Skip to main content
Top
Published in: International Journal of Computer Assisted Radiology and Surgery 5/2014

01-09-2014 | Original Article

Clinical testing of an alternate method of inserting bone-implanted fiducial markers

Authors: Ramya Balachandran, Mark A. Fritz, Mary S. Dietrich, Andrei Danilchenko, Jason E. Mitchell, Veronica L. Oldfield, Wendy W. Lipscomb, J. Michael Fitzpatrick, Joseph S. Neimat, Peter E. Konrad, Robert F. Labadie

Published in: International Journal of Computer Assisted Radiology and Surgery | Issue 5/2014

Log in

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

Background

   Deep brain stimulation (DBS) surgery utilizes image guidance via bone-implanted fiducial markers to achieve the desired submillimetric accuracy and to provide means for attaching microstereotactic frames. For maximal benefit, the markers must be inserted to the correct depth since over-insertion leads to stripping and under-insertion leads to instability.

Purpose

   The purpose of the study was to test clinically a depth-release drive system, the PosiSeat\(^{\mathrm{TM}}\), versus manual insertion (pilot hole followed by manual screwing until tactile determined correct seating) for implanting fiducial markers into the bone.

Methods

   With institutional review board approval, the PosiSeat\(^{\mathrm{TM}}\) was used to implant markers in 15 DBS patients (57 fiducials). On post-insertion CT scans, the depth of the gap between the shoulder of the fiducial markers and the closest bone surface was measured. Similar depth measurements were performed on the CT scans of 64 DBS patients (250 fiducials), who underwent manual fiducial insertion.

Results

   Median of shoulder-to-bone distance for PosiSeat\(^{\mathrm{TM}}\) and manual insertion group were 0.03 and 1.06 mm, respectively. Fifty percent of the fiducials had the shoulder-to-bone distances within 0.01–0.09 mm range for the PosiSeat group and 0.04–1.45 mm range for the manual insertion group. These differences were statistically significant.

Conclusions

   A depth-release drive system achieves more consistent placement of bone-implanted fiducial markers than manual insertion.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Benabid L, Vercucil L, Benazzouz A, Koudsie A, Chabardes S, Minotti L, Kahane P, Gentil M, Lenartz D, Andressen C, Krack P, Pollak P (2003) Deep brain stimulation: what does it offer? Adv Neurol 91:293–302 Benabid L, Vercucil L, Benazzouz A, Koudsie A, Chabardes S, Minotti L, Kahane P, Gentil M, Lenartz D, Andressen C, Krack P, Pollak P (2003) Deep brain stimulation: what does it offer? Adv Neurol 91:293–302
2.
go back to reference Deuschl G, Wenzelburger R, Kopper F, Volkmann J (2003) Deep brain stimulation of the subthalamic nucleus for Parkinson’s disease: A therapy approaching evidence-based standards. J Neurol 250(1):143–146 Deuschl G, Wenzelburger R, Kopper F, Volkmann J (2003) Deep brain stimulation of the subthalamic nucleus for Parkinson’s disease: A therapy approaching evidence-based standards. J Neurol 250(1):143–146
3.
go back to reference Fitzpatrick JM (2010) The role of registration in accurate surgical guidance. J Eng Med 224(5):607–622CrossRef Fitzpatrick JM (2010) The role of registration in accurate surgical guidance. J Eng Med 224(5):607–622CrossRef
4.
go back to reference Henderson JM (2004) Frameless localization for functional neurosurgical procedures. Stereotact Funct Neurosurg 82:135–141. doi:10.1159/000081345 Henderson JM (2004) Frameless localization for functional neurosurgical procedures. Stereotact Funct Neurosurg 82:135–141. doi:10.​1159/​000081345
5.
go back to reference Konrad PE, Neimat JS, Yu H, Kao CC, Remple MS, D’Haese PF, Dawant BM (2011) Customized, miniature rapid-prototype stereotactic frames for use in deep brain stimulator surgery: initial clinical methodology and experience from 263 patients from 2002 to 2008 study. Stereotact Funct Neurosurg 89(1):34–41PubMedCrossRefPubMedCentral Konrad PE, Neimat JS, Yu H, Kao CC, Remple MS, D’Haese PF, Dawant BM (2011) Customized, miniature rapid-prototype stereotactic frames for use in deep brain stimulator surgery: initial clinical methodology and experience from 263 patients from 2002 to 2008 study. Stereotact Funct Neurosurg 89(1):34–41PubMedCrossRefPubMedCentral
6.
go back to reference Balachandran R, Mitchell JE, Dawant BM (2009) Accuracy evaluation of microtargeting platforms for deep-brain stimulation using virtual targets. IEEE Trans Biomed Eng 56(1):37–44PubMedCrossRef Balachandran R, Mitchell JE, Dawant BM (2009) Accuracy evaluation of microtargeting platforms for deep-brain stimulation using virtual targets. IEEE Trans Biomed Eng 56(1):37–44PubMedCrossRef
7.
go back to reference Maciunas RJ, Galloway RL Jr, Latimer J, Cobb C, Zaccharias E, Moore A, Mandava VR (1992) An independent application accuracy evaluation of stereotactic frame systems. Stereotact Funct Neurosurg 58(1–4):103–107PubMedCrossRef Maciunas RJ, Galloway RL Jr, Latimer J, Cobb C, Zaccharias E, Moore A, Mandava VR (1992) An independent application accuracy evaluation of stereotactic frame systems. Stereotact Funct Neurosurg 58(1–4):103–107PubMedCrossRef
8.
go back to reference Maciunas RJ, Galloway Jr RL, Latimer JW (1994) The application accuracy of stereotactic frames. Neurosurgery 35(4):682–694. (discussion 694–695) Maciunas RJ, Galloway Jr RL, Latimer JW (1994) The application accuracy of stereotactic frames. Neurosurgery 35(4):682–694. (discussion 694–695)
9.
go back to reference Yu C, Apuzzo ML, Zee CS, Petrovich Z (2001) A phantom study of the geometric accuracy of computed tomographic and magnetic resonance imaging stereotactic localization with the Leksell stereotactic system. Neurosurgery 48(5):1092–1098. (discussion 1098–1099) Yu C, Apuzzo ML, Zee CS, Petrovich Z (2001) A phantom study of the geometric accuracy of computed tomographic and magnetic resonance imaging stereotactic localization with the Leksell stereotactic system. Neurosurgery 48(5):1092–1098. (discussion 1098–1099)
10.
go back to reference Bjartmarz H, Rehncrona S (2007) Comparison of accuracy and precision between frame-based and frameless stereotactic navigation for deep brain stimulation electrode implantation. Stereotact Funct Neurosurg 85(5):235–242PubMedCrossRef Bjartmarz H, Rehncrona S (2007) Comparison of accuracy and precision between frame-based and frameless stereotactic navigation for deep brain stimulation electrode implantation. Stereotact Funct Neurosurg 85(5):235–242PubMedCrossRef
11.
go back to reference Henderson JM, Holloway KL, Gaede SE, Rosenow JM (2004) The application accuracy of a skull-mounted trajectory guide system for image-guided functional neurosurgery. Comput Aided Surg 9(4):155–160PubMedCrossRef Henderson JM, Holloway KL, Gaede SE, Rosenow JM (2004) The application accuracy of a skull-mounted trajectory guide system for image-guided functional neurosurgery. Comput Aided Surg 9(4):155–160PubMedCrossRef
12.
go back to reference Aziz TZ, Nandi D, Parkin S, Liu X, Giladi N, Bain P, Gregory RG, Joint C, Scott RB, Stein JF (2001) Targeting the subthalamic nucleus. Stereotact Funct Neurosurg 77:87–90PubMedCrossRef Aziz TZ, Nandi D, Parkin S, Liu X, Giladi N, Bain P, Gregory RG, Joint C, Scott RB, Stein JF (2001) Targeting the subthalamic nucleus. Stereotact Funct Neurosurg 77:87–90PubMedCrossRef
13.
go back to reference Galloway RL, Maciunas RJ (1990) Stereotactic neurosurgery. Crit Rev Biomed Eng 18:181–205PubMed Galloway RL, Maciunas RJ (1990) Stereotactic neurosurgery. Crit Rev Biomed Eng 18:181–205PubMed
14.
go back to reference Mitchell J, Labadie RF, Fitzpatrick JM (2010) Design of a novel device to provide assured seating of bone implanted fiducial markers. J Med Devices 4(2):025002–4CrossRef Mitchell J, Labadie RF, Fitzpatrick JM (2010) Design of a novel device to provide assured seating of bone implanted fiducial markers. J Med Devices 4(2):025002–4CrossRef
15.
go back to reference Liu X, Cevikalp H, Fitzpatrick JM (2003) Marker orientation in fiducial registration. In: Proceedings SPIE Medical Imaging 2003, San Diego, CA, vol 5032. pp 1176–1185 Liu X, Cevikalp H, Fitzpatrick JM (2003) Marker orientation in fiducial registration. In: Proceedings SPIE Medical Imaging 2003, San Diego, CA, vol 5032. pp 1176–1185
16.
go back to reference Kobler JP, Díaz J, Fitzpatrick JM, Lexow GJ, Majdani O, Ortmaier T (in press) Localization accuracy of sphere fiducials in computed tomography images. SPIE Medical Imaging 2014, San Diego, CA Kobler JP, Díaz J, Fitzpatrick JM, Lexow GJ, Majdani O, Ortmaier T (in press) Localization accuracy of sphere fiducials in computed tomography images. SPIE Medical Imaging 2014, San Diego, CA
Metadata
Title
Clinical testing of an alternate method of inserting bone-implanted fiducial markers
Authors
Ramya Balachandran
Mark A. Fritz
Mary S. Dietrich
Andrei Danilchenko
Jason E. Mitchell
Veronica L. Oldfield
Wendy W. Lipscomb
J. Michael Fitzpatrick
Joseph S. Neimat
Peter E. Konrad
Robert F. Labadie
Publication date
01-09-2014
Publisher
Springer Berlin Heidelberg
Published in
International Journal of Computer Assisted Radiology and Surgery / Issue 5/2014
Print ISSN: 1861-6410
Electronic ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-014-0980-5

Other articles of this Issue 5/2014

International Journal of Computer Assisted Radiology and Surgery 5/2014 Go to the issue

Premium Partner