Skip to main content
Top

2019 | OriginalPaper | Chapter

Compact Solar Air Heater: A Review

Authors : Vijay Singh Bisht, Anil Kumar Patil, Anirudh Gupta

Published in: Advances in Fluid and Thermal Engineering

Publisher: Springer Singapore

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

In this review work, a theoretical study of solar air heater is carried out by considering compact heat exchanger criteria into account. The present investigation comprises different performance parameters for a compact solar air heater. In this review work, Reynolds number is the only variable parameter which varies from 4000 to 18000. Stanton number (St), Stanton number ratio (St/St0), Colburn factor (j), and area goodness factor (j/f) are considered as performance parameters. Stanton number ratio (St/St0) is maximum for multi-V-shaped ribs with gaps. Colburn factor (j) value is highest for multi-V-shaped ribs with gaps. In the present investigation, goodness factor (j/f) is highest for circular protrusions organized in angular arc form. This study is beneficial for the researchers to conduct the experimental and theoretical investigation in order to search out the new roughness geometries to design compact solar air heater.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Prasad BN, Saini JS (1988) Effect of artificial roughness on heat transfer and friction factor in a solar air heater. Sol Energy 41:555–560CrossRef Prasad BN, Saini JS (1988) Effect of artificial roughness on heat transfer and friction factor in a solar air heater. Sol Energy 41:555–560CrossRef
2.
go back to reference Taslim ME, Li T, Kercher DM (1996) Experimental heat transfer and friction in channels roughened with angled, V-shaped and discrete ribs on two opposite walls. ASME Journal of Turbomachinery 118:20–28CrossRef Taslim ME, Li T, Kercher DM (1996) Experimental heat transfer and friction in channels roughened with angled, V-shaped and discrete ribs on two opposite walls. ASME Journal of Turbomachinery 118:20–28CrossRef
3.
go back to reference Momin AME, Saini JS, Solanki SC (2002) Heat transfer and friction in solar air heater duct with V-shaped rib roughness on absorber plate. Int J Heat Mass Transf 45:3383–3396CrossRef Momin AME, Saini JS, Solanki SC (2002) Heat transfer and friction in solar air heater duct with V-shaped rib roughness on absorber plate. Int J Heat Mass Transf 45:3383–3396CrossRef
4.
go back to reference Bhagoria JL, Saini JS, Solanki SC (2002) Heat transfer coefficient and friction factor correlations for rectangular solar air heater duct having transverse wedge shaped rib roughness on the absorber plate. Renew Energy 25:341–369CrossRef Bhagoria JL, Saini JS, Solanki SC (2002) Heat transfer coefficient and friction factor correlations for rectangular solar air heater duct having transverse wedge shaped rib roughness on the absorber plate. Renew Energy 25:341–369CrossRef
5.
go back to reference Jaurker AR, Saini JS, Gandhi BK (2006) Heat transfer and friction characteristics of rectangular solar air heater duct using rib-grooved artificial roughness. Sol Energy 280:895–907CrossRef Jaurker AR, Saini JS, Gandhi BK (2006) Heat transfer and friction characteristics of rectangular solar air heater duct using rib-grooved artificial roughness. Sol Energy 280:895–907CrossRef
6.
go back to reference Saini SK, Saini RP (2008) Development of correlations for Nusselt number and friction factor for solar air heater with roughened duct having arc-shaped wire as artificial roughness. Sol Energy 82:1118–1130CrossRef Saini SK, Saini RP (2008) Development of correlations for Nusselt number and friction factor for solar air heater with roughened duct having arc-shaped wire as artificial roughness. Sol Energy 82:1118–1130CrossRef
7.
go back to reference Hans VS, Saini RP, Saini JS (2010) Heat transfer and friction factor correlations for a solar air heater duct roughened artificially with multiple V-ribs. Sol Energy 84:898–911CrossRef Hans VS, Saini RP, Saini JS (2010) Heat transfer and friction factor correlations for a solar air heater duct roughened artificially with multiple V-ribs. Sol Energy 84:898–911CrossRef
8.
go back to reference Lanjewar A, Bhagoria JL, Sarviya RM (2011) Heat transfer and friction in solar air heater duct with W-shaped rib roughness on absorber plate. Energy 36:4531–4541CrossRef Lanjewar A, Bhagoria JL, Sarviya RM (2011) Heat transfer and friction in solar air heater duct with W-shaped rib roughness on absorber plate. Energy 36:4531–4541CrossRef
9.
go back to reference Sethi M, Varun Thakur NS (2012) Correlations for solar air heater duct with dimpled shape roughness elements on absorber plate. Solar Energy 86:2852–2861CrossRef Sethi M, Varun Thakur NS (2012) Correlations for solar air heater duct with dimpled shape roughness elements on absorber plate. Solar Energy 86:2852–2861CrossRef
10.
go back to reference Yadav S, Kaushal M (2013) Varun, Siddhartha, Nusselt number and friction factor correlationsfor solar air heater duct having protrusions as roughness elements on absorber plate. Exp Thermal Fluid Sci 44:34–41CrossRef Yadav S, Kaushal M (2013) Varun, Siddhartha, Nusselt number and friction factor correlationsfor solar air heater duct having protrusions as roughness elements on absorber plate. Exp Thermal Fluid Sci 44:34–41CrossRef
11.
go back to reference Kumar A, Saini RP, Saini JS (2013) Development of correlations for Nusselt number and friction factor for solar air heater with roughened duct having multi v-shaped with gap rib as artificial roughness. Renew Energy 58:151–163CrossRef Kumar A, Saini RP, Saini JS (2013) Development of correlations for Nusselt number and friction factor for solar air heater with roughened duct having multi v-shaped with gap rib as artificial roughness. Renew Energy 58:151–163CrossRef
12.
go back to reference Singh AP, Varun, Siddhartha (2014) Heat transfer and friction factor correlations for multiple arc shape roughness elements on the absorber plate used in solar air heaters. Exp Thermal Fluid Sci 54: 117–126 Singh AP, Varun, Siddhartha (2014) Heat transfer and friction factor correlations for multiple arc shape roughness elements on the absorber plate used in solar air heaters. Exp Thermal Fluid Sci 54: 117–126
13.
go back to reference Gawande VB, Dhoble AS, Zodpe DB, Chamoli S (2016) Experimental and CFD investigation of convection heat transfer in solar air heater with reverse L shaped ribs. Sol Energy 131:275–295CrossRef Gawande VB, Dhoble AS, Zodpe DB, Chamoli S (2016) Experimental and CFD investigation of convection heat transfer in solar air heater with reverse L shaped ribs. Sol Energy 131:275–295CrossRef
14.
go back to reference Bejan A, Kraus AD (2003) Heat transfer handbook, 3rd edn. Wiley & Sons, New York Bejan A, Kraus AD (2003) Heat transfer handbook, 3rd edn. Wiley & Sons, New York
15.
go back to reference Kays WM, London AL (1984) Compact heat exchangers, 3rd edn. McGraw-Hill, New York Kays WM, London AL (1984) Compact heat exchangers, 3rd edn. McGraw-Hill, New York
16.
go back to reference Bisht VS, Patil AK, Gupta A (2018) Review and performance evaluation of roughened solar air heaters. Renew Sustain Energy Rev 81(1):954–977CrossRef Bisht VS, Patil AK, Gupta A (2018) Review and performance evaluation of roughened solar air heaters. Renew Sustain Energy Rev 81(1):954–977CrossRef
Metadata
Title
Compact Solar Air Heater: A Review
Authors
Vijay Singh Bisht
Anil Kumar Patil
Anirudh Gupta
Copyright Year
2019
Publisher
Springer Singapore
DOI
https://doi.org/10.1007/978-981-13-6416-7_26

Premium Partners