Abstract

In this paper, the authors propose the mathematical model in Park reference frame of squirrel cage induction machine with dual open-end windings. A comparison between open-end stator winding induction machines and star winding induction machines is presented. In this comparison, the authors take into consideration the power segmentation, redundancy degrees in degraded mode, the THD current and the torque undulation.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Ben Ammar F, Sami G (2008) The improvement availability of a double star asynchronous machine supplied by redundant voltage source inverter. J Electr Syst 4(4) Ben Ammar F, Sami G (2008) The improvement availability of a double star asynchronous machine supplied by redundant voltage source inverter. J Electr Syst 4(4)
2.
go back to reference Blanke M, Sandberg T (2006) Electrical steering of vehicles-fault-tolerant analysis and design. Elsevier Microelectron Reliab 46:1421–1432CrossRef Blanke M, Sandberg T (2006) Electrical steering of vehicles-fault-tolerant analysis and design. Elsevier Microelectron Reliab 46:1421–1432CrossRef
3.
go back to reference Abbas MA, Christen R, Jahns TM (1984) Six-phase voltage source inverter driven induction motor. IEEE Trans Ind Appl IA–20:1251–1259CrossRef Abbas MA, Christen R, Jahns TM (1984) Six-phase voltage source inverter driven induction motor. IEEE Trans Ind Appl IA–20:1251–1259CrossRef
4.
go back to reference Singh GK, Pant V, Singh YP (2003) Voltage source inverter driven multi-phase induction machine. J Comput Electr Eng Elsevier 29:813–834CrossRefMATH Singh GK, Pant V, Singh YP (2003) Voltage source inverter driven multi-phase induction machine. J Comput Electr Eng Elsevier 29:813–834CrossRefMATH
5.
go back to reference Abdel-Khalik AS, Masoud MI, Williams BW (2012) Vector controlled multiphase induction machine: harmonic injection using optimized constant gains. Elsevier Electr Power Syst Res 89:116–128CrossRef Abdel-Khalik AS, Masoud MI, Williams BW (2012) Vector controlled multiphase induction machine: harmonic injection using optimized constant gains. Elsevier Electr Power Syst Res 89:116–128CrossRef
6.
go back to reference Lipo TA, Munoz-Garcia AR, Dual stator winding induction machine drive. United States Patent 6, 242-884 Lipo TA, Munoz-Garcia AR, Dual stator winding induction machine drive. United States Patent 6, 242-884
7.
go back to reference Zhao Y, Lipo TA (1995) Space vector PWM control of dual three-phase induction machine using vector space decomposition. IEEE Trans Ind Appl 31:1100–1109CrossRef Zhao Y, Lipo TA (1995) Space vector PWM control of dual three-phase induction machine using vector space decomposition. IEEE Trans Ind Appl 31:1100–1109CrossRef
8.
go back to reference Rojoi R, Farina F, Griva G, Profumo R, Tenconi A (2005) Direct torque control for dual three-phase induction motors drives. IEEE Trans Ind Appl 41:1627–1636CrossRef Rojoi R, Farina F, Griva G, Profumo R, Tenconi A (2005) Direct torque control for dual three-phase induction motors drives. IEEE Trans Ind Appl 41:1627–1636CrossRef
9.
go back to reference Somasekhar VT, Baiju MR, Gopakumar K (2004) Dual two-level inverter scheme for an open-end winding induction motor drive with a single DC power supply and improved DC bus utilization. IEEE Proc Electr Power Appl 151:230–238CrossRef Somasekhar VT, Baiju MR, Gopakumar K (2004) Dual two-level inverter scheme for an open-end winding induction motor drive with a single DC power supply and improved DC bus utilization. IEEE Proc Electr Power Appl 151:230–238CrossRef
10.
go back to reference Mondal G, Gopakumar K, Tekwani PN, Levi E (2007) A reduced-switch-count five-level inverter with common-mode voltage elimination for an open-end winding induction motor drive. IEEE Trans Ind Electron 54:2344–2351CrossRef Mondal G, Gopakumar K, Tekwani PN, Levi E (2007) A reduced-switch-count five-level inverter with common-mode voltage elimination for an open-end winding induction motor drive. IEEE Trans Ind Electron 54:2344–2351CrossRef
11.
go back to reference Srinivas S, Somasekhar VT (2008) Space-vector-based PWM switching strategies for a three-level dual-inverter-fed open-end winding induction motor drive and their comparative evaluation. IET Electr Power Appl 2:19–31CrossRef Srinivas S, Somasekhar VT (2008) Space-vector-based PWM switching strategies for a three-level dual-inverter-fed open-end winding induction motor drive and their comparative evaluation. IET Electr Power Appl 2:19–31CrossRef
12.
go back to reference Figarado S, Sivakumar K, Ramchand R, Das A, Patel C, Gopakumar K (2010) Five-level inverter scheme for an open-end winding induction machine with less number of switches. IET Power Electron 3:637–647CrossRef Figarado S, Sivakumar K, Ramchand R, Das A, Patel C, Gopakumar K (2010) Five-level inverter scheme for an open-end winding induction machine with less number of switches. IET Power Electron 3:637–647CrossRef
13.
go back to reference Nayli A, Guizani S, Ben Ammar F (2013) Open-end winding induction machine supplied by two flying capacitor multilevel inverters. In: ICEESA (2013) Hammamet, Tunisia Nayli A, Guizani S, Ben Ammar F (2013) Open-end winding induction machine supplied by two flying capacitor multilevel inverters. In: ICEESA (2013) Hammamet, Tunisia
14.
go back to reference Guizani S, Nayli A, Ben Ammar F (2014) Fault-tolerant control for open-end stator winding induction machine supplied by two three phase cascaded inverters with one failed inverter. J Electr Eng 14(1) Guizani S, Nayli A, Ben Ammar F (2014) Fault-tolerant control for open-end stator winding induction machine supplied by two three phase cascaded inverters with one failed inverter. J Electr Eng 14(1)
15.
go back to reference Guizani S, Ben Ammar F (2013) The dual open-end winding induction machine fed by quad inverters in degraded mode. Int J Sci Eng Res 4:2229–5518 Guizani S, Ben Ammar F (2013) The dual open-end winding induction machine fed by quad inverters in degraded mode. Int J Sci Eng Res 4:2229–5518
16.
go back to reference Guizani S, Ben Ammar F (2015) Dual open-end stator winding IM fed by redundant voltage source inverters. Turk J Electr Eng Comput Sci 23:2171–2181CrossRef Guizani S, Ben Ammar F (2015) Dual open-end stator winding IM fed by redundant voltage source inverters. Turk J Electr Eng Comput Sci 23:2171–2181CrossRef
Metadata
Title
Comparison between star winding and open-end winding induction machines
Publication date
20-02-2016
Published in
Electrical Engineering / Issue 3/2016
Print ISSN: 0948-7921
Electronic ISSN: 1432-0487
DOI
https://doi.org/10.1007/s00202-016-0359-4

Other articles of this Issue 3/2016

Electrical Engineering 3/2016 Go to the issue