: Sensitivity of UHF coupler and loop electrode using UHF method and comparison for detecting a partial discharge in GIS (2). In: Proceedings of 16th ISH, Johannesburg, Paper C-37 (2009) Hoshino, T., et al.: Sensitivity of UHF coupler and loop electrode using UHF method and comparison for detecting a partial discharge in GIS (2). In: Proceedings of 16th ISH, Johannesburg, Paper C-37 (2009)
77.
go back to reference Kim, Y.-H., et al.: A study of UHF sensors embedded into GIS spacer for PD detection. In: Proceedings of 15th ISH, Ljubljana, Paper T10-630 (2007) Kim, Y.-H., et al.: A study of UHF sensors embedded into GIS spacer for PD detection. In: Proceedings of 15th ISH, Ljubljana, Paper T10-630 (2007)
78.
go back to reference Liu, W., Huang, Y., Wang, J., Qian, J.: UHF sensing and locating of partial discharges in GIS. In: Proceedings of 10th ISH, Montreal, Paper 3202 (1997) Liu, W., Huang, Y., Wang, J., Qian, J.: UHF sensing and locating of partial discharges in GIS. In: Proceedings of 10th ISH, Montreal, Paper 3202 (1997)
79.
go back to reference Miyashita, M., et al.: Novel microwave techniques for PD diagnosis in existing gas insulated equipment. In: Proceedings of 16th ISH, Johannesburg, Paper D-48 (2009) Miyashita, M., et al.: Novel microwave techniques for PD diagnosis in existing gas insulated equipment. In: Proceedings of 16th ISH, Johannesburg, Paper D-48 (2009)
80.
go back to reference Judd, M.D., Farish, O., Coventry, P.F.: UHF couplers for GIS—sensitivity and specification. In: Proceedings of 10th ISH, Montreal, Paper 3130 (1997) Judd, M.D., Farish, O., Coventry, P.F.: UHF couplers for GIS—sensitivity and specification. In: Proceedings of 10th ISH, Montreal, Paper 3130 (1997)
81.
go back to reference Fan, C.-L., Liang, W., Chung, M., Judd, M.: Comparison of UHF partial discharge sensor calibration system. In: Proceedings of 17th ISH, Hannover, Paper D-028 (2011) Fan, C.-L., Liang, W., Chung, M., Judd, M.: Comparison of UHF partial discharge sensor calibration system. In: Proceedings of 17th ISH, Hannover, Paper D-028 (2011)
82.
go back to reference Gautschi, D., Bertholet, P.: Design and testing of a novel calibration system for UHF sensors for GIS. In: Proceedings of 17th ISH, Hannover, Paper D-045 (2011) Gautschi, D., Bertholet, P.: Design and testing of a novel calibration system for UHF sensors for GIS. In: Proceedings of 17th ISH, Hannover, Paper D-045 (2011)
83.
go back to reference Hoshino, T., Koyama, H., Maruyama, S., Hanai, M.: Comparison of sensitivity between UHF method and IEC 60270 standard for on-site calibration in various GIS. In: Proceedings of 15th ISH, Ljubljana, Paper T7-264 (2007) Hoshino, T., Koyama, H., Maruyama, S., Hanai, M.: Comparison of sensitivity between UHF method and IEC 60270 standard for on-site calibration in various GIS. In: Proceedings of 15th ISH, Ljubljana, Paper T7-264 (2007)
84.
go back to reference Okabe, S., et al.: A new verification method of the UHF PD detection technique. In: Proceedings of 16th ISH, Johannesburg, Paper D-41 (2009) Okabe, S., et al.: A new verification method of the UHF PD detection technique. In: Proceedings of 16th ISH, Johannesburg, Paper D-41 (2009)
85.
go back to reference Troeger, A., Riechert, U.: Influence of different parameters on sensitivity verification for UHF PD measurement. In: Proceedings of 16th ISH, Johannesburg, Paper B-33 (2009) Troeger, A., Riechert, U.: Influence of different parameters on sensitivity verification for UHF PD measurement. In: Proceedings of 16th ISH, Johannesburg, Paper B-33 (2009)
86.
go back to reference Schichler, U., Reuter, M., Gorablenkow, J.: Partial discharge diagnostics on GIS using UHF and acoustic method. In: Proceedings of 16th ISH, Johannesburg, Paper D-9 (2009) Schichler, U., Reuter, M., Gorablenkow, J.: Partial discharge diagnostics on GIS using UHF and acoustic method. In: Proceedings of 16th ISH, Johannesburg, Paper D-9 (2009)
87.
go back to reference Twittmann, J., et al.: Measuring techniques and setup for synchronous acoustic and electric multi-site PD analysis. In: Proceedings of 16th ISH, Johannesburg, Paper D-57 (2009) Twittmann, J., et al.: Measuring techniques and setup for synchronous acoustic and electric multi-site PD analysis. In: Proceedings of 16th ISH, Johannesburg, Paper D-57 (2009)
88.
go back to reference Siegel, M., Kornhuber, S., Beltle, M., Müller, A., Tenbohlen, S.: Monitoring von Teilentladungen in Leistungstransformatoren. In: Proceedings of Hochspannungs Symposium, Stuttgart Siegel, M., Kornhuber, S., Beltle, M., Müller, A., Tenbohlen, S.: Monitoring von Teilentladungen in Leistungstransformatoren. In: Proceedings of Hochspannungs Symposium, Stuttgart
89.
go back to reference Judd, M.D., Cleary, G.P., Meijer, S.: Testing UHF partial discharge detection on a laboratory based power transformer. In: Proceedings of 13th ISH, Delft, Paper 229 (2003) Judd, M.D., Cleary, G.P., Meijer, S.: Testing UHF partial discharge detection on a laboratory based power transformer. In: Proceedings of 13th ISH, Delft, Paper 229 (2003)
90.
go back to reference Meijer, S., Agoris, P.D., Smit, J.J.: UHF PD sensitivity check on power transformers. In: Proceedings of 14th ISH, Beijing, Paper F-08 (2005) Meijer, S., Agoris, P.D., Smit, J.J.: UHF PD sensitivity check on power transformers. In: Proceedings of 14th ISH, Beijing, Paper F-08 (2005)
91.
go back to reference Rutgers, W.R., Fu, Y.H.: UHF PD detection in a power transformer. In: Proceedings of 10th ISH, Montreal, Paper 3120 (1997) Rutgers, W.R., Fu, Y.H.: UHF PD detection in a power transformer. In: Proceedings of 10th ISH, Montreal, Paper 3120 (1997)
92.
go back to reference Sinaga, H.H., Phung, B.T., Ao, A.P., Blackburn, T.R.: UHF sensors sensitivity in partial discharge sources in a transformer. In: Proceedings of 17th ISH, Hannover, Paper D-069 (2011) Sinaga, H.H., Phung, B.T., Ao, A.P., Blackburn, T.R.: UHF sensors sensitivity in partial discharge sources in a transformer. In: Proceedings of 17th ISH, Hannover, Paper D-069 (2011)
93.
go back to reference Mirzaei, H.R., et al.: New antenna design for UHF monitoring of power transformers. In: Proceedings of 18th ISH, Seoul, Paper PF-36 (2013) Mirzaei, H.R., et al.: New antenna design for UHF monitoring of power transformers. In: Proceedings of 18th ISH, Seoul, Paper PF-36 (2013)
94.
go back to reference Judd, M.D., Gray, D., Reid, A.J.: Using a step recovery diode to generate repeatable pulses for partial discharge simulation. In: Proceedings of 14th ISH, Beijing, Paper J-39 (2005) Judd, M.D., Gray, D., Reid, A.J.: Using a step recovery diode to generate repeatable pulses for partial discharge simulation. In: Proceedings of 14th ISH, Beijing, Paper J-39 (2005)
95.
go back to reference Tenbohlen, S., Siegel, M., Beltle, M., Reuter, M.: Suitability of ultra-high frequency partial discharge measurement for quality assurance and testing of power transformers. In: CIGRE SC A2&C4 Joint Colloquium, Zurich (2013) Tenbohlen, S., Siegel, M., Beltle, M., Reuter, M.: Suitability of ultra-high frequency partial discharge measurement for quality assurance and testing of power transformers. In: CIGRE SC A2&C4 Joint Colloquium, Zurich (2013)
96.
go back to reference Lemke, E., Elze, H., Weissenberg, W.: Experience in PD diagnosis tests of HV cable terminations in service using the ultra-wide band PD probing. In: Proceedings of 8th ISH, Delft, Paper 404 (2003) Lemke, E., Elze, H., Weissenberg, W.: Experience in PD diagnosis tests of HV cable terminations in service using the ultra-wide band PD probing. In: Proceedings of 8th ISH, Delft, Paper 404 (2003)
97.
go back to reference Mole, G.: Measurement of the magnitude of internal corona in cables. IEEE Trans. PAS 89, 204–212 (1970)CrossRef Mole, G.: Measurement of the magnitude of internal corona in cables. IEEE Trans. PAS 89, 204–212 (1970)CrossRef
98.
go back to reference Lukaschewitch, A., Puff, E.: Messung von Teilentladungen (TE) an langen Kabeln. Z. prakt. Energietechnik 28, 32–39 (1976) Lukaschewitch, A., Puff, E.: Messung von Teilentladungen (TE) an langen Kabeln. Z. prakt. Energietechnik 28, 32–39 (1976)
99.
go back to reference FGH: Zustandsdiagnose von Papiermasse-Kabelanlagen in Verteilungsnetzen. Technischer Bericht 300 (2006) FGH: Zustandsdiagnose von Papiermasse-Kabelanlagen in Verteilungsnetzen. Technischer Bericht 300 (2006)
100.
go back to reference Muhr, M., Sumereder, C., Woschitz, R.: The use of the 0,1 Hz cable testing method as substitution to 50 Hz measurement and the application for PD measuring and cable fault location. In: Proceedings of 12th ISH, Bangalore, Paper 6-38 (2001) Muhr, M., Sumereder, C., Woschitz, R.: The use of the 0,1 Hz cable testing method as substitution to 50 Hz measurement and the application for PD measuring and cable fault location. In: Proceedings of 12th ISH, Bangalore, Paper 6-38 (2001)
101.
go back to reference Boltze, M., Lemke, E., Strehl, T.: Comparative PD measurements under damped and continuous AC energising voltages with respect to preventive on-line PD diagnosis tests of medium voltage power cables. In: Proceedings of 13th ISH, Delft, Paper 406 (2003) Boltze, M., Lemke, E., Strehl, T.: Comparative PD measurements under damped and continuous AC energising voltages with respect to preventive on-line PD diagnosis tests of medium voltage power cables. In: Proceedings of 13th ISH, Delft, Paper 406 (2003)
102.
go back to reference Kumm, T., Rethmeier, K., Kalkner, W., Zinburg, E.: A new approach of synchronous PD measurement at both ends of a H.V. gas pressure cable system. In: Proceedings of 14th ISH, Beijing, Paper F-11 (2005) Kumm, T., Rethmeier, K., Kalkner, W., Zinburg, E.: A new approach of synchronous PD measurement at both ends of a H.V. gas pressure cable system. In: Proceedings of 14th ISH, Beijing, Paper F-11 (2005)
103.
go back to reference Pommerenke, D., Strehl, T., Kalkner, W.: Directional coupler sensor for partial discharge recognition on high voltage cable systems. In: Proceedings of 10. ISH, Montreal (1997), Paper 3447 Pommerenke, D., Strehl, T., Kalkner, W.: Directional coupler sensor for partial discharge recognition on high voltage cable systems. In: Proceedings of 10. ISH, Montreal (1997), Paper 3447
104.
go back to reference Heinrich, R., Kalkner, W., Plath, R., Obst, D.: On-site application of directional coupler sensors for sensitive PD measurement and location on a 380 kV cable line. In: Proceedings of 12th ISH, Bangalore, Paper 6-34 (2001) Heinrich, R., Kalkner, W., Plath, R., Obst, D.: On-site application of directional coupler sensors for sensitive PD measurement and location on a 380 kV cable line. In: Proceedings of 12th ISH, Bangalore, Paper 6-34 (2001)
105.
go back to reference Gulski, E., van Vliet, M.G.A., Smit, J.J., de Vries, F.: Practical experiences on on-line PD detection on distribution power cables. In: Proceedings of 14th ISH, Beijing, Paper F-24 (2005) Gulski, E., van Vliet, M.G.A., Smit, J.J., de Vries, F.: Practical experiences on on-line PD detection on distribution power cables. In: Proceedings of 14th ISH, Beijing, Paper F-24 (2005)
106.
go back to reference Plath, R., Vaterrodt, K., Habel, M.: Symmetric 3-channel inductive PD detection with optimized SNR for extruded power cables. In: Proceedings of 17th ISH, Hannover, Paper D-016 (2011) Plath, R., Vaterrodt, K., Habel, M.: Symmetric 3-channel inductive PD detection with optimized SNR for extruded power cables. In: Proceedings of 17th ISH, Hannover, Paper D-016 (2011)
107.
go back to reference Ghani, A.B.A., Chacrabarty, C.K.: Investigation of the transient magnetic field components propagation characteristics due to partial discharge in XLPE cable. In: Proceedings of 16th ISH, Johannesburg, Paper B-18 (2009) Ghani, A.B.A., Chacrabarty, C.K.: Investigation of the transient magnetic field components propagation characteristics due to partial discharge in XLPE cable. In: Proceedings of 16th ISH, Johannesburg, Paper B-18 (2009)
108.
go back to reference Denissov, D., Köhler, W., Tenbohlen, S., Grund, R., Klein, T.: Optimization of UHF sensor geometry for on-line partial discharge detection in cable terminations. In: Proceedings of 16th ISH, Johannesburg, Paper D-24 (2009) Denissov, D., Köhler, W., Tenbohlen, S., Grund, R., Klein, T.: Optimization of UHF sensor geometry for on-line partial discharge detection in cable terminations. In: Proceedings of 16th ISH, Johannesburg, Paper D-24 (2009)
109.
go back to reference Howells, E., Norton, E.: Detection of partial discharges in transformers using acoustic emission techniques. IEEE Trans. PAS 97, 1538–1549 (1978)CrossRef Howells, E., Norton, E.: Detection of partial discharges in transformers using acoustic emission techniques. IEEE Trans. PAS 97, 1538–1549 (1978)CrossRef
110.
go back to reference Bengtsson, T., Kols, H., Jönsson, B.: Transformer PD diagnosis using acoustic emission techniques. In: Proceedings of 10th ISH, Montreal, Paper 3057 (1997) Bengtsson, T., Kols, H., Jönsson, B.: Transformer PD diagnosis using acoustic emission techniques. In: Proceedings of 10th ISH, Montreal, Paper 3057 (1997)
111.
go back to reference Phung, B.T., Liu, Z., Blackburn, T.R., James, R.E.: Signal characteristics of partial discharge acoustic emissions. In: Proceedings of 12th ISH, Bangalore, Paper 6-59 (2001) Phung, B.T., Liu, Z., Blackburn, T.R., James, R.E.: Signal characteristics of partial discharge acoustic emissions. In: Proceedings of 12th ISH, Bangalore, Paper 6-59 (2001)
112.
go back to reference Markalous, S.M., Grossmann, E., Feser, K.: Online acoustic PD-measurements of oil/paper-insulated transformers—methods and results. In: Proceedings of 13th ISH, Delft, Paper 164 (2003) Markalous, S.M., Grossmann, E., Feser, K.: Online acoustic PD-measurements of oil/paper-insulated transformers—methods and results. In: Proceedings of 13th ISH, Delft, Paper 164 (2003)
113.
go back to reference Markalous, S.M., Tenbohlen, S., Feser, K.: Improvement of acoustic detection and localization accuracy by sensitive electromagnetic PD measurements under oil in the UHF range. In: Proceedings of 14th ISH, Beijing, Paper G-039 (2005) Markalous, S.M., Tenbohlen, S., Feser, K.: Improvement of acoustic detection and localization accuracy by sensitive electromagnetic PD measurements under oil in the UHF range. In: Proceedings of 14th ISH, Beijing, Paper G-039 (2005)
114.
go back to reference Siegel, M., Tenbohlen, S., Kornhuber, S.: Neue Methoden zur Ortung mehrerer TE-Quellen mittels akustischem Sensorarray. VDE ETG Fachtagung, Fulda (2012) Siegel, M., Tenbohlen, S., Kornhuber, S.: Neue Methoden zur Ortung mehrerer TE-Quellen mittels akustischem Sensorarray. VDE ETG Fachtagung, Fulda (2012)
115.
go back to reference Beltle, M., Siegel, M., Tenbohlen, S.: Investigations of in-oil methods for PD detection and vibration measurement. In: Proceedings of 18th ISH, Seoul, Paper OD5-04 (2013) Beltle, M., Siegel, M., Tenbohlen, S.: Investigations of in-oil methods for PD detection and vibration measurement. In: Proceedings of 18th ISH, Seoul, Paper OD5-04 (2013)
116.
go back to reference Broniecki, U., et al.: Localization of partial discharges in power transformers by combined acoustic and electric measurements. In: Proceedings of 17th ISH, Hannover, Paper D-059 (2011) Broniecki, U., et al.: Localization of partial discharges in power transformers by combined acoustic and electric measurements. In: Proceedings of 17th ISH, Hannover, Paper D-059 (2011)
117.
go back to reference Grossmann, E., Feser, K.: New calibrators for acoustic PD-measurements. In: Proceedings of 12th ISH, Bangalore, Paper 6-61 (2001) Grossmann, E., Feser, K.: New calibrators for acoustic PD-measurements. In: Proceedings of 12th ISH, Bangalore, Paper 6-61 (2001)
118.
go back to reference Beyer, M., Borsi, H., Cachay, O.: Some aspects about basic investigations of acoustic partial discharge (PD) detection and location in cast epoxy resin coils. In: Proceedings of 6th ISH, New Orleans, Paper 22.20 (1989) Beyer, M., Borsi, H., Cachay, O.: Some aspects about basic investigations of acoustic partial discharge (PD) detection and location in cast epoxy resin coils. In: Proceedings of 6th ISH, New Orleans, Paper 22.20 (1989)
119.
go back to reference Hartje, M., Krump, R., Lange, H., Schulenberg, J.: Acoustic emission qualities of partial discharges (PD) in bushing materials. In: Proceedings of 15th ISH, Ljubljana, Paper TC-638 (2007) Hartje, M., Krump, R., Lange, H., Schulenberg, J.: Acoustic emission qualities of partial discharges (PD) in bushing materials. In: Proceedings of 15th ISH, Ljubljana, Paper TC-638 (2007)
120.
go back to reference Zargari, A., Blackburn, T.R.: Partial discharge detection in SF6 GIS using optical fibre techniques. In: Proceedings of 10th ISH, Montreal, Paper 3518 (1997) Zargari, A., Blackburn, T.R.: Partial discharge detection in SF6 GIS using optical fibre techniques. In: Proceedings of 10th ISH, Montreal, Paper 3518 (1997)
121.
go back to reference Rohwetter, P., Habel, W.R., Heidmann, G., Pepper, D.: Fibre-optic acoustic detection of damage processes in elastomeric insulation under AC and DC stress. In: Proceedings of 18th ISH, Seoul, Paper OD1-03 (2013) Rohwetter, P., Habel, W.R., Heidmann, G., Pepper, D.: Fibre-optic acoustic detection of damage processes in elastomeric insulation under AC and DC stress. In: Proceedings of 18th ISH, Seoul, Paper OD1-03 (2013)
122.
go back to reference Borneburg, D.: Über den praktischen Einsatz einer UV-Kamera zur Detektion, Lokalisierung und Echtzeitdarstellung von Korona-Entladungen an elektrischen Betriebsmitteln. In: ETG Fachbericht Nr. 104, Diagnostik elektrischer Betriebsmittel, Köln, 45–50 (2006) Borneburg, D.: Über den praktischen Einsatz einer UV-Kamera zur Detektion, Lokalisierung und Echtzeitdarstellung von Korona-Entladungen an elektrischen Betriebsmitteln. In: ETG Fachbericht Nr. 104, Diagnostik elektrischer Betriebsmittel, Köln, 45–50 (2006)
123.
go back to reference Cardoso, J.A.A., Oliveira Filho, O., de Mello, D.R.: Use of UV cameras for corona tests in high voltage. In: Proceedings of 16th ISH, Johannesburg, Paper A-17 (2009) Cardoso, J.A.A., Oliveira Filho, O., de Mello, D.R.: Use of UV cameras for corona tests in high voltage. In: Proceedings of 16th ISH, Johannesburg, Paper A-17 (2009)
124.
go back to reference Schwarz, R., Muhr, M., Pack, S.: Partial discharge detection and localisation for application in transformers. In: Proceedings of 13th ISH, Rotterdam, Paper 183 (2003) Schwarz, R., Muhr, M., Pack, S.: Partial discharge detection and localisation for application in transformers. In: Proceedings of 13th ISH, Rotterdam, Paper 183 (2003)
125.
go back to reference Muhr, M., Schwarz, R.: Partial discharge behaviour of oil board arrangements by the installation of fibre-optic technology for monitoring. In: Proceedings of 15th ISH, Ljubljana, Paper T10-325 (2007) Muhr, M., Schwarz, R.: Partial discharge behaviour of oil board arrangements by the installation of fibre-optic technology for monitoring. In: Proceedings of 15th ISH, Ljubljana, Paper T10-325 (2007)
126.
go back to reference Behrend, S., Kalkner, W., Heidmann, G., Emanuel, H., Plath, R.: Synchronous optical and electrical PD measurements. In: Proceedings of 17th ISH, Hannover, Paper D-048 (2011) Behrend, S., Kalkner, W., Heidmann, G., Emanuel, H., Plath, R.: Synchronous optical and electrical PD measurements. In: Proceedings of 17th ISH, Hannover, Paper D-048 (2011)
127.
go back to reference Pepper, D., et al.: Sensitive optical detection of partial discharges with fluorescent fibers. In: Proceedings of 19th ISH, Pilsen, Paper 598 (2015) Pepper, D., et al.: Sensitive optical detection of partial discharges with fluorescent fibers. In: Proceedings of 19th ISH, Pilsen, Paper 598 (2015)
128.
go back to reference IEC 60599: Mineral Oil-Impregnated Electrical Equipment in Service—Guide to the Interpretation of Dissolved and Free Gases Analysis (1999 + 2007) [German edition: DIN EN 60599, VDE 0370 Teil 7: Im Betrieb befindliche, mit Mineralöl imprägnierte elektrische Geräte – Leitfaden zur Interpretation der Analyse gelöster und freier Gase (2008)] IEC 60599: Mineral Oil-Impregnated Electrical Equipment in Service—Guide to the Interpretation of Dissolved and Free Gases Analysis (1999 + 2007) [German edition: DIN EN 60599, VDE 0370 Teil 7: Im Betrieb befindliche, mit Mineralöl imprägnierte elektrische Geräte – Leitfaden zur Interpretation der Analyse gelöster und freier Gase (2008)]
129.
go back to reference Werle, P., et. al.: Comparison of different DGA (Dissolved Gas Analysis) methods for the conditioning assessment of power transformers. In: Proceedings of 12th ISH, Bangalore, Paper F-58 (2001) Werle, P., et. al.: Comparison of different DGA (Dissolved Gas Analysis) methods for the conditioning assessment of power transformers. In: Proceedings of 12th ISH, Bangalore, Paper F-58 (2001)
130.
go back to reference Tenbohlen, S., et al.: Investigation on sampling, measurement and interpretation of gas-in-oil analysis for power transformers. In: CIGRE Colloquium, Paris, Paper D1-204 (2008) Tenbohlen, S., et al.: Investigation on sampling, measurement and interpretation of gas-in-oil analysis for power transformers. In: CIGRE Colloquium, Paris, Paper D1-204 (2008)
131.
go back to reference Müller, A., Beltle, M., Coenen, S., Tenbohlen, S.: Correlation of DGA, UHF PD measurement and vibration data for power transformer monitoring. In: Proceedings of 17th ISH, Hannover, Paper F-071 (2011) Müller, A., Beltle, M., Coenen, S., Tenbohlen, S.: Correlation of DGA, UHF PD measurement and vibration data for power transformer monitoring. In: Proceedings of 17th ISH, Hannover, Paper F-071 (2011)
132.
go back to reference Chang, Y., et al.: Partial discharge detection of GIS using SWNT-UHF fusion sensor. In: Proceedings of 16th ISH, Johannesburg, Paper C-25 (2009) Chang, Y., et al.: Partial discharge detection of GIS using SWNT-UHF fusion sensor. In: Proceedings of 16th ISH, Johannesburg, Paper C-25 (2009)
133.
go back to reference Fromm, U.: Interpretation of partial discharges at dc voltages. IEEE Trans. Dielectr. Electr. Insul. 2 (1995)CrossRef Fromm, U.: Interpretation of partial discharges at dc voltages. IEEE Trans. Dielectr. Electr. Insul. 2 (1995)CrossRef
134.
go back to reference Morshuis, P.H.M., Smit, J.J.: Partial discharges at dc voltage: their mechanism, detection and analysis. IEEE Trans. Dielectr. Electr. Insul. 12, 328–340 (2005)CrossRef Morshuis, P.H.M., Smit, J.J.: Partial discharges at dc voltage: their mechanism, detection and analysis. IEEE Trans. Dielectr. Electr. Insul. 12, 328–340 (2005)CrossRef
135.
go back to reference Schichler, U., Kuschel, M., Gorablenkow, J.: Partial discharge measurement on gas-insulated HVDC equipment. In: Proceedings of 18th ISH, Seoul, Paper OH1-01 (2013) Schichler, U., Kuschel, M., Gorablenkow, J.: Partial discharge measurement on gas-insulated HVDC equipment. In: Proceedings of 18th ISH, Seoul, Paper OH1-01 (2013)
136.
go back to reference Rethmeier, K., Küchler, A., Liebschner, M., Krause, Ch., Kraetge, A., Krüger, M.: Enhanced partial discharge evaluation methods for DC PD measurements using fully digital PD analysing systems. In: Proceedings of 16th ISH, Cape Town, Paper A-13 (2009) Rethmeier, K., Küchler, A., Liebschner, M., Krause, Ch., Kraetge, A., Krüger, M.: Enhanced partial discharge evaluation methods for DC PD measurements using fully digital PD analysing systems. In: Proceedings of 16th ISH, Cape Town, Paper A-13 (2009)
137.
go back to reference Kästner, B., Hoek, S.M., Plath, R., Rethmeier, K.: A modern approach to differential partial discharge diagnosis. In: Proceedings of 19th ISH, Pilsen, Paper 573 (2015) Kästner, B., Hoek, S.M., Plath, R., Rethmeier, K.: A modern approach to differential partial discharge diagnosis. In: Proceedings of 19th ISH, Pilsen, Paper 573 (2015)
138.
go back to reference IEC TS 61934: Electrical Insulation Materials and Systems—Electrical Measurement of Partial Discharges (PD) Under Short Rise Time and Repetitive Voltage Impulses (2011) IEC TS 61934: Electrical Insulation Materials and Systems—Electrical Measurement of Partial Discharges (PD) Under Short Rise Time and Repetitive Voltage Impulses (2011)
139.
go back to reference Umemoto, T., Kainaga, S., Ishikura, T., Yoshimura, M., Tsurimoto, T.: Partial discharge detection under impulse voltage application by acoustic emission sensors in oil/pressboard composite insulation system. In: Proceedings of 19th ISH, Pilsen, Paper 206 (2015) Umemoto, T., Kainaga, S., Ishikura, T., Yoshimura, M., Tsurimoto, T.: Partial discharge detection under impulse voltage application by acoustic emission sensors in oil/pressboard composite insulation system. In: Proceedings of 19th ISH, Pilsen, Paper 206 (2015)
Metadata
Title
Basics of Partial Discharge Measurement
Author
Klaus Schon
Copyright Year
2019
DOI
https://doi.org/10.1007/978-3-030-21770-9_12