Abstract

The electrocardiogram signals of humans heart are usually estimated using wet silver/silver chloride (Ag/AgCl) electrodes. These wet electrodes cannot be reused and require extra skin preparation (application of conductive gel) which may cause skin aggravation in long run, and also during measurement of the electrocardiogram signals, it enhances a common-mode noise due to loose contact with skin. Therefore, this paper proposes the design, fabrication and testing of dry electrodes for recording the ECG signals which overcomes the problems associated with wet Ag/AgCl electrodes. These electrodes are adaptable, biocompatible, reusable and conduction gel-free. Carbon paste was coated on a flexible circular polymer substrate of different diameters (E1-20 mm, E2-16 mm, E3-1 mm) to prepare dry Electrocardiogram electrodes. The conducting performance of E1, E2, E3 and Ag/AgCl electrodes was analysed by measuring the skin–electrode impedance and observed that the skin impedance is inversely proportion to the electrodes area. The skin–electrode impedance results concluded that the electrodes with the largest diameter exhibited better performance in terms of the conductivity for acquisition of quality electrocardiogram signals. The skin impedance of dry electrodes (E1, E2, E3) and Ag/AgCl electrodes was measured and compared at a common frequency of 10 Hz. The raw electrocardiogram signal detected should be pre-processed through various signal processing units to overcome the high level noise. The aim of this work is to design dry electrodes and also pre-process the signals recorded by the dry electrocardiogram electrodes which can be further used for portable applications. Also, this paper presents the working of dry electrodes and its comparison with wet Ag/AgCl electrodes for medical and research purposes.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference S. Balambigai, P. Jeevitha, A survey on investigation of vital human parameters from photoplethsmography signal to predict the risk of cardiovascular diseases, in 2017 International Conference on Advanced Computing and Communication Systems (ICACCS), Coimbatore, (2017), pp. 1–4. https://doi.org/10.1109/ICACCS.2017.8014561 S. Balambigai, P. Jeevitha, A survey on investigation of vital human parameters from photoplethsmography signal to predict the risk of cardiovascular diseases, in 2017 International Conference on Advanced Computing and Communication Systems (ICACCS), Coimbatore, (2017), pp. 1–4. https://​doi.​org/​10.​1109/​ICACCS.​2017.​8014561
2.
go back to reference S. Mejhoudi, R. Latif, A. Toumanari, W. Jenkal, A. Elouardi, Implementation and evaluation of ECG signal processing algorithms on embedded architectures, in 2017 International Conference on Electrical and Information Technologies (ICEIT), Rabat, (2017), pp.1–6. https://doi.org/10.1109/EITech.2017.8255287 S. Mejhoudi, R. Latif, A. Toumanari, W. Jenkal, A. Elouardi, Implementation and evaluation of ECG signal processing algorithms on embedded architectures, in 2017 International Conference on Electrical and Information Technologies (ICEIT), Rabat, (2017), pp.1–6. https://​doi.​org/​10.​1109/​EITech.​2017.​8255287
3.
go back to reference M.H. Chowdhury, Q.D. Hossain, P. Saha, M.M. Rahaman, Design, fabrication and performance evaluation of a three electrode ECG recorder, in 2016 International Conference on Innovations in Science, Engineering and Technology (ICISET), Dhaka, (2016), pp. 1–4. https://doi.org/10.1109/ICISET.2016.7856500 M.H. Chowdhury, Q.D. Hossain, P. Saha, M.M. Rahaman, Design, fabrication and performance evaluation of a three electrode ECG recorder, in 2016 International Conference on Innovations in Science, Engineering and Technology (ICISET), Dhaka, (2016), pp. 1–4. https://​doi.​org/​10.​1109/​ICISET.​2016.​7856500
4.
go back to reference B.B. Winter, J.G. Webster, Driven-right-leg circuit design. IEEE Trans. Biomed. Eng. BME-30(1), 62–66 (1983) B.B. Winter, J.G. Webster, Driven-right-leg circuit design. IEEE Trans. Biomed. Eng. BME-30(1), 62–66 (1983)
5.
go back to reference E.M. Spinelli, N.H. Martinez, M.A. Mayosky, A transconductance driven-right-leg circuit. IEEE Trans. Biomed. Eng. 46(12), 1466–1469 (1999) E.M. Spinelli, N.H. Martinez, M.A. Mayosky, A transconductance driven-right-leg circuit. IEEE Trans. Biomed. Eng. 46(12), 1466–1469 (1999)
6.
go back to reference H. Kim, Y. Kim, Y. Kim, Miniature electrocardiography sensor using a flexible printed circuit and MEMS technology, in 2008 IEEE International Conference on Multisensor Fusion and Integration for Intelligent Systems, Seoul, (2008), pp. 545–550. https://doi.org/10.1109/MFI.2008.4648052. H. Kim, Y. Kim, Y. Kim, Miniature electrocardiography sensor using a flexible printed circuit and MEMS technology, in 2008 IEEE International Conference on Multisensor Fusion and Integration for Intelligent Systems, Seoul, (2008), pp. 545–550. https://​doi.​org/​10.​1109/​MFI.​2008.​4648052.
7.
go back to reference A. Searle, L. Kirkup, A direct comparison of wet, dry and insulating bioelectric recording electrodes. Physiol. Meas. 21(2), 271 (2000) A. Searle, L. Kirkup, A direct comparison of wet, dry and insulating bioelectric recording electrodes. Physiol. Meas. 21(2), 271 (2000)
8.
go back to reference A. Gruetzmann, S. Hansen, J. Müller, Novel dry electrodes for ECG monitoring. Physiol. Meas. 28(11), 1375 (2007) A. Gruetzmann, S. Hansen, J. Müller, Novel dry electrodes for ECG monitoring. Physiol. Meas. 28(11), 1375 (2007)
9.
go back to reference Y. Zhou, X. Ding, J. Zhang, Y. Duan, J. Hu, X. Yang, Fabrication of conductive fabric as textile electrode for ECG monitoring. Fiber Polym. 15(11), 260–2264 (2014) Y. Zhou, X. Ding, J. Zhang, Y. Duan, J. Hu, X. Yang, Fabrication of conductive fabric as textile electrode for ECG monitoring. Fiber Polym. 15(11), 260–2264 (2014)
10.
go back to reference H. Jung, J. Moon, D. Baek, J. Lee, Y. Choi, J. Hong, S. Lee, CNT/PDMS composite flexible dry electrodes for long-term ECG monitoring. IEEE Trans. Biomed. Eng. 59(5), 1472–1479 (2012)CrossRef H. Jung, J. Moon, D. Baek, J. Lee, Y. Choi, J. Hong, S. Lee, CNT/PDMS composite flexible dry electrodes for long-term ECG monitoring. IEEE Trans. Biomed. Eng. 59(5), 1472–1479 (2012)CrossRef
11.
go back to reference A. Karilainen, J. Hansen, S. Muller, Dry and capacitive electrodes for long-term ECG-monitoring, in Proceedings of the 8th Annual Workshop on Semiconductor Advances for Future Electronics, Veldhoven, (2005), pp. 155–161 A. Karilainen, J. Hansen, S. Muller, Dry and capacitive electrodes for long-term ECG-monitoring, in Proceedings of the 8th Annual Workshop on Semiconductor Advances for Future Electronics, Veldhoven, (2005), pp. 155–161
12.
go back to reference P. Griss, H.K. Tolvanen-Laasko, P. Meriläinen, G. Stemme, Characterization of micromachined spiked biopotential electrodes. IEEE Trans. Biomed. Eng. 49(6), 597–604 (2002)CrossRef P. Griss, H.K. Tolvanen-Laasko, P. Meriläinen, G. Stemme, Characterization of micromachined spiked biopotential electrodes. IEEE Trans. Biomed. Eng. 49(6), 597–604 (2002)CrossRef
13.
go back to reference K.P. Hoffmann, R. Ruff, Flexible dry surface-electrodes for ECG long-term monitoring, in Engineering in Medicine and Biology Society, Proceedings of the 29th Annual International Conference of the IEEE, EMBS, Lyon, (2007), pp. 5739–5742 K.P. Hoffmann, R. Ruff, Flexible dry surface-electrodes for ECG long-term monitoring, in Engineering in Medicine and Biology Society, Proceedings of the 29th Annual International Conference of the IEEE, EMBS, Lyon, (2007), pp. 5739–5742
14.
go back to reference C. Fonseca, J.P. Silva Cunha, R.E. Martins, V.M. Ferreira, J.P. Marques de Sá, M.A. Barbosa, A. Martins da Silva, A novel dry active electrode for EEG recording. IEEE Trans. Biomed. Eng. 54(1), 162–165 (2007) C. Fonseca, J.P. Silva Cunha, R.E. Martins, V.M. Ferreira, J.P. Marques de Sá, M.A. Barbosa, A. Martins da Silva, A novel dry active electrode for EEG recording. IEEE Trans. Biomed. Eng. 54(1), 162–165 (2007)
15.
go back to reference J.Y. Baek, J.H. An, J.M. Chio, K.S. Park, S.H. Lee, Flexible polymeric dry electrodes for the long-term monitoring of ECG. Sens. Actuators A 143, 423–429 (2008)CrossRef J.Y. Baek, J.H. An, J.M. Chio, K.S. Park, S.H. Lee, Flexible polymeric dry electrodes for the long-term monitoring of ECG. Sens. Actuators A 143, 423–429 (2008)CrossRef
16.
go back to reference W.C. Ng, H.L. Seet, K.S. Lee, N. Ning, W.X. Tai, M. Sutedja, J.Y.H. Fuh, X.P. Li, Microspike EEG electrode and the vacuum-casting technology for mass production. J. Mater. Process. Technol. 209, 4434–4438 (2009) W.C. Ng, H.L. Seet, K.S. Lee, N. Ning, W.X. Tai, M. Sutedja, J.Y.H. Fuh, X.P. Li, Microspike EEG electrode and the vacuum-casting technology for mass production. J. Mater. Process. Technol. 209, 4434–4438 (2009)
18.
go back to reference K. Yang et al., Comparison between KAPTON polyimide insulation layers and nylon plates in superconducting tapes winding, in 2015 IEEE International Conference on Applied Super conductivity and Electromagnetic DevicesASEMD), Shanghai, (2015), pp. 294–295. https://doi.org/10.1109/ASEMD.2015.7453580 K. Yang et al., Comparison between KAPTON polyimide insulation layers and nylon plates in superconducting tapes winding, in 2015 IEEE International Conference on Applied Super conductivity and Electromagnetic DevicesASEMD), Shanghai, (2015), pp. 294–295. https://​doi.​org/​10.​1109/​ASEMD.​2015.​7453580
20.
go back to reference J. Yoo, H.J. Yoo, Fabric circuit board-based dry electrode and its characteristics for long-term physiological signal recording. Ann. Int. Conf. Eng. Med. Bio. Soc. 2497–2500 (2011) J. Yoo, H.J. Yoo, Fabric circuit board-based dry electrode and its characteristics for long-term physiological signal recording. Ann. Int. Conf. Eng. Med. Bio. Soc. 2497–2500 (2011)
21.
go back to reference V. Perumal, Mask design and simulation: computer aided design for lab-on-chip application. Adv. Mater. Res. 832, 84 (2013). https://doi.org/10.4028/www.scientific.net/AMR.832.84 V. Perumal, Mask design and simulation: computer aided design for lab-on-chip application. Adv. Mater. Res. 832, 84 (2013). https://​doi.​org/​10.​4028/​www.​scientific.​net/​AMR.​832.​84
22.
go back to reference M.T. Shahid, M. Ammar Khan, M.Z. Khan, Design and development of a computer numeric controlled 3D Printer, laser cutter and 2D plotter all in one machine, in 2019 16th International Bhurban Conference on Applied Sciences and Technology (IBCAST), Islamabad, Pakistan, (2019), pp. 569575. https://doi.org/10.1109/IBCAST.2018667138 M.T. Shahid, M. Ammar Khan, M.Z. Khan, Design and development of a computer numeric controlled 3D Printer, laser cutter and 2D plotter all in one machine, in 2019 16th International Bhurban Conference on Applied Sciences and Technology (IBCAST), Islamabad, Pakistan, (2019), pp. 569575. https://​doi.​org/​10.​1109/​IBCAST.​2018667138
23.
go back to reference M. Abu-Saude, B.I. Morshed, Polypyrrole (PPy) conductive polymer coating of dry patterned vertical CNT (pvCNT) electrode to improve mechanical stability, in 2016 IEEE Topical Conference on Biomedical Wireless Technologies, Networks, and Sensing Systems (BioWireleSS), Austin, TX, (2016), pp. 84–87. https://doi.org/10.1109/BIOWIRELESS.2016.7445569 M. Abu-Saude, B.I. Morshed, Polypyrrole (PPy) conductive polymer coating of dry patterned vertical CNT (pvCNT) electrode to improve mechanical stability, in 2016 IEEE Topical Conference on Biomedical Wireless Technologies, Networks, and Sensing Systems (BioWireleSS), Austin, TX, (2016), pp. 84–87. https://​doi.​org/​10.​1109/​BIOWIRELESS.​2016.​7445569
25.
29.
go back to reference E. Spinelli, R. Pallàs-Areny, M. Mayosky, AC-coupled front-end for biopotential measurements. IEEE Trans. Biomed. Eng. 50(3), 391–395 (2003). [FILTER] B. Winter, J. Webster, Driven-right-leg circuit design. IEEE Trans. Biomed. Eng. 30(1), 62–66 (1983) E. Spinelli, R. Pallàs-Areny, M. Mayosky, AC-coupled front-end for biopotential measurements. IEEE Trans. Biomed. Eng. 50(3), 391–395 (2003). [FILTER] B. Winter, J. Webster, Driven-right-leg circuit design. IEEE Trans. Biomed. Eng. 30(1), 62–66 (1983)
32.
go back to reference M. Fernandes, K. Lee, R. Ram, J. Correia, P. Mendes, Flexible PDMS-based dry electrodes for electro-optic acquisition of ECG signals in wearable devices, in Proceedings of IEEE Engineering in Medicine and Biology Society (EMBC), (2010), pp. 3503–3506 M. Fernandes, K. Lee, R. Ram, J. Correia, P. Mendes, Flexible PDMS-based dry electrodes for electro-optic acquisition of ECG signals in wearable devices, in Proceedings of IEEE Engineering in Medicine and Biology Society (EMBC), (2010), pp. 3503–3506
33.
go back to reference A. Arcelus, M. Sardar, Mihailidis, Design of a capacitive ECG sensor for unobtrusive heart rate measurements, in IEEE International Instrumentation and Measurement Technology Conference (I2MTC), (2013), pp. 407–410 A. Arcelus, M. Sardar, Mihailidis, Design of a capacitive ECG sensor for unobtrusive heart rate measurements, in IEEE International Instrumentation and Measurement Technology Conference (I2MTC), (2013), pp. 407–410
34.
go back to reference H. Jeong, J. Seo, Electrode design on plastic substrates using laser patterned double-sided tape and gold leaf, in 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Berlin, Germany, (2019), pp. 1286–1289. https://doi.org/10.1109/EMBC.2019.8857635 H. Jeong, J. Seo, Electrode design on plastic substrates using laser patterned double-sided tape and gold leaf, in 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Berlin, Germany, (2019), pp. 1286–1289. https://​doi.​org/​10.​1109/​EMBC.​2019.​8857635
Metadata
Title
Carbon-Based Textile Dry and Flexible Electrodes for ECG Measurement
Authors
Newton Rai
Habibuddin Shaik
N. Veerapandi
Veda Sandeep Nagaraj
S. Veena
Copyright Year
2022
Publisher
Springer Singapore
DOI
https://doi.org/10.1007/978-981-16-1642-6_4