Composite Wood–Concrete Structural Floor System with Horizontal Connectors

Authors: Ruy A. SáRibeiro, Marilene G. SáRibeiro

Published in: International Journal of Concrete Structures and Materials | Issue 1/2015

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

The concept of horizontal shear connection utilization on wood–concrete beams intends to be an alternative connection detail for composite wood–concrete decks. The volume of sawn-wood is over three times more expensive than concrete, in Brazil. In order to be competitive in the Brazilian market we need a composite deck with the least amount of wood and a simple and inexpensive connection detail. This research project uses medium to high density tropical hardwoods managed from the Brazilian Amazon region and construction steel rods. The beams studied are composed of a bottom layer of staggered wood boards and a top layer of concrete. The wood members are laterally nailed together to form a wide beam, and horizontal rebar connectors are installed before the concrete layer is applied on top. Two sets of wood–concrete layered beams with horizontal rebar connectors (6 and 8) were tested in third-point loading flexural bending. The initial results reveal medium composite efficiency for the beams tested. An improvement on the previously conceived connection detail (set with six connectors) for the composite wood–concrete structural floor system was achieved by the set with eight connectors. The new layout of the horizontal rebar connectors added higher composite efficiency for the beams tested. Further analysis with advanced rigorous numerical Finite Element Modeling is suggested to optimize the connection parameters. Composite wood–concrete decks can attend a large demand for pedestrian bridges, as well as residential and commercial slabs in the Brazilian Amazon.

1 Introduction

In spite of the existence of more than 2,500 different wood species catalogued in the Brazilian Amazon (SáRibeiro and SáRibeiro 1990), wood is very little used in Brazil as an engineered structural element (excluding conventional structures for residential roofs). Engineered wood structures are largely used in the developed countries for constructions of schools, churches, commercial and industrial buildings, residences, pavilions, highway and railway bridges, towers, theater screens, ships, military and marine installations.
The conventional construction of a reinforced concrete slab presents a high degree of wasted materials, and the steel reinforcement is expensive. The tension zone cracks and half of its thickness is ineffective, only holding the steel reinforcement in place (Gutkowski et al. 2000). The tension cracks can allow access to moisture, causing corrosion, separation, and other types of degeneration. Exposed rebar is also a potential problem for fire protection.
This research aims to substitute part of the concrete and the expensive rebar by a solid Amazonian wood deck structurally effective. Since the wood deck can substitute the normal formwork, the gain is leaving it in place, reducing in half the thickness of the slab and interconnecting them. This also results in economy of the construction cost. The competitive merit of this mixed construction is supported by several examples of successful pilot projects in Europe and in the USA (Gutkowski et al. 2000, 1999a, b, 2001, 2002, 2004, 2008; Gutkowski and Chen 1996; Brown 1998; Brown et al. 1998; Chen et al. 1992; Etournaud 1998; Etournaud et al. 1998; Fragiacomo et al. 2007; Fragiacomo and Ceccotti 2006; Fragiacomo 2006; Ceccotti et al. 2006; Faggiano et al. 2009), and more recently in Brazil (SáRibeiro et al. 2006). In the recent decade the mixed construction has advanced to many constructions in Europe of multi-story apartment buildings, office buildings and some bridge decks (Grantham et al. 2004; Clouston and Schreyer 2008). Nowadays actual buildings are going up and Euro code provisions exist in detail for their design (Clouston and Schreyer 2008; Comité Européen de Normalisation 2002, 2003, 2004; Lukaszewska et al. 2008; Dias et al. 2011; Fragiacomo and Batchelar 2012; Fragiacomo and Schänzlin 2013).
The objective of this work is to study the effectiveness of this connection detail, which is easy to fabricate (uses unskilled labor and handy tools) and has a low cost (uses conventional available low cost materials). The horizontal shear connection concept intends to be another alternative to be used for composite wood–concrete decks. This experiment used mid to high density tropical hardwoods managed from the Brazilian Amazon region and 10-mm diameter construction steel rods.

2 Connection Detail

In order to achieve a high degree of composite action the interlayer connections must reduce slip to low magnitude. The flexure of layered elements results in a tendency for relative longitudinal motion at their interface.
The shear connection detail achieves interlayer shear transfer by bearing stresses and horizontal shear in the drilled wood holes (Fig. 1). Since interlayer slip is low, the anchor connector itself is not subjected to shear. It only resists uplift created by the bearing force in the wood holes. The connection for this experiment used steel rod couples embedded into pre-drilled holes across the laminated wood beam. Further details are presented in Sect. 3.

3 Experimental Procedures

3.1 Beam Specimens

Two sets of three wood–concrete layered beams, each, were tested. Each beam represented a portion of the width of a layered wood concrete longitudinal deck specimen.
For set-1 (with six connectors), all staggered wood deck for beams V1 and V2 was Mandioqueira (Qualea acuminata), and for V3 was Angelim-pedra (Hymenolobium petraceum) in the outer layers and Mandioqueira in the middle layer. The wood was surfaced dry, 50 × 75 mm and 50 × 38 mm nominal size dimension lumber tested at an average 15 % moisture content (MC) condition. The average specific gravity of the wood, at 15 % MC, was 0.74. The layered wood beam section used was a 3.05-m beam, composed of five vertical pieces of two alternating depths. Wood members were laterally nailed together with 80-mm long galvanized spiral-shank nails in the vertical pattern shown in Fig. 2 as nails 1 through 4. This pattern was repeated every 300 mm along the beam and at mid-span. In order to accommodate the horizontal shear connectors (10-mm diameter construction steel rods), two 12-mm diameter holes, spaced 100 mm on-center, were pre-drilled at the mid-length and at 300 mm from both ends of the 250-mm wide beams. The holes penetrated the full thickness of the center-layer wood member, and just half the thickness of the outer-layer wood members. The steel rod connectors were set in place before nailing the last outer-layer wood member, as shown in Fig. 1. Concrete formwork was constructed around the beams using 12-mm thick plywood, to accommodate a 30-mm deep top concrete lamina (Fig. 3).
For set-2 (with eight connectors), all staggered wood deck for beams MAN1, MAN2 and MAN4 was Mandioqueira (Q. acumminata) on the outer layers and in the middle layer. The wood was surfaced dry, 50 × 100 mm and 50 × 50 mm nominal size dimension lumber tested at an average 12 % MC condition. The layered wood beam section used was a 3.05-m beam, composed of five staggered vertical pieces (Fig. 1). Wood members were laterally nailed together, the same way as it was done for set 1 (Fig. 2; Tables 1 and 2). In order to accommodate the horizontal shear connectors (10-mm diameter construction steel rods), two 12-mm diameter holes, spaced 100 mm on-center, were pre-drilled at 300 mm and at 700 mm from both ends of the 250-mm wide beams. Each connector was set in place before nailing the last outer-layer wood member (Fig. 2). Concrete formwork was constructed around the beams using 12-mm thick plywood, as shown in Fig. 3.
Table 1
Beams sectional dimensions.
SET
b w (mm)
d w (mm)
d c (mm)
b (mm)
d (mm)
L (m)
1
50
75
30
250
105
3.000
2
50
100
30
250
130
3.000
Table 2
Nailing steps (10-mm apart) and paired connector details (100-mm apart).
SET
Nail ①②③④
Paired connector ⑤
Spacing (mm)
Edge dist. (mm)
Spacing o-c (mm)
Edge dist. (mm)
Length (mm)
1
300
25
1,425
25
175
2
250–300
50
400
300
175
The mechanical properties of the construction steel rods used are: modulus of elasticity, E = 200,100 MPa, and yield strength, f y  = 250 MPa. All wood members were nondestructively tested using the Metriguard Stress Wave Timer device to determine the longitudinal modulus of elasticity, E d . The average values of E d for sets 1 and 2 were found to be 11,887 and 15,491 MPa, respectively.
The concrete layers for sets 1 and 2 were batch delivered with 18 and 10 MPa specified strength (average values of three cylinders tested at the 28th day), respectively, consolidated by vibration and moist cured. After curing of the concrete the wood–concrete beams were transported to the laboratory for testing.

3.2 Beam Tests

Testing was done using an Instron Universal Testing Machine with a 500-kN load cell capacity (set 1) and an Instron Actuator attached to a Test Frame with a 250-kN calibrated load cell capacity (set 2) at a speed of 10 mm/min up to rupture. Beam specimens were loaded with a third point loading and simply supported over a 3.0-m clear span. Deflections were measured at mid-span using potentiometers (Figs. 4 and 5). Also, measurements of slip between the wood and concrete layers were taken at both ends of each beam (Figs. 4 and 5). The potentiometers were Celesco position transducers with a measuring range of 254 mm and a position sensitivity of 94 mV/V/inch. The testing procedure was the following:
(1)
Connect the potentiometers to the beam.
 
(2)
Apply third point loading at a load rate of 10 mm/min up to rupture, using an Instron Universal Testing Machine (set 1) and an Instron Actuator attached to a Test Frame (set 2). Measure and record displacements and load. Load and displacements are measured from LabView VI.
 

4 Analysis and Results

The experiment for set 1 used 6 connectors per 0.75 m2 (top horizontal surface) for each beam, while for set 2 used eight connectors. All beams tested showed tensile failure in the wood and shearing of the concrete (Fig. 6). The tensile failure in the wood was mainly due to cross grain. A plot for the load–displacement of the beams tested on third-point loading flexural bending is depicted in Fig. 7. The registration of the same load value at the sixth point of set 1 may be due to an instant disturbance of the loading instrumentation. However, this single episode was considered not to be detrimental to the overall testing results.
Efficiency of the layered beams in developing composite action was determined using an established definition (Pault and Gutkowski 1977),
E f f i c i e n c y = D n c - D m D n c - D f c × 100
(1)
where D nc is the theoretical non-composite deflection, D fc is the theoretical fully composite deflection, and D m is the measured deflection for incomplete composite action of the specimen. D nc is computed as a layered beam without shear transfer,
D n c = 23 P u L 3 648 E w I w + E c I c
(2)
where P u is the ultimate load, L is the span, E w and I w are, respectively, the wood modulus of elasticity and moment of inertia, E c and I c are, respectively, the concrete modulus of elasticity and moment of inertia. D fc is calculated by the transformed section,
D f c = 23 P u L 3 648 E w I t r
(3)
where I tr is the transformed section moment of inertia. The values for Eqs. (1) to (3) are given in Table 3.
Table 3
Composite efficiency of the composite beams from set 2.
BEAM
P u (N)
D max (mm)
D fc (mm)
D nc (mm)
CEF (%)
MAN1
32,929
97.85
17.7
160.4
43.84
MAN2
31,151
93.93
16.8
151.7
42.83
MAN4
22,567
57.39
12.2
109.9
53.73
AVG
28,882
83.1
15.6
140.7
46.80
SD
5,541
22.3
3.0
27.0
6.02
COV (%)
19.19
26.86
19.19
19.19
12.87
The three beams tested with eight horizontal shear connectors (set 2) presented an average 47 % degree of composite action efficiency. Previous tests with six horizontal shear connectors (set 1) resulted in 32 % of composite action efficiency (SáRibeiro et al. 2006). The test of the three wood–concrete beams with eight horizontal shear connectors and medium to high density tropical hardwoods showed a composite system 47 % more efficient than the pilot test with six horizontal shear connectors (SáRibeiro et al. 2006).

5 Discussion and Conclusions

It is possible to achieve a reasonable degree of composite action (for short term ramp loading) in layered wood concrete deck specimens using nominal dimension lumber and a horizontal shear anchor detail. An improvement on the previously conceived connection detail (set with six connectors) for the composite wood–concrete structural floor system was achieved by the set with eight connectors. The new layout of the horizontal rebar connectors added higher composite efficiency for the beams tested. The results reveal increased medium composite efficiency for the beams tested. Further analysis with advanced rigorous numerical Finite Element Modeling is suggested to optimize the connection parameters in terms of spacing and number of connectors. Composite wood–concrete decks can attend a large demand for pedestrian and road bridges in rural areas, as well as residential and commercial slabs. Durability under repetitive loads and extremes of temperature and humidity need to be examined, particularly for possible applications in bridge decks. This can be achieved using rigorous time-dependent and long term 3D models of sustained and repeated loading to demonstrate the performance over time of the connection detail (Fragiacomo and Ceccotti 2006; Fragiacomo 2006; Ceccotti et al. 2006).
Two important non-technical benefits of the mixed material construction are cost savings of replacing nonrenewable resource based concrete and steel with a managed renewable resource; and savings in energy of material production and construction. Changes from concrete and steel to more wood construction can substantially reduce energy requirements and carbon dioxide emissions (Natterer 1997; Wegener and Zimmer 1998; Winter 1998). These realities and the outcome of this study encourage considering the feasibility of wood concrete composites as a new application of dimension lumber in Brazil.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.
Literature
go back to reference Brown, K. T. (1998). Testing of a Shear Key/Anchor in Layered Wood/Concrete Beams. M. S. Thesis, Department of Civil Engineering, Colorado State University, Ft. Collins, CO. Brown, K. T. (1998). Testing of a Shear Key/Anchor in Layered Wood/Concrete Beams. M. S. Thesis, Department of Civil Engineering, Colorado State University, Ft. Collins, CO.
go back to reference Brown, K. T., Gutkowski, R. M., Criswell, M. E., & Peterson, M. L. (1998). Testing of a shear key/anchor in layered wood/concrete beams, Structural Research Report No. 76, Civil Engineering Department, Colorado State University, Ft. Collins, CO. Brown, K. T., Gutkowski, R. M., Criswell, M. E., & Peterson, M. L. (1998). Testing of a shear key/anchor in layered wood/concrete beams, Structural Research Report No. 76, Civil Engineering Department, Colorado State University, Ft. Collins, CO.
go back to reference Ceccotti, A., Fragiacomo, M., & Giordano, S. (2006). Long-term and collapse tests on a timber–concrete composite beam with glued-in connection. Materials and Structures,40, 15–25.CrossRef Ceccotti, A., Fragiacomo, M., & Giordano, S. (2006). Long-term and collapse tests on a timber–concrete composite beam with glued-in connection. Materials and Structures,40, 15–25.CrossRef
go back to reference Chen, T.-M., Gutkowski, R. M., & Pellicane, P. J. (1992). Tests and analysis of mixed wood–concrete wood beams, Structural Research Report No. 69, Civil Engineering Department, Colorado State University, Ft. Collins, CO. Chen, T.-M., Gutkowski, R. M., & Pellicane, P. J. (1992). Tests and analysis of mixed wood–concrete wood beams, Structural Research Report No. 69, Civil Engineering Department, Colorado State University, Ft. Collins, CO.
go back to reference Clouston, P., & Schreyer, A. (2008). Design and use of wood–concrete composites. Practice Periodical on Structural Design and Construction,13(4), 167–174.CrossRef Clouston, P., & Schreyer, A. (2008). Design and use of wood–concrete composites. Practice Periodical on Structural Design and Construction,13(4), 167–174.CrossRef
go back to reference CEN, Comité Européen de Normalisation. (2002). Eurocode—Basis of structural design. EN 1990. Brussels, Belgium. CEN, Comité Européen de Normalisation. (2002). EurocodeBasis of structural design. EN 1990. Brussels, Belgium.
go back to reference CEN, Comité Européen de Normalisation. (2003). Eurocode 5—Design of timber structures. EN 1995-1. Brussels, Belgium. CEN, Comité Européen de Normalisation. (2003). Eurocode 5Design of timber structures. EN 1995-1. Brussels, Belgium.
go back to reference CEN, Comité Européen de Normalisation. (2004). Eurocode 5—Design of timber structures. EN 1995-2. Brussels, Belgium. CEN, Comité Européen de Normalisation. (2004). Eurocode 5Design of timber structures. EN 1995-2. Brussels, Belgium.
go back to reference Dias, A. M. P. G., Ferreira, M. C. P., Jorge, L. F. C., & Martins, H. M. G. (2011). Timber–concrete practical applications-bridge case study. Proceedings of the Institution of Civil Engineers: Structures and Buildings,164(2), 131–141. Dias, A. M. P. G., Ferreira, M. C. P., Jorge, L. F. C., & Martins, H. M. G. (2011). Timber–concrete practical applications-bridge case study. Proceedings of the Institution of Civil Engineers: Structures and Buildings,164(2), 131–141.
go back to reference Etournaud, P. A. (1998). Loads Tests of Composite Wood–Concrete Deckings Under Point Loads. M. S. Thesis, Department of Civil Engineering, Colorado State University, Ft. Collins, CO. Etournaud, P. A. (1998). Loads Tests of Composite Wood–Concrete Deckings Under Point Loads. M. S. Thesis, Department of Civil Engineering, Colorado State University, Ft. Collins, CO.
go back to reference Etournaud, P. A., Gutkowski, R. M., Peterson, M. L., & Criswell, M. E. (1998). Loads tests of composite wood–concrete deckings under point loads, Structural Research Report No. 81, Civil Engineering Department, Colorado State University, Ft. Collins, CO. Etournaud, P. A., Gutkowski, R. M., Peterson, M. L., & Criswell, M. E. (1998). Loads tests of composite wood–concrete deckings under point loads, Structural Research Report No. 81, Civil Engineering Department, Colorado State University, Ft. Collins, CO.
go back to reference Faggiano, B., Marzo, A., Mazzolani, F. M., & Calado, L. M. (2009). Analysis of rectangular-shaped collar connectors for Composite timber–steel–concrete floors: Push-out tests. Journal of Civil Engineering and Management,15(1), 47–58.CrossRef Faggiano, B., Marzo, A., Mazzolani, F. M., & Calado, L. M. (2009). Analysis of rectangular-shaped collar connectors for Composite timber–steel–concrete floors: Push-out tests. Journal of Civil Engineering and Management,15(1), 47–58.CrossRef
go back to reference Fragiacomo, M. (2006). Long-term behavior of timber–concrete composite beams. II: Numerical analysis and simplified evaluation. Journal of Structural Engineering,132(1), 23–33.CrossRef Fragiacomo, M. (2006). Long-term behavior of timber–concrete composite beams. II: Numerical analysis and simplified evaluation. Journal of Structural Engineering,132(1), 23–33.CrossRef
go back to reference Fragiacomo, M., & Batchelar, M. (2012). Timber frame moment joints with glued-in steel rods. II: Experimental investigation of long-term performance. Journal of Structural Engineering,138(6), 802–811.CrossRef Fragiacomo, M., & Batchelar, M. (2012). Timber frame moment joints with glued-in steel rods. II: Experimental investigation of long-term performance. Journal of Structural Engineering,138(6), 802–811.CrossRef
go back to reference Fragiacomo, M., & Ceccotti, A. (2006). Long-term behavior of timber–concrete composite beams. I: Finite Element Modeling and validation. Journal of Structural Engineering,132(1), 13–22.CrossRef Fragiacomo, M., & Ceccotti, A. (2006). Long-term behavior of timber–concrete composite beams. I: Finite Element Modeling and validation. Journal of Structural Engineering,132(1), 13–22.CrossRef
go back to reference Fragiacomo, M., Gutkowski, R. M., Balogh, J., & Fast, R. S. (2007). Long-term behavior of wood–concrete composite floor/deck systems with shear key connection detail. Journal of Structural Engineering,133(9), 1307–1315.CrossRef Fragiacomo, M., Gutkowski, R. M., Balogh, J., & Fast, R. S. (2007). Long-term behavior of wood–concrete composite floor/deck systems with shear key connection detail. Journal of Structural Engineering,133(9), 1307–1315.CrossRef
go back to reference Fragiacomo, M., & Schänzlin, J. (2013). Proposal to account for environmental effects in design of timber–concrete composite beams. Journal of Structural Engineering,139(1), 162–167.CrossRef Fragiacomo, M., & Schänzlin, J. (2013). Proposal to account for environmental effects in design of timber–concrete composite beams. Journal of Structural Engineering,139(1), 162–167.CrossRef
go back to reference Grantham, R., Enjily, V., Fragiacomo, M., Nogarol, C., Zidaric, I., & Amadio, C. (2004). Potential upgrade of timber frame buildings in the UK using timber–concrete composites. In Proceedings8th World Conference on Timber Engineering. Lahti, Finland. Grantham, R., Enjily, V., Fragiacomo, M., Nogarol, C., Zidaric, I., & Amadio, C. (2004). Potential upgrade of timber frame buildings in the UK using timber–concrete composites. In Proceedings8th World Conference on Timber Engineering. Lahti, Finland.
go back to reference Gutkowski, R. M., Balogh, J., Natterer, J., Brown, K., Koike, E., & Etournaud, P. (2000). Laboratory tests of composite wood–concrete beam and floor specimens. In Proceedings of World Conference on Timber Engineering2000. Whisthler Resort, BC, Canada. Gutkowski, R. M., Balogh, J., Natterer, J., Brown, K., Koike, E., & Etournaud, P. (2000). Laboratory tests of composite wood–concrete beam and floor specimens. In Proceedings of World Conference on Timber Engineering2000. Whisthler Resort, BC, Canada.
go back to reference Gutkowski, R. M., Balogh, J., Rogers, C. C., & SaRibeiro, R. A. (2002). Laboratory tests of deep composite wood–concrete beam and deck specimens. In Proceedings of the 4th Structural Specialty Conference of the Canadian Society of Civil Engineering (pp. 1–9). Quebec, Canada: 30th Annual CSCE Conference Montreal. Gutkowski, R. M., Balogh, J., Rogers, C. C., & SaRibeiro, R. A. (2002). Laboratory tests of deep composite wood–concrete beam and deck specimens. In Proceedings of the 4th Structural Specialty Conference of the Canadian Society of Civil Engineering (pp. 1–9). Quebec, Canada: 30th Annual CSCE Conference Montreal.
go back to reference Gutkowski, R. M., Balogh, J., SaRibeiro, R. A. (2001). Modeling and testing of composite wood–concrete deep beam specimens. In Proceedings of STRUCTURAL FAULTS + REPAIR—01, 10th International Conference and Exhibition. London, UK. Gutkowski, R. M., Balogh, J., SaRibeiro, R. A. (2001). Modeling and testing of composite wood–concrete deep beam specimens. In Proceedings of STRUCTURAL FAULTS + REPAIR01, 10th International Conference and Exhibition. London, UK.
go back to reference Gutkowski, R. M., Brown, K., Shigidi, A., & Natterer, J. (2004). Investigation of notched composite wood–concrete connections. Construction and Building Materials,22, 1059–1066.CrossRef Gutkowski, R. M., Brown, K., Shigidi, A., & Natterer, J. (2004). Investigation of notched composite wood–concrete connections. Construction and Building Materials,22, 1059–1066.CrossRef
go back to reference Gutkowski, R. M., Brown, K., Shigidi, A., & Natterer, J. (2008). Laboratory tests of composite wood–concrete beams. Journal of Structural Engineering,130(10), 1553–1561.CrossRef Gutkowski, R. M., Brown, K., Shigidi, A., & Natterer, J. (2008). Laboratory tests of composite wood–concrete beams. Journal of Structural Engineering,130(10), 1553–1561.CrossRef
go back to reference Gutkowski, R. M., & Chen, T.-M. (1996). Tests and analysis of mixed concrete–wood beams, In Proceedings of the International Wood Engineering Conference (pp. 3.436–3.442). Madison, WI: Omnipress. Gutkowski, R. M., & Chen, T.-M. (1996). Tests and analysis of mixed concrete–wood beams, In Proceedings of the International Wood Engineering Conference (pp. 3.436–3.442). Madison, WI: Omnipress.
go back to reference Gutkowski, R. M., Thompson, W., Brown, K., Etournaud, P., Shigidi, A., & Natterer, J. (1999a). Laboratory tests of composite wood–concrete beam and deck specimens. In Proceedings of 1999 RILEM Symposium on Timber Engineering (pp. 263–272). Stockholm, Sweden. Gutkowski, R. M., Thompson, W., Brown, K., Etournaud, P., Shigidi, A., & Natterer, J. (1999a). Laboratory tests of composite wood–concrete beam and deck specimens. In Proceedings of 1999 RILEM Symposium on Timber Engineering (pp. 263–272). Stockholm, Sweden.
go back to reference Gutkowski, R. M., Koike, W. E., Etournaud, P. J.-F., & Natterer, J. (1999b). Laboratory tests of composite wood–concrete beam and deck specimens. In Proceedings of STRUCTURAL FAULTS + REPAIR-99, 8th International Conference and Exhibition. London, UK. Gutkowski, R. M., Koike, W. E., Etournaud, P. J.-F., & Natterer, J. (1999b). Laboratory tests of composite wood–concrete beam and deck specimens. In Proceedings of STRUCTURAL FAULTS + REPAIR-99, 8th International Conference and Exhibition. London, UK.
go back to reference Lukaszewska, E., Johnsson, H., & Fragiacomo, M. (2008). Performance of connections for prefabricated timber–concrete composite floors. Materials and Structures,41(9), 1533–1550.CrossRef Lukaszewska, E., Johnsson, H., & Fragiacomo, M. (2008). Performance of connections for prefabricated timber–concrete composite floors. Materials and Structures,41(9), 1533–1550.CrossRef
go back to reference Natterer, J. (1997). Sustainable economy of forestry and value added utilization of forests: The only chance to save the forests of the world, State-of-the-Art Paper in Restoration of Forests—Environmental Challenges in Central and Eastern Europe. In R. Gutkowski, & Winnicki, T Proceedings of the NATO Advanced Research Workshop on Science and Technology to Save and Better Utilize Central and Eastern Europe’s Forests (pp. 97–118). New York, NY: Kluwer Academic Publishers. Natterer, J. (1997). Sustainable economy of forestry and value added utilization of forests: The only chance to save the forests of the world, State-of-the-Art Paper in Restoration of Forests—Environmental Challenges in Central and Eastern Europe. In R. Gutkowski, & Winnicki, T Proceedings of the NATO Advanced Research Workshop on Science and Technology to Save and Better Utilize Central and Eastern Europe’s Forests (pp. 97–118). New York, NY: Kluwer Academic Publishers.
go back to reference Pault, J. D., & Gutkowski, R. M. (1977). Composite action in glulam timber bridge systems, Structural Research Report No. 17B, Civil Engineering Department, Colorado State University, Ft. Collins, CO. Pault, J. D., & Gutkowski, R. M. (1977). Composite action in glulam timber bridge systems, Structural Research Report No. 17B, Civil Engineering Department, Colorado State University, Ft. Collins, CO.
go back to reference SáRibeiro, R. A., Rocha, J. S., & SáRibeiro, M. G. (2006). Vigas de madeira-concreto com conectores de resíduos de construção. In Anais/BRASIL NOCMAT 2006—Salvador—Conferência Brasileira de Materiais e Tecnologias Não-Convencionais: Materiais e Tecnologias para Construções Sustentáveis (pp. 1–7) (in Portuguese). SáRibeiro, R. A., Rocha, J. S., & SáRibeiro, M. G. (2006). Vigas de madeira-concreto com conectores de resíduos de construção. In Anais/BRASIL NOCMAT 2006SalvadorConferência Brasileira de Materiais e Tecnologias Não-Convencionais: Materiais e Tecnologias para Construções Sustentáveis (pp. 1–7) (in Portuguese).
go back to reference SáRibeiro, R. A., & SáRibeiro, M. G. (1990). Mechanical properties of Amazonian lumber for the development of design stresses. In Proceedings of the 1990 International Timber Engineering Conference (Vol. 3, pp. 819–826). Tokyo, Japan. SáRibeiro, R. A., & SáRibeiro, M. G. (1990). Mechanical properties of Amazonian lumber for the development of design stresses. In Proceedings of the 1990 International Timber Engineering Conference (Vol. 3, pp. 819–826). Tokyo, Japan.
go back to reference Wegener, W., & Zimmer, B. (1998). The ecological benefits of increased timber utilization, In Proceedings of the 5th World Conference on Timber Engineering (Vol. 1, pp. 1656–1663). Montreux, LA: Presse polytechniques et universitaires romandes. Wegener, W., & Zimmer, B. (1998). The ecological benefits of increased timber utilization, In Proceedings of the 5th World Conference on Timber Engineering (Vol. 1, pp. 1656–1663). Montreux, LA: Presse polytechniques et universitaires romandes.
go back to reference Winter, W. (1998). Economical and ecological aspects of multistory timber buildings in Europe. In Proceedings of the 5th World Conference on Timber Engineering (Vol. 1, pp. 1664–1668). Montreux, LA: Presse polytechniques et universitaires romandes. Winter, W. (1998). Economical and ecological aspects of multistory timber buildings in Europe. In Proceedings of the 5th World Conference on Timber Engineering (Vol. 1, pp. 1664–1668). Montreux, LA: Presse polytechniques et universitaires romandes.
Metadata
Title
Composite Wood–Concrete Structural Floor System with Horizontal Connectors
Authors
Ruy A. SáRibeiro
Marilene G. SáRibeiro
Publication date
01-03-2015
Publisher
Korea Concrete Institute
Published in
International Journal of Concrete Structures and Materials / Issue 1/2015
Print ISSN: 1976-0485
Electronic ISSN: 2234-1315
DOI
https://doi.org/10.1007/s40069-014-0090-3

Other articles of this Issue 1/2015

International Journal of Concrete Structures and Materials 1/2015 Go to the issue